LX20B Transmitter Installation Guide
LX20B Transmitter Installation Guide
GSM/GPRS/SMS/UMTS
type LX20B
Installation manual
and programming
The symbol of the crossed-out trash can reminds you that, inside the
European Union, the product must be taken to a collection point
designated at the end of its useful life. This applies to both the device
as for the accessories marked with this symbol. These should not be thrown away.
products along with unsorted municipal waste.
The manufacturer of the device promotes the policy of continuous development. Reserves
el derecho a introducir cambios y mejoras de todas las funciones del producto descritas
in this document without prior notice.
The availability of the respective functions will depend on the version of the software.
device. For more details, please contact the nearest distributor.
Under no circumstances shall the Manufacturer be responsible for any loss of data.
or profits or any special, incidental, resulting or intermediate damages
caused by any means.
MANUFACTURER
EBS Ltd.
ul. Bronisława Czecha 59
04-555 Varsovia, POLONIA
Correo electrónico: sales@[Link]
Technical assistance:support@[Link]
Website: [Link]
Index
1. Introduction.
[Link] and technical parameterss ............................................................................. 6
3. Assembly and leado ................................................................................................. 8
3.1. Connection of the LX20B transmitter with a raNura for SIM card ............................. 8
3.2. Connection of the LX20B transmitter-5D with two slots for SIM cards.................... 10
3.3. LX power supply-ZAS ........................................................................ 11
3.4. Input configurationadas................................................................................ 12
[Link] activation procedure12
5. Principle of functioningo.................................................................................... 14
[Link] programn ..................................................................................... 15
6.1. Preliminary notess .......................................................................................... 15
6.2. Computer– requirements ............................................................... 15
6.3. Program functions .................................................. 15
6.3.1. File -> New .................................................................................... 16
6.3.2. File -> Open ...................................................................................... 16
6.3.3. Archivo -> Guardar ................................................................................... 16
6.3.4. File -> Language.................................................................................... 17
6.3.5. File -> Connections ............................................................................. 17
[Link]. Crazy connectionl .................................................................................. 17
[Link]. Remote connection.............................................................................. 18
6.3.6. File -> Archiver.20
6.3.7. File -> Fin ......................................................................................... 20
6.3.8. Operaciones -> Lectura ............................................................................ 20
6.3.9. Operaciones -> Enviar .............................................................................. 20
6.3.10. Operations Event history ........................................................... 21
6.3.11. Operations -> Event monitor ............................................................ 21
6.3.12. Operations -Reset to default settings......................... 21
6.3.13. Help-> About the Program ...................................................................... 21
[Link] parameters.......................................................... 22
7.1. Access .......................................................................................................... 22
7.1.1. Transmitter
[Link]. Codeof serviceo ............................................................................. 22
[Link]. Installed coder ......................................................................... 22
[Link]. Card PIN YESM ......................................................................... 23
[Link]. Use a backup SIM card ........................................................ 23
7.1.2. Servers .............................................................................................. 23
[Link]. Servers: for devices with a SIM card slot................. 23
[Link]. Servers: for devices with two SIM card slots .............. 25
7.1.3. Switchingn ................................................................. 28
[Link]. Mobile data transmission................................................................ 28
[Link]. SMS ................................................................................................ 29
7.2. Transmissionn ................................................................................................... 30
7.3. Entries / Exits........................................................................................... 31
7.3.1. Confideticket management................................................................. 31
[Link]. Input method............................................................................... 31
[Link]. Delay ........................................................................................... 31
[Link]. Blockages ......................................................................................... 32
7.3.2. Partitions .33
[Link]. Entry that builds the partitionn ............................................................. 33
[Link]. Entries assigned to the partitionss .................................................... 33
[Link]. Delayed entries ............................................................... 33
[Link]. Time to leavea ............................................................................ 34
[Link]. Time for entry 34
7.3.3. Output configuration34
[Link]. Mode and ttime of the exit operation.............................................. 34
[Link]. Conditions ..................................................................................... 35
[Link]. Additional conditions ..................................................................... 35
7.3.4. Advanced output control ................................................................. 35
[Link]. Exit 1 / Exit 2............................................................................. 36
[Link]. Output activation time........................................................ 36
[Link]. Event: CLIP .................................................................................... 36
7.4. Monitoro ...................................................................................................... 37
7.4.1. Act. GPRS / Desact. GPRS ......................................................................... 37
LX20B–Manual Page 3 / 64
7.4.2. Activate SMS / Deactivate SMSS ............................................................................ 37
7.4.3. Omit initial state ................................................................................. 38
7.4.4. Loss of power supplyn ............................................................................ 38
7.4.5. Event: CLIP ........................................................................................... 38
7.5. Restrictions.................................................................................................. 39
7.5.1. Authorized phones for SMS39
7.5.2. Authorized numbers of GSM modems. . . . . . . . . . . . . . . . . . 40
7.5.3. Validity periods of outgoing SMS messages ....................................... 40
7.5.4. Outgoing SMS.......................................................................................... 41
7.6. SMS Notifications .................................................................................... 41
7.6.1. Telephones41
7.6.2. Events .................................................................................................. 42
7.6.3. SMS tests to the user ........................................................................ 43
7.6.4. State.................................................................................................... 44
7.6.5. SMS diversion44
7.7. Communication controln .................................................................................. 45
7.7.1. GSM ...................................................................................................... 45
7.7.2. GPRS
7.8. RS232........................................................................................................... 47
7.8.1. PUE parametersserial rto .......................................................... 47
7.8.2. Data shipment from the warehouse48
7.8.3. Advanced port optionso .................................................................. 48
