18.

Table of Contents

Industrial Automation and Control Cables


Industrial Automation and Control Cables Page No.
Introduction 18.2
PLC/DCS Cross Reference Guide 18.2–18.5
Industrial Communications Protocol 18.6
Industrial Data Solutions ® 18.7–18.29
Industrial Ethernet:
Introduction: Overview 18.7
DataTuff ® Twisted Pair Cables, Category 5e 18.8
DataTuff Twisted Pair Cables, Category 6 18.11
TrayOptic ® Fiber Optic Cables 18.12
Coaxial Cables 18.13
Industrial Twinax:
Belden® Blue Hose ® Selection Guide for PLC/DCS Applications 18.14
Blue Hose Cables 18.15
Twinaxial Cables 18.16
DataTray ® 600V Twinaxial Cables 18.18
Industrial Coax:
ControlNet ™ Quad Shielded Coax 18.19
ControlBus™ Quad Shielded Coax 18.20
Industrial Data:
DataBus® ISA/SP-50 FOUNDATION Fieldbus or Profibus Cables 18.21
DeviceBus® for ODVA DeviceNet™ 18.22

18
DeviceBus for Honeywell Smart Distributed System 18.25
DeviceBus for Square D/Seriplex ® 18.26
DeviceBus for Phoenix Contact InterBus®-S 18.27
EIA Industrial RS-485 PLTC/CM 18.28
Interconnect 18.29
VFD (Variable Frequency Drive) Cable 18.30
Belden Infinity® Flexible Automation Cable 18.31–18.40
Introduction: Overview & Application Guide 18.31
C-TC+ Control Cables: 600V Multi-conductor 18.32
FCC Control Cables: 600V Multi-conductor 18.34
Flex Data Cables: 300V Twisted Pairs 18.39
Flex Vision Cables: 75 Ohm Coax 18.40
UL Instrumentation Cable 18.41–18.62
300V Power-limited Tray Cables: Overview 18.41
300V PLTC/ITC: Pairs & Triads 18.42
Thermocouple Extension Cable & Wire: Overview 18.53
Thermocouple Extension Cables: Shielded Pairs 18.54
Thermocouple Extension Cables: High-Temperature, Plenum 18.55
Thermocouple Wire: Unshielded 18.55
600V Tray Cables: Overview 18.56
600V Tray Cables: Pairs & Triads 18.57
UL Control Cable 18.63–18.76
600V Type TC Cables: Overview 18.63
600V Type TC Cables: Multi-conductor 18.64
600V Type MC & Teck-Style ® Cables: Overview 18.70
600V Type MC Cables: Multi-conductor 18.71
600V Dual-rated Type MC/Teck 90 Teck-Style Cables 18.74
CSA Instrumentation Cable 18.77–18.83
300V TC/CIC: Pairs & Triads 18.77
300V CIC: Pairs & Triads and Overview 18.78
300V ACIC: Armored Pairs & Triads 18.80
600V CIC: Pairs & Triads 18.82
600V ACIC: Armored Pairs & Triads 18.83
CSA Control Cable 18.84–18.95
600V and 1000V: TC/CIC Multi-conductor 18.84
600V: CIC Multi-conductor 18.85
600V: ACIC & Teck90 18.87
1000V: Teck90 18.92
1000V: VFD Cable 18.95
Technical Information 18.96–18.98
ControlNet is a ControlNet International trademark. • DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.
Interbus is a Phoenix Contact trademarks. • Seriplex is a Square D/Schneider AEG registered trademark.

Please refer to “Terms of Use of Master Catalog” on page 22.22


INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.2

Belden IndustrialTuff Cables ®

Introduction

Tough Cables for Innovative Technology


Tough Environments
Bonded-Pairs Insulation and Jacket
Today, more than ever, manufacturing
productivity depends upon seamless data Many DataTuff Industrial Ethernet cables
®
Belden formulates many of its own
communication and automation systems. feature Belden’s patented bonded-pair insulations and jacket compounds. As a
And both depend upon high-performance technology. Bonded-pairs provide result, they provide superior performance
cabling solutions. Installable Performance® — superior under a variety of hostile environmental
electrical performance even after the conditions. See “Technical Information” at
Depend on Belden stresses of installation. Bonded-pairs the back of this section for further details.
exhibit the most robust and reliable
Belden has developed the world’s most
electrical performance in the industry. Intrinsically Safe Wiring
comprehensive line of industrial cabling
solutions for applications like yours: In accordance with NEC Article 504,
Shielding
whether you are networking your factory intrinsically safe cables are colored blue
floor or your process equipment and The evolution of technology maintains for easy identification. Belden offers
devices to their controllers…and on to the steady demand for sophisticated cable several industrial cables in intrinsically
control room, or relaying data between the shielding. Belden meets that demand with safe blue to meet your requirements
control room, the engineering department, innovative shielding and shield effective- for intrinsically safe wiring. Contact the
and remote manufacturing sites — or, ness testing methods to supply you with NEC and/or your local inspector for
all of the above. From your petrochemical, high quality, dependable cable. specific guidelines.
automotive manufacturing, pharmaceutical,
Belden’s exclusive patented Beldfoil®
power generation, pulp and paper, metals, Custom Capabilities
design, with its aluminum/polyester foil,
food and beverage, or general manufactur-
was the first shield to offer 100 percent Most of our Industrial cables are available
ing plant to your corporate headquarters
cable protection against radiated emission from stock. Many of these are available
— and everywhere in between — Belden
and ingress at audio and radio frequencies. off the shelf from distributors. If you
has your cabling solution.
have a new or unusual application or you
Most importantly you can have the peace- Armoring cannot find an Industrial cable in this
of-mind that is inherent with the use of catalog section that meets your technical
Belden’s innovative armoring technology
Belden products since all Belden cables requirements, contact Technical Support
delivers maximum physical protection in
are manufactured in ISO 9001:2000 at 1-800-BELDEN-1.
harsh environments. Additional benefits
certified facilities to the industry’s highest
include reduced cost of conduit, easier
standards of quality, utilizing the most
installation and re-routing, plus additional
advanced equipment, systems, controls
shielding.
and processes available.
Belden has the capability to protect data,
Belden cables give you the performance
electronic, instrumentation and control
you need day after dependable day.
cables with interlocking steel or aluminum
armor as well as continuous corrugated
aluminum armor. Smooth or corrugated
protective metal tapes are also available.

To Specify Part Number:


1 2 3456
Overall Armor Core Trade
Jacket Type Number
Type

Overall Jacket Type Armor Type


Code Material Code Material
1 PVC 2 Aluminum Interlock
3 CPE 3 Steel Interlock
4 TPE 8 Continuous Corrugated
5 HDPE Aluminum
6 Oil Res II
7 Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.3

PLC/DCS Cable Cross Reference Guide

PLC/DCS PLC/DCS
System Name Belden Part Number System Name Belden Part Number
Manufacturer Manufacturer

ABB/Bailey FOUNDATION Fieldbus See Protocol listings on page 8.6 GE Fanuc — DeviceNet See Protocol listings on page 8.6
Controls Industrial IT 800 X A 9880 Network Trunk Cable Sensor Device SDS See Protocol listings on page 8.6
Networks
Infinet 9880 Network Trunk Cable
9463 Blue Hose® (Standard) Honeywell Access 4000 System 9248 RG-6 PVC
Masterpiece 200 9880 Network Trunk Cable FOUNDATION Fieldbus See Protocol listings on page 8.6
9907 Thin Network Trunk Cable (Type SP50 ISA/IEC)
MICRO-DCI 3105A 1-Pair, RS-485 IPC 620 System I/O 9271 Twinax, 25 AWG, 124 Ohm
MICROLINK 9860 Twinax, 16 AWG, 124 Ohm IPC 620 System 9729 Up to 4,000 ft.
Modcell 3105A 1-Pair, RS-485 Serial Interface 9182 Up to 10,000 ft.
Profibus DP & PA See Protocol listings on page 8.6 89182 Plenum
Allen-Bradley/ ControlNet™ See Protocol listings on page 8.6 Series C RS-485 Foundation Fieldbus
Rockwell Industrial Ethernet
DeviceNet™ See Protocol listings on page 8.6
Automation 3000 UCN & LCN 3131A RG-6 Quad Shield PVC
DH, DH+, Remote I/O 9463 Blue Hose (Standard)
3094A RG-11 Quad Shield PVC
9463F Flexible Version (9463)
Honeywell Smart Distributed 3086A Mini
129463 Aluminum Armor (9463)
Microswitch System 3087A Micro
139463 Steel Armor (9463) Division
189463 Continuous Armor (9463)
YR28826 Dual Version (9463) Invensys/ FOUNDATION Fieldbus See Protocol listings on page 8.6
Foxboro (Type SP50 ISA/IEC)
YC39151 Dual Armored (9463)
I/A Series Carrier Band 8233 Small Trunk
9463DB Direct Burial (9463)
3095A Plenum
YR29565 Various Color Jackets (9463)
9290 Drop Cable
3072F 600V TC Rated (9463)
I/A Series Fieldbus 9207 Twinax
YR41104 Low Smoke, Halogen Free
89207 200°C, Plenum
YR28764 Super Thick (PLTC)
3073F 600V Tray Cable
89463 FEP 200°C, Plenum
I/A Series Node Bus 9880 Trunk Cable
DH-485 3074F 600V Tray Cable
89880 Plenum Version
3106A 1.5-Pair, RS-485 (PLTC)
Industrial Ethernet See Protocol listings on page 8.6
9842 2-Pair, RS-485
Limitorque DCC100 3105A Actuator Bus Cable, 1-Pair,
YM39500 Flexible Version (3106A) RS-485
Industrial Ethernet See Protocol listings on page 8.6 Matsushita FP Series C-NET 9207 Twinax, 20 AWG, Stranded,
Longline 8723 Interface Cable 100 Ohm
Communications 88723 Plenum Version 9860 Twinax, 16 AWG, Solid,
Cutler-Hammer/ IMPACC System YR29090 Proprietary Trunk Cable 124 Ohm
Westinghouse I/Q System 9463 Blue Hose (Standard) FP Series MEWNET-F 9207 Twinax, 20 AWG, Stranded,
100 Ohm
Emerson DeviceNet See Protocol listings on page 8.6
Process 9860 Twinax, 16 AWG, Solid,
FOUNDATION Fieldbus See Protocol listings on page 8.6
Management (Type SP50 ISA/IEC) 124 Ohm
FP Series MEWNET-H 9248 RG-6, 75 Ohm, 18 AWG
(Fisher/ HART See Protocol listings on page 8.6
Rosemont FP Series MEWNET-TR 9207 Twinax, 20 AWG, Stranded,
Industrial Ethernet See Protocol listings on page 8.6
Systems) — 100 Ohm
Modbus See Protocol listings on page 8.6
9860 Twinax, 16 AWG, Solid,
Delta V Profibus DP See Protocol listings on page 8.6 124 Ohm
Provox Plus 3091A RG-11 Quad Shield PVC FP Series MEWNET-W 9207 Twinax, 20 AWG, Stranded,
3131A RG-6 Quad Shield PVC 100 Ohm
RS-485 See Protocol listings on page 8.6 9806 4-Pair, RS-232, RS-422
GE Fanuc — DeviceNet See Protocol listings on page 8.6 FP Series MEWNET-W2 9207 Twinax, 20 AWG, Stranded,
I/O Bus Genius YR29841 PLTC Version 100 Ohm
9030, 9070 9182 Communications Bus 9860 Twinax, 16 AWG, Solid,
18 • Industrial Cables

PAC System 124 Ohm


89182 Plenum Version
FP Series TRNET 9207 Twinax, 20 AWG, Stranded,
Interbus®-S See Protocol listings on page 8.6
100 Ohm
Modbus® See Protocol listings on page 8.6
9860 Twinax, 16 AWG, Solid,
Profibus See Protocol listings on page 8.6 124 Ohm
FEP = Fluorinated Ethylene-propylene

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.4

PLC/DCS Cable Cross Reference Guide (continued)

PLC/DCS PLC/DCS
System Name Belden Part Number System Name Belden Part Number
Manufacturer Manufacturer

Mitsubishi CC-Link See Protocol listings on page 8.6 Omron Controller Link 9207 Twinax
Electric DeviceNet See Protocol listings on page 8.6 (continued) 89207 Twinax, 200°C, Plenum
Automation Melsecnet II 1505A Precision RG-59/U Coax 9815 Twinax, 100 Ohm,
(10/10H) 1505F High-Flex 1505A Direct Burial
1506A Plenum Precision RG-59/U, 3073F 600V Tray Cable, Twinax
Outdoor, Direct Burial SYSBUS-2 3073F 600V Tray Cable, Twinax
8241 Standard RG-59/U Coax SYSMAC BUS 9841 22 AWG, 1-Pair, RS-485
8241F High-Flex 8241F 3105A 22 AWG, 1-Pair, RS-485
Modbus See Protocol listings on page 8.6 SYSMAC LINK 9231 RG-59U Coax
Profibus DP See Protocol listings on page 8.6 Phoenix DeviceNet See Protocol listings on page 8.6
Serial 8777 Control and Instrumentation Contact Industrial Ethernet See Protocol listings on page 8.6
Communications Interconnect Cable
Interbus®-S See Protocol listings on page 8.6
Modicon/ Industrial Ethernet See Protocol listings on page 8.6
Profibus DP FMS & PA See Protocol listings on page 8.6
Schneider AEG Modbus 8777 Modem Drop Cable, Reliance/A-B Auto Max M9B021 2-Fiber Breakout
22 AWG, 3-Pair Distributed Power I100255 2-Fiber Loose Tube PVC
128777 Aluminum Armor (8777)
I100266 2-Fiber Loose Tube CPE
138777 Steel Armor (8777)
R-Net 9259 RG-59 PVC
88777 FEP 200°C, Plenum
89259 RG-59, 200°C, Plenum
Modbus II 3092A RG-6 Quad Shield PVC
Rotork Pakscan II E RS-485 3105A 22 AWG, 1-Pair, RS-485
3132A RG-6 Quad Shield, 150°C,
Plenum Siemens/ FMC (Field Mountable 3105A 1-Pair, RS-485
Moore Controller) 3106A 1.5-Pair, RS-485
3092F RG-6 Quad Shield PVC,
Flexible Version 3107A 2-Pair, RS-485
123092A Aluminum Armor (3092A) 3108A 3-Pair, RS-485
133092A Steel Armor (3092A) 3109A 4-Pair, RS-485
Modbus Plus YM29560 24 AWG, 1-Pair, RS-485 FOUNDATION See Protocol listings on page 8.6
YC39000 Aluminum Armor (YM29560) Fieldbus
(Type SP50 ISA/IEC)
YC39222 Steel Armor (YM29560)
YQ29258 24 AWG, 1-Pair, 150°C, Hiway 9860 Network Trunk Cable
Plenum Industrial Ethernet
See Protocol listings on page 8.6
Remote I/O 3092A RG-6 Quad Shield PVC MODULNET 3094A RG-11 Quad Shield PVC
3092F RG-6 Quad Shield PVC, 3131A RG-6 Quad Shield PVC
Flexible Version Profibus DP & FMS See Protocol listings on page 8.6
123092A Aluminum Armor (3092A) (Purple)
133092A Steel Armor (3092A) Profibus PA (Blue) See Protocol listings on page 8.6
123092F Aluminum Armor, RG-6 SINEC Series H1 9907 Thin Network Trunk Cable
Quad Shield PVC 9880 Network Trunk Cable
3132A RG-6 Quad Shield, 150°C, SINEC Series H2B 3131A RG-6 Quad Shield
Plenum 3094A RG-11 Quad Shield
3094A RG-11 Quad Shield PVC SINEC Series L1 3107A 2-Pair, RS-485
123094A Aluminum Armor (3094A) SINEC Series L2 3079A 300V Twinax
133094A Steel Armor (3094A) Thicknet Ethernet 9880 Network Trunk Cable
3095A RG-11 Quad Shield, 150°C, Trunk
Plenum 129880 Aluminum Interlocked
Omron ComboBus/D See DeviceNet Protocol listings Armor Trunk
(DeviceNet™) on page 8.6 139880 Steel Interlocked Armor
ComboBus/S 9409 18 AWG, 1-Pair, 300V Trunk
PLTC Control Thinnet Ethernet 9907 Thin Network Trunk Cable
9318 18 AWG, 1-Pair, 300V Trunk
PLTC Control, Shielded FEP = Fluorinated Ethylene-propylene
3073 600V Tray Cable, Twinax
89740 18 AWG, 1-Pair, 300V,
Control

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.5

PLC/DCS Cable Cross Reference Guide (continued)

PLC/DCS PLC/DCS
System Name Belden Part Number System Name Belden Part Number
Manufacturer Manufacturer

Smar FOUNDATION Fieldbus See Protocol listings on page 8.6 Yokogawa — DeviceNet™ See Protocol listings on page 8.6
(Type SP50 ISA/IEC) CENTUM FOUNDATION See Protocol listings on page 8.6
Industrial Ethernet See Protocol listings on page 8.6 Fieldbus
Profibus DP FMS & PA See Protocol listings on page 8.6 (Type SP50 ISA/IEC)
RS-485 See Protocol listings on page 8.6 HART See Protocol listings on page 8.6
Square D/ FIP/Fieldbus 3079A 22 AWG, 1-Pair, Shielded Industrial Ethernet See Protocol listings on page 8.6
Schneider AEG 123079A Aluminum Armor (3079A) Profibus See Protocol listings on page 8.6
Industrial Ethernet See Protocol listings on page 8.6 RS-485 See Protocol listings on page 8.6
Model 50, RS-422 8760 18 AWG, 1-Pair, Shielded Yokogawa — DeviceNet See Protocol listings on page 8.6
Cable FA-M3 Industrial Ethernet See Protocol listings on page 8.6
128760 Aluminum Armor (8760)
Passport I/O – I/O Net 3105A 22 AWG, 1-Pair, RS-485 Modbus See Protocol listings on page 8.6
123105A Aluminum Armor (3105A) Profibus See Protocol listings on page 8.6
3106A 22 AWG, 1.5-Pair, RS-485 RS-485 See Protocol listings on page 8.6
123106A Aluminum Armor (3106A) Yokogawa — DeviceNet See Protocol listings on page 8.6
Power Logic 9841 24 AWG, 1-Pair, RS-485 STARDOM FOUNDATION See Protocol listings on page 8.6
9842 24 AWG, 2-Pair, RS-485 Fieldbus
(Type SP50 ISA/IEC)
Square D/ Seriplex® 3124A CBL-1822-P20
HART See Protocol listings on page 8.6
Schneider AEG 3125A CBL-1622-P16
Industrial Ethernet See Protocol listings on page 8.6
3126A CBL-162212-P16
Profibus See Protocol listings on page 8.6
123124A Aluminum Armor (3124A)
RS-485 See Protocol listings on page 8.6
123125A Aluminum Armor (3125A)
Westinghouse WDPF 9292 RG-11 PVC
123126A Aluminum Armor (3126A)
FEP = Fluorinated Ethylene-propylene
9463 Blue Hose® (Standard)
9463F Flexible Version (9463) ControlNet is a ControlNet International, Ltd. trademark.
129463 Aluminum Armor (9463) DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.
139463 Steel Armor (9463) EtherNet/IP is a ControlNet International, Ltd. trademark,
under license by Open DeviceNet Vendor Association, Inc.
189463 Continuous Armor (9463)
HART is a HART Communication Foundation trademark.
YR28826 Dual Version (9463)
InterBus is a Phoenix Contact trademark.
9463DB Direct Burial (9463) Modbus is a Modicon, Inc. trademark.
YR29565 Various Color Jackets 9463) PROFIBUS is a PROFIBUS International trademark.
SY/Net Network 3072F 600V TC Rated (9463) PROFINET is a PROFIBUS International trademark.
Trunk Cable YR41194 Low-Smoke, Halogen-Free SDS is a Honeywell International, Inc. trademark.
YR28764 Super Thick (PLTC) Seriplex is a Square D/Schneider AEG trademark.
89463 FEP 200°C, Plenum
SY/Net TNIM Cable 9272 20 AWG, 1-Pair, Shielded
89272 FEP 200°C, Plenum

