Structure Set
Structure Set
NOTE:
SOIL BEARING CAPACITY
Foundations have been designed
According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
FE - 500/550 grade should be used.
PLY PARTITION
[Link] SLAB : 20 mm
[Link] : 40 mm
1"
[Link] WALL : 25 mm
HALL 12'-112
18'-4" X 17'-11" [Link] : 25 mm
[Link] : 15 mm
17'-9"
HALL HALL
[Link]
[Link]
[Link]
[Link]
[Link]
[Link]
DRAWING ROOM DRAWING ROOM LOBBY DRAWING ROOM LOBBY
13'-0" X 17'-7" 13'-0" X 17'-11" 6'-0" X 17'-11"
12'-0" X 17'-11"
13'-0" X 17'-11" 6'-0" X 17'-11"
12'-0" X 17'-11"
[Link] : 15 mm
[Link] RETAINING
STRUCTURES : 20/30 mm
UP UP UP UP UP UP
This drawing is the property of [Link] It may not be used for any purpose other than the owner.
[Link] does not authorize the reproduction or conveyance of any information contained herein without prior written permission.
TOILET BEDROOM
TOILET 6'-11" X 6'-5" 20'-0" X 11'-7"
6'-6" X 6'-5" NOTE:
SOIL BEARING CAPACITY
CB1 RB1 RB1 Foundations have been designed
According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
4' 1" FE - 500/550 grade should be used.
13'-62
M7.5 = [Link] ( USED AS P.C.C. )
OPEN M10= [Link]
LIVING ROOM
RB4 M15= [Link]
21'-4" X 11'-7" M20= 1:1.5:3 ( USED AS MIN. GRADE IN BUILDING )
RB4 RB4 RB4 LIVING ROOM
RB4 M25= [Link]
S1
18'-0" X 11'-7"
S2 S2 CLEAR COVER TO MAIN
S2 REINFORCEMENT:
[Link] : 50 mm
[Link] [Link] : 50 mm
[Link] FOUNDATION.
CB3 RB3 RB3 RB4 RB2 BOTTOM/SIDES : 75 mm
[Link] BEAM : 50 mm
4' 1" [Link] SLAB : 20 mm
5'-3" 11'-72 [Link] : 40 mm
[Link] WALL : 25 mm
[Link] : 25 mm
[Link] : 15 mm
S2 [Link] : 15 mm
S1
[Link] RETAINING
HB HALL
STRUCTURES : 20/30 mm
DRAWING ROOM 18'-4" X 17'-11"
RB3 13'-0" X 17'-7" RB3 RB3 RB3 RB3 Project Type: Residential
S2
Date: 23-07-2024
Sheet No.: S-01
SHEET NO. : S-01B
LVL 1'-6"
BEDROOM BEDROOM
TOILET TOILET 18'-0" X 11'-8"
14'-6" X 11'-8" NOTE:
6'-5" X 6'-5" 6'-11" X 6'-5"
SOIL BEARING CAPACITY
CB1 RB1 RB1 Foundations have been designed
According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
4' 1" 6'-7" FE - 500/550 grade should be used.
13'-62
M7.5 = [Link] ( USED AS P.C.C. )
OPEN M10= [Link]
M15= [Link]
3'-9" X 48'-9"
BALCONY
S1
SHEET NO. : S-01C
NOTE:
SOIL BEARING CAPACITY
Foundations have been designed
TERRACE
TERRACE According to given site soil condition.
25'-3" X 23'-7" STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
FE - 500/550 grade should be used.
S1
Sheet No.: S-01
SHEET NO. : S-01D
THICKNESSXDEPTH TOP BOTTOM BOTTOM TOP UP TO L/3 AFTER L/3 M7.5 = [Link] ( USED AS P.C.C. )
M10= [Link]
M15= [Link]
RB1 12" x 18" 3-16 TMT 3-20 TMT 2-16 TMT 2-16 TMT 8 # @ 5" C/C 8 # @ 6" C/C M20= 1:1.5:3 ( USED AS MIN. GRADE IN BUILDING )
M25= [Link]
CLEAR COVER TO MAIN
RB2 9" x 18" 3-16 TMT 3-16 TMT 2-12 TMT 2-12 TMT 8 # @ 5" C/C 8 # @ 6" C/C REINFORCEMENT:
[Link] : 50 mm
[Link] [Link] : 50 mm
RB3 9" x 16" 2-16 TMT 2-16 TMT 2-12 TMT 2-12 TMT 8 # @ 5" C/C 8 # @ 6" C/C [Link] FOUNDATION.