[Link]. Data reception blockings ............................................................ 48
[Link]. Data sending block................................................................. 48
[Link]. Half Duplex Mode.............................................................................. 48
[Link]. Verification of the tests of the device connected to the port.................... 48
7.9. Telephone line49
7.9.1. Telephone line49
[Link]. Uuse external telephone line........................................................... 49
[Link]. Disconnect the telephone line andexternal is connected to the server ............... 49
[Link]. Monitor voltage drops on the external line.r 50
[Link]. Report when the auricle is raisedr ................................................. 50
[Link]. Report the interval between the selection of the consecutive figuress ...................... 50
[Link]. Generate dial tone with the frequencya ....................................................... 50
[Link]. Detection of picking up the handsetr 50
7.9.2. Number 1 and Number2 ................................................................................ 51
[Link]. DTM phone numberF .................................................................. 51
[Link]. Confirmation delay51
[Link]. Protocol ......................................................................................... 51
7.10. Firmwaree ....................................................................................................... 52
7.11. Monitor of events ......................................................................................... 54
7.12. History of events.............................................................................. 55
[Link] programming.................................................................................. 56
8.1. Local programming.......................................................................................... 56
8.2. Remote programminga 56
8.2.1. Pfirst programming of the deviceo .......................................................... 57
8.2.2. Reprogramming of the deviceo .................................................................. 57
[Link] Reception................................................................................................. 58
[Link] of the protocol58
[Link] with LED diodesD ................................................................................... 61
10.1. Registration on the network ........................................................................................... 61
10.2. Coverage GSM 61
10.3. TransmissionIn ................................................................................................... 62
[Link] data reception................................................................................ 62
[Link] ................................................................................................. 62
[Link] update................................................................................ 63
[Link] SIM card or damaged SIM card............................................................ 63
10.8. Error of the system ............................................................................................ 64
11. Change History............................................................................................... 64
LX20B–Manual Page 4 / 64
1. INTRODUCTION
LX20B–Manual Page 5 / 64
2. Functional and technical parameters
Transmission channels GPRS, SMS, PSTN*
* transparent, a marker is needed in the
alarm panel
Secondary server YES (GPRS, SMS)
User notifications SMS (5 phone numbers)
Communication watchdog YES
Entries 5 (NO / NC / EOL-NO / EOL-NC / DEOL-NO /
DEOL-NC
Partitions 2
Simulated PSTN line YES
Supported protocols for the input of SIA, ContactID
telephone
Disconnect function of the YES marker
the alarm control panel
Voice door function -
Outputs 2 (OC, maximum load of 100mA)
LX20B–Manual Page 6 / 64
model LX20B-A10: Cinterion ELS61-E (Penta-
LTE Bands: Bands 1, 3, 8, 20, 28 (700, 800, 900,
1800, 2100 MHz), Dual-Band UMTS/HSPA+:
Bands 8, 1 (900, 2100 MHz), Dual-Band GSM 900
and 1800 MHz);
model LX20B-A20: ELS61-US: Quad-Band LTE:
Bands 2, 4, 5, 12 (700, 850,1700/2100 (AWS)
and 1900 MHz), Tri-Band UMTS: Bands 5,4,2
(WCDMA/FDD 850, 1700/2100 (AWS) and 1900
MHz
Ethernet -
Parameters of Power supply voltage 13.8VDC (acceptable: 12-14VDC)
nutrition
-PCB (without casing) Current consumption 73mA/155mA@13.8VDC*
continue (AKU) Measurement with fully charged battery,
(medium/maximum) with Cinterion BGS2-W modem
95mA/125mA@13.8VDC*
Measurement with fully charged battery,
with EHS5-E Cinterion modem
100mA/125mA@13.8VDC*
Measurement with a fully charged battery,
with Cinterion EHS6 modem
Current consumption -
alternate (AC)
(medium/maximum)
Using the previous figure, make the following connections to the terminals of the
transmitter
OBSERVATIONS:
The connection cables to the mentioned terminals must not have a length
superior to 3 m.
The OUT1 and OUT2 outputs are of the OC type. Do not connect the outputs directly.
to the positive tensions with respect to the mass. Do not use voltages
greater than 12V. The maximum control current must not exceed 100mA.
Do not connect the power supply before connecting the antenna, as this may
cause damage to the GSM modem
ATTENTION!
THE FOLLOWING CONNECTIONS ARE ONLY USED WITH THE POWER SUPPLY LX-
IF ANOTHER TYPE OF POWER SUPPLY IS USED, THESE ENTRANCES MUST
STAY DISCONNECTED.
LX20B–Manual Page 9 / 64
Control entry. It is used to verify the presence of
BTT
battery connected to the EBS power supply.
Control input connected to the corresponding output of
PWR the EBS power supply. It is used to monitor the
presence of AC power.
THE MANUFACTURER OF THE EQUIPMENT RESERVES THE RIGHT TO MODIFY THE APPEARANCE OF
THE PRINTED CIRCUIT BOARD WITHOUT MODIFYING THE FUNCTIONALITY OF THE DEVICE.
LX20B–Manual Page 11 / 64
3.4. INPUT CONFIGURATION
LX20B–Manual Page 12 / 64
locally (through the computer and the programming cable). In these cases it can
take advantage of distance learning.
In this option, the programming is divided into two stages:
a) sending to the transmitter (via SMS) the basic parameters that allow him
connect to the communication server ([Link] system)
b) complete device configuration through the programming option to
distance (configurator of GPRS transmitters and [Link]).
The SMS format is required to contain the necessary elements, that is:
where:
█space bar
<transmitter service code>: factory set to 1111
<server address>: server address for communication designed to receive
transmitter signals, for example [Link]. In case the address is
presented in the domain format, e.g. [Link], the SMS must
attach the parameter DNS1= (address of the primary DNS server)
<server port>: server port number where the
device messages
<nombre del punto de acceso>: nombre del punto de acceso a la red GSM.
If we have access from a private network, then the SMS must include the
following parameters: UN=<user ID number> and PW=<password of
user>
Below is an example of an SMS (assuming we are using a public network and the
the server address is given in the form of IP:
1111█SERVER=[Link]█PORT=6780█APN=internet█UN=█PW=
Where:
█space bar
LX20B–Manual Página13 / 64
{"text":"5. PRINCIPLE OF OPERATION"}
When the status of the entries is in accordance with what is established in the
programming process (NO or NC), the device remains inactive. Change the
the state of any input will trigger an immediate response from the device in
form of signal transmission of such event.
Note:
Each device input (from IN1 to IN5) can be defined individually as
normally open (NO) or normally closed (NC). This means that in the state
NO, the active state will be the entry closure, and in the NC state the active state
it will be the opening.
LX20B–Manual Page 14 / 64
6. DECONFIGURATION PROGRAM
When the device is to be used for the first time, it must first be programmed by
middle of the aforementioned software. Only after carrying this out
procedure the SIM card can be inserted into the device. Otherwise the
SIM card may be blocked if the incorrect PIN code is entered. One
An alternative solution is to use the SIM card with the PIN code disabled.
The minimum requirements for the PC where the software will be installed
The configuration is presented below:
Team:
1 GHz processor or faster, 32 bits (x86) or 64 bits (x64),
1 GB of RAM (32-bit version) or 2 GB of RAM (64-bit version)
4.5 GB of hard disk space,
Software:
Operating System: Windows 7 or later,
.NET Framework 4.5 or later.
After installing and running the program, its window will appear on the screen.
main. From this level we have access to both the program functions and
the programmable parameters of the device (see chapter 0).
The main window of the program is divided into several areas.
Main menu: located at the top of the window, includes the options of
control and configuration of the program.
LX20B–Manual Page15 / 64
The main menu is also displayed in the form of icons, in the access bar.
quick
Open a new set of parameters. This option allows you to edit the parameters of
device configuration.