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.6

Industrial Communications Protocol


Cross Reference

System Name Belden Part Number System Name Belden Part Number

Can Open/HART/ 3105A 1-Pair, RS-485 (PLTC) Industrial Ethernet 11700A Cat 5e, 4-Pair, Bonded, Upjacketed
RS-485 (continued)
3106A 1.5-Pair, RS-485 (PLTC) 11700A2 Cat 5e, 4-Pair, Bonded, Upjacketed,
3107A 2-Pair, RS-485 (PLTC) Oil Res II
CC-Link YR47198 20 AWG/3c, Foil + Braid Shield 121700A Cat 5e, 4-Pair, Bonded, Armored
YR47205 20 AWG/3c Shielded + 18 AWG/2c Power 7919A Cat 5e, 4-Pair, Shielded
ControlNet™ 3092A RG-6 PVC Quad Shield 7921A Cat 5e, 4-Pair, Bonded, Shielded
(Foil + Braid)
3092F RG-6 PVC Quad Shield, Flex Version,
Aluminum Braid 7927A Cat 6, 4-Pair, Bonded
YR28890 RG-6 PVC Quad Shield, Flex Version, 7931A Cat 6, 4-Pair, Bonded, Gas Res,
Copper Braid High + Low Temperature
3093A RG-6 FEP Quad Shield, Plenum 11872A Cat 6, 4-Pair, Bonded, Upjacketed
123092A Aluminum Armor (3092A) 121872A Cat 6, 4-Pair, Bonded, Armored
133092A Steel Armor (3092A) Interbus®-S 3119A 18 AWG/3c, 24 AWG/3-Pair, Composite
183092A Continuous Armor (3092A) 3120A 24 AWG/3-Pair
DataHighway (DH) 9463 20 AWG Twinax, Blue Hose IronWorks® 8471 16 AWG, 1-Pair, UL AWM 2598
& DataHighway Plus 3072F 600V, TC Blue Hose 8917 16 AWG, 1-Cond, UL AWM 1015
(DH+) Remote I/O 9463DB Direct Burial Blue Hose 85102 16 AWG, 2-Cond, VW1, Plenum
9463F High-Flex, Blue Hose Modbus 8777 22 AWG, 3-Pair, Modem Drop Cable
89463 High-Temp, Plenum Blue Hose 128777 Aluminum Armor (8777)
129463 Aluminum Armor (9463) 138777 Steel Armor (8777)
139463 Steel Armor (9463) 88777 FEP 200°C, Plenum (8777)
189463 Continuous Armor (9463) Profibus DP 3079A 22 AWG 300V Twinax
YR28826 Dual Blue Hose & FMS (Purple) 3079E 22 AWG 300V Twinax, Flex Version
YC39151 Dual Armored Blue Hose Profibus PA (Blue) 3076F 18 AWG, 2-Conductors, Type A
YR28764 Thick Wall PLTC Blue Hose RS-485/HART/ 9841 1-Pair
YR29565 Colored Blue Hose Can Open 82841 1-Pair, Plenum
YR41104 Low-Smoke, Zero-Halogen Blue Hose 89841 1-Pair, Plenum, High-Temperature
DeviceNet™ 3082A PVC (Thick) 9842 2-Pair
3082F High-Flex (Thick) 82842 2-Pair, Plenum
3082K CL2 (Flat) 9843 3-Pair
3082KP Auxiliary Power (Flat) 9844 4-Pair
3083A CPE (Thick) 7200A 1-Pair, RS-485, Hi-Flex
3084A PVC (Thin) 7201A 2-Pair, RS-485, Hi-Flex
3084F High-Flex (Thin) 7202A 3-Pair, RS-485, Hi-Flex
3085A CPE (Thin)
7203A 4-Pair, RS-485, Hi-Flex
7895A CL2 PVC (Cable III Mid)
7206A 1-Pair, RS-485, Hi-Flex
7896A CL1 PVC (Type V Trunk Cable)
3105A 1-Pair, RS-485 (PLTC)
7897A CL1 PVC (Thick)
3106A 1.5-Pair, RS-485 (PLTC)
7900A CL1 Unshielded (Drop Cable IV)
3107A 2-Pair, RS-485 (PLTC)
FOUNDATION Fieldbus 3076F Type A, H1 1900m (31.25K)
3108A 3 Pair, RS-485 (PLTC)
(Type SP50 ISA/IEC) 3077F Type B, H1 1200m (31.25K)
3109A 4 Pair, RS-485 (PLTC)
HSE Copper & Fiber
(see Cables for Industrial Ethernet, pg. 18.6) Seriplex® 3124A 1-Pair 18 AWG, 1-Pair 22 AWG
Hart/RS-485/ 3105A 1-Pair, RS-485 (PLTC) 3125A 1-Pair 16 AWG, 1-Pair 22 AWG
Can Open 3106A 1.5-Pair, RS-485 (PLTC) 3126A 1-Pair 16 AWG, 1-Pair 22 AWG,
1-Pair 12 AWG
3107A 2-Pair, RS-485 (PLTC)
123124A Aluminum Armor (3124A)
Industrial Ethernet 7932A Cat 5e, 2-Pair, Bonded
123125A Aluminum Armor (3125A)
7933A Cat 5e, 2-Pair, Bonded, Shielded
123126A Aluminum Armor (3126A)
7918A Cat 5e, 4-Pair
7924A Cat 5e, 4-Pair, Bonded, Flexible Smart Distributed 3086A 1-Pair 16 AWG, 1-Pair 20 AWG
System (SDS) 3087A 2-Pairs 22 AWG
7930A Cat 5e, 4-Pair, Flexible
FEP = Fluorinated Ethylene-propylene
7922A Cat 5e, 4-Pair, Bonded, PLTC
7934A Cat 5e, 4-Pair, Bonded, Burial

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.7

Industrial Data Solutions — Industrial Ethernet ®

®
DataTuff Twisted Pair and TrayOptic® Fiber Optic Cables
Overview

The reliability of your industrial Ethernet quality and reliability into each cable This performance advantage is achieved by
network depends on the cable infrastructure. it manufactures. Decades of leadership bonding the individual insulated conductors
Data transmission errors can lead to and experience in supplying reliable along their longitudinal axes, resulting in
interruptions in critical control functions high-end cable solutions, such as uniform conductor-to-conductor spacing and
resulting in lost production time and even Blue Hose®, to industrial networks and the elimination of gaps between conductors
safety issues. Belden’s family of industrial control systems are combined to give that can occur during installation. This is
Ethernet cables is designed to withstand the you industrial Ethernet cables that a critical construction feature because
rigors of industrial environments. Whether perform to maximum network capability. non-uniform conductor spacing and gaps
it’s exposure to oil and sunlight, temperature change the physical characteristics of the
Our dedication to quality manufacturing
variation, abrasion and crushing, or the cable such that the electrical performance of
practices and processes assures consistent
presence of electromagnetic interference the cable suffers. Only Bonded-Pair cables
products of uncompromising quality.
(EMI) or radio frequency interference (RFI), deliver the electrical integrity you demand.
turn to Belden for the solution.
Belden offers an extensive line of high Installable Performance®
TrayOptic Cables
performance cables in both copper with Patented Bonded-Pair
constructions with DataTuff cables as well Technology Belden® TrayOptic cables are a line of
as fiber optic designs with TrayOptic cables. indoor/outdoor fiber optic cables designed
Belden’s Bonded-Pair versions of DataTuff
to meet the demanding requirements
cables are unique in the industry to give
of industrial applications. When the
Performance Assurance from you an Installable Performance advantage.
installation demands the combination of
Blue Hose® to Industrial Ethernet This patented design yields superior
sophisticated fiber optic technology and
electrical performance even after the
rugged durability, turn to Belden.
To assist you in achieving optimum effects and stresses of pulling, twisting
network performance, Belden has built and bending during typical installations.

DataTuff® Industrial Ethernet Cable Selection Guide

Shielding Conductor Installation Environmental Issues Industrial Grade Jacket


No.
Part
of Installation UV Under- Gasoline
No. Pull Oil CMX/ ground Hi/Lo
Pairs Unshielded Shielded Solid Stranded Stress Sunlight Heavy Upjacket Armored
** † Tension Resistance Resistance Outdoor Resistance Temp
* Resistance (burial)

Category 5e Cable
u 7932A 2 ● ● ● 20 ● ● ●

u 7933A 2 ● ● ● 20 ● ● ●

7923A 4 ● ● ● 40 ● ● ● ●

7918A 4 ● ● 35 ● ● ● ●
7924A 4 ● ● ● 40 ● ● ● ●
u 7930A 4 ● ● 25 ● ● ● ●
u 7922A 4 ● ● ● 40 ● ● ● ●
PLTC
u 7934A 4 ● ● ● 40 ● ● ●

7928A 4 ● ● ● 40 ● ● ● ● ●

11700A 4 ● ● ● 40 ● ● ● ●

u 11700A2 4 ● ● ● 40 ● ● ●
Oil Res I&II
121700A 4 ● ● ● 40 ● ● ●
u 121700R 4 ● ● ● 40 ● ● ●
7929A 4 ● ● ● 35 ● ● ● ●
7919A 4 ● ● 25 ● ● ● ●
7921A 4 ● ● ● 75 ● ● ● ●
18 • Industrial Cables

Category 6 Cable
7927A 4 ● ● ● 45 ● ● ●
7931A 4 ● ● ● 40 ● ● ● ● ●
11872A 4 ● ● ● 45 ●
121872A 4 ● ● ● 45 ● ● ●
*Shielded products are recommended for high-noise environments. **Stranded products are recommended where more flexibility is needed.

Products with Bonded-Pair technology provide Installable Performance® advantages — refer to Belden’s Bonded-Pair Cable Bulletin #BP02
EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.8

Industrial Data Solutions — Industrial Ethernet ®

®
Category 5e DataTuff Twisted Pair Cables, 2-Pair and 4-Pair
Heavy-Duty Sunlight and Oil-Resistant Jackets

Standard Nominal Max. Min. Min. Min.


UL NEC/ No. Standard Lengths Input Min.
Description
Part
C(UL) CEC of
Unit Wt. OD Freq. Atten. PSUM PSUM PSUM Imped. RL
No. (MHz) (dB/ NEXT ACR ELFEXT
Type Pairs Ft. m Lbs. kg Inch mm (dB/ (dB/ (Ω) (dB)
100m) (dB)
100m) 100m)

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC Conductors • Rip Cord • See Color Codes below
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red or Teal)
7932A NEC: 2 1000 304.8 19.0 8.61 .207 5.26 1 2.0 65.3 63.3 60.8 100±12 20.0
Compliant u CMR 2000 ▲ 609.6 38.0 17.24 4
8
4.0
5.7
56.3
51.8
52.3
46.1
48.7
42.7
100±12
100±12
23.6
25.4
CEC: 10 6.4 50.3 43.9 40.8 100±12 26.0
CMR FT4 16 8.1 47.3 39.1 36.7 100±12 26.0
25 10.3 44.3 34.1 32.8 100±15 25.5
31.25 11.6 42.9 31.3 30.9 100±15 25.0
Rip Cord 62.5 16.8 38.4 21.6 24.8 100±15 23.5
100 21.7 35.3 17.1 20.8 100±15 22.5
▲ 155 27.7 32.5 4.7 16.9 100±18 19.0
2000 ft. put-up available in Black only. • M-12 or RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals 200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 250 36.4 29.3 — 12.8 100±20 18.0
Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 350 44.3 27.2 — 9.9 100±22 17.0
7923A NEC: 4 1000 304.8 28.0 12.7 .230 5.84 1 2.0 65.3 63.3 60.8 100±12 20.0
Compliant CMR, 2000 ▲ 609.6 54.0 24.5 4 4.0 56.3 52.3 48.7 100±12 23.6
8 5.7 51.8 46.1 42.7 100±12 25.4
CMX- 10 6.4 50.3 43.9 40.8 100±12 26.0
Outdoor 16 8.1 47.3 39.1 36.7 100±12 26.0
CEC: 25 10.3 44.3 34.1 32.8 100±15 25.5
31.25 11.6 42.9 31.3 30.9 100±15 25.0
CMR FT4 62.5 16.8 38.4 21.6 24.8 100±15 23.5
Rip Cord 100 21.7 35.3 17.1 20.8 100±15 22.5
▲ 155 27.7 32.5 4.7 16.9 100±18 19.0
2000 ft. put-up available in Black only. • RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals 200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 250 36.4 29.3 — 12.8 100±20 18.0
Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 • P-07-KA060003-MSHA* 350 44.3 27.2 — 9.9 100±22 17.0
Polyolefin Insulation • Waterblocked Sunlight- and Oil-resistant Black Polyethylene Jacket
7934A — 4 1000 304.8 25.0 11.34 .230 5.84 1 2.0 62.3 60.0 60.8 100±15 20.0
Compliant u 4
8
4.1
5.8
53.3
48.8
49.0
43.0
48.7
42.7
100±15
100±15
23.6
25.4
Halogen-Free 10 6.5 47.3 41.0 40.8 100±15 26.0
Burial 16 8.2 44.3 36.0 36.7 100±15 26.0
20 9.3 42.8 33.5 34.7 100±15 26.0
25 10.4 41.3 30.9 32.8 100±15 25.5
31.25 11.7 39.9 28.0 30.9 100±15 25.0
62.5 17.0 35.4 19.0 24.8 100±15 23.5
100 22.0 32.3 11.0 20.8 100±15 22.5
RJ-45 Compatible • Jacket sequentially marked at 3 ft. intervals 155 28.1 29.5 1.4 16.9 100±25 15.8
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 200 32.0 27.8 1.0 14.7 100±25 15.0
Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 • Waterblocked per Telcordia, IEC and ICEA
Plenum • FEP Insulation • Sunlight-, Oil- and Gas-resistant Black FEP Jacket
Compliant 7928A NEC: 4 1000 304.8 24.0 10.9 .187 4.75 1 2.0 65.3 63.3 60.8 100±12 20.0
High & Low Temp Limited 4 4.0 56.3 52.3 48.7 100±12 23.6
8 5.7 51.8 46.1 42.7 100±12 25.4
Oil Res I & II Combustible 10 6.4 50.3 43.9 40.8 100±12 26.0
Gas Res FHC 25/50 16 8.1 47.3 39.1 36.7 100±12 26.0
CMP 25 10.3 44.3 34.1 32.8 100±15 25.5
31.25 11.6 42.9 31.3 30.9 100±15 25.0
CEC: 62.5 16.8 38.4 21.6 24.8 100±15 23.5
CMP FT6 100 21.7 35.3 17.1 20.8 100±15 22.5
155 27.7 32.5 4.7 16.9 100±18 19.0
RJ-45 Compatible 200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -70°C Cold Bend per UL1581 • Installation Temperature: -55°C to +150°C • Operating Temperature: -70°C to +150°C** 250 36.4 29.3 — 12.8 100±20 18.0
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 350 44.3 27.2 — 9.9 100±22 17.0
Polyolefin Insulation • PVC Inner Jacket • .035″ Industrial Grade PVC Outer Jacket (Black, Gray, Red, Teal or Blue)
11700A NEC: 4 1000 304.8 39.0 17.7 .285 7.24 1 2.0 65.3 63.3 60.8 100±12 20.0
Compliant CMR, 3000 † 914.4 117.0 53.2 4 4.0 56.3 52.3 48.7 100±12 23.6
8 5.7 51.8 46.1 42.7 100±12 25.4
Upjacketed CMX- Nominal 10 6.4 50.3 43.9 40.8 100±12 26.0
Outdoor Core OD: 16 8.1 47.3 39.1 36.7 100±12 26.0
CEC: .200 5.08 25 10.3 44.3 34.1 32.8 100±15 25.5
31.25 11.6 42.9 31.3 30.9 100±15 25.0
CMR FT4 62.5 16.8 38.4 21.6 24.8 100±15 23.5
100 21.7 35.3 17.1 20.8 100±15 22.5
Rip Cords 155 27.7 32.5 4.7 16.9 100±18 19.0
200 32.0 30.8 3.0 14.7 100±20 19.0
†3000 ft. put-up available in Black only. • Outer jacket is sunlight- and oil-resistant. • Jacket sequentially marked at 2 ft. intervals
250 36.4 29.3 — 12.8 100±20 18.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 350 44.3 27.2 — 9.9 100±22 17.0
RJ-45 Compatible • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 • P-07-KA060005-MSHA*
Oil Res I & II 11700A2 NEC: 4 1000 †† 304.8 42.0 19.1 .285 7.24 1 2.0 65.3 63.3 60.8 100±12 20.0
Upjacketed u CMR 2000 †† 609.6 86.0 39.1 4
8
4.0
5.7
56.3
51.8
52.3
46.1
48.7
42.7
100±12
100±12
23.0
24.5
CEC: Nominal 10 6.4 50.3 43.9 40.8 100±12 25.0
CMR FT4 Core OD: 16 8.1 47.3 39.1 36.7 100±12 25.0
.200 5.08 25 10.3 44.3 34.1 32.8 100±15 24.3
31.25 11.6 42.9 31.3 30.9 100±15 23.6
62.5 16.8 38.4 21.6 24.8 100±15 21.5
Rip Cord 100 21.7 35.3 17.1 20.8 100±15 20.1
††1000 ft. put-up available in Black or Blue only, 2000 ft. put-up in Black only. • RJ-45 Compatible • Outer jacket is sunlight resistant. 155 27.7 32.5 4.7 16.9 100±18 19.0
200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -10°C Cold Bend per UL1581 • Installation Temperature: +5°C to +75°C • Operating Temperature: -10°C to +75°C** 250 36.4 29.3 — 12.8 100±20 18.0
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 350 44.3 27.2 — 9.9 100±22 17.0
ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper
*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification. EtherNet/IP is a trademark of ControlNet International, Ltd.
**Subject to length de-rating. under license by Open DeviceNet Vendor Association, Inc.
DataTuff Color Codes: Pair 1 = White/Blue Stripe & Blue, Pair 2 = White/Orange Stripe & Orange, Pair 3 = White/Green Stripe & Green, Pair 4 = White/Brown Stripe & Brown
For two pair products: use color codes for Pairs 2 & 3

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.9

Industrial Data Solutions — Industrial Ethernet ®

®
Category 5e DataTuff Twisted Pair Cables, 2-Pair and 4-Pair
Heavy-Duty Sunlight and Oil-Resistant Jackets

Standard Nominal Max. Min. Min. Min.


UL NEC/ No. Standard Lengths Input Min.
Description
Part
C(UL) CEC of
Unit Wt. OD Freq. Atten. PSUM PSUM PSUM Imped. RL
No. (MHz) (dB/ NEXT ACR ELFEXT
Type Pairs Ft. m Lbs. kg Inch mm (dB/ (dB/ (Ω) (dB)
100m) (dB)
100m) 100m)

Enhanced Cat 5e • 22 AWG Bonded-Pairs Solid Bare Copper Conductors • Rip Cord • See Color Code Chart (below)
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket
PLTC 7922A NEC: 4 1000 304.8 46.3 21.0 .301 7.65 1 2.0 65.3 63.3 60.8 100±12 20.0
u PLTC, 2000 609.6 92.5 42.0 4
8
4.0
5.7
56.3
51.8
52.3
46.1
48.7
42.7
100±12
100±12
23.0
24.5
CMR, 10 6.4 50.3 43.9 40.8 100±12 25.0
CMX- 16 8.1 47.3 39.1 36.7 100±12 25.0
Outdoor 25 10.3 44.3 34.1 32.8 100±15 24.3
31.25 11.6 42.9 31.3 30.9 100±15 23.6
CEC: 62.5 16.8 38.4 21.6 24.8 100±15 21.5
CMR FT4 100 21.7 35.3 17.1 20.8 100±15 20.1
Rip Cord 155 27.7 32.5 4.7 16.9 100±18 19.0
200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -25°C Cold Bend per UL1581 • Installation Temperature: -10°C to +75°C • Operating Temperature: -25°C to +75°C** 250 36.4 29.3 — 12.8 100±20 18.0
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 350 44.3 27.2 — 9.9 100±22 17.0

Enhanced Cat 5e • 24 AWG Bonded-Pairs Stranded (7x32) TC Conductors • See Color Code Chart (below)
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red or Teal)
Stranded 7924A NEC: 4 1000 304.8 30.0 13.6 .242 6.15 1 2.4 65.3 62.9 60.8 100±12 20.0
4 4.8 56.3 51.5 48.7 100±12 23.6
Flexible CMR, 2000 † 609.6 58.0 26.3 8 6.8 51.8 45.0 42.7 100±12 25.4
CMX- 10 7.7 50.3 42.6 40.8 100±12 26.0
Outdoor 16 9.7 47.3 37.5 36.7 100±12 26.0
25 12.4 44.3 31.9 32.8 100±15 25.5
CEC: 31.25 13.9 42.9 29.0 30.9 100±15 25.0
CMR FT4 62.5 20.2 38.4 18.3 24.8 100±15 23.5
100 26.0 35.3 9.2 20.8 100±18 22.5
155 33.2 32.5 — 16.9 100±18 19.0
†2000 ft. put-up available in Black only. • RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals
200 38.4 30.8 — 14.7 100±20 19.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 250 43.7 29.3 — 12.8 100±20 18.0
Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151; 5,734,126 and 5,763,823 350 53.2 27.2 — 9.9 100±22 17.0

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC Conductors • Overall Beldfoil® Shield (100%) • Drain Wire • See Color Codes (below)
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red or Teal)
7933A NEC: 2 1000 304.8 32.0 14.5 .227 5.77 1 2.0 62.3 60.3 60.8 100±15 20.0
Compliant u CMR 2000 ▲ 609.6 64.8 29.4 4
10
4.1
6.5
53.3
47.3
49.2
40.8
48.7
40.8
100±15
100±15
23.6
26.0
Shielded CEC: 16 8.2 44.3 36.1 36.7 100±15 26.0
CMR FT4 31.25 11.7 39.9 28.2 30.9 100±15 25.0
62.5 17.0 35.4 18.4 24.8 100±15 23.5
100 22.0 32.3 10.3 20.8 100±15 22.5
Drain Wire 200 32.4 27.8 1.0 14.7 100±25 15.0

2000 ft. put-up available in Black only. • M-12 or RJ-45 Compatible • Shield is bonded to jacket inner wall for electrical stability.
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C**
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black or Blue)
Shielded 7929A NEC: 4 1000 304.8 37.0 16.8 .265 6.73 1 2.0 62.3 60.3 60.8 100±15 20.0
CMR, 2000 ▲ 609.6 72.0 32.7 4 4.1 53.3 49.2 48.7 100±15 23.0
10 6.5 47.3 40.8 40.8 100±15 25.0
CMX- 16 8.2 44.3 36.1 36.7 100±15 25.0
Outdoor 31.25 11.7 39.9 28.2 30.9 100±15 23.6
CEC: 62.5 17.0 35.4 18.4 24.8 100±15 21.5
Drain Wire 100 22.0 32.3 10.3 20.8 100±15 20.1
CMR FT4 200 32.4 27.8 1.0 14.7 100±25 15.0

2000 ft. put-up available in Black only. • RJ-45 Compatible • Shield is bonded to jacket inner wall for electrical stability.
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C**
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 • P-07-KA060003-MSHA*

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC Conductors • Overall Beldfoil (100%) + TC Braid Shield (70% Coverage) • Drain Wire◆
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red, Blue or Teal)
7921A NEC: 4 1000 304.8 55.0 24.9 .330 8.38 1 2.0 62.3 60.3 60.8 100±15 20.0
Compliant CMR, 2000 ▲ 609.6 106.0 48.1 4 4.1 53.3 49.2 48.7 100±15 23.6
Heavy-shielded CMX- 10 6.5 47.3 40.8 40.8 100±15 26.0
16 8.2 44.3 36.1 36.7 100±15 26.0
Outdoor 31.25 11.7 39.9 28.2 30.9 100±15 25.0
CEC: 62.5 17.0 35.4 18.4 24.8 100±15 23.5
CMR FT4 100 22.0 32.3 10.3 20.8 100±15 22.5

Drain Wire
18 • Industrial Cables


2000 ft. put-up available in Black only. ◆24 AWG solid spiral drain wire.
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C**
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • NEMA WC-63.1 Category 5e • U.S. Patents 5,606,151 and 5,734,126
ACR = Attenuation Crosstalk Ratio • AL = Aluminum • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper
EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.
*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification.
**Subject to length de-rating.

