CSIRO Verification Services
Clayton, Victoria, Australia
+61 13 0036 3400
[Link]
Certificate of Conformity
Certificate num. Registration date Version Valid until
Number Issue date Page 1 of 5
afp - 2973 12-Jun-2015 13 3-Apr-2024 30-Apr-2025
This certification is issued within
Product designation the scope of CSIRO Verification
Services – Rules governing ActivFire
Notifier, AFP-3030 Series, fire alarm control panel Scheme and is valid only for the
product(s) as submitted for
(Refer to the Schedule/enclosures for further specified details) evaluation and verification of
conformity, subject to the following
Agent/distributor conditions.
• Reference to details, limitations
Honeywell Security and Fire and requirements, where
9 Columbia Way, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 documented as a
schedule/enclosure with this
certificate.
Registrant • The Registrant is responsible for
their attestation of conformity
Honeywell Security and Fire and ensuring that on-going
9 Columbia Way, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 production complies with the
conformance criteria defined in
Producer this certificate.
Honeywell Security and Fire • This certificate will not be valid
9 Columbia Way, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 if any changes or modifications
are made to the product which
have not been notified and
Conformance criteria and evaluation validated by CSIRO Verification
Services.
The Notifier, AFP-3030 Series, fire alarm control panel has been evaluated and verified as • This certificate is subject to
conforming with the relevant requirements of the following criteria. periodical re-validation upon
verification that all
1. Australian Standard AS 7240.2-2004, 'Fire detection and alarm systems - Part 2: Control and requirements, as determined by
indicating equipment (ISO 7240-2:2003, MOD)'. the conformity assessment
body, continue to be
2. Australian Standard AS 7240.4-2004, 'Fire detection and alarm systems - Part 4: Power supply satisfactorily met by the
Registrant.
equipment (ISO 7240-4:2003, MOD)'.
• This certificate may only be
3. Australian Standard AS 4428.3-2010, 'Fire detection, warning, control and intercom systems - reproduced in its published
form, without modification and
Control and indicating equipment - Fire brigade panel'. inclusive of all
schedules/enclosures.
Limitations/conditions of conformance • Any changes, errors or
omissions, must be submitted in
Limitations/conditions of conformance, where identified on this certificate, are derived from qualifications from writing and if necessary or
evaluation(s) for conformity and/or other related technical documentation. All details with respect to design, assembly requested, substantiated with
and installation instructions and restrictions should be checked against the producer's current technical manual/data relevant evidence.
sheets and the requirements of the Authority having Jurisdiction. • Any representations, such as
advertising or other marketing
Specified limitations/conditions, determined from the evaluation for conformity, include the related activities or articles shall
following. reflect the correct contents of
this certificate and conform
i. Compatibility of this equipment with new or existing actuating devices should be verified prior with all relevant trade practices
to installation. .and consumer protection
legislation and regulations.
ii. Variants of this equipment constructed with a solid outer door without display require a • Any terms or conditions of use
networked system with one display node installed and verified in accordance with AS 7240.2- as applicable to content and
documentation as published or
2004, Clause 13. accessed through web sites
administered by the CSIRO
Verification Services.
Issued by
Kai Loh
Executive Officer – ActivFire Scheme
© CSIRO Australia, 2024
This certificate remains the property of CSIRO and may be subject to amendment, suspension or withdrawal at any time.
The validity and authenticity of this certificate can be verified by the certification register located at [Link]
Schedule to
Certificate of Conformity
Certificate num. Registration date Version Valid until
Number Issue date Page 2 of 5
afp - 2973 12-Jun-2015 13 3-Apr-2024 30-Apr-2025
Producer's description
The Notifier, AFP-3030 Series, fire alarm control panel is an intelligent Fire Alarm Control Panel (FACP) with a flexible and
scaleable architecture which makes it suitable for virtually any application including large scale networked facilities. Fire
emergency detection and evacuation are extremely critical to life safety, and this equipment is ideally suited for these
applications.
This equipment is part of the ONYX® Series of products.
With one to ten Signalling Line Circuits (SLCs), this equipment supports up to 3,180 intelligent addressable devices per panel
and is networkable up to 200 nodes.