In the case of the file with the saved configuration, the data can be used for
program the following device. First, the catalog where it should be indicated must be specified.
saved the file and then indicated the file name. The data collection
achieved can be modified by the user. For the changes to be effective,
must be sent to the device.
LX20B–Manual Page 16 / 64
6.3.4. File -> Language
This option will allow us to select one of the available languages (defined in the
external language files.
Before starting the programming of the device, the type of connection must be defined.
we are going to use. We will have two programming methods: local and remote.
The local connection means that the configuration software (actually, the computer
in which it is installed) is directly connected to the transmitter connector
appropriate, using a special programming cable that utilizes the RS- serial port
232 (GD-PROG) or a USB or Bluetooth port (MINI-PROG-BT, SP-PROG-BT). Each
connection channel (including USB and Bluetooth) "opens" the virtual COM serial ports
used in the communication between the alarm control panel and the Configurator.
In order to program the device or perform other activities (for example, read the
device configuration, change firmware, etc.) first the must be defined the
connection parameters.
To do this, use the following window available after activating the File option.
in the Main Menu and select the Connections function or after clicking on the
icon in the quick access bar and open the RS232 tab.
We determine:
Connection name, for example, Local
We choose the appropriate serial port assigned to the connected device, for example,
COM1
In the following tab "MINI-PROG" (name coming from the programmer) also
The connection parameters must be defined.
LX20B–Manual Page 17 / 64
The steps to be taken are analogous to those in the 'RS232' tab. Specify the
name, the appropriate COM port and add the connection.
After the connection (either via USB or Bluetooth), look for the COM port.
suitable for the device and select it.
GPRS/3G Connection
Para configurar este modo, debe activar la opción Archivo del Menú Principal,
select the Connections function (or click on the icon in the access bar
quick) and open the GPRS tab.
The following window will appear on the screen.
We determine:
➢ Connection name, for example, Remote
➢ Seleccionamos el nombre de analizador, por ejemplo,primary
➢ We introduce the address of the parser, for example,[Link]
➢ We introduce the port on which the analyzer will listen for commands, e.g.
9000
LX20B–Manual Page 18 / 64
With the click of the [Add] button we confirm the settings. The connection will be saved.
(and will be visible on the table). From now on, the program will allow us to connect
to the device remotely and read and save the parameters in the memory of the
LX20B.
CSD Connection
To configure this mode, you must activate the File option in the Main Menu.
select the Connections function (or click on the icon from the access bar
quick) and open the GSM Modem tab.
With the click of the [Add] button we confirm the configuration. The connection will be saved.
(and it will be visible in the table). From now on, the program will allow us to connect.
to the device remotely and read and save the parameters in the memory of the
LX20B.
Note: Remote configuration with the CSD channel is only possible when the service of
CSD data is active both for the device's SIM card and for the card
SIM installed in the GSM modem. In addition, the LX20B transmitter must be enabled.
to receive CSD calls, see the [Link] numbers of the
GSM modems.
All configurations from the configurator, both read from the devices and the
saved on the device are automatically stored on the hard drive. If the
directories were not modified during the installation of the configurator, the files are
you can find, for example, at this location:
C:\Program Files\EBS\KonfiguratorLX\configs\LX20B_20000
The folder LX20B_20000 contains all the files related to the programming.
of the device type LX20B with factory number 20000. Its name includes the date
and the time of the operation and its type (write / read). The files have the extension
.cmi.
This function reads the data stored in the memory of the LX20B. The data is
they exchange through the selected port in the section "Select the type of
connection" (see the description of the "Settings" option below). The
Correct reading will be confirmed with the respective message. The recovered data from
device can be saved in a file (see section6.3.3 File ->
Save) and to be used for other devices.
The use of this function requires redefining the type and parameters of the connection.
For example, the following window will appear for the local connection:
where:
Port: the series port to which the transmitter is currently connected.
Access code – transmitter service code
For a detailed description of how to set up the connections, see the section
6.3.5 File -> Connections.
This function is analogous to the previous one, but it allows us to save the data in memory.
EEPROM of the transmitter LX20B. It is also possible to configure the internal clock of the
device LX20B. For this, it is necessary to select the field "Set time" and
LX20B–Manual Page 20 / 64
enter the date and time. The correct writing will be confirmed with the respective
message.
The function allows you to read the latest events saved in the device's memory.
See the chapter.lo7.12 History ofevents
This function allows controlling the device's status in real time. See the
chapterthe7.11 Monitor ofevents.
If the 'Read' operation ends with an error (for example, when it is unknown
access code), it is possible to restore the default settings. To do this, you must
select this function. A message will appear on the screen saying "Do you want to overwrite the
device parameters with the default configuration?" After
confirm it, the connection definition window will appear:
This operation is only possible in the case of a local connection. After finishing, it
they will reset to factory settings.
After selecting this function, additional information will be displayed about the
program.
LX20B–Manual Page 21 / 64
[Link] PARAMETERS
7.1. ACCESS
Transmitter
Provides limited access to the programmable parameters of the device. From this
level changes to the parameters of the following tabs cannot be made:
LX20B–Manual Page 22 / 64
Access, Transmission, Restrictions, SMS Notifications, Communication Control, RS-
232, Telephone line. The attempt to access the window with these parameters
it will end with a message about the lack of authorization.
By default, this code has the form: 2222.
Since the device uses a GSM network for its operation, it will need a
SIM card from your mobile network operator. The PIN for the SIM card intended for the
work on the specific device must be programmed before its first use. It is
necessary to automatically activate the system. In case of having a card without
The PIN code can be any value in the field, for example, 0000.
If the PIN number is entered incorrectly, the system will not start after
Insert the card and turn on the transmitter, and to use the card, it must be inserted.
the PUK number (using any GSM phone).
By default, the PIN number on the LX20B transmitter is stored in the following format:
1111.
For a device with two Nano SIM cards, the PIN must be entered for the
second card. In the case of a card without a PIN code, it can be entered
any value in this field, for example, 0000.
If the PIN number is entered incorrectly, the device will not switch to the other one.
card in case of failure of the SIM card 1 or testing of the backup card
SIM 2 and to use the card you must enter the PUK number (using any
GSM phone.
By default, the PIN number in the LX20B transmitter is saved in the following format:
1111.
After selecting this option, the testing frequency of the card must be determined.
Inactive SIM. The minimum value that can be set is 1 hour, the maximum is 24.
hours.
7.1.2. Servers
LX20B–Manual Page 23 / 64
In the case of LX20B devices with a SIM card slot, the tab
Servers are as follows:
Depending on the user's preferences, the device can operate in one of the
four modes (selection in the dropdown list):
Server off: no transmission to the server, remote communication with the user
only possible through SMS notifications
oSMS: Transmission only in SMS mode, without attempting to establish a connection.