DataTuff Color Codes: Pair 1 = White/Blue Stripe & Blue, Pair 2 = White/Orange Stripe & Orange, Pair 3 = White/Green Stripe & Green, Pair 4 = White/Brown Stripe & Brown
For two pair products: use color codes for Pairs 2 & 3

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.10

Industrial Data Solutions — Industrial Ethernet ®

®
Category 5e DataTuff Twisted Pair Cables, 4-Pair
Heavy-Duty Sunlight and Oil-Resistant Jackets

Standard Nominal Max. Min. Min. Min.


UL NEC/ No. Standard Lengths Input Min.
Description
Part
C(UL) CEC of
Unit Wt. OD Freq. Atten. PSUM PSUM PSUM Imped. RL
No. (MHz) (dB/ NEXT ACR ELFEXT
Type Pairs Ft. m Lbs. kg Inch mm (dB/ (dB/ (Ω) (dB)
100m) (dB)
100m) 100m)

Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid BC Conductors • Polyester Wrap • Rip Cord • See Color Code Chart (below)
AL Interlocked Armor • Polyolefin Insulation • PVC Inner Jacket • .045″ Industrial Grade PVC Outer Jacket (Black or Gray)
Interlocked AL Armor 121700A NEC: 4 1000 304.8 159.0 72.0 .530 13.46 1 2.0 65.3 63.3 60.8 100±12 20.0
CM 3000 † 914.4 459.0 210.6 4 4.0 56.3 52.3 48.7 100±12 23.0
8 5.7 51.8 46.1 42.7 100±12 24.5
CEC: Nominal 10 6.4 50.3 43.9 40.8 100±12 25.0
HL Core OD: 16 8.1 47.3 39.1 36.7 100±12 25.0
CMG FT4 .200 5.08 25 10.3 44.3 34.1 32.8 100±15 24.3
31.25 11.6 42.9 31.3 30.9 100±15 23.6
Rip Cord 62.5 16.8 38.4 21.6 24.8 100±15 21.5
100 21.7 35.3 17.1 20.8 100±15 20.1
†3000 ft. put-up available in Black only. • RJ-45 Compatible • Outer jacket is sunlight- and oil-resistant. 155 27.7 32.5 4.7 16.9 100±18 19.0
200 32.0 30.8 3.0 14.7 100±20 19.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 250 36.4 29.3 — 12.8 100±20 18.0
Jacket sequentially marked at 1 meter intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 350 44.3 27.2 — 9.9 100±22 17.0
AL Interlocked Armor • Polyolefin Insulation • PVC Inner Jacket • .045″ Industrial Grade PVC Outer Jacket (Black or Blue)
Interlocked AL Armor 121700R NEC: 4 1000 304.8 159.0 72.0 .530 13.46 (Same as above)
-40°C Cold Impact u CM 3000 914.4 459.0 210.6
CEC: 5000 † 1524.0 690.0 313.0 Nominal
HL Core OD:
CMG FT4 .200 5.08
Rip Cord
†5000 ft. put-up available in Blue only. • RJ-45 Compatible • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C**
Outer jacket is sunlight- and oil-resistant. • Jacket sequentially marked at 1 meter intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126

Cat 5e • 24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black or Blue)
7918A NEC: 4 1000 304.8 28.0 12.7 1
.230 2.0
5.84 62.3 60.3 60.8 100±15 20.0
4 4.1 53.3 49.2 48.7 100±15 23.0
CMR, 2000 †† 609.6 52.0 23.6 10 6.5 47.3 40.8 40.8 100±15 25.0
CMX-Outdoor 16 8.2 44.3 36.1 36.7 100±15 25.0
CEC: 31.25 11.7 39.9 28.2 30.9 100±15 23.6
Rip Cord 62.5 17.0 35.4 18.4 24.8 100±15 21.5
CMR FT4 100 22.0 32.3 10.3 20.8 100±15 20.1
††2000 ft. put-up available in Black only. • RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals 200 32.4 27.8 1.0 14.7 100±25 15.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** • Third party verified to TIA/EIA-568-B.2, Category 5e

Cat 5e • 24 AWG Solid BC • Twisted Pairs • Overall Beldfoil® Shield (100% Coverage) • 24 AWG Stranded TC Drain Wire • See Color Code Chart
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black or Blue)
Shielded 7919A NEC: 4 1000 304.8 35.0 15.9 .265 6.73 1 2.0 62.3 60.3 60.8 100±15 20.0
4 4.1 53.3 49.2 48.7 100±15 23.0
CMR, 2000 † 609.6 68.0 30.9 10 6.5 47.3 40.8 40.8 100±15 25.0
CMX-Outdoor 16 8.2 44.3 36.1 36.7 100±15 25.0
CEC: 31.25 11.7 39.9 28.2 30.9 100±15 23.6
62.5 17.0 35.4 18.4 24.8 100±15 21.5
Drain Wire CMR FT4 100 22.0 32.3 10.3 20.8 100±15 20.1

†2000 ft. put-up available in Black only. • RJ-45 Compatible • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** • Cable passes -40°C Cold Bend per UL1581
Shield is bonded to jacket inner wall for electrical stability. • Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • P-07-KA060004-MSHA*

Cat 5e • 24 AWG Stranded (7x32) Bare Copper Conductors • Twisted Pairs • See Color Code Chart (below)
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket
Stranded/Flexible 7930A NEC: 4 1000 304.8 29.0 13.2 .240 6.09 1 2.5 62.3 59.8 60.8 100±15 20.0
u CMR, 2000 609.6 56.0 25.4 4
10
4.9
7.8
53.3
47.3
48.4
39.5
48.7
40.8
100±15
100±15
23.0
25.0
CMX-Outdoor 16 9.9 44.3 34.4 36.7 100±15 25.0
CEC: 31.25 14.1 39.9 25.8 30.9 100±15 23.6
62.5 20.4 35.4 15.0 24.8 100±15 21.5
CMR FT4 100 26.4 32.3 5.9 20.8 100±15 20.1
200 38.9 27.8 — 14.7 100±25 15.0
Installation Temperature: 0°C to +75°C • Operating Temperature: -25°C to +75°C** • Cable passes -25°C Cold Bend per UL1581
RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2, Category 5e • P-07-KA060003-MSHA*
ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • FEP = Fluorinated Ethylene-propylene •
NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper
EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc.
*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification.
**Subject to length de-rating.

Color Codes: DataTuff


Pair No. Color Combination
1 White/Blue Stripe & Blue
2 White/Orange Stripe & Orange
3 White/Green Stripe & Green
4 White/Brown Stripe & Brown
For two pair products: use color codes for Pairs 2 & 3

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.11

Industrial Data Solutions — Industrial Ethernet ®

®
Category 6 DataTuff Twisted Pair Cables, 4-Pair
Heavy-Duty Jackets

Standard Nominal Max. Min. Min. Min.


UL NEC/ No. Standard Lengths Input Min.
Description
Part
C(UL) CEC of
Unit Wt. OD Freq. Atten. PSUM PSUM PSUM Imped. RL
No. (MHz) (dB/ NEXT ACR ELFEXT
Type Pairs Ft. m Lbs. kg Inch mm (dB/ (dB/ (Ω) (dB)
100m) (dB)
100m) 100m)

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC Conductors • Patented E-Spline Center Member • Rip Cord • See Color Code Chart
Polyolefin Insulation • .030″ Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket
7927A NEC: 4 1000 304.8 44.0 20.0 .251 6.38 1 1.9 80.3 78.5 70.8 100±12 20.0
CMR 2000 609.6 88.0 39.9 x x 10 5.7 65.3 59.6 50.8 100±12 25.0
31.25 10.2 57.9 47.7 40.9 100±15 25.0
CEC: .339 8.61 62.5 14.7 53.4 38.7 34.9 100±15 25.0
CMR FT4 100 18.9 50.3 31.4 30.8 100±15 25.0
155 23.9 47.5 23.5 27.0 100±15 22.8
200 27.5 45.8 18.3 24.8 100±15 21.7
Rip Cord 250 31.2 44.3 13.2 22.8 100±20 20.5
350 37.7 40.2 4.5 19.9 100±22 19.8
400 40.6 39.3 0.6 18.8 100±22 19.5
RJ-45 Compatible • Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2-1, Category 6 500 46.2 37.8 >0.0 ◆ 16.8 100±22 18.4
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 550 48.8 37.2 — 16.0 100±22 18.0
◆PSUM ACR >0 is guaranteed to 460 MHz. • U.S. Patents 5,606,151; 5,734,126; 5,789,711 and 6,297,454-B1 600 51.4 36.6 — 15.2 100±22 17.6

Cat 6 • 23 AWG Bonded-Pairs Solid BC Conductors • See Color Code Chart (below)
Plenum • FEP Insulation • Sunlight-, Oil- and Gas-resistant Black FEP Jacket
High & Low Temp 7931A NEC: 4 1000 304.8 35.0 15.9 .214 5.44 1 2.0 72.3 70.3 64.8 100±15 20.0
Oil Res I & II Limited 10 6.0 57.3 51.3 44.8 100±15 25.0
20 8.5 52.8 44.3 38.7 100±15 25.0
Gas Res Combustible 31.25 10.7 49.9 39.2 34.9 100±15 23.6
FHC 25/50 62.5 15.4 45.4 30.0 28.8 100±15 21.5
CMP 100 19.8 42.3 22.5 24.8 100±15 20.1
200 29.0 37.8 8.8 18.7 100±22 18.0
CEC: 250 32.8 36.3 3.5 16.8 100±32 17.3
CMP FT6
RJ-45 Compatible
Cable passes -70°C Cold Bend per UL1581 • Installation Temperature: -55°C to +150°C • Operating Temperature: -70°C to +150°C**
Jacket sequentially marked at 2 ft. intervals • Third party verified to TIA/EIA-568-B.2-1, Category 6 • U.S. Patents 5,606,151 and 5,734,126

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC Conductors • Rip Cord • See Color Code Chart (below)
Polyolefin Insulation • PVC Inner Jacket • .035″ Industrial Grade PVC Outer Jacket (Black or Gray)
Upjacketed 11872A NEC: 4 1000 304.8 66.0 30.0 .475 12.07 1 1.9 72.3 70 64.8 100±12 20.0
CM x x 4 3.7 63.3 59 52.7 100±12 23.0
10 5.9 57.3 51 44.8 100±12 25.0
CEC: .265 6.73 16 7.5 54.3 46 40.7 100±12 25.0
CM 31.25 10.6 49.9 39 34.9 100±15 23.6
FT1 Nominal 62.5 15.4 45.4 30 28.8 100±15 21.5
100 19.8 42.3 25 24.8 100±15 21.0
Core OD: 155 25.1 39.5 14 20.9 100±15 21.0
Rip Cords .365 9.27 200 29.0 37.9 10 18.7 100±15 21.0
x x 310 37.1 34.9 — 14.9 100±20 18.0
350 39.8 34.2 — 13.9 100±22 17.0
†Value provided for information only. • RJ-45 Compatible • Cable passes -25°C Cold Bend per UL1581 .165 4.19 400 † 43.0 33.3 — 12.7 100±32 14.0
Installation Temperature: -10°C to +75°C • Operating Temperature: -25°C to +75°C** 500 † 49.0 31.8 — 10.8 100±32 14.0
Jacket sequentially marked at 2 ft. intervals • Verified to TIA/EIA-568-B.2-1, Category 6 • U.S. Patents 5,606,151, 5,734,126 and 5,821,467

Enhanced Cat 6 • 23 AWG Bonded-Pairs Solid BC Conductors • Polyester Wrap • Rip Cord • See Color Code Chart (below)
AL Interlocked Armor • Polyolefin Insulation • PVC Inner Jacket • .055″ Industrial Grade PVC Outer Jacket (Black or Gray)
Interlocked AL Armor 121872A NEC: 4 1000 304.8 222.0 100.6 .684 17.37 1 1.9 72.3 70 64.8 100±12 20.0
CM 4 3.7 63.3 59 52.7 100±12 23.0
10 5.9 57.3 51 44.8 100±12 25.0
CEC: Nominal 16 7.5 54.3 46 40.7 100±12 25.0
HL Core OD: 31.25 10.6 49.9 39 34.9 100±15 23.6
CMG FT4 .365 9.27 62.5 15.4 45.4 30 28.8 100±15 21.5
100 19.8 42.3 25 24.8 100±15 21.0
x x 155 25.1 39.5 14 20.9 100±15 21.0
Rip Cord .165 4.19 200 29.0 37.9 10 18.7 100±15 21.0
310 37.1 34.9 — 14.9 100±20 18.0
350 39.8 34.2 — 13.9 100±22 17.0
†Value provided for information only. • RJ-45 Compatible • Jacket sequentially marked at 1 meter intervals 400 † 43.0 33.3 — 12.7 100±32 14.0
Cable passes -40°C Cold Bend per UL1581 • Installation Temperature: -25°C to +75°C • Operating Temperature: -40°C to +75°C** 500 † 49.0 31.8 — 10.8 100±32 14.0
Verified to TIA/EIA-568-B.2-1, Category 6 • U.S. Patents 5,606,151, 5,734,126 and 5,821,467
ACR = Attenuation Crosstalk Ratio • AL = Aluminum • BC = Bare Copper • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • TC = Tinned Copper
**Subject to length de-rating.
18 • Industrial Cables

Color Codes: DataTuff


Pair No. Color Combination
1 White/Blue Stripe & Blue
2 White/Orange Stripe & Orange
3 White/Green Stripe & Green
4 White/Brown Stripe & Brown

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.12

Industrial Data Solutions — Industrial Ethernet ®

TrayOptic® Heavy-Duty, All-Dielectric Fiber Optic Cables


Loose Tube — Indoor/Outdoor Riser & Tray

Applications Specifications

■ Industrial and other harsh environment applications Temperature Range


Storage -40 to +70°C
■ Factory automation Operating -40 to +70°C
■ Direct burial Crush Resistance (EIA-455-41) 500 lbs./in. min.
Impact Resistance (EIA-455-25) 3.3 ft.-lbs./25 impacts min.
@ 2.2N-m
Product Description
Cyclic Flexing (EIA-455-104) 25 cycles, 12 lbs.,
Laser Optimized Fiber to handle Gigabit Ethernet light sources and 20 x OD radius min.
expanded bandwidth requirements. Passes IEEE 383-2003 flame Min. Bend Radius
test. Waterblocking agent for moisture protection. CPE outer jacket Installation 20 x OD
option provides extra chemical or abrasion resistance. Long Term 15 x OD
Maximum Installation Load 600 lbs. (2700 N)
Jacket Material PVC or CPE Optical Specifications See page 10.2
Strength Member Aramid Yarn
Jacket Color Orange Fiber Bundle Detail

Outer Jacket Aramid Strength


Ratings Member
Inner Jacket
Riser
UL Type OFNR
Waterblocking
cUL Type OFN FT4
Agent
Flame Resistance IEEE 383-2003
Optical
Fibers
Binder

Gel-filled
Buffer Tube
Dielectric Central
Strength Member

No. Fibers Outside Diameter PVC Jacket CPE Jacket


of Per Weight Weight Weight Weight
Fibers Tube Inches mm Belden Part No. Lbs./1000′′ Belden Part No. Lbs./1000′′
kg/km kg/km

TrayOptic Series
Riser (NEC/CEC OFNR/OFN FT4)
2 2 0.440 11.18 I100255 88 131 I100266 83 124
4 4 0.440 11.18 I100455 88 131 I100466 83 124
6 6 0.440 11.18 I100655 88 131 I100666 83 124
8 4 0.440 11.18 I400855 88 131 I400866 83 124
12 6 0.440 11.18 I601255 88 131 I601266 83 124
18 6 0.440 11.18 I601855 88 131 I601866 83 124
24 6 0.440 11.18 I602455 88 131 I602466 83 124
36 6 0.440 11.18 I603655 88 131 I603666 83 124
48 12 0.540 13.72 I604855 136 202 I604866 129 192
60 12 0.540 13.72 I606055 136 202 I606066 129 192
72 12 0.540 13.72 I607255 136 202 I607266 129 192
All optical fiber products can be supplied in compliance with RoHS regulations. Please contact Customer Service for more details.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.13

Industrial Data Solutions — Industrial Ethernet ®

Coaxial Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

Thinnet 10Base2 Ethernet • 20 AWG Stranded (19x32) .037″ TC Conductor • Duobond® II (100% Coverage) + TC Braid (93% Coverage)
Foam Polyethylene Insulation • Gray PVC Jacket
UL AWM 9907 NEC: 500 152.4 12.5 5.7 20 AWG .102 2.59 Duobond II .185 4.70 50 80% 25.4 83.3 1 .43 1.4
Style 1354 CL2 U-1000 U-304.8 25.0 11.4 (19x32) + 93% 10 1.30 4.3
(30V 60°C) CM 1000 304.8 25.0 11.4 .037″ TC Braid 50 2.90 9.5
CEC: 1640 500.0 41.0 18.6 TC 5.8Ω/M′ 100 4.20 13.8
For Plenum versions of 9907, 200 6.10 20.0
CM U-2500 U-762.0 60.0 27.3 8.8Ω/M′ 19.0Ω/km see 89907 or 82907. 400 8.90 29.2
2500 762.0 62.5 28.4 28.9Ω/km 700 12.10 39.7
3280 1000.0 82.0 37.3 900 13.90 45.6
DEC Part No. 17-01248-00 1000 14.80 48.6
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C 89907 NEC: 500 152.4 13.0 5.7 20 AWG .095 2.41 Duobond II .160 4.06 50 80% 25.4 83.3 1 .43 1.4
CL2P 1000 304.8 24.0 10.9 (19x32) + 93% 10 1.30 4.3
CMP 2500 † 762.0 60.0 27.3 .037″ TC Braid 50 2.90 9.5
CEC: TC 5.8Ω/M′ 100 4.18 13.8
200 6.10 20.0
CMP FT6 8.8Ω/M′ 19.0Ω/km 400 9.20 30.2
RG-58/U Type 28.9Ω/km 700 12.90 42.3
DEC Part No. 17-01246-00 900 15.00 49.2
Suitable for Outdoor and Direct Burial applications. 1000 16.00 52.5

Thicknet 10Base5 Ethernet • 12 AWG Solid .086″ Bare Copper Conductor • Duobond IV* Quad Shield (100% Coverage)
Foam Polyethylene Insulation • Yellow PVC Jacket
UL AWM 9880 NEC: 500 152.4 66.0 30.0 12 AWG .243 6.17 Duobond IV .405 10.29 50 78% 26.0 85.0 1 .19 .62
Style 1478 CL2 1000 304.8 131.0 59.5 (solid) (Duobond II 5 .37 1.21
(30V 60°C) CM 1640 500.0 219.0 99.9 .086″ + 94% TC Braid 10 .52 1.71
CEC: BC + Duofoil ® 50 1.20 3.94
For Plenum version of 9880, 100 1.70 5.58
CM 1.4Ω/M′ + 90% TC 200 2.55 8.37
4.7Ω/km Braid) see 89880. 400 3.90 12.80
1.5Ω/M′ 700 5.50 18.10
DEC Part No. 17-00451-00 5.0Ω/km 900 6.50 21.30
Ring-band stripes marked every 2.5 meters to aid users in tap placement. 1000 6.90 22.60
Plenum • Foam FEP Insulation • Orange Fluorocopolymer Jacket
150°C 89880 NEC: 1000 304.8 134.0 60.9 12 AWG .245 6.22 Duobond IV .375 9.53 50 78% 26.0 85.0 1 .18 .59
CL2P 1640 † 500.0 224.7 102.1 (solid) (Duobond II 5 .37 max. 1.21
CMP .086″ + 90% TC Braid 10 .52 max. 1.71
CEC: BC + Duofoil 50 1.15 3.77
100 1.65 5.41
CMP FT6 1.4Ω/M′ + 90% TC 200 2.45 8.04
4.7Ω/km Braid) 400 3.80 12.50
DEC Part No. 17-00324-00 1.5Ω/M′ 700 5.60 18.40
Ring-band stripes marked every 2.5 meters to aid users in tap placement. 5.0Ω/km 900 6.80 22.30
Suitable for Outdoor and Direct Burial applications. 1000 7.20 23.60
BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene • TC = Tinned Copper
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1.
*Duobond IV = Duobond II + 94% tinned copper braid + Duofoil ® + 90% tinned copper braid.
(Plenum version is Duobond II + 90% tinned copper braid + Duofoil + 90% tinned copper braid.)
† Spools and/or UnReel® cartons are one piece, but length may vary ±10% from length shown.