A host of other options are available, including single or multichannel voice; LED, LCD, or PC-based graphic annunciators;
networking; advanced detection products for challenging environments, and many additional options.
Connectivity with a range of NOTI•FIRE•NET™ integration options such as Bacnet, Modbus, OnyxWorks and Notifier
WebServer (NWS-3) permit this equipment and NOTI•FIRE•NET™ to integrate into critical component building management
systems.
Technical specification
The following details are a representative extract of the technical specification for the Notifier, AFP-3030 Series, fire alarm control panel and may be
subject to change. Complete and current details should be determined from the designated producer’s technical manual/data sheets.
Schedule of variant designations
The following is a schedule of validated variant designations of the certified/listed equipment.
Variant
Type Ident. Dimensions Other characteristic
window outer door only
CAB650 650mm(h) x 450mm(w) x 190mm(d) or solid outer door without display*
window outer door only
CAB900 900mm(h) x 450mm(w) x 190mm(d) or solid outer door without display*
window outer door only
Cabinet 18U 887mm(h) x 610mm(w) x 285mm(d) or solid outer door without display*
window outer door only
28U 1330mm(h) x 610mm(w) x 375mm(d) or solid door without display*
window outer door only
40U 1865mm(h) x 610mm(w) x 375mm(d) or solid door without display*
* Solid door without display requires a networked system with one display node installed and verified in accordance with AS 7240.2-2004, Clause 13.
Schedule of optional functions with requirements
The following schedule of AS 7240.2–2004 optional functions with requirements have been validated.
1. Controls:
a. Delays to outputs (Cl. 7.11)
b. Dependency on more than one alarm signal (Cl. 7.12)
c. Disabled condition (Cl. 10)
d. Disablement of each addressable points (Cl. 10.5)
2. Outputs:
a. Output to fire alarm devices (Cl. 7.8)
b. Control of fire alarm routing equipment (Cl. 7.9)
c. Output to fire protection equipment (Cl. 7.10)
d. Output to fault warning routing equipment (Cl. 9.9)
3. Operational
a. Impact (operational) (Cl. 16.6, Annex ZA2: not optional)
b. Vibration, sinusoidal (operational) (Cl. 16.7, Annex ZA2: not optional)
c. Alarm Acknowledgement Facility (Cl. Annex ZB)
d. Dry Heat, Steady State (Operational) (Cl. Annex ZC)
4. Marking requirements (Cl. 15, Annex ZA2: not optional)
Schedule to
Certificate of Conformity
Certificate num. Registration date Version Valid until
Number Issue date Page 3 of 5
afp - 2973 12-Jun-2015 13 3-Apr-2024 30-Apr-2025
The following schedule of AS 7240.4–2004 mandated “optional functions with requirements” have been validated.
1. Battery function check (Cl. 5.5)
2. Marking (Cl.8, Annex ZA2: not optional)
3. Impact (operational) (Cl. 16.6, Annex ZA2: not optional)
4. Vibration, sinusoidal (operational) (Cl. 16.7, Annex ZA2: not optional)
Schedule of properties/characteristics
The following schedule is an extract of physical and operational properties/characteristics of the certified/listed equipment.
Intelligent Signalling Line Circuits 1 expandable to 10
Intelligent detectors 159 per SLC
Addressable monitor/control modules 159 per SLC
Programmable software zones over 2000
ACS annunciators per CPU 32 address x 64 or 96 points
NOTE: The CPU2-3030AU can support up to 96 annunciator address points per
ACM-24AT/48A
Input voltage rating
NPS-5CHS 100-240 Vac, 50-60 Hz, 0.8-2.5 A
NPS-11CHS 100-240 Vac, 50-60 Hz, 1.5-5.0 A
Input fuse rating M205 Fuse - 250V, 8.0A
Output Current
NPS-5CHS 5.6 A @ 27.3 Vdc
NPS-11CHS 11.7 A @ 27.3 Vdc
Battery Two 12V Sealed Lead-Acid batteries.