GPRS connection.
oGPRS: as a general rule, GPRS transmission (TCP/IP protocol). In case of
problems with this connection, there is no transmission.
oGPRS & SMS: as a general rule, GPRS transmission (TCP/IP protocol) and in case
If there are problems with this connection, it will automatically switch to SMS mode.
It is the IP address of the receiver of the monitoring system ([Link]) or of the computer.
in which the "Communication Server" program is installed, for example,
[Link]. This address can also be entered in the form of the name of
server domain, for example, [Link].
Determine the server port that was designated on the server to receive the data
of the transmitter.
LX20B–Manual Page 24 / 64
[Link].[Link] server IP address
The port of the secondary server configured on the server to receive data from
transmitter.
After entering the data in the windows below, you can save the
model with parameters by pressing "+" next to the APN field. To delete the model,
click on "-".
[Link].8. APN
The parameter depends on the GSM network operator whose GPRS/3G services we are going to
use. Determine the name of the GPRS network access point. There is a possibility
to obtain the private access point. In such a case, your name is provided by the operator
concrete of the GSM network. The following table shows the names of the public APNs
current.
[Link].9. ID Usuario
In case of using the public APN it is not required. For the private APN this parameter
It must be obtained from the operator (without it, access to the GPRS network will not be achieved).
User password
In case of using the public APN, it is not required. For the private APN, this parameter
it must be obtained from the operator (without it, access to the GPRS network will not be possible).
Note: The use of the private APN increases the security of the system.
If you have a device with two SIM card slots and select the option 'Use a'
backup SIM card", the Servers tab will be as follows:
LX20B–Manual Page 25 / 64
[Link].1. Primary server
Operating mode
Depending on the user's preferences, the device can operate in one of the
four modes (selection in the dropdown list):
Server off: no transmission to the server, remote communication with the user
it is only possible through SMS notifications
oSMS: Transmission only in SMS mode, without attempting to establish a
GPRS connection.
oGPRS: as a general rule, GPRS transmission (TCP/IP protocol). In case of
problems with this connection, there is no transmission.
oGPRS & SMS: as a general rule, GPRS transmission (TCP/IP protocol) and in case
In case of problems with this connection, it will automatically switch to SMS mode.
Server IP address
It is the IP address of the recipient of the monitoring system ([Link]) or of the computer
in which the "Communication Server" program is installed, for example,
[Link]. This address can also be entered in the form of the name of
server domain, for example, [Link].
Server port
The port of the primary server configured on the server to receive data from
transmitter.
LX20B–Manual Page 26 / 64
If a GSM modem is connected to the server application (for example,
([Link]), enter your number here. Messages will be sent to this number.
SMS in case the transmitter has problems with data transmission.
If this field is empty or the digit 0 is entered, the transmitter will only work in
GPRS mode.
Note: This field will be inactive when the operating mode of the
the device is defined as GPRS
APN scheme
After entering the data in the windows below, you can save the
model with parameters by pressing '+' next to the APN field. To delete the model,
click on '-'.
APN
The parameter depends on the operator of the GSM network whose GPRS/3G services we are going to
use. Determine the name of the access point to the GPRS network. There is the possibility
to obtain the private access point. In such a case, its name is provided by the operator
concreto de la red GSM. La siguiente tabla muestra los nombres de los APN públicos
current.
ID Usuario
When using the public APN it is not required. For the private APN, this parameter
must be obtained from the operator (without it, access to the GPRS network will not be achieved).
User password
In the case of using the public APN, it is not required. For the private APN, this parameter
it must be obtained from the operator (without it, access to the GPRS network will not be achieved).
Note: The use of the private APN increases the security of the system.
All the parameters in this section refer to the secondary server and the card
SIM 2. The fields must be filled out in the same way as for the primary server.
LX20B–Manual Page 27 / 64
[Link]
After completing the data, the address and port of the primary server and the
Secondary server will be displayed in the gray field of the Servers tab.
If the GPRS mode or GPRS and SMS mode has been selected for any
server in the Servers tab, in this section you can define the parameters of
connection to the server via GPRS.
The programmed device equipped with the SIM card will attempt to connect to the server.
automatically. Here we define the time interval (in seconds) after which
it will retry the connection attempt if the previous one has failed.
We determine how many times the device will attempt to connect to the server. In case
after repeated failures, the LX20B will initiate the connection procedure to the server
secondary after the specified number of attempts. This option will be active
only when we define the parameters of the secondary server.
LX20B–Manual Page 28 / 64
[Link].2. Secondary server
If the device cannot connect to the main server, after the number of
defined attempts, it will start the connection procedure to the secondary server. Here
we define the time interval (in seconds) after which the attempt will be repeated
connection if the previous one has failed.
Here we define how many times the device will attempt to connect to the server
secondary. In case of repeated failures, the LX20B will return to the connection procedure.
with the primary server after the specified number of attempts.
If you select this checkbox, the device will disconnect from the secondary server.
after a defined period of time (in seconds). If the option 'Start with
the primary server after interrupting the connection" (chapter [Link].3) is
active, the device will attempt to connect to the primary server. If the option is not
active, the device will complete the connection procedure to the server first
secondary and, if this fails, will proceed to try to connect to the primary server.
The device sends, at the determined interval, the signal 'Test' which notifies the
monitoring station that the device is functioning. This field determines
how many seconds will such a message be sent.
If this option is selected, the device will try to connect to the server first.
primary, regardless of the parameters of the secondary server (especially,
of the number of connection attempts).
[Link]. SMS
If the SMS or GPRS and SMS operating mode has been selected for any
server in the Servers tab, in this section you can define the parameters of
connection to the server via SMS.
LX20B–Manual Page 29 / 64
[Link].2. Test event period
In case of losing the GPRS/3G connection, the information about upcoming events
it will be sent immediately by SMS, even if the device has not yet passed
SMS mode.
[Link]
To ensure the maximum security of transmitted data, the has been introduced
data encryption with the AES key. This option can be used for both
GPRS transmission like for SMS.
For the encrypted transmission, you can enter your own encryption key (256
bits: characters 0-9 and A-F) or use the default configuration.
LX20B–Manual Page 30 / 64
7.3. INPUTS / OUTPUTS
The transmitter has 5 signal inputs. In addition, the LX20B has two type outputs.
OC. The Inputs/Outputs option allows you to configure the software for the transmitter.
function according to user requirements.
[Link] Configuration
This parameter allows determining the input configuration and the steady state of
the entry. The change of this state will trigger the sending of information about the
alarm. You can choose one of the following types of configuration: NO / NC / EOL-
NO / EOL-NC / DEOL-NO / DEOL-NC. The NC entry must always be present.
short-circuited to ground - the moment of its excitation will occur when it ends the
short circuit. The NO type input remains open - at the moment of the short circuit to
The activation is carried out. The EOL and DEOL versions (parametric and doubly)
parametric) differ in one or two resistors that allow distinguishing the alarm from
sabotage. The electrical schemes for all types of configurations are described
in the [Link] configuration.