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.14

Industrial Data Solutions — Industrial Twinax ®

Belden® Blue Hose® Selection Guide for PLC and DCS Applications

Part No. Description Specifications

9463 Blue Hose Standard Data Highway Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
A Standard Data Highway Cable that is sometimes referred to as Blue (color coded Blue, Clear), Beldfoil® + 55% tinned copper braid and drain
Hose. Designed to be used in light industrial environments. Available wire, Blue sunlight-resistant PVC jacket. Nominal diameter: .238″.
in Blue, Brown or Orange up to 10,000 ft. special lengths.
3072F 600V Data Highway Cable — UL Type TC 1-pair, 18 AWG stranded (7x26) tinned copper, flame-retardant
A DataTray® cable designed for cable tray use in industrial applications. polyolefin insulation (color coded Blue, White), Beldfoil + 55% tinned
Cable can occupy same tray or conduit as 600V power cables. copper braid and drain wire, Blue sunlight-resistant PVC jacket.
Nominal diameter: .324″. UL-1277 600V TC/PLTC/ITC/CMG.
9463F High-Flex Cable 1-pair, 20 AWG stranded (42x36) tinned copper, polyethylene insulation
A highly flexible version of the standard Blue Hose cable. The cable (color coded Blue, Clear), Beldfoil + 85% tinned copper braid,
also has heavier braid coverage for better noise immunity. Blue sunlight-resistant PVC jacket. Nominal diameter: .243″.

YR28826* Dual Blue Hose Cable 2-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
Dual Data Highway/Remote I/O cable has two Twinax pairs individually (color coded Blue, Clear), each pair Beldfoil shielded (1 pair Blue tape
shielded with an overall braid. Designed for use in daisy chain and 1 pair Green tape), 85% tinned copper braid and drain wire,
applications or applications requiring two Blue Hose cables. Blue PVC jacket. Nominal diameter: .382″.

YC39151* Dual Armored Data Highway Cable 2-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
Features two twinax pairs individually shielded with an overall braid, an (color coded Blue, Clear), each pair Beldfoil shielded, 55% tinned copper
inner PVC jacket, aluminum interlocked armor, with an outer PVC jacket. braid and drain wire, Blue PVC inner jacket, aluminum interlocked armor,
Designed for use in daisy chain applications or applications requiring Blue sunlight-resistant PVC outer jacket. Nominal diameter: .820″.
two Blue Hose cables, with the extra mechanical protection and
electrical shielding provided by the armor.
9463DB Gel-Filled Direct Burial Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
A gel-filled Blue Hose cable featuring a low-density polyethylene (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and drain
(LDPE) jacket. Especially suited for high-moisture environments and wire, CoreGuard® flooding compound, Blue sunlight-resistant low density
burial applications. polyethylene jacket. Nominal diameter: .240″.
89463 Plenum Cable 1-pair, 20 AWG stranded (7x28) tinned copper, FEP insulation (color
A plenum, 200°C grade cable that is suitable for installations where coded Blue, Clear), Beldfoil + 76% tinned copper braid and drain wire,
high and low temperatures, as well as corrosive environments, Blue FEP jacket. Nominal diameter: .203″.
are encountered.
YR28764* Thick-Wall, Heavy-Duty Cable — UL Type PLTC 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
A rugged, heavy-duty cable specially designed for abusive environments. (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and
A .069″ thick jacket provides extra protection against cuts and abrasion. drain wire, Blue sunlight-resistant PVC jacket. Nominal diameter: .380″.
YR41104* Low Smoke, Zero Halogen Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
For applications concerned with smoke emissions, toxicity and (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and
electronic component corrosion. drain wire, Blue Haloarrest® jacket. Nominal diameter: .256″.
129463 Aluminum Interlocked Armor Blue Hose Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
Features interlocked aluminum armor combined with a PVC jacket and (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and drain
is an ideal alternative to conduit installation. Provides both mechanical wire, Blue PVC inner jacket, aluminum interlocked armor, Blue PVC sun-
protection and electrical shielding. Up to 25 Data Highway cables can light-resistant outer jacket. Nominal overall diameter: .563″.
be bundled under one sheath.
139463 Steel Interlocked Armor Blue Hose Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
Features interlocked galvanized steel armor combined with a PVC jacket. (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and drain
Provides mechanical protection and electrical shielding, as well as wire, Blue PVC inner jacket, steel interlocked armor, Blue sunlight-
prevention against the low-frequency 60 Hz magnetic noise from power resistant outer PVC jacket. Nominal overall diameter: .563″.
lines. Up to 25 cables can be bundled under one sheath.
189463 Continuously Corrugated Aluminum Armor Blue Hose Cable 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
Features continuously corrugated aluminum armor combined with (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and drain
a PVC jacket. Provides mechanical protection, electrical shielding wire, Blue PVC inner jacket, continuously corrugated aluminum armor,
and is impervious to moisture. Blue sunlight-resistant PVC outer jacket. Nominal overall diameter: .500″.
YR29565* Colored Blue Hose 1-pair, 20 AWG stranded (7x28) tinned copper, polyethylene insulation
When your application calls for multiple Blue Hose cables you can (color coded Blue, Clear), Beldfoil + 55% tinned copper braid and
rest assured that Belden has the solution. This special construction drain wire, sunlight-resistant PVC jacket. Nominal diameter: .238″.
is available in Red, Yellow, Green, White or Pink.
*Custom made product. Minimum order quantity may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.15

Industrial Data Solutions — Industrial Twinax ®

Blue Hose® Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

78 Ohm • 20 AWG Stranded (7x28) .038″ TC Conductors • Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) • TC Drain Wire
Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue)
Blue Hose 9463 NEC: 100 30.5 4.2 1.9 20 AWG .154 3.91 Beldfoil .238 6.05 78 66% 19.7 64.6 1 .6 2.0
UL AWM CM CL2 U-500 U-152.4 18.5 8.4 (7x28) +55% 10 2.1 6.9
Style 2464 CEC: 500 152.4 18.5 8.4 .038″ TC Braid 50 5.0 16.4
(300V 80°C) CM U-1000 U-304.8 37.0 16.8 Tinned 4.1Ω/M′ 100 7.5 24.6
▲ 200 11.0 36.1
1000 304.8 37.0 16.8 Copper 13.4Ω/km 400 16.0 52.5
Z- Fold® 6000 ▲ † 1828.8 222.0 100.9 9.5Ω/M′
◆†
10000 3048.0 370.0 168.0 31.0Ω/km
CPE jacket optional.

Drain Wire

Allen-Bradley P/N 1770-CD • P-7K-SC-182141-MSHA*



1000 ft. and 6000 ft. put-ups also available in Brown, Orange or Purple.

10000 ft. put-up available in Brown or Orange only.

Final put-up length may vary ±10% from length shown.)

Polyethylene Insulation • Blue Sunlight-resistant LDPE Jacket (Color Code: Clear, Blue)
Flooded 9463DB — 1000 304.8 33.0 15.0 20 AWG .154 3.91 Beldfoil .240 6.10 78 66% 19.7 64.6 1 .6 2.0
Direct Burial 5000 1524.0 155.0 70.4 (7x28) +55% 10 2.1 6.9
Blue Hose .038″ TC Braid 50 5.0 16.4
300V 80°C Tinned 4.1Ω/M′ 100 7.5 24.6
200 11.0 36.1
Z- Fold® Copper 13.4Ω/km 400 16.0 52.5
9.5Ω/M′
31.0Ω/km

Drain Wire
Allen-Bradley P/N 1770-CD

78 Ohm • 20 AWG Stranded (42x36) .038″ TC Conductors • Overall Beldfoil (100% Coverage) + TC Braid Shield (85% Coverage)
Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue)
High-Flex 9463F NEC: 1000 304.8 42.0 19.1 20 AWG .154 3.91 Beldfoil .243 6.17 78 66% 19.7 64.6 1 .6 2.0
Blue Hose CM CL2 5000 1524.0 205.0 93.1 (42x36) +85% 10 2.1 6.9
UL AWM CEC: .038″ TC Braid 50 5.0 16.4
Style 2464 CM Tinned 5.0Ω/M′ 100 7.5 24.6
200 11.0 36.1
(300V 60°C) Copper 6.4Ω/km 400 16.0 52.5
9.5Ω/M′
31.0Ω/km

Allen-Bradley P/N 1770-CD • P-7K-SC-182141-MSHA*

78 Ohm • 20 AWG Stranded (7x28) .038″ TC Conductors • Overall Beldfoil (100% Coverage) + TC Braid Shield (76% Coverage) • Drain Wire
Plenum • FEP Insulation • Blue FEP Jacket (Color Code: Clear, Blue)
High 89463 NEC: 1000 304.8 34.0 15.4 20 AWG .151 3.83 Beldfoil .203 5.16 78 69% 19.7 64.6 1 .6 2.0
Temperature CMP CL2P 2500 762.0 90.0 40.9 (7x28) +76% 10 2.1 6.9
Blue Hose CEC: .038″ TC Braid 50 5.0 16.4
300V 200°C CMP FT6 Tinned 4.1Ω/M′ 100 7.5 24.6
200 11.0 36.1
Z- Fold® Copper 13.4Ω/km 400 16.0 52.5
9.5Ω/M′
31.0Ω/km

Drain Wire
Allen-Bradley P/N 1770-CD
18 • Industrial Cables

DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene • LDPE = Low-density Polyethylene • TC = Tinned Copper
*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.16

Industrial Data Solutions® — Industrial Twinax


Blue Hose® and Other Twinaxial Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

78 Ohm • 20 AWG Stranded (7x28) TC Conductors • Overall Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) • TC Drain Wire
Aluminum Interlocked Armor • PE Insulation • Blue Sunlight-resistant PVC Outer Jacket* (Color Code: Clear, Blue)
Aluminum 129463 NEC: 1000 † 304.8 122.0 55.5 20 AWG .154 3.91 Beldfoil Inner Jacket: 78 66% 19.7 64.6 1 .6 2.0
Armored CM CL2 6000 † 1828.8 924.0 420.0 (7x28) +55% .238 6.05 10 2.1 6.9
Blue Hose CEC: .038″ TC Braid 50 5.0 16.4
300V 60°C CM, Tinned 4.1Ω/M′ Overall:
100 7.5 24.6
200 11.0 36.1
CMG FT4, Copper 13.4Ω/km .563 14.30 400 16.0 52.5
HLBCD 9.5Ω/M′
(Haz Loc) 31.0Ω/km

Drain Wire

*Blue PVC inner jacket.


Allen-Bradley P/N 1770-CD

Steel Interlocked Armor • PE Insulation • Blue Sunlight-resistant PVC Outer Jacket* (Color Code: Clear, Blue)
Steel 139463 NEC: 1000 † 304.8 220.0 100.0 20 AWG .154 3.91 Beldfoil Inner Jacket: 78 66% 19.7 64.6 1 .6 2.0
Armored CM CL2 6000 † 1828.8 1488.0 676.4 (7x28) +55% .238 6.05 10 2.1 6.9
Blue Hose CEC: .038″ TC Braid 50 5.0 16.4
300V 60°C CM, Tinned 4.1Ω/M′ Overall:
100 7.5 24.6
200 11.0 36.1
CMG FT4, Copper 13.4Ω/km .563 14.30 400 16.0 52.5
HLBCD 9.5Ω/M′
(haz loc) 31.0Ω/km
Drain Wire
*Blue PVC inner jacket.
Allen-Bradley P/N 1770-CD

Continuously Corrugated AL Armor • PE Insulation • Blue Sunlight-resistant PVC Outer Jacket* (Color Code: Clear, Blue)
Continuously 189463 NEC: 2000 † 609.6 258.0 117.1 20 AWG .154 3.91 Beldfoil Inner Jacket: 78 66% 19.7 64.6 1 .6 2.0
Armored PLTC (7x28) +55% .238 6.05 10 2.1 6.9
Blue Hose .038″ TC Braid 50 5.0 16.4
300V 60°C Tinned 4.1Ω/M′ Overall:
100 7.5 24.6
200 11.0 36.1
Copper 13.4Ω/km .500 12.70 400 16.0 52.5
9.5Ω/M′
31.0Ω/km
Drain Wire

*Blue PVC inner jacket.


Allen-Bradley P/N 1770-CD

78 Ohm • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductors • Tinned Copper Braid Shield (93% Coverage)
Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue)
UL AWM 9272 NEC: 100 30.5 4.5 2.0 20 AWG .156 3.96 93% .244 6.20 78 66% 19.7 64.6 1 .6 2.0
Style 2092 CM U-500 U-152.4 20.5 9.3 (7x28) TC Braid 10 2.1 6.9
(300V 60°C) CEC: 500 152.4 20.0 9.1 .038″ Shield 50 5.0 16.4
CM U-1000 U-304.8 41.0 18.6 Tinned 3.4Ω/M′ For Plenum version of 9272, 100 7.5 24.6
see 89272. 200 11.0 36.1
1000 304.8 40.0 18.2 Copper 11.2Ω/km 400 16.0 52.5
9.5Ω/M′ CPE jacket optional.
31.0Ω/km

95 Ohm • RG-22B/U Type • 18 AWG Stranded (7x26) Bare Copper Conductors†† • TC Double Braid Shield (95% Coverage)
Polyethylene Insulation • PE Inner Jacket • Black Non-contaminating PVC Outer Jacket
80°C 9250 — 500 152.4 61.5 27.9 18 AWG .285 7.24 2 .416 10.57 95 66% 16.0 52.5 1 .3 1.0
VW-1 1000 304.8 121.0 54.9 (7x26) TC Braid 10 .9 3.0
.046″ 95% 20 1.3 4.3
BC Shield 50 2.1 6.9
CPE jacket optional. 100 3.0 9.8
6.6Ω/M′ .9Ω/M′ 400 6.3 20.7
21.5Ω/km 3.0Ω/km
††One conductor has tinned center strand.
AL = Aluminum • BC = Bare Copper • DCR = DC Resistance • PE = Polyethylene • TC = Tinned Copper

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.17

Industrial Data Solutions® — Industrial Twinax


Twinaxial Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

100 Ohm • 20 AWG Stranded (7x28) .037″ One TC, One BC Conductor • Duofoil® (100% Coverage) + TC Braid Shield (86% Coverage)
Polyethylene Insulation • Polyethylene Inner Jacket • Black PVC Outer Jacket
75°C 9207 NEC: 100 30.5 7.1 3.2 20 AWG .236 5.99 Duofoil .330 8.38 100 66% 14.5 47.6 1 .3 1.0
CMG CL2 U-500 U-152.4 34.0 15.5 (7x28) + 86% 10 1.2 3.9
CEC: 500 152.4 34.5 15.7 .037″ TC Braid 50 2.8 9.2
CMG FT4 1000 304.8 68.0 30.9 1 TC 2.5Ω/M′ For Plenum version of 9207, 100 4.1 13.5
see 89207. 200 6.4 21.0
1640 500.0 111.5 50.7 1 BC 8.2Ω/km 400 10.2 33.5
2000 609.6 136.0 61.8 9.5Ω/M′ CPE jacket optional.
3280 1000.0 219.8 99.9 31.0Ω/km
IBM P/N 7362211 5000 1524.0 350.0 159.1

124 Ohm • 25 AWG Stranded (7x33) .021″ Tinned Copper Conductors • Beldfoil® (100% Coverage) • Stranded Tinned Copper Drain Wire
Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue)
UL AWM 9271 NEC: 100 30.5 3.2 1.5 25 AWG .170 4.32 100% .240 6.10 124 66% 12.2 40.0 1 .6 2.0
Style 2092 CM 500 152.4 14.0 6.4 (7x33) Beldfoil 10 1.7 5.6
(300V 60°C) CEC: U-1000 U-304.8 27.0 12.3 .021″ Shield 50 3.6 11.8
CM 1000 304.8 28.0 12.7 Tinned 12.0Ω/M′ 100 5.0 16.4
200 6.9 22.6
Copper 39.4Ω/km CPE jacket optional. 400 9.6 31.5
31.8Ω/M′
104.3Ω/km
Shorting Fold

124 Ohm • 16 AWG Solid .051″ Bare Copper Conductors • Duofoil (100% Coverage) + Tinned Copper Braid Shield (90% Coverage)
Foam Polyethylene Insulation • Black PVC Jacket (Color Code: Clear, Blue)
UL AWM 9860 NEC: 500 152.4 52.0 23.6 16 AWG .322 8.18 Duofoil .440 11.18 124 78% 10.9 35.8 1 .2 .6
Style 2448 CMX 1000 304.8 103.0 46.8 (solid) +90% 10 .7 2.3
(30V 60°C) CEC: 2000 609.6 202.0 91.8 .051″ TC Braid 50 1.8 5.9
CMX Bare 1.3Ω/M′ 100 2.9 9.5
CPE jacket optional. 200 4.1 13.5
Copper 4.3Ω/km 400 6.2 20.3
4.2Ω/M′
13.8Ω/km

150 Ohm • 22 AWG Stranded (19x34) .031″ Tinned Copper Conductors • Duofoil (100% Coverage) • Stranded Tinned Copper Drain Wire
Datalene® Insulation • Black PVC Jacket (Color Code: Black, Yellow)
UL AWM 9182 NEC: U-500 U-152.4 22.5 10.2 22 AWG .275 6.98 100% .345 8.76 150 78% 8.8 28.9 1 .4 1.3
Style 2668 CL2X CMX 500 152.4 23.0 10.4 (19x34) Duofoil 10 1.2 3.9
(30V 60°C) CEC: 1000 304.8 44.0 20.0 .031″ Shield For Plenum version of 9182, 50 2.7 8.9
VW-1 CMX Tinned 6.3Ω/M′ see 89182. 100 4.3 14.1
200 6.2 20.3
Copper 20.7Ω/km Dual version: YR41609 400 8.8 28.9
14.0Ω/M′
45.9Ω/km CPE jacket optional.