BOTTOM/SIDES : 75 mm
[Link] BEAM : 50 mm
RB4 9" x 12" 2-12 TMT 2-12 TMT 8 # @ 5" C/C 8 # @ 6" C/C [Link] SLAB : 20 mm
2-12 TMT 2-12 TMT [Link] : 40 mm
[Link] WALL : 25 mm
[Link] : 25 mm
RB5 9" x 12" 2-12 TMT 2-12 TMT 2-10 TMT 2-10 TMT 8 # @ 5" C/C 8 # @ 6" C/C [Link] : 15 mm
[Link] : 15 mm
[Link] RETAINING
CB1 12" x 18" 3-16 TMT 3-20 TMT - 2-16 TMT 8 # @ 4" C/C 8 # @ 5" C/C STRUCTURES : 20/30 mm
CB3 9" x 16" 2-16 TMT 2-16 TMT - 2-10 TMT 8 # @ 4" C/C 8 # @ 5" C/C Project Type: Residential
Date: 23-07-2024
Sheet No.: S-01
HB 9" x 5" 2-12 TMT 2-12 TMT - - 8 # @ 5" C/C 8 # @ 6" C/C SHEET NO. : S-02
SLAB DETAILS
This drawing is the property of [Link] It may not be used for any purpose other than the owner.
[Link] does not authorize the reproduction or conveyance of any information contained herein without prior written permission.
NOTE:
SOIL BEARING CAPACITY
Foundations have been designed
According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
FE - 500/550 grade should be used.
5" slab
5" slab
5" slab
2-12mmØ TOP 2-12mmØ TOP 2-12mmØ TOP 2-12mmØ TOP
2-12mmØ EX. TOP 2-12mmØ EX. TOP STRUCTURES : 20/30 mm
8 mmØ @ 5"c/c STIRRUPS 8 mmØ @ 150mm c/c STIRRUPS 8 mmØ @ 5"c/c STIRRUPS 8 mmØ @ 150mm c/c STIRRUPS
7"
7"
7"
7"
2-12mmØ BOTTOM 2-12mmØ EX. BOTTOM 2-12mmØ BOTTOM 2-12mmØ EX. BOTTOM
2-12mmØ BOTTOM 2-12mmØ BOTTOM
Project Type: Residential
SECTION A1-A1 SECTION B1-B1 SECTION A2-A2 SECTION B2-B2 Date: 23-07-2024
Sheet No.: S-01
SHEET NO. : S-03
TYPICAL PLAN AND SECTION VIEW OF BEAM PANEL
This drawing is the property of [Link] It may not be used for any purpose other than the owner.
[Link] does not authorize the reproduction or conveyance of any information contained herein without prior written permission.
Ly/4
AREA STATEMENT:
Plot Area :
Ground Floor Area :
First Floor Area :
10mm@6"c/c
NOTE:
SOIL BEARING CAPACITY
Foundations have been designed
According to given site soil condition.
A A' STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
Lx/4
FE - 500/550 grade should be used.
10mm@6"c/c
M7.5 = [Link] ( USED AS P.C.C. )
Ly
M10= [Link]
10mm@6"c/c M15= [Link]
M20= 1:1.5:3 ( USED AS MIN. GRADE IN BUILDING )
10mm@6"c/c M25= [Link]
CLEAR COVER TO MAIN
S2 S2 B S1 B'
REINFORCEMENT:
[Link] : 50 mm
[Link] [Link] : 50 mm
[Link] FOUNDATION.