[Link]. Delay
This parameter means the minimum change time in the given input for it to
was detected by the transmitter. The factory setting for this parameter is 400
ms.
LX20B–Manual Página31 / 64
[Link]. Blockages
This option allows you to block any input from the transmitter, which prevents the
state changes in this entry are ignored and not notified to the station
monitoring. The blocking can be permanent or temporary. In the case of blocking
temporal, it is necessary to specify the number of violations after which one
it will produce the blockage and the duration of the blockage from the moment it occurred
first violation. The mechanism is illustrated in the following diagram. The blockage
permanent and temporary can be disabled by the command sent via SMS or
GPRS (see the description of the RLIMIT command in the chapterthe9.1.1.).
LX20B–Manual Page 32 / 64
7.3.2. Partitions
By using this option, you will be able to select the arm/disarm entry for the partition.
A device for assembly can be connected (for example, switch, receiver of
radio or combination lock) to the selected entry. When the entry is set
violada, se armará la partición correspondiente (después del tiempo para la salida
from the violation). If the armed entry is not breached, the partition remains
unarmed.
Here you can define the timed entries. A timed entry activates the
associated output (i.e., generates an alarm) after the 'Input time'
but only if the partition to which the entry is assigned does not disassemble before
the time for entry has ended.
LX20B–Manual Page 33 / 64
[Link]. Time for departure
Time for the partition exit. The assigned entries will be active.
(monitored) when the specified time has elapsed since the moment of
the violation of the entry of armed.
[Link] configuration
This option allows you to choose how the output works. There are two modes of
functioning:
Determine the conditions whose fulfillment activates one of the outputs. It is possible.
activate the output in the following cases:
after a failure in communication with the server (immediately after
to detect it);
after a loss of GSM network signal (immediately after
detect it);
after detecting an incoming call attempt from a number
determined
Once this option is selected, the CLIP event can be generated if
set the corresponding position in the Monitoring option (see point
7.4.5Event: CLIP). You can enter the entire phone number or
only its fragment, e.g. 1234. Then the output will be activated for all
the numbers that contain the defined sequence of digits, e.g. after detecting
the number 123456789 or 600123456. Note: The phone number must
enter without the country prefix (e.g. without 0048, +48).
in function of the change of state from inactive to active of one of the inputs.
Outputs can also be activated after the watchdog is triggered.
configurable in the tab "7. Communication control".
In the case of selecting the option 'Based on the change of state from inactive to'
active of one of the entries", we will have the option to configure the conditions
additional outputs for the activated output:
Never: the violation of the entrance will not trigger the activation of the exit
If the entry is violated, it will trigger the output in the case.
that it is not possible to send the information to the server
Always: every violation of the input will trigger the activation of the output
Available Red: the violation of the entry will trigger the activation of the output
in the event that it is possible to send the information to the server
Note: Both outputs can be controlled by SMS commands.
The user has the option to determine the alternative method of operation.
from the exits concerning the [Link] configuration.
LX20B–Manual Page 35 / 64
"[Deactivated] GSM" and "[Activated] Input x". The simultaneous use of the options of the
basic configuration of the outputs and the advanced control of the outputs may cause
an unexpected behavior of the transmitter.
In these columns, we define which signals will affect the output state.
determined. The available options are:
Doing nothing: the state of the output does not change (default action)
To activate the output permanently: the output is activated permanently.
To temporarily activate the output: the output is activated for a time.
specified by the [Link] timefrom the exit
Deactivate the output: the output is deactivated
The [Reset] button assigns the action 'Do nothing' for each of the events.
The output state will not change if the current state corresponds to the desired result.
of the action.
The parameter that determines the time for which the output must be activated for
the advanced control function of the outputs.
The incoming call detection event from the defined phone number in
the option Inputs/Outputs -> Output 1 (OUT1) / Output 2 (OUT2). The number of
LX20B–Manual Page 36 / 64
the phone is entered by selecting the option 'After detecting the attempt to carry out a'
incoming call from the number" (see the punto7.3.3.2.).
7.4. MONITORING
This option allows you to determine which of the available signals, generated by the
device, will be transmitted to the monitoring station.
In these columns, we define the signals that must be reported to the monitoring station.
with the use of GPRS transmission. We have the ability to send the information
so much about the alarms (change of the input state from rest to active)
how about the returns to the state of the entries of the asset to rest
(normalization). To transfer the given signal, it will be sufficient to mark it (when making
click on the respective square on the right.
The [Delete] button will remove all marked signals.
The [Revert] button will reverse the selections.
In these columns we define the signals that must be reported to the station of
monitoring via SMS message, when the transmitter is not connected to
server via GPRS. We have the possibility to send the information both about
LX20B–Manual Page 37 / 64
the alarms (change of the state of the entry from rest to active) like on
the returns to the state of the asset inputs to rest (normalization).
To transfer the given signal, it will be sufficient to mark it (by clicking on the
respective square to the right.
The [Delete] button will remove all marked signals.
The [Back] button will reverse the selections.
This option allows you to block the sending of information about the status of the tickets.
active at the time of connecting the power supply. The information about the inputs is
will send to the server not before the first change of the status of the asset from active to inactive
active.
For the events "Nutrition" and "Battery", do not select "Skip initial state"
will trigger the sending of information about the feed/battery during activation
of the device, regardless of the power/battery status.
One of the additional options of the device is the control of the presence of voltage.
of supply. Since losses can occur in some buildings
food from the grid during short periods, it can be omitted that they are reported,
introducing the time after which the information will be sent. The value of this
parameter means that the power cut must last this period of time
defined so that the device recognizes that it is a power outage and for
that the corresponding information be sent.
LX20B–Manual Page 38 / 64
7.5. RESTRICTIONS
En esta sección pueden definirse las restricciones para los números desde los cuales
the SMS messages are sent with the commands to the transmitter and the
CSD connections. The validity periods of the sent SMS can also be defined.
for the device and the limits of the SMS sent.
The user can restrict remote access to the device (via SMS) to
specific phone numbers. The list of numbers (up to 5) thus created means that
The device can only be controlled from these numbers.
After selecting Allow for the selected ones, access to the editing field is obtained.
Enter the following numbers in the field, then click the button
[Add] to move the number to the table below. When placing the cursor on the line
determined with the number and clicking the "Delete" button, the number will be deleted
from the table.
The 'Delete All' option will delete all the content in the table.