Plenum • Foam FEP Teflon® Insulation • Black FEP Teflon Jacket (Color Code: Black, Yellow)
89182 NEC: 100 30.5 6.4 2.9 22 AWG .278 7.06 100% .307 7.80 150 78% 8.8 28.9 1 .4 1.3
CMP 500 † 152.4 28.0 12.7 (19x34) Duofoil 10 1.2 3.9
CL2P 1000 † 304.8 53.0 24.1 .031″ Shield 50 2.7 8.9
CEC: Tinned 6.3Ω/M′ 100 4.3 14.1
200 6.2 20.3
CMP FT6 Copper 20.7Ω/km 400 8.8 28.9
14.0Ω/M′
45.9Ω/km

BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene • TC = Tinned Copper


†Spools are one piece, but length may vary ±10% from length shown.
Teflon is a DuPont trademark.
18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.18

Industrial Data Solutions® — Industrial Twinax


DataTray® 600V Twinaxial Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

18 AWG Stranded (7x26) Tinned Copper Conductors • Overall Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) • TC Drain Wire
Flame-retardant Polyolefin Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Natural, Blue)
UL Type TC 3072F NEC: 250 76.2 17.5 8.0 18 AWG .192 4.88 Beldfoil .324 8.23 78 65% 19.5 64 1 .5 1.7
600V 75°C CMG, ITC 500 152.4 35.0 15.9 (7x26) +55% 10 2.0 6.5
TC, PLTC 1000 304.8 69.0 31.3 .046″ TC Braid 50 3.8 12.4
Z- Fold® CEC: 2500 762.0 170.0 77.2 Tinned (100% 100 5.4 17.6
† 200 7.6 24.8
CMG FT4 5000 1524.0 345.0 156.6 Copper Shield) For CPE jacketed version 400 10.7 35.1
10000 † 3048.0 710.0 322.3 6.9Ω/M′ 3.2Ω/M′ order Part No. YM45044.
22.7Ω/km 10.4Ω/km
Drain Wire
P-MSHA-C-7K-1827*

UL Type TC 3073F NEC: 250 76.2 21.0 9.5 18 AWG .246 6.25 Beldfoil .388 9.86 100 65% 15.3 50.2 1 .4 1.3
600V 75°C CMG, ITC 1000 304.8 85.0 38.6 (7x26) +55% 10 1.3 4.4
TC, PLTC 5000 † 1524.0 420.0 190.7 .046″ TC Braid 50 3.0 9.7
Z- Fold® CEC: Tinned (100% 100 4.2 13.8
200 6.0 19.5
CMG FT4 Copper Shield) 400 7.5 24.7
6.9Ω/M′ 2.9Ω/M′ CPE jacket optional.
22.7Ω/km 9.6Ω/km
Drain Wire

UL Type TC 3074F NEC: 500 152.4 62.5 28.4 18 AWG .328 8.33 Beldfoil .460 11.68 124 65% 12.3 40.3 1 .3 1.1
600V 75°C CMG, ITC 1000 304.8 121.0 54.9 (7x26) +55% 10 1.1 3.5
TC, PLTC 2500 762.0 300.0 136.2 .046″ TC Braid 50 2.4 7.8
CEC: Tinned (100% 100 3.4 11.1
Z- Fold® 200 4.8 15.7
CMG FT4 Copper Shield) 400 6.8 22.2
6.9Ω/M′ 2.8Ω/M′ CPE jacket optional.
22.7Ω/km 9.1Ω/km
Drain Wire

DCR = DC Resistance • TC = Tinned Copper if conductor, or Tray Cable if NEC rating.


*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration certification.

Final put-up length may vary -0 to +10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.19

Industrial Data Solutions® — Industrial Coax


ControlNet™ Quad Shielded Coax

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

RG-6/U Type • 18 AWG Solid Bare Copper-covered Steel Conductor • Duobond® IV* Quad Shield (100% Coverage)
Foam Polyethylene Insulation • PVC Jacket (Black or Intrinsically Safe Blue)
3092A NEC: 500 152.4 20.0 9.1 18 AWG .180 4.57 Duobond IV .298 7.57 75 82% 16.2 53.1 1 .35 1.1
CL2R CMR 1000 304.8 39.0 17.7 (solid) Quad 2 .38 1.2
CEC: 2000 609.6 78.0 35.4 .040″ Shield 5 .45 1.5
CMG FT4 2500 762.2 92.5 42.0 BCCS 3.6Ω/M′ 10 .59 1.9
Sweep tested 5 MHz to 50 MHz. 20 .86 2.8
28.0Ω/M′ 11.8Ω/km 50 1.37 4.5
91.8Ω/km CPE jacket optional. 100 1.97 6.5
200 2.82 9.3
300 3.48 11.4
Allen-Bradley P/N 1786 400 4.04 13.3
Plenum • Foam FEP Insulation • Fluorocopolymer Jacket (Black or Intrinsically Safe Blue◆)
150°C 3093A NEC: 1000 ◆ 304.8 40.0 18.2 18 AWG .170 4.32 Duobond IV .274 6.96 75 82% 16.3 53.5 1 .36 1.2
CMP 2000 † 609.6 80.0 36.3 (solid) Quad 2 .38 1.2
CEC: 2500 † 762.0 95.0 43.1 .040″ Shield 5 .50 1.6
CMP FT6 BCCS 3.6Ω/M′ 10 .65 2.1
20 .95 3.1
28.0Ω/M′ 11.8Ω/km Sweep tested 5 MHz to 50 MHz. 50 1.50 4.9
91.8Ω/km 100 2.12 7.0
200 2.99 9.8

Blue available as standard in 1000 ft. only. 300 3.66 12.0
Suitable for Outdoor and Direct Burial applications. • Allen-Bradley P/N 1786 400 4.23 13.9

RG-6/U Type • 20 AWG Stranded (105x40) Bare Copper Conductor • Duobond IV* Quad Shield (100% Coverage)
Foam Polyethylene Insulation • Black PVC Jacket
High-Flex 3092F NEC: 1000 304.8 44.0 20.0 20 AWG .183 4.65 Duobond IV .303 7.70 75 79% 17.0 55.8 1 .36 1.2
CL2R CMR 5000 1524.0 220.0 99.8 (105x40) Quad 2 .47 1.5
CEC: .040″ Shield 5 .80 2.6
Sweep tested 5 MHz to 400 MHz. 10 1.20 3.9
CMG Bare 3.6Ω/M′
CPE jacket optional. 20 2.00 6.6
FT4 Copper 11.8Ω/km 50 3.20 10.5
10.5Ω/M′ 123092F — Aluminum Armor 100 4.60 15.1
34.4Ω/km 133092F — Steel Armor 200 6.50 21.3
IEEE 802.4 MAP/IEEE 802.7 Mini-MAP. • Allen-Bradley P/N 1786 300 8.00 26.2
For Rockwell authorized Flexible ControlNet order YR28890 (Tinned Copper Braid version). 400 9.30 30.5

RG-6/U Type • 18 AWG Solid Bare Copper-Covered Steel Conductor • Duobond IV* Quad Shield (100% Coverage)
Aluminum Interlocked Armor • Foam Polyethylene Insulation • PVC Inner Jacket • Black PVC Sunlight Resistant Outer Jacket
75°C 123092A NEC: 1000 †† 304.8 180.0 81.7 18 AWG .180 4.57 Duobond IV Inner Jacket 75 82% 16.2 53.2 1 .35 1.2
u CM (solid) Quad .298 7.57 2 .38 1.3
CEC: .040″ Shield Overall: 5 .45 1.5
CMG, BCCS 3.6Ω/M′ .620 15.75 10 .59 1.9
20 .86 2.8
FT4, HL 28.0Ω/M′ 11.8Ω/km 50 1.37 4.5
91.9Ω/km 100 1.97 6.5
Sweep tested 5 MHz to 50 MHz.
200 2.82 9.3
CPE jacket optional. 300 3.48 11.4
133092A — Steel Armor 400 4.04 13.3
Allen-Bradley P/N 1786
Jacket sequentially marked at 1 meter intervals.

Continuously Corrugated Aluminum Armor • Foam Polyethylene Insulation • PVC Inner Jacket • Black PVC Outer Jacket
75°C 183092A NEC: 2000 ▲ 609.6 350.0 158.9 18 AWG .180 4.57 Duobond IV Inner Jacket 75 82% 16.2 53.2 1 .35 1.2
u CL2, CM (solid) Quad .298 7.57 2 .38 1.3
.040″ Shield Overall: 5 .45 1.5
BCCS 3.6Ω/M′ .570 14.48 10 .59 1.9
20 .86 2.8
28.0Ω/M′ 11.8Ω/km 50 1.37 4.5
91.9Ω/km 100 1.97 6.5
Sweep tested 5 MHz to 50 MHz. 200 2.82 9.3
Allen-Bradley P/N 1786 300 3.48 11.4
Jacket sequentially marked at 2 ft. intervals. 400 4.04 13.3
BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene
18 • Industrial Cables

*Duobond IV Quad Shield = Duobond II Foil + 60% aluminum braid + Duofoil + 40% aluminum braid.

Final put-up length may vary 0 to +10% from length shown.
††
Final put-up length may vary ±5% from length shown.

Final put-up length may vary ±10% from length shown.

ControlNet is a ControlNet International trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.20

Industrial Data Solutions® — Industrial Coax


ControlBus™ Quad Shielded Coax

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

RG-6/U Type • 20 AWG Stranded (105x40) Bare Copper Conductor • Duobond® IV* Quad Shield (100% Coverage)
Foam Polyethylene Insulation • Black PVC Jacket
High-Flex 3092F NEC: 1000 304.8 44.0 20.0 20 AWG .183 4.65 Duobond IV .303 7.70 75 79% 17.0 55.8 1 .36 1.2
CL2R CMR 5000 1524.0 225.0 102.2 (105x40) Quad 2 .47 1.5
CEC: .040″ Shield 5 .80 2.6
CMG Bare 3.6Ω/M′ 10 1.20 3.9
Sweep tested 5 MHz to 400 MHz. 20 2.00 6.6
FT4 Copper 11.8Ω/km 50 3.20 10.5
10.5Ω/M′ CPE jacket optional. 100 4.60 15.1
34.4Ω/km 200 6.50 21.3
300 8.00 26.2
IEEE 802.4 MAP/IEEE 802.7 Mini-MAP. 400 9.30 30.5

RG-6/U Type • 18 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV* Quad Shield (100% Coverage)
Gas-Injected Foam Polyethylene Insulation • Gray PVC Jacket
3131A NEC: 1000 304.8 41.0 18.6 18 AWG .180 4.57 Duobond IV .300 7.62 75 82% 16.2 53.1 1 .35 1.1
CL2R CMR 2500 762.0 100.0 45.4 (solid) Quad 2 .38 1.2
CEC: .040″ Shield 5 .45 1.5
CMR FT4 BCCS 3.6Ω/M′ 10 .59 1.9
Sweep tested 5 MHz to 400 MHz. 20 .86 2.8
28.0Ω/M′ 11.8Ω/km 50 1.37 4.5
91.8Ω/km CPE jacket optional. 100 1.97 6.5
200 2.82 9.3
IEEE 802.4 MAP/IEEE 802.7 Mini-MAP. 300 3.48 11.4
Tap marks every 2.6 meters to aid users in installation. 400 4.04 13.3
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C 3132A NEC: 1000 304.8 36.0 16.3 18 AWG .170 4.32 Duobond IV .274 6.96 75 82% 16.3 53.5 1 .36 1.2
CMP (solid) Quad 2 .38 1.2
CEC: .040″ Shield 5 .50 1.6
CMP FT6 BCCS 3.6Ω/M′ 10 .65 2.1
20 .95 3.1
28.0Ω/M′ 11.8Ω/km Sweep tested 5 MHz to 400 MHz. 50 1.50 4.9
91.8Ω/km 100 2.12 7.0
IEEE 802.4 MAP/IEEE 802.7 Mini-MAP. 200 2.99 9.8
Tap marks every 2.6 meters to aid users in installation. 300 3.66 12.0
Suitable for Outdoor and Direct Burial applications. 400 4.23 13.9

RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV* Quad Shield (100% Coverage)
Gas-Injected Foam Polyethylene Insulation • Gray PVC Jacket
3094A NEC: 500 152.4 35.5 16.1 14 AWG .280 7.11 Duobond IV .407 10.34 75 82% 16.2 53.1 1 .16 .5
CL2R CMR 1000 304.8 62.0 28.1 (solid) Quad 2 .18 .6
CEC: 2000 609.6 140.0 63.6 .064″ Shield 5 .26 .9
CMG FT4 BCCS 1.5Ω/M′ 10 38 1.2
Sweep tested 5 MHz to 400 MHz. 20 .55 1.8
11.0Ω/M′ 4.9Ω/km 50 .83 2.7
36.1Ω/km CPE jacket optional. 100 1.17 3.8
200 1.60 5.3
IEEE 802.4 MAP 300 1.99 6.5
Tap marks every 2.6 meters to aid users in installation. 400 2.30 7.5
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C 3095A NEC: 1000 304.8 76.0 34.5 14 AWG .280 7.11 Duobond IV .387 9.83 75 82% 16.5 54.1 1 .17 .6
CMP (solid) Quad 2 .22 .7
CEC: .064″ Shield 5 .28 .9
CMP FT6 BCCS 3.9Ω/M′ 10 .40 1.3
20 .60 2.0
11.0Ω/M′ 12.8Ω/km 50 1.20 3.9
36.1Ω/km Sweep tested 5 MHz to 400 MHz. 100 1.70 5.6
IEEE 802.4 MAP 200 2.50 8.2
Tap marks every 2.6 meters to aid users in installation. 300 3.04 10.0
Suitable for Outdoor and Direct Burial applications. 400 3.50 11.5
BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene
*Duobond IV Quad Shield = Duobond II Foil + 60% aluminum braid + Duofoil® + 40% aluminum braid.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.21

Industrial Data Solutions® — Industrial Data


DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cables

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Core OD Shielding Nominal OD Nom. Nom. Capacitance Attenuation
Part (stranding) Imp. Vel.
Description C(UL) CEC Materials
No. Diameter of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

FOUNDATION Fieldbus/PROFIBUS PA • 18 AWG Stranded (7x26) TC Conductors • Beldfoil® Shield (100% Coverage) • TC Drain Wire
Polyolefin Insulation • Orange or Blue PVC Jacket (Color Code: Blue, Orange)
Type A 3076F NEC: 250 76.2 10.5 4.8 (2) 18 AWG .088 2.24 100% .253 6.43 100 @ 66% 24.0 78.7 .039 .08 .26
300V 105°C PLTC CM 500 152.4 18.5 8.4 (7x26) Beldfoil 31.25 KHz
(31.25 KBits/sec) ITC 1000 304.8 37.0 16.8 .048″ Shield
CEC: 2500 762.0 85.0 38.6 Tinned 7.5Ω/M′ 123076F — Version with Aluminum Interlocked Armor
CM 5000† 1524.0 170.0 77.2 Copper 24.6Ω/km 133076F — Version with Steel Interlocked Armor
7.5Ω/M′ YM47023 — CPE jacketed version
24.6Ω/km YM46698 — Black & White color-coded pairs
Shorting Fold YM47090 — Various colored jackets
YM41725 — LSZH (FRNC) jacketed version
Fieldbus: Orange jacket. Profibus PA: Intrinsically Safe Blue jacket. Blue available as standard in 1000 ft. put-up only.

FOUNDATION Fieldbus • 22 AWG Stranded (7x30) TC Conductors • Beldfoil Shield (100% Coverage) • Tinned Copper Drain Wire
Polyolefin Insulation • Orange PVC Jacket (Color Code: Blue, Orange)
Type B 3077F NEC: 500† 152.4 11.0 5.0 (2) 22 AWG .059 1.50 100% .196 4.97 100 @ 66% 23.5 77.1 .039 .14 .45
300V 105°C PLTC CM 1000† 304.8 23.0 10.4 (7x30) Beldfoil 31.25 KHz
(31.25 KBits/sec) ITC .030″ Shield
CEC: Tinned 11.4Ω/M′
CM Copper 37.4Ω/km 123077F — Version with Aluminum Interlocked Armor
17.1Ω/M′ 133077F — Version with Steel Interlocked Armor
56.0Ω/km CPE and LSZH jacketed versions also available.
Shorting Fold

FHDPE Insulation • Orange PVC Jacket (Color Code: Blue, Orange)


High Speed ▲ 3078F NEC: 250 76.2 10.0 4.5 (2) 22 AWG .121 3.07 100% .351 8.92 150 @ 78% 8.5 27.9 .250 .18 .59
300V 75°C PLTC CM 500 152.4 23.0 10.4 (7x30) Beldfoil 1 MHz .625 .26 .85
(1.0 & 2.5 MBits/sec) CEC: 1000 304.8 44.0 20.0 .030″ Shield 1.250 .34 1.12
CM 2500 762.0 115.0 52.2 Tinned 3.3Ω/M′ 3.125 .55 1.81
Copper 11.1Ω/km
17.1Ω/M′ 123078F — Version with Aluminum Interlocked Armor
56.1Ω/km 133078F — Version with Steel Interlocked Armor
Shorting Fold CPE and LSZH jacketed versions also available.

PROFIBUS DP • 22 AWG Solid Bare Copper Conductors • Beldfoil (100% Coverage) + Tinned Copper Braid Shield (65% Coverage)
FHDPE Insulation • Chrome or Purple PVC Jacket (Color Code: Red, Green)
300V 75°C 3079A NEC: 1000 304.8 56.0 25.4 (2) 22 AWG .099 2.52 Beldfoil .315 8.00 150 78% 8.5 27.9 .2 .27 .9
PLTC CMG 2000 609.6 112.0 50.8 (solid) + 65% 4.0 .67 2.2
CEC: 3600 1097.6 201.6 91.4 .026″ TC Braid 16.0 1.37 4.5
CMG FT4 Bare Shield 123079A — Aluminum Interlocked Armor 100.0 3.75 12.3
133079A — Steel Interlocked Armor 300.0 6.52 21.4
Copper (100%
16.0Ω/M′ Coverage) YR45047 — CPE jacketed version
52.5Ω/km 3.9Ω/M′ YR44731 — LSZH (FRNC) jacketed version
UL AWM 20201 (600V) 12.8Ω/km
Siemens Sinec L2 cable.

PROFIBUS DP • 22 AWG Stranded (7x30) Bare Copper Conductors • Beldfoil (100% Coverage) + TC Braid Shield (65% Coverage)
FR-FPE Insulation • Purple PVC Jacket (Color Code: Red, Green)
300V 75°C 3079E NEC: 1000 304.8 44.0 20.0 (2) 22 AWG .099 2.52 Beldfoil .315 8.00 150 78% 8.5 27.9 .2 .34 1.1
PLTC CMG 1640 500.0 73.8 33.5 Stranded + 65% 4.0 .81 2.7
CEC: 3280 1000.0 144.3 65.5 (7x30) TC Braid 16.0 1.64 5.4
CMG FT4 Bare Shield
Copper (100%
16.0Ω/M′ Coverage)
52.5Ω/km 3.9Ω/M′
12.8Ω/km
18 • Industrial Cables

DCR = DC Resistance • FHDPE = Foamed High-Density Polyethylene • FR-FPE = Flame-Retardant Polyethylene • FRNC = Flame-Retardant Non-Corrosive • LSZH = Low-Smoke Zero-Halogen • TC = Tinned Copper

Final put-up length may vary -0 to +10% from length shown.