(CAB650/CAB900 enclosures hold a maximum of two 33AH batteries)
Charger voltage 27.3 V DC
Capacity 7AH-85AH
Environmental limits 0°C to 49°C dry heat
40°C @ 93% relative humidity
IP rating IP 30
Schedule of components and/or assemblies
The following is a schedule of validated components and/or assemblies of the certified/listed equipment.
AFP-3030 ident. Description Type Protocol
CPU2-3030AU Central processing unit including field interfaces CPU
NPS-5CHS
24Vdc power supply unit PSU
NPS-11CHS
LCM-320 Loop Control Module. Provides one SLC
Loop Expander Module. Expands an ELCM-320
System supports up to five LCM-320s and five LEM-320 expanders Loop module
LEM-320
for a total
of ten SLCs
Keypad and display; includes 640-character backlit LCD display,
DISP-3030AU Display module
QWERTY programming and control keypad
NCM-F Network Control Module - Fibre
NCM-W Network Control Module - Wire
HS-NCM-W Network Control Module - Wire
HS-NCM-MF Network Control Module - Multi-mode optical fibre
HS-NCM-MFSF Network Control Module - Multi-mode/ Single-mode optical fibre -
Network control module
HS-NCM-SF Network Control Module - Single-mode optical fibre
HS-NCM-WMF Network Control Module - Wire/Multimode optical fibre
HS-NCM-WSF Network Control Module - Wire/ Single mode optical fibre
RPT-W NFN Wire-to-Wire Repeater
RPT-WF NFN Wire-to-MMOF repeater
NCA-2 Network Control Annunciator
AFP-2800 AFP-2800 FACP Panel/annunciator
IFS-2008 Agent Release Module
LCS Local Control Station
Warning signs Warning signs
(as per requirements of relevant design and installation standards)
ACM-24AT Annunciator (Control) Annunciator
ACM-48A Annunciator (Control)
ACM-8RA Annunciator (Relay Module)
Schedule to
Certificate of Conformity
Certificate num. Registration date Version Valid until
Number Issue date Page 4 of 5
afp - 2973 12-Jun-2015 13 3-Apr-2024 30-Apr-2025
AFP-3030 ident. Description Type Protocol
AEM-24AT Annunciator (expander)
AEM-48A Annunciator (expander)
LCD2-80 LCD Annunciator Kit
LDM-32 Lamp Driver Kit
LDM-E32 Lamp Driver Expander Kit Annunciator
LDM-R32 Lamp Driver Relay Kit
SCE-8A Smoke Control Annunciator (Expander)
SCS-8A Smoke Control Annunciator (Control)
SCS-8L Smoke Control Annunciator (Control)
FCM-1 Single Intelligent Control Module
FDM-1 Dual Switch Input Module
FDMR-1 Dual input/ output Module
FMM-1 Single Switch Input Module
FMM-101 Single Switch Input Mini-Module
FMM-4-20 4-20mA Intelligent Interface Module
FRM-1 Single Intelligent Relay Output Module
FZM-1 Single Conventional Zone Interface Module
ISO-X Loop (SLC) Isolator Module FlashScan
NFX-MCP-GLASS Intelligent Manual Call Point
SLC-IM Modbus Interface Module
Field module
XP-10M 10-way Switch Input Module
XP-6C 6-way Control output (NAC) Module
XP-6MA 6-way Conventional Zone Interface Module
XP-6R 6-way relay output Module
ZCM Conventional Zone Conversion Module
AAM Alarm acknowledgement module
NFX-WF-RR Addressable Strobe (NFX Series)
NFX-WSF-RR Addressable Sounder/Strobe (NFX Series)
NFX-WS-R Addressable Sounder (NFX Series)
NFX-WS-W Addressable Sounder (NFX Series)
M700X Isolator Module in 200 series
AIBS32 Intelligent Base Sounder with integrated isolator
B501 Addressable Detector Base Clip
B501AUS Addressable Detector Base
B524IEFT Short Circuit Isolator Base
Detector/sounder base