LX20B–Manual Page 39 / 64
Note:
a) the authorization of the incoming SMS message consists of comparing the number of
where he came with those from the table. The version of the record in the table is accepted.
take only a fragment of a number, for example 1234. Then it
they will authorize all numbers that contain the specified sequence,
example, 600123456 or 601234567.
If you use a modem connected to the [Link] to send SMS, your
The phone number must be included in the previous list.
For connections in the CSD channel, the user can limit remote access to
device from the GSM modems. The list of numbers (up to 5) thus created means that
It will be possible to contact the transmitter only from these numbers.
After selecting Allow for the selected ones, access to the editing field is obtained.
Enter the following numbers in the field, then click the button.
[Add] to move the number to the table below. When placing the cursor on the line
determined with the number and clicking the 'Delete' button, the number will be deleted
from the table.
The 'Delete all' option will erase all the content of the table.
Note:
a) the authorization of the incoming CSD connection consists of comparing the number of
where he came with those from the table. The recorded version in the table is accepted.
they take only a fragment of a number, for example 1234. Then it
they will authorize all numbers that contain the specified sequence, for
example, 600123456 or 601234567.
b) If for the CSD connections it uses a modem attached to the [Link].
Your phone number must be included in the above list.
The user can specify the time that the GSM operator has to transmit
information in the form of SMS messages in case of problems with the delivery of the
message to the recipient. Validity is defined separately for the following groups
of information:
o SMS tests to the server
o SMS events sent to the server
o SMS events sent to the user
o Responses to the commands
The selection is made from the values found in the dropdown list.
por medio de clicar en la flecha al lado del campo de selección. Hay opciones
available: 5, 10, 15, 30 minutes; 1, 2, 6, 12 hours; 1, 7 days; MAX (means lack
of the validity period).
LX20B–Manual Page 40 / 64
7.5.4. Outgoing SMS
The user will be able to limit the number of SMS that will be sent by the sender. Since
The basic transmission form must be GPRS, this limitation is important.
mainly for economic reasons.
By checking the [Activate SMS restrictions] field, we will enable access to the groups of
information that will be restricted:
o SMS tests to the server
o SMS events sent to the server
o SMS events sent to the user
o {"response":"Responses to commands"}
Max. number of SMS: Determines the maximum number of SMS messages sent
during a unit of time (see the Reset parameter of the counter). This
option protects the user from receiving too many messages, for example, in
case of failure.
Resetting the counter: This parameter determines the frequency (in minutes) of
resetting the counter of the sent SMS messages.
The user has the option to define the communications that, in the event that it occurs
the given event (e.g. change of the input state) will be sent to the numbers of
private phones. At the same time, it is important to take into account the implementation of
restrictions in this regard.
[Link]
One of the methods to limit the sending of information about events (via SMS)
It is to determine the list that contains 5 private phone numbers. The list of
created numbers means that the transmitter will send SMS messages only to
these numbers.
LX20B–Manual Page 41 / 64
By placing the cursor on the specified line with the number and clicking the button
"Delete", the number will be removed from the table.
The 'Delete All' option will erase all content from the table.
7.6.2. Events
This tab allows you to configure and edit the SMS communications sent to the numbers.
of defined telephone.
For each event in the list (Entry 1: Violation, Return, etc.) it can be defined the
text of the SMS message that will be sent in the event that the given event occurs. For
The editing fields located on the right side of the event list are useful.
LX20B–Manual Page 42 / 64
Note:
In total, the number of characters for all SMS messages is not
can exceed 2,000.
Incorrectly entered data can be deleted by marking the text.
and pressing the button [Del].
The text from the given field can be copied to the following one.
The tests of the SMS sent to the phone numbers provided by the user
They are carried out independently of the device's working mode (GPRS/SMS/GPRS)
SMS/Without server). To activate the cyclic sending function of the tests, you must
introduce in the SMS Notifications 5 phone numbers that must receive the
SMS tests from the transmitter.
LX20B–Manual Page 43 / 64
7.6.4. State
The device allows to remotely request information about the status. In this
window we edit the content of the components of the communication that will be sent to
user in response to the check status command.
The authorized phone numbers for sending the status request have been defined.
in the option of Restrictions > Authorized SMS Phones. The device's response
It will be sent to the number from which the request has arrived.
In response to the status request, the device will send an SMS message that contains
the corresponding texts that will determine the state of the inputs, outputs and
feeding.
Note:
1. The character counter remaining reports on the total number of characters that
They can be entered in the table above.
2. For the parametric entries EOL and DEOL, the alarm state occurs both
in case of violations such as sabotage.
The device is capable of transmitting the received SMS messages to the specified
phone numbers according to the configured rules. This function may be
necessary in the case of notifications by SMS about the account balance. In this
Up to 5 rules can be set for the transmission of SMS messages.
LX20B–Manual Page 44 / 64
the sender's phone number may be in an extreme case of an empty series, which
it means the adjustment to any phone number. The processing of the rules is carried out
according to the order given from the beginning to the end, that is, the result of
treatment of the current period does not influence the treatment of the following periods. Also
it means that a certain SMS message can be sent to several numbers of
phone or that the same message can be sent multiple times to the same number.
This is the case when a condition imposed on the sender's phone number is
it complies with at least two rules that have the same number of recipients.
Note: The user is responsible for the correct input of the numbers, thank you.
to which a loop will not be created in the sending of SMS messages.
[Link] CONTROL
7.7.1. GSM
LX20B–Manual Page 45 / 64
The next step is to determine what the device should do. The selection is made
by checking the respective box in case of describing the reaction:
Modem reboot
Device restart
Activation of output 1 (OUT1)
Activation of output 2 (OUT2)
In case of a communication failure with the GSM network, the device will wait for a period.
of defined time and then will carry out the planned tasks.
7.7.2. GPRS
The activation of this function (by checking the box [Enable]) will make us have
access to the parameters that determine the device's response after losing
the communication to the server.
We determine the time after which, counting from the loss of
communication, the transmitter must carry out activities aimed at
its reset. The time selection is made in the field [Restart after
of time] and is expressed in minutes.
The next step is to determine what the device should do. The selection is made
by marking the respective box in case of describing the reaction:
Modem restart
Device restart
Activation of output 1 (OUT1)
Activation of output 2 (OUT2)
LX20B–Manual Page 46 / 64
In case of a lack of GPRS communication, the device will wait for a period of time.
defined and then will carry out the planned tasks.
7.8. RS232
Parameter Value
Transmission speed 1200, 2400, 4800, 9600, 19200, 38400, 57600
(bit/s) 115200
Number of bits of data 5, 6, 7, 8
Parity Missing, Even, Odd
Stop bits 1, 2
Flow control Falta, RTS, CTS, RTS/CTS
If the serial port ("RS232" option) is not activated, on the device port there
it will send the information to the event monitor. In this case, it can be monitored the
operation of the device using the GD-PROG cable or the SP- programmer
LX20B–Manual Page 47 / 64
PROG and the application "GPRS Transmitter Configurator": Monitor option described
in the punto 7.11.