For HSE, see Industrial Ethernet Section for copper and fiber cables.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.22

Industrial Data Solutions® — Industrial Data


DeviceBus® for ODVA DeviceNet™

DeviceNet Communications Rate Table


Maximum Distance
Communications
3082A 3082F 3082K 3083A 3084F 3084A/3085A 7895A 7896A 7897A 7900A
Rate
Ft. m Ft. m Ft. m Ft. m Ft. m Ft. m Ft. m Ft. m Ft. m Ft. m
125 Kbps 1640 500 1640 500 1378 420 1640 500 328 100 328 100 984 300 1378 420 1640 500 328 100
250 Kbps 820 250 820 250 656 200 820 250 328 100 328 100 820 250 656 200 820 250 328 100
500 Kbps 328 100 328 100 246 75 328 100 328 100 328 100 328 100 328 100 328 100 328 100

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Shielding OD Nom. Nom. Capacitance Attenuation
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100
Nom. DCR Ft. 100m

600V Class 1 Thick • 15 and 18 AWG Stranded TC Conductors • Individually Foil Shielded (100% Coverage) + Overall TC Braid (65% Coverage)
PVC/Nylon Insulation (Power) • FEP Insulation (Data) • Gray Sunlight/Oil-resistant PVC Jacket
High Velocity 7897A NEC: 500 152.4 69.5 31.6 (2)15 AWG TC 100% Power Pair: .460 11.7 — — — — — — —
Thick TC-ER 1000 304.8 135.0 61.3 (19x28) Individual Red&Black
600V 75°C 2000 609.6 274.0 124.4 3.6Ω/M′ Foil
11.8Ω/km + Overall
(2)18 AWG TC 65% Data Pair:
(19x30) TC Braid Blue&White 120 75% 12.0 39.4 .125 .13 .43
6.9Ω/M′ 1.8Ω/M′ .500 .25 .82
22.6Ω/km 5.9Ω/km 1.000 .40 1.31
18 AWG stranded (19x30) tinned copper drain wire.
Meter marks on jacket to aid users in installation.
Allen-Bradley P/N 1485 CPI-A

600V Class 1 ODVA Cable V • 16 and 18 AWG Stranded TC Cond. • Individ. Foil Shielded (100% Coverage) + Overall TC Braid (65% Coverage)
PVC/Nylon Insulation (Power) • F-R Polypropylene Insulation (Data) • Gray Sunlight/Oil-resistant PVC Jacket
600V 75°C 7896A NEC: 500 152.4 89.0 40.4 (2)16 AWG TC 100% Power Pair: .525 13.34 — — — — — — —
TC-ER 1000 304.8 168.0 76.2 (19x29) Individual Red&Black
2000 609.6 340.0 154.2 4.9Ω/M′ Foil
16.1Ω/km + Overall
(2)18 AWG TC 65% Data Pair:
(19x30) TC Braid Blue&White 120 64% 14.7 48.2 .125 .13 .43
6.9Ω/M′ 1.8Ω/M′ .500 .25 .82
C(UL) AWM I/II A/B
22.6Ω/km 5.9Ω/km 1.000 .40 1.31
16 AWG stranded (19x29) tinned copper drain wire.
Meter marks on jacket to aid users in installation.
Allen-Bradley P/N 1485 CPI-A

600V Class 1 ODVA Cable IV • 16 and 18 AWG Stranded Tinned Copper Conductors • Unshielded
PVC/Nylon Insulation (Power) • F-R Polypropylene Insulation (Data) • Gray Sunlight/Oil-resistant PVC Jacket
Drop 7900A NEC: 500 152.4 51.0 23.1 (2)16 AWG TC Unshielded Power Pair: .430 10.92 — — — — — — —
600V 75°C TC-ER 1000 304.8 105.0 47.6 (19x29) Red&Black
CEC: 4.9Ω/M′
FT1 16.1Ω/km
(2)18 AWG TC Data Pair:
(19x30) Blue&White 120 64% 14.7 48.2 .125 .13 .43
6.9Ω/M′ .500 .25 .82
C(UL) AWM I/II A/B 22.6Ω/km 1.000 .40 1.31
Meter marks on jacket to aid users in installation.
Allen-Bradley P/N 1485 CPI-C
DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene • F -R = Flame-retardant • TC = Tinned Copper • TC-ER = Tray Cable Exposed Run per 2005 NEC Article 336

ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.23

Industrial Data Solutions® — Industrial Data


DeviceBus® for ODVA DeviceNet™

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Shielding OD Nom. Nom. Capacitance Attenuation
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100
Nom. DCR Ft. 100m

300V Class 2 Thick • 15 and 18 AWG Stranded TC Cond. • Individually Foil Shielded (100% Coverage) + Overall TC Braid (65% Coverage)
PVC Insulation (Power) • FPE Insulation (Data) • Sunlight- and Oil-resistant PVC Jacket (Available in Gray or Red)
Thick 3082A NEC: 500 † 152.4 71.0 32.2 (2)15 AWG TC 100% Power Pair: .480 12.19 — — — — — — —
75°C CMG, 1000 304.8 138.0 62.6 (19x28) Individual Red&Black
PLTC-ER 2000 † 609.6 280.0 127.0 3.6Ω/M′ Foil
CEC: 11.8Ω/km + Overall
CMG FT4 (2)18 AWG TC 65% Data Pair:
(19x30) TC Braid Blue&White 120 75% 12.0 39.4 .125 .13 .43
6.9Ω/M′ 1.8Ω/M′ .500 .25 .82
† 22.6Ω/km 5.9Ω/km 1.000 .36 1.18
500 ft. and 2000 ft. put-ups not available in Red.
UL AWM 20201 (600V) • C(UL) AWM I/II A
18 AWG stranded (19x30) tinned copper drain wire.
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-A

High-Flex 3082F NEC: 500 † 152.4 72.5 32.9 (2)15 AWG TC 100% Power Pair: .480 12.19 — — — — — — —
Thick CMG, 1000 304.8 140.0 63.5 (65x33) Individual Red&Black
75°C PLTC-ER 2000 † 609.6 284.0 128.8 3.6Ω/M′ Foil
CEC: 11.8Ω/km + Overall
CMG FT4 (2)18 AWG TC 65% Data Pair:
(65x36) TC Braid Blue&White 120 75% 12.0 39.4 .125 .13 .43
6.9Ω/M′ 1.8Ω/M′ .500 .25 .82
† 22.6Ω/km 5.9Ω/km 1.000 .36 1.18
500 ft. and 2000 ft. put-ups not available in Red.
UL AWM 20201 (600V) • C(UL) AWM I/II A
18 AWG stranded (65x36) tinned copper drain wire.
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-A

PVC Insulation (Power) • FPE Insulation (Data) • Yellow CPE Jacket


Thick 3083A NEC: 1000 304.8 137.0 62.1 (2)15 AWG TC 100% Power Pair: .475 12.07 — — — — — — —
75°C CMG, PLTC 2000 609.6 278.0 126.1 (19x28) Individual Red&Black
CEC: 3.6Ω/M′ Foil
CMG FT4 11.8Ω/km + Overall
(2)18 AWG TC 65% Data Pair:
(19x30) TC Braid Blue&White 120 75% 12.0 39.4 .125 .13 .43
6.9Ω/M′ 1.8Ω/M′ .500 .25 .82
18 AWG stranded (19x30) tinned copper drain wire. 22.6Ω/km 5.9Ω/km 1.000 .36 1.18
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-A

300V Class 2 Thin • 22 and 24 AWG Stranded TC Conductors • Individ. Foil Shielded (100% Coverage) + Overall TC Braid (65% Coverage)
PVC Insulation (Power) • FPE Insulation (Data) • Gray Sunlight- and Oil-resistant PVC Jacket
Thin 3084A NEC: 500 152.4 22.0 10.0 (2)22 AWG TC 100% Power Pair: .280 7.11 — — — — — — —
75°C CL2 CMG 1000 † 304.8 47.0 21.3 (19x34) Individual Red&Black
CEC: 2000 609.6 96.0 43.6 17.5Ω/M′ Foil
CMG FT4 57.4Ω/km + Overall
(2)24 AWG TC 65% Data Pair:
(19x36) TC Braid Blue&White 120 75% 12.0 39.4 .125* .29* .95*

1000 ft. put-up also available in Red. 28.0Ω/M′ 3.2Ω/M′ .500* .50* 1.64*
22 AWG stranded (19x34) tinned copper drain wire. • C(UL) AWM I/II A 91.9Ω/km 10.5Ω/km 1.000* .70* 2.30*
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-C
High-Flex 3084F NEC: 500 152.4 22.0 10.0 (2)22 AWG TC 100% Power Pair: .275 6.99 — — — — — — —
Thin CL2 CMG 1000 304.8 47.0 21.3 (154x44) Individual Red&Black
75°C CEC: 2000 609.6 96.0 43.6 17.5Ω/M′ Foil
CMG FT4 57.4Ω/km + Overall
(2)24 AWG TC 65% Data Pair:
(105x44) TC Braid Blue&White 120 75% 12.0 39.4 .125* .29* .95*
C(UL) AWM I/II A 28.0Ω/M′ 3.2Ω/M′ .500* .50* 1.64*
22 AWG stranded (26x36) tinned copper drain wire. 91.9Ω/km 10.5Ω/km 1.000* .70* 2.30*
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-C

PVC Insulation (Power) • FPE Insulation (Data) • Yellow CPE Jacket


Thin 3085A NEC: 500 152.4 25.0 11.4 (2)22 AWG TC 100% Power Pair: .280 7.11 — — — — — — —
75°C CL2 CMG 1000 304.8 47.0 21.4 (19x34) Individual Red&Black
CEC: 2000 609.6 96.0 43.6 17.5Ω/M′ Foil
18 • Industrial Cables

CMG FT4 57.4Ω/km + Overall


(2)24 AWG TC 65% Data Pair:
(19x36) TC Braid Blue&White 120 75% 12.0 39.4 .125* .29* .95*
28.0Ω/M′ 3.2Ω/M′ .500* .50* 1.64*
22 AWG stranded (19x34) tinned copper drain wire. 91.9Ω/km 10.5Ω/km 1.000* .70* 2.30*
Meter marks on jacket to aid users in installation. • Allen-Bradley P/N 1485 CPI-C
DCR = DC Resistance • FPE = Foam Polyethylene • PLTC-ER = Power Limited Tray Cable - Exposed Run per 2005 NEC Article 725 • TC = Tinned Copper
*These values are Maximum Attenuation.

ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.24

Industrial Data Solutions® — Industrial Data


DeviceBus® for ODVA DeviceNet™

Standard Conductor Nominal Nominal Maximum


UL NEC/ Standard Lengths Unit Weight Shielding OD Nom. Nom. Capacitance Attenuation
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100
Nom. DCR Ft. 100m

300V Class 2 ODVA Cable III • 20 and 18 AWG Stranded TC Cond. • Indiv. Foil Shielded (100% Coverage) + Overall TC Braid (65% Coverage)
PVC Insulation (Power) • FPE Insulation (Data) • Gray Sunlight/Oil-resistant PVC Jacket
Mid 7895A NEC: 500 152.4 41.0 18.6 (2)18 AWG TC 100% Power Pair: .378 9.60 — — — — — — —
75°C CMG PLTC 1000 304.8 84.0 38.1 (19x30) Individual Red&Black
CEC: 6.9Ω/M′ Foil
CMG FT4 22.6Ω/km + Overall
(2)20 AWG TC 65% Data Pair:
(19x32) TC Braid Blue&White 120 75% 12.0 39.4 .125 .29 .95
UL AWM 20201 (600V) 10.9Ω/M′ 3.2Ω/M′ .500 .50 1.64
20 AWG stranded (19x32) tinned copper drain wire. 35.8Ω/km 10.5Ω/km 1.000 .70 2.30
Meter marks on jacket to aid users in installation.

Flat • 16 AWG Stranded (19x29) Tinned Copper Conductors • Unshielded


PVC Insulation (Power) • FPE Insulation (Data) • Gray Sunlight-resistant PVC Jacket
Class 2 3082K NEC: 246 75.0 30.8 14.0 (4)16 AWG Unshielded Power Pair: .760 10.92 — — — — — — —
300V 75°C CMG CL2 656 200.0 78.7 35.7 TC Red&Black x x
PLTC 1378 420.0 165.4 75.1 (19x29) .210 5.33
CEC: 4.9Ω/M′
CMG FT4 16.1Ω/km Data Pair:
Blue&White 120 75% 14.7 48.2 .125 .13 .43
.500 .25 .82
1.000 .40 1.31
Allen-Bradley P/N 1485 CPI-G

PVC Insulation • Black Sunlight-resistant PVC Jacket


Class 1 3082KP NEC: 246 75.0 32.0 14.5 (4)16 AWG Unshielded Red&Black, .760 10.92 — — — — — — —
Power CMG, ITC, 656 200.0 81.3 36.9 TC Blue&White x x
600V 75°C PLTC, TC 1378 420.0 170.9 77.6 (19x29) .210 5.33
CEC: 4.9Ω/M′
CMG FT4 16.1Ω/km
.125 .13 .43
.500 .25 .82
1.000 .40 1.31
Allen-Bradley P/N 1485 CPI-G
DCR = DC Resistance • FPE = Foam Polyethylene • F-R = Flame-retardant • TC = Tinned Copper if conductor, or Tray Cable if NEC rating.

ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.25

Industrial Data Solutions® — Industrial Data


DeviceBus® for Honeywell Smart Distributed System

Standard Conductor Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Shielding OD Nom. Nom. Capacitance Attenuation
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of dB/ dB/
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100
Nom. DCR Ft. 100m

22 AWG Stranded Tinned Copper Conductors • Each Pair Individually Beldfoil® Shielded (100% Coverage) • Drain Wire
PVC Insulation (Power) • FPE Insulation (Data) • Gray PVC Jacket
UL AWM 3087A NEC: 500 152.4 19.0 8.6 (4)22 AWG 100% Power Pair: .290 7.37 — — — — — — —
Style 2464 CL2 1000 304.8 41.0 18.6 (19x34) Beldfoil Blue&Brown
30V 80°C CEC: 2000 609.6 84.0 38.1 .030″ Each Pair
CSA AWM Ι/ΙΙ A FT1 Tinned
Copper Data Pair:
17.5Ω/M′ Black&White 120 76% 12.0 39.4 .125 .23 .76
57.4Ω/km .500 .42 1.38
1.000 .60 1.97
Micro Cable (Drop)
22 AWG stranded (19x34) tinned copper drain wire.

16 and 20 AWG Stranded Tinned Copper Conductors • Each Pair Individually Beldfoil Shielded (100% Coverage) • Drain Wire
PVC Insulation (Power) • FPE Insulation (Data) • Gray PVC Jacket
UL AWM 3086A NEC: 500 152.4 43.5 19.7 (2)16 AWG TC 100% Power Pair: .398 10.11 — — — — — — —
Style 2464 CL2 1000 304.8 88.0 39.9 (19x29) Beldfoil Blue&Brown
30V 80°C CEC: .067″ Each Pair
CSA AWM Ι/ΙΙ A FT1 3.6Ω/M′
11.8Ω/km
(2)20 AWG TC Data Pair:
(19x32) Black&White 120 76% 12.0 39.4 .125 .18 .59
.041″ .500 .35 1.15
10.0Ω/M′ 1.000 .47 1.54
Mini Cable (Trunk) 32.8Ω/km
20 AWG stranded (19x32) tinned copper drain wire.
DCR = DC Resistance • FPE = Foamed Polyethylene • TC = Tinned Copper

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.26

Industrial Data Solutions® — Industrial Data


DeviceBus® for Square D/Seriplex®

Standard Conductor Nom. Nominal


UL NEC/ Standard Lengths Unit Weight Shielding Nominal OD Nom. Capacitance*
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m
Nom. DCR

18 and 22 AWG Stranded Tinned Copper Conductors • Overall 100% Beldfoil® Shield (100% Coverage) • 22 AWG (7x30) TC Drain Wire
Foam HDPE Insulation (Power) • Foam HDPE Insulation (Data) • Orange PVC Jacket
UL AWM Style 20201 3124A NEC: 1000 304.8 47.0 21.3 (2)18 AWG 100% Power Cdrs: .308 7.82 — — 20.0 65.6
(600V 75°C) CL2 CM (16x30) Overall Red&Black
CEC: .040″ TC Beldfoil
CM 6.8Ω/M′ Shield
21.3Ω/km 10.7Ω/M′
(2)22 AWG 35.1Ω/km Data Cdrs:
(7x30) White&Green — 78% 16.0 52.5
.030″ TC
18.1Ω/M′
Seriplex CBL 1822-P18 59.4Ω/km

16 and 22 AWG Stranded Tinned Copper Conductors • Overall 100% Beldfoil Shield (100% Coverage) • 22 AWG (7x30) TC Drain Wire
Foam HDPE Insulation (Power) • Foam HDPE Insulation (Data) • Orange PVC Jacket
300V 75°C 3125A NEC: 500 152.4 31.5 14.3 (2)16 AWG 100% Power Cdrs: .368 9.35 — — 28.0 91.9
CL2 CM 1000 304.8 63.0 28.6 (26x30) Overall Red&Black
CEC: .060″ TC Beldfoil
CM 4.5Ω/M′ Shield
14.8Ω/km 10.7Ω/M′
(2)22 AWG 35.1Ω/km Data Cdrs:
(7x30) White&Green — 78% 16.0 52.5
.030″ TC
18.1Ω/M′
Seriplex CBL 1622-P1 59.4Ω/km

16, 22 and 12 AWG Stranded Tinned Copper Conductors • Overall Beldfoil Shield (100% Coverage) • 22 AWG (7x30) TC Drain Wire
Foam HDPE Insulation (Control) • Foam HDPE Insulation (Data) • PVC Insulation (Power) • Orange PVC Jacket
300V 75°C 3126A NEC: 1000 304.8 112.0 50.8 (2)16 AWG 100% Control Cdrs: .486 12.34 — — 28.0 91.9
CL2 CM (26x30) Overall Red&Black x x
CEC: .060″ TC Beldfoil .363 9.22
CM 4.5Ω/M′ Shield
14.7Ω/km 10.7Ω/M′
(2)22 AWG 35.1Ω/km Data Cdrs:
(7x30) White&Green — 78% 16.0 52.5
.030″ TC
18.1Ω/M′
59.4Ω/km
(2)12 AWG Power Cdrs: — — — —
(65x30) Black&White,
.090″ TC Red&White
1.8Ω/M′
Seriplex CBL 162212-P16 5.9Ω/km
DCR = DC Resistance • HDPE = High-density Polyethylene • TC = Tinned Copper
*Capacitance between one conductor and other conductors connected to shield.

Square D/Seriplex is a Square D/Schneider AEG trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.27

Industrial Data Solutions® — Industrial Data


DeviceBus® for Phoenix Contact InterBus®-S

Standard Conductor Nom. Nominal


UL NEC/ Standard Lengths Unit Weight Shielding Nominal OD Nom. Capacitance*
Part (stranding) Color Imp. Vel.
Description C(UL) CEC Materials
No. Diameter Code of
Type Ft. m Lbs. kg Nom. DCR Inch mm (Ω) Prop. pF/Ft. pF/m
Nom. DCR

18 and 24 AWG Stranded Tinned Copper Conductors • Overall Beldfoil® Shield (100% Coverage) + Tinned Copper Braid (90% Coverage)
PVC Insulation (Power) • PE Insulation (Data) • Green Polyurethane Jacket
UL AWM Style 20233 3119A — 500 152.4 35.5 16.1 (3)18 AWG 100% Power: .333 8.46 — — — —
(300V 80°C) 1000 304.8 71.0 32.2 (7x26) Overall Red, Blue,
.060″ TC Beldfoil Green w/
6.6Ω/M′ + 90% Yellow Stripe
21.7Ω/km TC Braid
(3pr)24 AWG 2.7Ω/M′ Data:
(7x32) 8.9Ω/km Pink&Gray, 100 66% 15.4 50.5
.024″ TC White&Brown,
23.4Ω/M′ Yellow&Green
76.8Ω/km

24 AWG Stranded Tinned Copper Conductors • Overall 100% Beldfoil Shield (100% Coverage) + Tinned Copper Braid (90% Coverage)
Polyethylene Insulation • Green Polyurethane Jacket
UL AWM Style 20233 3120A — 500 152.4 26.0 11.8 (3pr)24 AWG 100% Pink&Gray, .277 7.04 100 66% 15.4 50.5
(300V 80°C) 1000 304.8 49.0 22.2 (7x32) Overall White&Brown,
TC Beldfoil Yellow&Green
26.0Ω/M′ + 90%
85.3Ω/km TC Braid
2.7Ω/M′
8.9Ω/km

DCR = DC Resistance • PE = Polyethylene • PVC = Polyvinyl Chloride • TC = Tinned Copper


*Capacitance between one conductor and other conductors connected to shield.

18 • Industrial Cables

InterBus-S is a Phoenix Contact trademark.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.28

Industrial Data Solutions® — Industrial Data


EIA Industrial RS-485 PLTC/CM

Standard Standard Nominal Nom. Capacitance


UL NEC/ No. Lengths Unit Weight Nom. DCR OD Nom. Nom.
Part Color Imp. Vel. *
Description C(UL) CEC of * ** **
No. Code of
Type Pairs Ft. m Lbs. kg Cond. Shield Inch mm (Ω) Prop. pF/ pF/ pF/ pF/
Ft. m Ft. m

22 AWG Stranded (7x30) TC Conductors • Twisted Pairs • Overall Beldfoil® Shield (100% Coverage) + TC Braid (90% Coverage) • Drain Wire▲
Datalene® Insulation • Black UV Resistant PVC Jacket (CPE jacket optional)
Oil Res II 3105A▼ NEC: 1 See 500 152.4 23.0 10.4 14.7Ω/M′ 2.8Ω/M′ .284 7.21 120 78% 11.0 36.1 20.9 68.6
300V CM PLTC Chart 1000 304.8 50.0 22.7 48.2Ω/km 9.2Ω/km
† For CPE jacketed version
CEC: (below) 5000 1523.9 255.0 115.8
order Part No. YR44345
CM FT1
3106A NEC: 1.5 ◆ White/Orange, 500 152.4 27.0 12.3 14.7Ω/M′ 2.8Ω/M′ .300 7.62 120 78% 11.0 36.1 20.9 68.6
CM PLTC Orange/White, 1000 304.8 51.0 23.2 48.2Ω/km 9.2Ω/km
For CPE jacketed version
CEC: Blue/White 5000 † 1523.9 260.0 118.1
order Part No. YR46721
CM FT1
3107A▼ NEC: 2 See 1000 304.8 69.0 31.3 14.7Ω/M′ 1.8Ω/M′ .356 9.04 120 78% 11.0 36.1 20.9 68.6
CM PLTC Chart 4000 1219.2 300.0 136.2 48.2Ω/km 5.9Ω/km
For CPE jacketed version
CEC: (below) 5000 † 1523.9 385.0 174.8
order Part No. YR46792
CM FT1
3108A NEC: 3 See 1000 304.8 93.0 42.2 14.7Ω/M′ 1.5Ω/M′ .420 10.67 120 78% 11.0 36.1 20.9 68.6
CM PLTC Chart 2000 609.6 184.0 83.5 48.2Ω/km 4.9Ω/km
For CPE jacketed version
CEC: (below)
order Part No. YR45287
CM FT1
3109A NEC: 4 See 1000 304.8 107.0 48.6 14.7Ω/M′ 1.4Ω/M′ .420 10.67 120 78% 11.0 36.1 20.9 68.6
CM PLTC Chart 2000 609.6 218.0 99.0 48.2Ω/km 4.6Ω/km
CEC: (below) For CPE jacketed version

3015A and 3107A are DMX512 Type. CM FT1 order Part No. YR44768

22 AWG stranded tinned copper drain wire.
AL Interlocked Armor • Datalene® Insulation • PVC Inner Jacket • Black UV Resistant PVC Outer Jacket
300V 123107A NEC: 2 See 5000 †† 1523.9 1140.0 514.1 14.7Ω/M′ 1.8Ω/M′ .650 16.51 120 78% 11.0 36.1 20.9 68.6
u CM PLTC Chart 48.2Ω/km 5.9Ω/km
CEC: (below)
CMG FT4


22 AWG stranded tinned copper drain wire.
DCR = DC Resistance • TC = Tinned Copper
* Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
† Final put-up length may vary -0 to +10% from length shown.
†† Final put-up length may vary ±10% for spools or reels and ±5% for UnReel® cartons from length shown.