BOTTOM/SIDES : 75 mm
[Link] BEAM : 50 mm
[Link] SLAB : 20 mm
[Link] : 40 mm
[Link] WALL : 25 mm
Lx
[Link] : 25 mm
[Link] : 15 mm
[Link] : 15 mm
Lx/4 Lx/4
5"
DISTRIBUTION BAR
AREA STATEMENT:
Plot Area :
Ground Floor Area :
13 First Floor Area :
4'
NOTE:
SOIL BEARING CAPACITY
24
01
UP
D
SOIL BEARING CAPACITY
Foundations have been designed
According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
Bottom Reinft FE - 500/550 grade should be used.
6' - 12' 9"/5" 6" 2 NOS 12 TMT 2 NOS 12 TMT 8MM RINGS @ 200MM c/c
12' - 14' 9"/5" 7" 2 NOS 12 TMT 2 NOS 12 TMT 8MM RINGS @ 200MM c/c
NOTE: LINTEL WILL BE AT 7' TO 8' HEIGHT ON ALL THE WALLS AS PER NEED
NOTE: IF WALL BREADTH IS 9" THAN 9" WILL BE THE BREADTH OF LINTEL BEAM AND
IF WALL BREADTH IS 5" THAN BREADTH OF LINTEL BEAM WILL BE 5".
This drawing is the property of [Link] It may not be used for any purpose other than the owner.
[Link] does not authorize the reproduction or conveyance of any information contained herein without prior written permission.
3. TMT Bars - Thermo-Mechanical Treated Bars STEEL According to given site soil condition.
STEEL REINFORCEMENT
Steel Reinforcement confirming to IS 1786-1985 code,
[Link] BAR GRADE Fe-500, Fe-550D OR HIGHER GRADE STEEL. FE - 500/550 grade should be used.
[Link] steel bars from different brands like TATA, Jindal, JSW and more M7.5 = [Link] ( USED AS P.C.C. )
M10= [Link]
M15= [Link]
#. TWO LAYERS OF BITUMENOUS PAPER TO BE PROVIDED ON M20= 1:1.5:3 ( USED AS MIN. GRADE IN BUILDING )
SUPPORTS UNDER SLABS, BEAMS AND LINTELS. M25= [Link]
CLEAR COVER TO MAIN
REINFORCEMENT:
#. STRUCTURE DRAWINGS ARE DESIGN ACCORDING TO IS CODE . [Link] : 50 mm
[Link] [Link] : 50 mm
# .LAPPING LENGTH SHOULD BE PROVIDED 48D -50D ( D-DIA OF BAR ) , [Link] FOUNDATION.
BOTTOM/SIDES : 75 mm
#. MINIMUM SPACING BETWEEN LONGITUDINAL BARS SHOULD BE 2 INCHES OR 50 MM . [Link] BEAM : 50 mm
[Link] SLAB : 20 mm
[Link] : 40 mm
NOTE-Types of Formwork ( Formwork removal time after casting of Concrete ) [Link] WALL : 25 mm
1. Vertical Formwork of Column, beam, and wall - 16 Hours to 24 hours [Link] : 25 mm
[Link] : 15 mm
[Link] removal for beams and arches [Link] : 15 mm
#.Span length up to 6m -14 Days [Link] RETAINING
#.Span length beyond 6m -21 Days STRUCTURES : 20/30 mm
[Link] removal for slab
#.Span length up to 4.5m -7 days Project Type: Residential
#.Span length beyond 4.5m -14 days Date: 23-07-2024
NOTE-Curing Time For : Sheet No.: S-01
SHEET NO. : S-07
1. PCC ( Plain Cement Concrete ) - 14 days
[Link] ( Reinforced Cement Concrete ) :- 10 days
[Link] :- 10 days
4. Plastering & Pointing : - 7 days
5. Brick & Stone Work :- 7 days
NOTE-Cement Sand Ratio For Plaster
Cement : Sand = 1:5 for the first coat of plaster with 12 mm thickness.
Cement : Sand = 1:3 for the second coat of plaster with 8 mm thickness.
NOTE-Mortar Mix Ratio
The ratio of cement to sand in brick
masonary are generally used 1:3 to 1:6
This drawing is the property of [Link] It may not be used for any purpose other than the owner.
[Link] does not authorize the reproduction or conveyance of any information contained herein without prior written permission.