The data received from the attached device is stored in the transmitter's warehouse.
The warehouse capacity is 511 bytes. A criterion must be defined whose compliance
it will mean the transmission of data to the receiver of the monitoring system. Remain
the following options are available:
After receiving the character with the selected ASCII code
Once the determined time has elapsed
After receiving the specified number of characters.
For each of them, lists of available values have been created that are displayed.
after clicking on the corresponding arrow.
The transmitter controls the warehouse content in terms of compliance with the
determined conditions. It does so in the following order: selected character,
time, number of characters. The buffer (transmission) will be emptied when a
of the conditions.
This option allows you to block the possibility of receiving data from the connected device.
to the RS-232 port of the transmitter. It is used, for example, in the case of a malfunction or when the
LX20B is used to control another device.
This option is used to block the ability to transmit data to the device.
connected to the RS-232 port of the transmitter. Prevents accidental or unauthorized control
device authorized.
This option consists of the automatic blocking of data reception (via RTS)
in the event that the transmitter starts transmitting data to the device. Useful for some
RS-485 converters.
LX20B–Manual Page 48 / 64
[Link] LINE
The LX20B transmitter allows data to be transmitted from an adapted alarm control panel.
function with an external telephone line in case of lack of access to this line. The
The transmitter receives information from the alarm control panel through its communicator.
telephone and then transmits them through one of the available connections: GSM /
GPRS / UMTS / HSPA / SMS. For the device to function correctly, they must
define the parameters described below.
[Link] Line
In this tab, you can configure the connection with the alarm control panel.
through a telephone line.
Selecting (activating) this function means that the transmitter will collaborate with the line.
PSTN. In this way, we obtain the possibility of transmitting data from
the alarm central station through two means: via the GPRS connector and the telephone line
standard.
This option allows disconnecting the PSTN line from the terminals T1-R1 after
connect to the server. This way, the municipal line can be separated from the
alarm control panel when the events recorded by the control panel have to
report via GPRS.
LX20B–Manual Page 49 / 64
[Link]. Monitor the voltage losses of the external line
Attention: the transmitter will simulate the presence of the municipal telephone line in the
in case of
o The municipal telephone line is not connected,
o The municipal telephone line is connected, but the option for it is not activated.
pto. 2.
o The options of point 2. and point 2. are to be active and the voltage at terminals TIP-
RING has fallen below 8 V.
If parallel to the output of the communicator from the alarm central unit (connected to
the T1-R1 terminals of the transmitter) is connected to a phone, then the
lifting your handset will prevent data exchange between the central unit and the
transmitter. This situation can be controlled. Selecting this option will cause that
the corresponding report is sent to the monitoring station, provided that the
The lifting time of the handset exceeds the defined period for this parameter.
[Link]. Report the interval between the selection of the following figures
This option is used if there are no other telecommunication devices in the system.
Municipal telephone line - Transmitter LX20B - Alarm control center. In the case
to connect such a device and then for it to dial a number
phone (and, for example, make a call), then after the defined time
here (counted from when the last digit of the number is marked) the
transmitter will send the corresponding communication. The goal is to prevent the
unauthorized installation of additional devices.
LX20B–Manual Page 50 / 64
[Link] 1 and Number 2
To ensure the proper cooperation of the transmitter with the alarm control panel in
In DTMF mode, it is necessary to define several parameters. The following functions are the
same for both phone numbers that can be stored in the memory of the
device.
It is the number saved in the alarm control panel's memory. In case of...
the control center must transmit the information about the event, it must mark this
phone number. Only if this number matches the one saved in the
The transmitter will be able to transmit this information via GSM (GPRS).
Define the time after which the transmitter generates confirmation in the control center.
that the alarm center has chosen the phone number of the station
monitoring (Handshake signal). Default: 2.0 s. The standard for systems of
alarm defines this time between 0.5 and 12.5 s.
[Link]. Protocol
Here we select the data transmission protocol used by the control unit
alarms and what is understandable for the monitoring station. It can be selected
ContactID and SIA.
LX20B–Manual Page 51 / 64
Note:
1) For all protocols we can use the options:
"Authorize sending as SMS" which means that in case of lack of
GPRS communication, the data will be sent as SMS (if this mode is enabled)
available).
"Do not send data if the external line is available" meaning that in the case
that the external PSTN line is available, it will be used during transmission
from the alarm central.
2) For the ContactID format, we can activate the option "Do not verify the sum of
control. Since some alarm control panels generate an incorrect report
regarding the control sum for the data sent, the device is not capable of
confirmar la recepción de datos y, por consiguiente, la centralita intenta transmitirlos
again (until the transmission attempt counter is exhausted). To avoid this, use
this option.
7.10. FIRMWARE
The device comes with a built-in jump starter that allows for updates.
the software. During programming, all information about the
during this operation.
LX20B–Manual Page 52 / 64
d) Select the method of file transfer: local or remote
Note: The procedure for transcribing the firmware to the device is the same as in the
case of programming. Its description is available in the chapter8.
Programming of thedevice.
From now on, the device will operate under the control of the new firmware.
Attention: the above procedure must be carried out with special care,
since incorrect execution can prevent the proper functioning of the
device.
LX20B–Manual Page 53 / 64
7.11. EVENT MONITOR
This function allows you to control the device's status in real time. To use
this functionality, connect the device to a PC using the GD-PROG cable with the
switch in DEBUG position and then select the RS232 port
suitable in the field "Port". You can also use an SP-PROG programmer.
The monitor allows the following parameters to be controlled:
Power supply status AC and battery status (only if LX-ZAS is used)
Telephone line status (PSTN)
The signal level of the GSM network and the bit error rate (BER)
State of entries
The state of exits
Device type / serial number
PCB version
Device time
The changes of all the parameters are also visible in text form in the
Log field.
LX20B–Manual Page 54 / 64
7.12. HISTORY OF EVENTS
This function allows you to view the latest events saved in memory.
device. The transmitter has a non-volatile memory in which it can store.
store at least the last 5,000 events. The history can be read both through
from the GPRS connection as through RS232. In the latter case, first connect the
device to the PC via the GD-PROG cable (switch in PROG position). Also
You can connect the computer to the device using the SP-PROG programmer. A
Next, in the 'Event History' window, select the respective port.
RS232 or GPRS communication, enter the access code and click on
Reading. After the correct reading, access to such functions will be possible.
as "Filtering" and "Diagrams" through which we will be able to diagnose
quickly the device.