All conductors are under the braid shield; one pair is under the Beldfoil shield.

Color Code Chart


Pair No. Color Combination
1 White/Blue Stripe
Blue/White Stripe
2 White/Orange Stripe
Orange/White Stripe
3 White/Green Stripe
Green/White Stripe
4 White/Brown Stripe
Brown/White Stripe

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.29

Industrial Data Solutions® — Interconnect Cable


Shielded Twisted Pair Cables

Standard Standard Nominal Nom. Capacitance


UL NEC/ No. Lengths Unit Weight Nom. DCR OD Nom. Nom.
Part Color Imp. Vel. *
Description C(UL) CEC of * ** **
No. Code of
Type Pairs Ft. m Lbs. kg Cond. Shield Inch mm (Ω) Prop. pF/ pF/ pF/ pF/
Ft. m Ft. m

24 AWG Stranded (7x32) TC Conductors • Twisted Pairs • Individually Beldfoil® Shielded (100% Coverage) • 24 AWG Stranded TC Drain Wire
Datalene® Insulation • Chrome PVC Jacket
UL AWM Style 2493 9729 NEC: 2 Red&Black, 100 30.5 4.3 2.0 24.0Ω/M′ 15.0Ω/M′ .266 6.76 100 76% 12.5 41.0 23.2 76.1
(300V 60°C) CM White&Black 500 152.4 20.5 9.3 78.7Ω/km 49.3Ω/km
CEC: 1000 304.8 39.0 17.7
CM 10000 3048.0 390.0 177.1
For Plenum version of 9729,
see 89729 or 82729.
Z-Fold®
24 AWG stranded (7x32) tinned copper drain wire.

22 AWG Stranded (7x30) TC Conductors • Twisted Pairs • Individually Beldfoil Shielded (100% Coverage) • 22 AWG Stranded TC Drain Wire
Polypropylene Insulation • Chrome PVC Jacket
UL AWM Style 2919 8777 NEC: 3 Red&Black, 100 30.5 4.6 2.1 15.0Ω/M′ 10.6Ω/M′ .273 6.93 50 66% 30 98 55 180
(30V 80°C) CM White&Black, 250 76.2 11.0 5.0 49.2Ω/km 34.8Ω/km
CEC: Green&Black U-500 U-152.4 21.0 9.5
CM 500 152.4 21.0 9.5
U-1000 U-304.8 41.0 18.6
1000 304.8 42.0 19.1
For Plenum versions of 8777,
1640 499.9 67.2 30.5
see 88777, 87777 or 82777.
3280 999.7 137.8 62.5
5000 1524.0 210.0 95.3
Z-Fold® 10000 3048.0 450.0 204.3

22 AWG stranded (19x34) tinned copper drain wire.

22 AWG Stranded (7x30) TC Conductors • Twisted Pairs • Individually Beldfoil Shielded (100% Coverage) • 24 AWG Stranded TC Drain Wire
Polypropylene Insulation • Chrome PVC Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS 60°C 8723 NEC: 2 Red&Black, 100 30.5 2.3 1.0 16.0Ω/M′ 14.7Ω/M′ .168 4.27 45 66% 35 115 62 203
CM Green&White U-500 U-152.4 10.5 4.8 52.5Ω/km 48.3Ω/km
CEC: 500 152.4 10.0 4.5
CM U-1000 U-304.8 20.0 9.1
1000 304.8 20.0 9.1
Z-Fold® 1640 499.9 32.8 14.9 For Plenum versions of 8723,
U-2000 U-609.6 40.0 18.2 see 88723, 87723 or 82723.
2000 609.6 40.0 18.2
3280 999.7 65.6 29.8
5000 1524.0 95.0 43.1
10000 3048.0 200.0 90.8
24 AWG stranded (7x32) tinned copper drain wire.
Plenum • FEP Insulation • Red FEP Jacket (Pairs Cabled on Common Axis to Reduce Diameter)
300V RMS, Non-conduit 88723 NEC: 2 Red&Black, 100 30.5 3.4 1.5 16.0Ω/M′ 14.7Ω/M′ .148 3.76 40 69% 35 115 67 220
CMP Green&White 500 152.4 11.0 5.0 52.5Ω/km 48.3Ω/km
CEC: 1000 304.8 21.0 9.5
CMP FT6

Z-Fold®

24 AWG stranded (7x32) tinned copper drain wire.

18 AWG Stranded (16x30) TC Conductors • Twisted Pair • Overall Beldfoil Shield (100% Coverage) • 20 AWG Stranded TC Drain Wire
Polyethylene Insulation • Chrome PVC Jacket
UL AWM Style 2092 8760 NEC: 1 Black 250 76.2 6.8 3.1 — — .222 5.64 — — 24 79 44 144
(300V 60°C) CM &Clear U-500 U-152.4 13.0 5.9
CEC: 500 152.4 13.0 5.9
CM U-1000 U-304.8 26.0 11.8
1000 304.8 26.0 11.8 For Plenum versions of 8760,
2000 609.6 50.0 22.7 see 88760, 87760 or 82760.
18 • Industrial Cables

Shorting Fold 5000 1524.0 135.0 61.3


10000 3048.0 260.0 118.0
20 AWG stranded (7x28) tinned copper drain wire.
DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • PVC = Polyvinyl Chloride • TC = Tinned Copper
* Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.30

VFD (Variable Frequency Drive) Cable


1000V UL Flexible Motor Supply Cable

Standard Nominal Maximum Minimum


Standard Lengths
Part Cond. Unit Wt. OD Pull Tension Bend Radius
Description AWG
No. Stranding
Ft. m Lbs. kg Inch mm Lbs. N Inch mm

4-cond. (3) Stranded TC Circuit Conductors + (1) Ground* • Overall Beldfoil® (100% Coverage) + TC Braid Shield (85% Coverage) • TC Drain Wire*
XLPE Insulation (Circuit Condrs) • PVC Insulation (Ground) • Black Sunlight- and Oil-resistant PVC Jacket
1000V UL 29500 16 26x30 250† 76.2 46.2 21.0 .53 13.46 128 568 3.9 99.06
Flexible Motor Supply Cable 500† 152.4 93.0 42.2
600V UL 1277 Type TC-ER All Allen-Bradley Series 1000† 304.8 182.0 82.6
per 2005 NEC Article 336 160 and 1305 drives. 6000† 1828.8 1080.0 490.3
1000V CSA AWM Ι/ΙΙ A/B FT4 29501 14 41x30 250† 76.2 59.7 27.1 .55 13.97 212 942 4.5 114.30
90°C Wet/Dry 500† 152.4 120.0 54.5
Allen-Bradley 1336F(S)-BRF05 1000† 304.8 233.0 105.8
through BRF100 5000† 1524.0 1215.0 551.6
29502 12 65x30 250† 76.2 69.8 31.7 .60 15.24 336 1495 4.9 124.46
500† 152.4 151.5 68.8
1000† 304.8 298.0 135.3
Allen-Bradley 1336F(S)-BRF150, BRF200 5000† 1524.0 1570.0 712.8
29503 10 105x30 250† 76.2 91.3 41.4 .66 16.76 525 2335 5.4 137.16
500† 152.4 194.5 88.3
1000† 304.8 375.0 170.3
Allen-Bradley 1336F(S)-B015 5000† 1524.0 2025.0 919.4
29504 8 7x19x29 250† 76.2 158.5 72.0 .89 22.61 1328 5906 7.3 185.42
500† 152.4 332.0 150.7
1000† 304.8 660.0 299.6
Allen-Bradley 1336F(S)-B020 5000† 1524.0 3135.0 1423.3
29505 6 7x19x27 250† 76.2 221.3 100.5 .99 25.15 2048 9109 8.0 203.20
1000† 304.8 906.0 411.3
Allen-Bradley 1336F(S)-B025, B030 3500† 1066.8 3206.0 1455.5
29506 4 7x19x25 250† 76.2 319.5 145.1 1.15 29.21 3152 14021 9.2 233.68
1000† 304.8 1231.0 558.9
Color Code: ICEA Method 4 Allen-Bradley 1336F(S)-BX040, B040 3000† 914.4 3843.0 1744.7
(Black and Numbered); 29507 2 7x19x23 250† 76.2 437.8 198.7 1.29 32.77 4872 21672 10.5 266.70
Green/Yellow Ground 500† 152.4 875.5 397.5
UL Direct Burial. Allen-Bradley 1336F(S)-B050, 1000† 304.8 1711.0 776.8
XHHW-2, RHW-2 rated circuit conductors. BX060, B060 2000† 609.6 3682.0 1671.6

Three (3) Stranded TC Circuit Conductors + (3) Symmetrical Bare Copper Grounds • (2) Spiral Copper Tape Shields (100% Coverage)
XLPE Insulation (Circuit Condrs) • Black Sunlight- and Oil-resistant PVC Jacket
1000V UL 29528 1 7x19x22 250 †† 76.2 398.8 181.0 1.20 30.48 2650 11788 12.0 304.8
Flexible Motor Supply Cable u 1000 †† 304.8 1642.0 746.0
600V UL 1277 Type TC-ER 3000 † 1524.0 4779.0 2169.7
per 2005 NEC Article 336 29529 1/0 7x19x21 250 †† 76.2 525.8 238.7 1.29 32.77 3537 15733 12.9 327.7
600V CSA AWM Ι/ΙΙ A/B FT4 u 1000 †† 304.8 2050.0 930.7
90°C Wet/Dry 2000 † 609.6 3954.0 1795.1
29530 2/0 7x19x20 250 †† 76.2 602.0 273.3 1.40 35.56 4200 18682 14.0 355.6
u 1000 †† 304.8 2362.0 1072.4
2000 † 609.6 4744.0 2153.8
29531 3/0 7x19x19 250 †† 76.2 699.5 317.6 1.52 38.61 5025 22352 15.2 386.1
u 1000 †† 304.8 2708.0 1229.4
Color Code: ICEA Method 4 3000 † 1524.0 5436.0 2467.9
(Black and Numbered)
29532 4/0 7x19x18 250 †† 76.2 881.0 400.0 1.68 42.67 6670 29670 16.8 426.7
UL Direct Burial. u 500 †† 152.4 1873.0 850.3
XHHW-2 circuit conductors. 1500 † 457.2 5619.0 2551.0
TC = Tinned Copper • TC-ER = Tray Cable - Exposed Run per 2005 NEC Article 336 • XLPE = Cross-linked Polyethylene
*Ground(s) and drain wire(s) are same AWG as circuit conductors. Encoder Cables
†Final put-up length may vary ±10% from length shown. Belden also offers the following standard cables for
††Final put-up length may vary ±5% from length shown.
encoder applications. Encoder cables help feed
information to the microprocessor regarding both
the speed and the position of the rotor.
Part No. Pairs AWG
8790 (Power Supply) 1 18
9729 2 24
9730, 89730 3 24
9728 4 24
9892 4 20
See Index for page numbers.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.31

Belden Infinity Flexible Automation Cable ®

Overview and Application Guide

Belden Infinity is a complete line of control, Belden Infinity Means More Product Series Descriptions
data, video, and power cables specifically Performance And Longer Life
designed to handle the rigorous speeds ● C-TC+ — The C-TC+ series is designed
and near-constant motion encountered in Reduced Cable Memory — Belden for C-track and extreme flex applications
automated equipment such as robots, pick Infinity’s unique design and neutralized up to 9 million flex cycles*. This series
and place machines, automatic handling cabling, results in cables that are relaxed, utilizes super fine stranding and some
systems, multi-axis machine tools, and with almost no memory. of the tightest lay lengths allowed by
conveyor systems. UL, providing outstanding flex life.
Greater Flex Life — Belden Infinity cables
When the application demands highly flexible offer superior flexibility and are able to handle ● FCC — The FCC series is a cost
cables offering exceptional cable life and the vigorous motions and high speeds effective alternative for C-track and
performance, specify Belden Infinity. encountered in automated equipment. moderate flexing applications rated
Greater System Uptime — Belden up to 1 million flex cycles*.
Infinity cables combine specialized ● Flex Data Cables — Belden Infinity
manufacturing techniques with precision Flex Data cables are designed for
copper stranding and rugged insulation industrial applications where precise
and jacketing compounds to maximize data transmission is combined with
flex life and reliability. high-flexing. These cables are ideal
No Talc Problems — Unlike the potentially for effective operation of computer
harmful talc used in other cables, Belden’s controlled equipment or other
non-toxic, non-irritating slipper compound automated production processes,
facilitates flexing and also complies with even in harsh environments.
OSHA regulations. It’s safer for employees ● Flex Vision — Belden Infinity Vision
and operators and is less likely to contami-
cables are continuous flex video
nate solder joints or mechanical compounds.
cables designed for machine vision
CE Conformity — All Belden Infinity applications. They are ideal for motion-
cables are CE marked per the Conformité controlled video and with inspection
Européenne low voltage directive, allowing and measurement equipment.
trade of product in Europe.
Custom Designs — Other designs
available upon request.

Application Guide

Inspection
Multi- Automated Material Pick & Automated Motion- &
C-Track Axis Assembly Handling Place Storage Gantry Machine Controlled Measure
Belden Infinity Series Systems Machining Robotics Systems Systems Systems Retrieval Systems Vision Video Equip. Festooning Servo Power

FCC
Oil & abrasion resistant
600V UL & CSA rated ● ● ● ● ● ● ● ● ● ● ●
Life Expectancy:
Over 1 million flex cycles*
C-TC+
Oil & abrasion resistant
600V UL & CSA rated ★ ★ ● ★ ★ ★ ★ ★ ★ ★ ★ ★
Life Expectancy:
Over 9 million flex cycles*
DATA
Oil & abrasion resistant
300V UL & CSA rated ● ● ● ● ● ● ● ● ● ●
Life Expectancy:
Over 1 million flex cycles*
VISION
18 • Industrial Cables

30V UL & CSA rated


Life Expectancy: ● ● ● ● ● ● ● ★ ✚ ✚ ●
Over 1 million flex cycles*

● Good ✚ Better ★ Best

*Based on proper installation techniques in a C-track cable guide.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.32

Belden Infinity Flexible Automation Cable ®

600V C -TC+ Control Cables for Extreme Flexing


(9 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

20 AWG Stranded (74x38) Bare Copper Conductors • Unshielded • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • Orange Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7101A 3 250 † 76.2 11.0 5.0 .020 .51 .045 1.14 .275 6.99 45 200
CSA AWM Ι/ΙΙ A/B 500 † 152.4 24.5 11.1
1000 † 304.8 47.0 21.3
7102A 4 250 † 76.2 13.3 6.0 .020 .51 .045 1.14 .295 7.49 59 262
500 † 152.4 27.5 12.5
1000 † 304.8 53.0 24.1
7105A 9 250 † 76.2 29.8 13.5 .020 .51 .055 1.40 .435 11.05 130 578
500 † 152.4 52.0 23.6
1000 † 304.8 104.0 47.2
7106A 12 250 † 76.2 32.3 14.6 .020 .51 .055 1.40 .455 11.56 178 792
500 † 152.4 66.5 30.2
1000 † 304.8 134.0 60.8
7107A 18 250 † 76.2 50.0 22.7 .020 .51 .065 1.65 .545 13.84 260 1156
500 † 152.4 101.0 45.9
Temp Rating: -40° to 90°C 7108A 25 250 † 76.2 71.5 32.5 .020 .51 .080 2.03 .665 16.89 370 1645
(-5° to 90°C flexing) 500 † 152.4 143.5 65.2

20 AWG Stranded (74x38) Bare Copper Conductors • TC Braid Shield (85% Coverage) • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Orange Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7106AS 12 250 † 76.2 57.5 26.1 .020 .51 Inner: .535 13.59 194 863
CSA AWM Ι/ΙΙ A/B 500 † 152.4 116.0 52.7 .025 .64
Outer:
.055 1.40

Temp Rating: -40° to 90°C (-5° to 90°C flexing)

18 AWG Stranded (114x38) Bare Copper Conductors • Unshielded • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • Orange Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7110A 3 500 † 152.4 26.0 11.8 .020 .51 .035 .89 .300 7.62 69 307
CSA AWM Ι/ΙΙ A/B 1000 † 304.8 50.0 22.7
7113A 7 250 † 76.2 29.0 13.2 .020 .51 .060 1.52 .438 11.13 155 689
500 † 152.4 55.5 25.2
1000 † 304.8 111.0 50.4
7115A 12 250 † 76.2 40.3 18.3 .020 .51 .060 1.52 .513 13.03 270 1201
500 † 152.4 84.5 38.4
7116A 18 250 † 76.2 63.0 28.6 .020 .51 .060 1.52 .598 15.19 400 1779
500 † 152.4 126.0 57.2
Temp Rating: -40° to 90°C 7117A 25 250 † 76.2 89.3 40.5 .020 .51 .083 2.11 .744 18.90 570 2535
(-5° to 90°C flexing) 500 † 152.4 179.0 81.3

18 AWG Stranded (114x38) Bare Copper Conductors • TC Braid Shield (85% Coverage) • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Orange Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7111AS 4 250 † 76.2 4.0 1.8 .020 .51 Inner: .405 10.29 84 373
CSA AWM I/II A/B 500 † 152.4 60.5 27.5 .025 .64
Outer:
.050 1.27
7115AS 12 250 † 76.2 72.8 33.1 .020 .51 Inner: .600 15.24 252 1121
500 † 152.4 144.5 65.6 .025 .64
Outer:
.065 1.65
PVC = Polyvinyl Chloride • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.33

Belden Infinity Flexible Automation Cable ®

600V C -TC+ Control Cables for Extreme Flexing


(9 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

16 AWG Stranded (190x38) Bare Copper Conductors • Unshielded • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • Orange Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7122A 3 250 † 76.2 16.3 7.4 .020 .51 .045 1.14 .325 8.26 114 507
CSA AWM Ι/ΙΙ A/B 500 † 152.4 43.5 19.8
1000 † 304.8 84.0 38.1
7125A 7 250 † 76.2 38.5 17.5 .020 .51 .060 1.52 .480 12.19 260 1156
500 † 152.4 73.5 33.4
1000 † 304.8 148.0 67.2
7126A 9 250 † 76.2 49.3 22.4 .020 .51 .060 1.52 .545 13.84 340 1512
1000 † 304.8 195.0 88.5
7127A 12 250 † 76.2 53.3 24.2 .020 .51 .060 1.52 .570 14.48 450 2001
500 † 152.4 122.5 55.6
1000 † 304.8 243.0 110.3
7128A 18 250 † 76.2 85.3 38.7 .020 .51 .060 1.52 .670 17.02 680 3025
500 † 152.4 172.0 78.1
Temp Rating: -40° to 90°C 7129A 25 250 † 76.2 124.5 56.5 .020 .51 .080 2.03 .820 20.83 950 4226
(-5° to 90°C flexing) 500 † 152.4 247.5 112.4

16 AWG Stranded (190x38) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Orange Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7123AS 4 250 † 76.2 40.8 18.5 .020 .51 Inner: .420 10.67 154 685
CSA AWM Ι/ΙΙ A/B 500 † 152.4 78.0 35.4 .025 .64
Outer:
.040 1.02

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

14 AWG Stranded (266x38) Bare Copper Conductors • Unshielded • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • Orange Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7136A 4 250 † 76.2 39.0 17.7 .025 .64 .050 1.27 .430 10.92 212 943
CSA AWM Ι/ΙΙ A/B 500 † 152.4 74.5 33.8

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

14 AWG Stranded (266x38) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Orange Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7136AS 4 250 † 76.2 74.0 33.6 .025 .64 Inner: .500 12.70 208 925
CSA AWM Ι/ΙΙ A/B 500 † 152.4 145.0 65.8 .025 .64
Outer:
.045 1.14

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

12 AWG Stranded (413x38) Bare Copper Conductors • Unshielded • Color Code: Red w/numbers + Green/Yellow ground
PVC Insulation • Orange Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7145A 4 250 † 76.2 72.5 32.9 .030 .76 .075 1.91 .545 13.84 274 1218
CSA AWM Ι/ΙΙ A/B 500 † 152.4 146.0 66.3
18 • Industrial Cables

