The Installation Qualification (IQ) Protocol for the Glass-Lined Reactor (GLR) outlines the necessary steps to ensure proper installation according to design specifications and regulatory standards. It includes sections on document control, objectives, scope, system description, prerequisites, verification procedures, acceptance criteria, and deviation handling. The protocol aims to confirm that all components and systems are installed correctly before proceeding to Operational and Performance Qualification.

Uploaded by

qa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
242 views4 pages

IQ For GLR

The Installation Qualification (IQ) Protocol for the Glass-Lined Reactor (GLR) outlines the necessary steps to ensure proper installation according to design specifications and regulatory standards. It includes sections on document control, objectives, scope, system description, prerequisites, verification procedures, acceptance criteria, and deviation handling. The protocol aims to confirm that all components and systems are installed correctly before proceeding to Operational and Performance Qualification.

Uploaded by

qa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

Installation Qualification (IQ) Protocol — Glass-Lined

Reactor (GLR)
1. Document Control

 Title: Installation Qualification Protocol – Glass-Lined Reactor


 Document Number: [e.g., IQ-GLR-001]
 Version: [e.g., v1.0]
 Prepared by / Reviewed by / Approved by: Include names, roles, and dates
 Revision History: Log of version updates and changes

2. Objective & Purpose

Ensure the GLR and all associated systems are installed per design specifications,
manufacturer guidelines, and user requirements. This is critical before progressing to
Operational and Performance Qualification.

3. Scope

Covers the GLR unit with its major components—agitator, utilities (steam, cooling water,
vacuum, electrical), instrumentation, and documentation. Defines boundaries including
connected systems and excluded areas.

4. System Description

Provide a concise description:

 Reactor capacity, model, serial number, location


 Configuration: vessel, jacket, agitator, instrumentation
 Utility connections

Also include referencing documentation (URS, GA drawings, P&ID, supplier specs).

5. References

 URS and DQ documentation


 Manufacturer manuals, drawings, P&IDs, instrument lists
 Regulatory and validation standards (e.g., EU GMP Annex 15)

6. Prerequisites

Before IQ execution:

 Approved validation master plan and IQ protocol


 All required documentation and materials available
 Personnel trained and briefed

7. Procedure and Checklist Components

7.1 Equipment Identification

 Verify nameplate data: serial number, model, manufacturer—against documentation

7.2 Documentation Review

 Manuals, calibration certificates, P&IDs, GA drawings verified


 Ensure documentation completeness and compliance

7.3 Installation Verification

 Confirm reactor and accessories installed per drawings


 Check alignment, mounting, and structural support quality

7.4 Utilities Verification

 Ensure proper connection of steam, cooling water, vacuum, electrical, compressed air,
and grounding
 Confirm piping, wiring, and labeling accuracy

7.5 Instrumentation & Calibration

 Check all sensors, gauges, and instruments are installed, accessible, and calibrated
(with traceable certificates)

7.6 Environmental and Safety Conditions

 Validate installation area conditions—temperature, lighting, clearances—are met


 Confirm safety provisions (e.g., emergency stops) are in place

7.7 Spare Parts & Consumables

 Verify availability of listed spare parts and consumables; ensure replenishment


strategy is defined

7.8 Personnel Training


 Confirm installation team has adequate training and qualifications to perform
installation and IQ

8. Acceptance Criteria

Each checklist entry should specify expected vs. actual, with clear pass/fail criteria—for
example:

 Serial number matches documented records


 Utilities connected and pressure within design limits
 Instruments calibrated and certificates on file

Deviation handling must be documented with root cause analysis and corrective actions.

9. Deviation & Change Control

 Document all deviations during IQ execution


 Evaluate potential impact and apply corrective actions
 Follow change control procedures for any amendments

10. Protocol Execution & Sign-offs

 Log completion dates, test results, signatures of responsible personnel


 QA to review and approve the executed IQ protocol report

11. Appendices

Include:

 IQ check sheets for each verification area (e.g., utilities, instrumentation, installation
integrity)
 Calibration certificates, instrument tags, P&ID snapshots
 Deviation log and investigation reports

Summary Table: IQ Protocol Outline

Section Description
Document Control Title, version, prepared/reviewed/approved by, revision history
Objective Ensure correct installation per specifications before OQ/PQ
Scope GLR and associated systems within qualification boundary
System Description Configuration, location, specifications, documentation references
References URS, DQ, GMP Annex 15, vendor/manual/piping and instrumentation
Section Description
drawings
Prerequisites Training, documentation, protocol approval
Equipment, documentation, installation, utilities, instruments,
Verification Steps
environment
Acceptance Criteria Defined expected results with pass/fail benchmarks
Deviations &
Logging and resolution of deviations, implementation of change control
Change
Execution & Sign-
Report execution, review, QA approval
off
Appendices Supporting documentation, check sheets, deviation logs