LX20B–Manual Page 55 / 64
8. DEVICE PROGRAMMING
[Link] PROGRAMMING
To carry out the local programming of the device, the following must be done:
a) connect the service duct between the PROG connection (on the card of
printed circuit of the device) and the computer's COM port, defined in
the option Connections-> RS-232.
b) connect power to the terminals +12V and GND. After connecting the
feeding and detecting the programming cable, the LX20B will notify you with
the LED diodes: the green one will light up and the red one will start to blink
quickly.
c) activate the software and define the device options (the description is
find in the chapter6from the manual). Enter the correct PIN code
for the SIM card.
d) copy the configuration to the device memory. The course of
save appears in the program's special window.
[Link] PROGRAMMING
In the first case, remote programming is done on the CSD channel and its
the procedure is analogous to local programming, with the difference that in the
connection options we select "GSM Modem" (see chapter6.3.5.2:
CSD Connection.
Note: Remote configuration with the CSD channel is only possible when the service of
CSD data is active for both the device's SIM card and the card.
SIM installed in the GSM modem.
LX20B–Manual Page 56 / 64
In the second case, according to the description in the chapterthe6.3.5.2: GPRS connection, it
you must define the remote connection based on the parameters of [Link]. How
[Link] receives (and sends) information exclusively from devices that
it has stored in its database, the first activity in remote programming
It will be the proper registration of the device. The procedure is described in the Manual.
of Use [Link].
Since the device does not have defined access parameters for both GPRS and
For [Link], the programming must start by entering them.
Regardless of how this introduction is carried out, the apparatus must
register first in the [Link] database.
Before proceeding with remote programming, make sure that the device is
equipped with a SIM card (with reservations indicated in chapter [Link]) and
connected to the power supply. The user must know the factory number
of the device and the phone number of the SIM card.
a) In case of using the [Link] console, in the Devices tab you must
indicate with the cursor the appropriate device.
b) Click on the 'Config' option and indicate the 'Set configuration' function.
The list of parameters will appear.
c) Enter the server address, the server port, and the APN. After
click OK, the system will send the entered parameters to the device
(SMS).
d) Wait until the device responds to the server (in the Devices tab
will be marked in green).
e) Activate the software and define the device options (the description is
find in chapter 7 of the manual).
f) Select the send function. A window will appear in which you will need to
select the remote connection (GPRS tab). Copy the configuration in the
device memory. The saving progress is shown in the window
special of the program.
g) After saving, close the configurator program.
h) The device is ready for data transmission.
Since the device has access parameters defined for both GPRS and
For [Link], programming can be done at any time.
When the device is installed in the protected building, that is, it is equipped with
the SIM card and connected to the power supply, the programming procedure will be
the following:
a) Activate the configuration software and define the device options (the
description can be found in chapter 7 of the manual.
b) Select the send function. A window will appear where you will have to
select the remote connection (GPRS tab). Copy the configuration in the
device memory. The saving progress is displayed in the window.
special of the program.
c) After saving, close the configuration program.
The device is ready to transmit data according to the new settings.
The following message format is accepted, which allows sending multiple commands to
through an SMS, each of which must be separated from the previous one by a
WHITE SPACE:
SERVICE CODE█COMMAND█COMMAND█………
where:
List of commands
DISC Disconnection of the active TCP connection.
KILL Modem reset;
RESET Device restart. Attention: all events
those not sent will be lost.
OUT=númSal,estado Activate or deactivate the outputs. numSales the number
input(0–OUT1, 1–OUT2), status is the
estado de salida (0–desactivada, 1–activada).
EXAMPLES:
OUT=1,0 deactivates the OUT2 output
OUT=1,1 activate the OUT2 output
CMD=[timeout],comando Perform the AT command and return a response. The
optional timeout parameter determines the time of
waiting for the response. This time is expressed
in seconds and is confined within the range of 1 - 30 s.
If the timeout is not provided, the value will be adopted
by default - 3 s.
DESC Return the device name, the number of
series (in the form of a hexadecimal number) and the
firmware version.
GETSTATUS Return the status of the device.
The content of the message depends on what has been
configured in the programming phase through the
GPRS configurator in the 'Notifications' tab
SMS», section «Status». The device will send a
SMS message with defined texts specifying,
among other things: current status of entries,
outputs, power supply, telephone line.
GET SIM STATUS Return the status of the SIM cards.
(solo para el modelo LX20B-5D) Formato de la respuesta: SIMX, 1:Y, 2:Y
where X is the number of the active SIM card (1 or 2)
Y is the state of each SIM card, where: OK - the
card works correctly, ERROR - there is an error
on the SIM card, UNKNOWN -has not yet been
LX20B–Manual Page58 / 64
changed to the second card, so that
unknown his status.
LX20B–Manual Page 59 / 64
RLIMIT=1 causes the lifting of the blockade of the
input IN1
DT=YY/MM/DD,hh:mm:ss Set the time on the transmitter. The time has
to provide oneself in a format compliant with the
table on the left side.
FLUSH=x Delete the event warehouse, where:
2 -system event history.
Verification of SIM card statuses (only for LX20B-5D with two slots for
SIM cards):
after the request: 1111█GETSIMSTATUS
obtendremos la respuesta:SIM1, 1:OK, 2:UNKNOWN
LX20B–Manual Page 60 / 64
[Link] WITH LED DIODES
The device indicates the current status through 4 LED diodes, mounted
directly on the printed circuit board.
Once the SIM card is inserted into the device and the power is connected, it
attempt to log in to the GSM system.
LED diodes
Test of
registration on the network
GSM
The strength of the GSM signal is indicated by the flashing of the green OK diode (1-8
flashes). The operating mode of the device is indicated by the
green diode lighting for about 2 seconds after displaying the
coverage. Yes, after pointing out the coverage, the diode does not turn on for 2
seconds, this means the SMS mode of the device. The coverage signaling
it is interrupted during the data transmission and when the data is sent
The GSM coverage is displayed again.
LED diodes
Cobertura GSM =
8
GPRS mode
GSM coverage =
6
SMS Mode
LX20B–Manual Page 61 / 64
[Link]
LED diodes
Transmission
GPRS
SMS Transmission
During the reception of data from the alarm control panel via the input
DTMF, the current state is indicated by diodes marked DTMF and STATUS.
STATE
10.5. PROGRAMMING
After detecting the programming cable, the diodes begin to signal the
programming state.
LX20B–Manual Page 62 / 64
LED diodes
Conectado
pipeline of
service
Programming in the
CSD mode
[Link] UPDATE
LED diodes
There is none
program in the
device
(1/s)
Update of
software
Decoding of 10 s
firmware received
In case of problems with the SIM card, the device signals it with the red LED.
ERROR and green OK.
LX20B–Manual Page 63 / 64
Signage
LED diode
DTMF ERROR OK STATUS
OK
green
ERROR
red
LX20B–Manual Page 64 / 64