NFX-BF-IVR Addressable Strobe Base (NFX Series)
NFX-BSF-IVR Addressable Sounder/Strobe Base (NFX Series)
NFX-BS-IV Addressable Sounder Base (NFX Series)
NFXI-BS-IV Addressable Sounder Base (NFX Series)
FSP-751AUS Photo-electric smoke detector
FAPT-751AUS Intelligent Photo-Heat (Acclimate)
FAPT-851AUS Intelligent Photo-Thermal multi-sensor (Acclimate)
FSB-200 Beam Detector
FSB-200S Beam Detector with built-in test facility
FSC-851AUS IntelliQuad multi-criteria sensor
FSD-751P Innovair DSU
FSI-751AUS Intelligent Ion
FSI-851AUS Intelligent Ionization Sensor
FSL-751 View™ High Sensitivity Laser Sensor
FlashScan
FSM-500K Indoor Manual Call Point
FSP-851AUS Intelligent Photo Sensor
Actuating device (detector)
FST-751AUS Intelligent Fixed Temp. Detector
FST-751RAUS Intelligent Thermal with Rate of Rise
FST-851H High Heat Thermal
FST-851AUS Intelligent Thermal Sensor
FST-851RAUS Intelligent Thermal Sensor
FST-851R-WP Intelligent Sealed Thermal Sensor
FST-851-WP Intelligent Sealed Thermal Sensor
WCP5A-RP02SFN066-01C Outdoor Manual Call Point
FDX-851AUS Intelligent Thermal Sensor
FDX-851RAUS Intelligent Thermal Sensor
Clip
FDX-751BAUS Intelligent Thermal Sensor
FDX-751RBAUS Intelligent Thermal Sensor
Schedule to
Certificate of Conformity
Certificate num. Registration date Version Valid until
Number Issue date Page 5 of 5
afp - 2973 12-Jun-2015 13 3-Apr-2024 30-Apr-2025
AFP-3030 ident. Description Type Protocol
SDX-851AUS Intelligent Photo Sensor
IDX-751AE Intrinsically Safe Addressable Photoelectric Detector
BACNET-GW-3 Bacnet gateway
CAP-GW Common Alarm Protocol Gateway
LEDSIGN-GW LED Sign Gateway
MODBUS-GW Modbus-GW
NWS-3 NOTI-FIRE-NET WebServer Gateway -
NFN-GW-AU-EM-3 NFN gateway (Embedded)
DVC-EM Digital Voice Command
OnyxWorks OnyxWorks Workstation with and without PC gateway
VESDA-HLI-GW VESDA-Net gateway
Note: These components have been validated as connectable for the function and performance of this equipment. The schedule will be extended to
include Type 1 component compatibility upon validation and acquittal of an AS 7240.13 evaluation program.
Supplementary information
Schedule of relevant articles
The following schedule is an extract of articles significant and/or related as evidence of conformity.
Reference
Date issued
Ident. type Ident. Title / description (or date validated) Source
Compliance Appraisal to AS7240.2:2004 “Fire Detection and
15-527724.07_CIE Alarm Systems in Buildings CIE” July-2015
Honeywell – AFP 3030 panel
Opus Research Compliance Appraisal to AS7240.4:2004 “Fire Detection and
Opus Research, Petone, NZ
Report: 15-527724.07_PSE Alarm Systems in Buildings PSE”
Honeywell – AFP 3030 PSE Jun-2015
Compliance Appraisal to AS4428.3:2010 “Fire Brigade Panel”
15-527724.07_FBP
Honeywell – AFP 3030
AFP-3030
DOC-02-159:rev C 16-Sep-2016
Intelligent Fire Alarm Control Panel
Datasheet CFP-16
DOC-02-151:Rev E Conventional Extinguishing Agent 21-Jan-2015
Releasing Control Panel
Fire Alarm Control Panel
AFP-3030
DOC-01-031, Rev A 18-May-2015
Installation Manual
Australian Edition Notifier Inertia, NSW, AU
Fire Alarm Control Panel
AFP-3030
Document DOC-01-032, Rev. A 27-May-2015
Programming Manual
Australian Edition
Fire Alarm Control Panel
AFP-3030
DOC-01-033, Rev. A 27-Apr-2015
Operations Manual
Australian Edition