0% found this document useful (0 votes)
112 views2 pages

Trojan L16E-AC Battery Specifications

Uploaded by

Cristian Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views2 pages

Trojan L16E-AC Battery Specifications

Uploaded by

Cristian Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DATA SHEET L16E-AC

MODEL L16E-AC with Bayonet Cap


VOLTAGE 6
MATERIAL Polypropylene
DIMENSIONS Inches (mm)
BATTERY Deep-Cycle Flooded/Wet Lead-Acid Battery
COLOR Maroon
WATERING HydroLink™ Watering System

PRODUCT + PHYSICAL SPECIFICATIONS


BCI Group Size Type Voltage Cell(s) Terminal Type G Dimensions C Inches (mm) Weight H Lbs. (kg)
Length Width Height F
903 L16E-AC 6 3 4 99 (45)
12.31 (313) 6.85 (174) 16.41 (417)

ELECTRICAL SPECIFICATIONS
Cranking Performance Capacity A Minutes Capacity B Amp-Hours (Ah) Energy (kWh) Internal Resistance (mΩ) Short Circuit Current (amps)

C.C.A.D @ 0°F (-18°C) C.A.E @ 32°F (0°C) @ 25 Amps @ 75 Amps 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr
— —
— — 766 185 303 340 370 411 2.47

CHARGING INSTRUCTIONS
Charger Voltage Settings (at 77°F/25°C)

System Voltage 6V 12V 24V 36V 48V

Bulk Charge 7.41 14.82 29.64 44.46 59.28

Float Charge 6.75 13.50 27.00 40.50 54.00

Equalize Charge 8.10 16.20 32.40 48.60 64.80


Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under or overcharging will damage the battery and shorten its life as with any battery.

CHARGING TEMPERATURE COMPENSATION STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGE


Add Subtract Percentage Charge Specific Gravity Cell 6 Volt
100 1.277 2.122 6.37
0.005 volt per cell for every 1°C below 25°C 0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F below 77°F 0.0028 volt per cell for every 1°F above 77°F 90 1.258 2.103 6.31
80 1.238 2.083 6.25
OPERATIONAL DATA 70 1.217 2.062 6.19
Operating Temperature Self Discharge 60 1.195 2.040 6.12

-4°F to 113°F (-20°C to +45°C). At 50 1.172 2.017 6.05


5 – 15% per month depending on storage
temperatures below 32°F (0°C) maintain a 40 1.148 1.993 5.98
temperature conditions.
state of charge greater than 60%. 30 1.124 1.969 5.91
20 1.098 1.943 5.83
10 1.073 1.918 5.75

TROJAN BATTERY
COMPANY WITH
QUALITY SYSTEM
Designed in compliance with applicable BCI, DIN, BS and IEC standards. CERTIFIED BY DNV
= ISO 9001:2015 =
Tested in compliance to BCI and IEC standards.
G
TERMINAL CONFIGURATIONS
4 EUTR Embedded Universal Terminal Reverse
7 6 5 47 36 2 5 1 4 3 2
NOTES: UNLESS OTHERWISE SPECIFIED ZONE NOTES: DESCRIPTION
UNLESS OTHERWISE SPECIFIED ZONE REV DATE
DESCRIPTION
Terminal Height Inches (mm)
INITIAL RELEASE; COR5864 INITIAL RELEASE;
A 1/24/17
COR5864
1.10 (28) REVISE
H TOL. BLOCK; REVISE HEIGHT AND WIDTH; COR5925 REVISE TOL.
B BLOCK;
3/15/17 REVISE
H HEIGHT AND WIDTH; COR5925
4/3/17
1. ALL DMINESIONS ARE NOMINALTorque Values in-lb (Nm) CALL OUT
1. MAX TOL. FOR LENGTH AND HEIGHT; COR5957
ALL DMINESIONS ARE NOMINAL CALL OUTC MAX TOL. FOR LENGTH AND HEIGHT; COR5957

95 – 105 (11 – 12)


2.08 Bolt 2.08
5/16" - 18
G G
1.68 1.68

F F

BATTERY DIMENSIONS (shown with EUTR)


7 6 5 4 3 2
NOTES: UNLESS OTHERWISE SPECIFIED ZONE DESCRIPTION
12.31 (313) 6.85 (174) 12.31 (313) 6.85 (174) COR5864
INITIAL RELEASE;
LENGTH WIDTH LENGTH REVISE [Link]
BLOCK; REVISE HEIGHT AND WIDTH; COR5925
HE E
11.55 11.55 CALL OUT MAX TOL. FOR LENGTH AND HEIGHT; COR5957
(293) 1. ALL DMINESIONS ARE NOMINAL
(293)

2.08

G
D
1.68 D

FC C
15.29 16.41 15.29 16.41
(388) (417) (388) (417)

SCALE 0.500 SCALE


12.31 (313) 6.85 (174)
LENGTH WIDTH B
EB
11.55
(293)
THIS DRAWING AND DATA EMBODY
PROPRIETARY INFORMATION WHICH
IS THE CONFIDENTIAL PROPERTY
OF TROJAN BATTERY COMPANY
WHICH SHALL NOT BE COPIED,
REPRODUCED DISCLOSED TO
OTHERS OR USED IN WHOLE OR
PART FOR ANY PURPOSE WITHOUT
THE EXPRESS WRITTEN
PERMISSION OF TROJAN BATTERY
CO. THIS DRAWING IS LOANED IN
CONFIDENCE WITH THE
12380 CLARK ST. SANTA FE SPRINGS, CA 90670
UNDERSTANDING THAT IT SHALL
5194 MINOLA DR. LITHONIA, GA 30038

6.60 (168) 6.60 (168)


BE RETURNED ON DEMAND

11.25 (286) D 11.25 (286) TITLE


A UNLESS OTHERWISE
SPECIFICED
L16 (E-AC & G-AC) EUTR UNLESS OTHE
SPECIFIC
TOLERANCES ARE:
MARKETING ASSEMBLY (HANDLE) TOLERANCES

SHEET 1 OF 1 X.X
[Link]
0.1"
0.05"
DWN BY
AS SCALE CHK APPVD
CSIZE=DWG SCALE
SHEET 1 OF 1 X.X
[Link]
0.1"
0.05"
[Link] 0.02" DATE DWG NO REV [Link] 0.02"

7 6 5 47 36
ANGLES = 2
5 4/3/17 721250
4 C 3
ANGLES = 2

Confidential Information of Trojan Battery Company, LLC. Confidential Information of Trojan Battery Company, LLC.
All unauthorized use, disclosure or distribution is prohibited. All unauthorized use, disclosure or distribution is prohibited.
Controlled document; user is responsible for verifying revision is current prior to use. Controlled document; user is responsible for verifying revision is current prior to use.

C
15.29 16.41
TROJAN L16E-AC PERFORMANCE PERCENT CAPACITY VS. TEMPERATURE
(388) (417)

1000 140 60
SCALE
120 50
Estimation Purposes Only
B
40
100

30
100 80
Discharge Current (amps)

20

Temperature (C)
Temperature (F)

11.25 (286) 60 6.60 (168)


A UNLESS OTHER
SPECIFICE
10 TOLERANCES

40 SHEET 1 OF 1 X.X
[Link]
0.1"
0.05"
[Link] 0.02"

7 6 5 4 3 0
ANGLES = 2

10 20 Confidential Information of Trojan Battery Company, LLC.


All unauthorized use, disclosure or distribution is prohibited.
Controlled document; user is responsible for verifying revision is current prior to use. -10

0
-20

-20 -30

1 -40 -40
10 100 1000 10000 100000
0% 20% 40% 60% 80% 100% 120%

Time (mins) Percent of Available Capacity

A. The number of minutes a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage above E. C.A. (Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 32°F (0°C)
1.75 V/cell. Capacities are based on peak performance. at a voltage above 1.2 V/cell. This is sometimes referred to as marine cranking amps @ 32°F or M.C.A. @ 32°F.
B. The amount of amp-hours (AH) a battery can deliver when discharged at a constant rate at 80°F (27°C) and maintain a voltage F. Height taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal.
above 1.75 V/cell. Capacities are based on peak performance. G. Terminal images are representative only.
C. Dimensions may vary depending on type of handle or terminal. Batteries should be mounted with 0.5 inches (12.7 mm) spacing H. Weight may vary.
minimum.
D. C.C.A. (Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintain for 30 seconds at 0°F
(-18°C) at a voltage above 1.2 V/cell.

800.423.6569 / +1.562.236.3000 / [Link] L16E-AC DS 020218

© 2018 Trojan Battery Company, LLC. All rights reserved. Trojan Battery Company is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. Trojan Battery Company reserves the right to make adjustments to this
publication at any time, without notice or obligation.