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.34

Belden Infinity Flexible Automation Cable ®

600V FCC Control Cables for Moderate Flexing


(1 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

20 AWG Stranded (10x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7400A 2 250 † 76.2 11.0 5.0 .022 .56 .040 1.02 .240 6.10 26 116
CSA AWM Ι/ΙΙ A/B 500 † 152.4 25.0 11.4
1000 † 304.8 44.0 20.0
7401A 3 250 † 76.2 13.0 5.9 .022 .56 .040 1.02 .250 6.35 39 173
500 † 152.4 30.0 13.6
1000 † 304.8 59.0 26.8
7402A 4 250 † 76.2 15.0 6.8 .022 .56 .040 1.02 .275 6.99 52 231
500 † 152.4 33.0 15.0
1000 † 304.8 64.0 29.1
7403A 5 250 † 76.2 17.5 8.0 .022 .56 .040 1.02 .300 7.62 65 289
500 † 152.4 38.0 17.3
1000 † 304.8 72.0 32.7
7404A 7 250 † 76.2 22.0 10.0 .022 .56 .040 1.02 .345 8.76 91 405
500 † 152.4 44.5 20.2
1000 † 304.8 86.0 39.0
7405A 9 250 † 76.2 29.5 13.4 .022 .56 .053 1.35 .410 10.41 117 520
500 † 152.4 71.5 32.5
1000 † 304.8 144.0 65.4
7406A 12 250 † 76.2 30.8 14.0 .022 .56 .053 1.35 .420 10.67 156 693
500 † 152.4 88.5 40.2
1000 † 304.8 177.0 80.4
7407A 18 250 † 76.2 53.5 24.3 .022 .56 .053 1.35 .500 12.70 234 1041
500 † 152.4 104.0 47.2
Temp Rating: -40° to 90°C 7408A 25 250 † 76.2 65.3 29.6 .022 .56 .065 1.65 .615 15.62 325 1445
(-5° to 90°C flexing) 500 † 152.4 130.5 59.3

20 AWG Stranded (10x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7401AS 3 500 † 152.4 54.0 24.5 .022 .56 Inner: .320 8.13 45 200
CSA AWM Ι/ΙΙ A/B .025 .64
Outer:
.035 .89
7402AS 4 250 † 76.2 32.8 14.9 .022 .56 Inner: .330 8.38 52 231
500 † 152.4 64.0 29.1 .025 .64
Outer:
.035 .89
7403AS 5 250 † 76.2 34.8 15.8 .022 .56 Inner: .370 9.40 65 289
500 † 152.4 68.0 30.9 .025 .64
Outer:
.035 .89
7404AS 7 250 † 76.2 37.8 17.1 .022 .56 Inner: .420 10.67 91 405
500 † 152.4 71.5 32.5 .025 .64
Temp Rating: -40° to 90°C Outer:
(-5° to 90°C flexing) .040 1.02
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.35

Belden Infinity Flexible Automation Cable ®

600V FCC Control Cables for Moderate Flexing


(1 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

18 AWG Stranded (16x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7409A 2 250 † 76.2 13.3 6.0 .022 .56 .040 1.02 .264 6.71 50 222
CSA AWM Ι/ΙΙ A/B 500 † 152.4 26.5 12.0
1000 † 304.8 51.0 23.2
7410A 3 250 † 76.2 16.3 7.4 .022 .56 .040 1.02 .280 7.11 74 329
500 † 152.4 25.0 11.4
1000 † 304.8 48.0 21.8
7411A 4 250 † 76.2 18.8 8.5 .022 .56 .040 1.02 .305 7.75 98 436
500 † 152.4 31.0 14.1
1000 † 304.8 58.0 26.3
7412A 5 250 † 76.2 21.8 9.9 .022 .56 .040 1.02 .330 8.38 122 542
500 † 152.4 36.0 16.3
1000 † 304.8 69.0 31.3
7413A 7 250 † 76.2 27.5 12.5 .022 .56 .040 1.02 .385 9.78 171 760
500 † 152.4 46.0 20.9
1000 † 304.8 120.0 54.5
7414A 9 250 † 76.2 36.5 16.6 .022 .56 .050 1.27 .452 11.48 220 978
500 † 152.4 87.0 39.5
1000 † 304.8 174.0 79.0
7415A 12 250 † 76.2 40.0 18.2 .022 .56 .050 1.27 .475 12.07 292 1298
500 † 152.4 75.5 34.3
1000 † 304.8 161.0 73.1
7416A 18 250 † 76.2 55.8 25.3 .022 .56 .050 1.27 .560 14.22 440 1957
500 † 152.4 112.5 51.1
7417A 25 250 † 76.2 74.3 33.7 .022 .56 .072 1.83 .696 17.68 520 2313
500 † 152.4 149.0 67.6
7418A 34 250 † 76.2 111.3 50.5 .022 .56 .072 1.83 .788 20.02 830 3692
500 † 152.4 215.5 97.8
Temp Rating: -40° to 90°C 7419A 41 500 † 152.4 295.0 133.9 .022 .56 .075 1.91 .860 21.84 1001 4453
(-5° to 90°C flexing) 7420A 50 250 † 76.2 186.5 84.7 .022 .56 .083 2.11 .940 23.88 1220 5427

18 AWG Stranded (16x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7411AS 4 250 † 76.2 29.0 13.2 .022 .56 Inner: .365 9.27 83 369
CSA AWM Ι/ΙΙ A/B 500 † 152.4 56.5 25.7 .025 .64
Outer:
.032 .81
7413AS 7 250 † 76.2 37.5 17.0 .022 .56 Inner: .450 11.43 145 645
500 † 152.4 74.0 33.6 .025 .64
Outer:
.035 .89
7415AS 12 250 † 76.2 61.5 27.9 .022 .56 Inner: .550 13.97 230 1023
500 † 152.4 124.0 56.3 .025 .64
Outer:
.045 1.14
7416AS 18 250 † 76.2 83.3 37.8 .022 .56 Inner: .650 16.51 374 1663
500 † 152.4 169.0 76.7 .025 .64
Outer:
.055 1.40
7417AS 25 250 † 76.2 113.8 51.6 .022 .56 Inner: .765 19.43 520 2313
500 † 152.4 228.0 103.5 .025 .64
Temp Rating: -40° to 90°C Outer:
(-5° to 90°C flexing) .060 1.52
BC = Bare Copper • TC = Tinned Copper
18 • Industrial Cables

*Based on proper installation techniques in a C-track cable guide.



Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.36

Belden Infinity Flexible Automation Cable ®

600V FCC Control Cables for Moderate Flexing


(1 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

16 AWG Stranded (26x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7421A 2 250 † 76.2 15.0 6.8 .022 .56 .040 1.02 .290 7.37 70 311
CSA AWM Ι/ΙΙ A/B 500 † 152.4 35.0 15.9
1000 † 304.8 68.0 30.9
7422A 3 250 † 76.2 18.8 8.5 .022 .56 .040 1.02 .305 7.75 105 467
500 † 152.4 34.5 15.7
1000 † 304.8 65.0 29.5
7423A 4 250 † 76.2 22.5 10.2 .022 .56 .040 1.02 .330 8.38 140 623
500 † 152.4 41.5 18.8
1000 † 304.8 80.0 36.3
7424A 5 250 † 76.2 27.5 12.5 .022 .56 .040 1.02 .360 9.14 175 778
500 † 152.4 49.5 22.5
1000 † 304.8 96.0 43.6
7425A 7 250 † 76.2 35.0 15.9 .022 .56 .040 1.02 .425 10.80 236 1050
500 † 152.4 64.0 29.1
1000 † 304.8 129.0 58.6
7426A 9 250 † 76.2 50.5 22.9 .022 .56 .060 1.52 .540 13.72 304 1352
500 † 152.4 95.0 43.1
1000 † 304.8 190.0 86.3
7427A 12 250 † 76.2 55.3 25.1 .022 .56 .065 1.65 .565 14.35 405 1801
500 † 152.4 114.0 51.8
1000 † 304.8 220.0 100.0
7428A 18 250 † 76.2 79.0 35.9 .022 .56 .065 1.65 .650 16.51 608 2705
500 † 152.4 158.0 71.7
7429A 25 250 † 76.2 109.0 49.5 .022 .56 .060 1.52 .750 19.05 875 3892
500 † 152.4 218.5 99.2
Temp Rating: -40° to 90°C 7430A 34 250 † 76.2 171.3 77.7 .022 .56 .075 1.91 .878 22.30 1145 5093
(-5° to 90°C flexing)

16 AWG Stranded (26x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7423AS 4 250 † 76.2 36.0 16.3 .022 .56 Inner: .400 10.16 140 623
CSA AWM Ι/ΙΙ A/B 500 † 152.4 68.0 30.9 .025 .64
Outer:
.035 .89
7427AS 12 250 † 76.2 81.8 37.1 .022 .56 Inner: .630 16.00 420 1868
500 † 152.4 164.5 74.7 .025 .64
Outer:
.060 1.52
7428AS 18 250 † 76.2 119.0 54.1 .022 .56 Inner: .740 18.80 630 2802
500 † 152.4 238.5 108.3 .025 .64
Temp Rating: -40° to 90°C Outer:
(-5° to 90°C flexing) .070 1.78
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.37

Belden Infinity Flexible Automation Cable ®

600V FCC Control Cables for Moderate Flexing


(1 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

14 AWG Stranded (41x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7434A 2 250 † 76.2 34.0 15.5 .023 .58 .045 1.14 .335 8.51 201 894
CSA AWM Ι/ΙΙ A/B 500 † 152.4 66.5 30.2
1000 † 304.8 92.0 41.8
7435A 3 250 † 76.2 39.8 18.1 .023 .58 .045 1.14 .350 8.89 201 894
500 † 152.4 78.5 35.6
1000 † 304.8 98.0 44.5
7436A 4 250 † 76.2 49.3 22.4 .023 .58 .050 1.27 .395 10.03 201 894
500 † 152.4 95.0 43.1
1000 † 304.8 131.0 59.5
7438A 7 500 † 152.4 150.5 68.3 .023 .58 .060 1.52 .525 13.33 373 1659
7439A 9 250 † 76.2 110.8 50.3 .023 .58 .070 1.78 .620 15.75 480 2135
500 † 152.4 223.0 101.2
7440A 12 250 † 76.2 142.5 64.7 .023 .58 .075 1.91 .660 16.76 640 2847
500 † 152.4 285.5 129.6
Temp Rating: -40° to 90°C 7442A 25 250 † 76.2 223.8 101.7 .023 .58 .090 2.29 .930 23.62 1337 5947
(-5° to 90°C flexing)

14 AWG Stranded (41x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7436AS 4 250 † 76.2 49.3 22.4 .023 .58 Inner: .482 12.24 212 943
CSA AWM Ι/ΙΙ A/B 500 † 152.4 95.0 43.1 .025 .64
Outer:
.055 1.40
7438AS 7 250 † 76.2 74.8 33.9 .023 .58 Inner: .563 14.30 371 1650
500 † 152.4 150.5 68.3 .025 .64
Temp Rating: -40° to 90°C Outer:
(-5° to 90°C flexing) .060 1.52

12 AWG Stranded (65x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7444A 3 250 † 76.2 53.5 24.3 .028 .71 .060 1.52 .450 11.43 253 1125
CSA AWM Ι/ΙΙ A/B 500 † 152.4 103.5 47.0
7445A 4 250 † 76.2 63.5 28.8 .028 .71 .070 1.78 .505 12.83 338 1503
500 † 152.4 124.0 56.3

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

12 AWG Stranded (65x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7445AS 4 250 † 76.2 85.8 38.9 .028 .71 Inner: .580 14.73 338 1503
CSA AWM Ι/ΙΙ A/B 500 † 152.4 171.5 77.9 .030 .76
Outer:
.070 1.78

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.
18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.38

Belden Infinity Flexible Automation Cable ®

600V FCC Control Cables for Moderate Flexing


(1 Million Flex Cycles*)

Standard Insulation Jacket Nominal Maximum


No. Standard Lengths
Part Unit Weight Thickness Thickness OD Pull Tension
Description of
No.
Cond. Ft. m Lbs. kg Inch mm Inch mm Inch mm Lbs. N

10 AWG Stranded (105x30) Bare Copper Conductors • Unshielded (Color Code: Black w/numbers + Green/Yellow ground)
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7447A 4 250 † 76.2 70.8 32.1 .030 .76 .070 1.78 .570 14.48 672 2989
CSA AWM Ι/ΙΙ A/B 500 † 152.4 142.5 64.7

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

10 AWG Stranded (105x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7447AS 4 250 † 76.2 92.8 42.2 .030 .76 Inner: .660 16.76 546 2429
CSA AWM Ι/ΙΙ A/B 500 † 152.4 185.5 84.3 .035 .89
Outer:
.065 1.65

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

8 AWG Stranded (168x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7450A 4 250 † 76.2 113.8 51.6 .045 1.14 .070 1.78 .715 18.16 920 4092
CSA AWM Ι/ΙΙ A/B 500 † 152.4 228.0 103.5

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

8 AWG Stranded (168x30) BC Conductors • TC Braid Shield (85% Coverage) • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • PVC Inner Jacket • Gray Oil- and Abrasion-resistant PVC Outer Jacket
UL AWM Style 2587 (600V 90°C) 7450AS 4 250 † 76.2 141.3 64.1 .045 1.14 Inner: .815 20.70 872 3879
CSA AWM Ι/ΙΙ A/B 500 † 152.4 281.0 127.6 .040 1.02
Outer:
.065 1.65

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)

6 AWG Stranded (266x30) Bare Copper Conductors • Unshielded • Color Code: Black w/numbers + Green/Yellow ground
PVC Insulation • Gray Oil- and Abrasion-resistant PVC Jacket
UL AWM Style 2587 (600V 90°C) 7453A 4 250 † 76.2 185.0 84.0 .060 1.52 .085 2.16 .925 23.50 1472 6548
CSA AWM Ι/ΙΙ A/B

Temp Rating: -40° to 90°C


(-5° to 90°C flexing)
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.39

Belden Infinity Flexible Automation Cable ®

300V Flex Data Cables


(1 Million Flex Cycles*)

Standard Standard Nominal Maximum


No. UL NEC/ Lengths Unit Weight OD Capacitance Nom.
Part RS Color Imped.
Description of C(UL) CEC
No. Type Code
Pairs Type Ft. m Lbs. kg Inch mm pF/Ft. pF/m (Ω)

Flex Data • 24 AWG Stranded (41x40) BC Condrs. • Twisted Pairs • Overall Beldfoil® (100% Coverage) + TC Braid Shield (85% Coverage)**
Foam Polyethylene Insulation with Skin • Green Oil-resistant PVC Jacket
300V 60°C 7200A 1 NEC: 232 White, 500 152.4 17.0 7.7 .240 6.10 15.0 49.2 120
CM 485 Blue 1000 304.8 38.0 17.3
CEC:
CM
7201A 2 NEC: 232 See 500 152.4 31.0 14.1 .322 8.18 15.0 49.2 120
CM 485 Color Code 1000 304.8 60.0 27.2
CEC: Chart
CM (below)
7202A 3 NEC: 232 See 500 152.4 33.5 15.2 .347 8.81 15.0 49.2 120
CM 485 Color Code 1000 304.8 68.0 30.9
CEC: Chart
CM (below)
7203A 4 NEC: 232 See 500 152.4 39.0 17.7 .362 9.20 15.0 49.2 120
CM 485 Color Code 1000 304.8 79.0 35.9
CEC: Chart
CM (below)
7205A 1 NEC: 232 White, 500 152.4 17.5 7.9 .232 5.89 14.0 45.9 100
CM 422 Blue 1000 304.8 38.0 17.3
CEC:
CM
7206A 1 NEC: 232 White, 1000 304.8 59.0 26.8 .302 7.67 10.0 32.8 150
CM 485 Blue
Temp Rating: -20° to 60°C CEC:
(-5° to 60°C flexing) CM
BC = Bare Copper • TC = Tinned Copper
*Based on proper installation techniques in a C-track cable guide.
**24 AWG stranded (41x40) tinned copper drain wire.

Color Codes: Flex Data


Pair No. Color Combination
18 • Industrial Cables

1 White/Blue Stripe & Blue/White Stripe


2 White/Orange Stripe & Orange/White Stripe
3 White/Green Stripe & Green/White Stripe
4 White/Brown Stripe & Brown/White Stripe

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.40

Belden Infinity Flexible Automation Cable ®

75 Ohm Flex Vision Coax Cables


(1 Million Flex Cycles*)

Standard Nominal Nominal Nominal


UL NEC/ Standard Lengths Unit Weight Nom. DCR Core OD Nominal OD Nom. Nom. Capacitance Attenuation
Part Imp. Vel.
Description C(UL) CEC
No. of dB/ dB/
Type Ft. m Lbs. kg Conductor Shield Inch mm Inch mm (Ω) Prop. pF/Ft. pF/m MHz 100 Ft. 100m

Sub-Mini Type • 30 AWG Stranded (7x38) Tinned Cadmium Bronze Conductor • Tinned Copper “French Braid” Shield (95% Coverage)
Foam Polyethylene Insulation • Matte Blue Belflex® Jacket
UL AWM 7500A CEC: 250 † 76.2 3.0 1.4 108.0Ω/M′ 13.3Ω/M′ .056 1.42 .110 2.79 75 78% 16.7 54.8 2.2 .9 2.95
Style 1354 FT1 500 † 152.4 5.0 2.3 354.3Ω/km 43.6Ω/km 5 1.4 4.59
30V 80°C 1000 † 304.8 9.0 4.1 10 2.0 6.56
CSA AWM Ι/ΙΙ A/B 30 3.4 11.16
50 4.4 14.44
100 6.4 21.00

Mini Type • 25 AWG Stranded (19x38) Bare Copper Conductor • Tinned Copper “French Braid” Shield (95% Coverage)
Foam Polyethylene Insulation • Matte Blue Belflex Jacket
UL AWM 7501A CEC: 500 † 152.4 7.5 3.4 35.0Ω/M′ 9.1Ω/M′ .090 2.29 .146 3.71 75 77% 17.7 58.1 2.2 .6 1.97
Style 1354 FT1 1000 † 304.8 14.0 6.4 114.8Ω/km 29.9Ω/km 5 .9 2.95
30V 80°C 10 1.3 4.27
CSA AWM Ι/ΙΙ A/B 30 2.2 7.22
50 2.9 9.52
100 4.2 13.78

RG-59 Type • 22 AWG Stranded (19x34) Bare Copper Conductor • Tinned Copper “French Braid” Shield (95% Coverage)
Foam Polyethylene Insulation • Matte Blue Belflex Jacket
UL AWM 7502A CEC: 250 † 76.2 10.5 4.8 13.4Ω/M′ 6.4Ω/M′ .146 3.71 .242 6.15 75 79% 18.0 59.1 2.2 .4 1.31
Style 1354 FT1 500 † 152.4 15.0 6.8 44.0Ω/km 21.0Ω/km 5 .5 1.64
30V 80°C 1000 † 304.8 34.0 15.4 10 .8 2.63
CSA AWM Ι/ΙΙ A/B 30 1.4 4.59
50 1.8 5.91
100 2.7 8.86

RG-6/U Type • 20 AWG Stranded (7x15x40) Bare Copper Conductor • Tinned Copper “French Braid” Shield (95% Coverage)
Foam Polyethylene Insulation • Matte Blue Belflex Jacket
UL AWM 7503A CEC: 250 † 76.2 12.0 5.5 8.1Ω/M′ 11.0Ω/M′ .185 4.70 .275 6.99 75 80% 17.3 56.8 2.2 .3 0.98
Style 1354 FT1 500 † 152.4 18.0 8.2 26.6Ω/km 36.1Ω/km 5 .4 1.31
30V 80°C 1000 † 304.8 40.0 18.2 10 .6 1.97
CSA AWM Ι/ΙΙ A/B 30 1.1 3.61
50 1.5 4.92
100 2.2 7.22

RG-11 Type • 16 AWG Stranded (7x37x40) Bare Copper Conductor • Tinned Copper “French Braid” Shield (95% Coverage)
Foam Polyethylene Insulation • Matte Blue Belflex Jacket
UL AWM 7504A CEC: 1000 † 304.8 84.0 38.1 3.5Ω/M′ 3.6Ω/M′ .285 7.24 .405 10.29 75 81% 17.3 56.8 2.2 .2 0.66
Style 1354 FT1 11.5Ω/km 11.8Ω/km 5 .3 0.98
30V 80°C 10 .4 1.31
CSA AWM Ι/ΙΙ A/B 30 .8 2.63
50 1.0 3.28
100 1.5 4.92

BC = Bare Copper • DCR = DC Resistance • TC = Tinned Copper


*Based on proper installation techniques in a C-track cable guide.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.41

UL Instrumentation Cable
300V Power-Limited Tray Cables — Overview

Construction Application Specifications

Soft annealed bare or tinned copper with Cable jackets are resistant to sunlight, ● UL Subject 13
PVC flame retardant insulation and jacket. moisture and vapor penetration. PVC/PVC
● UL Subject 2250
Other insulation and jacket options are constructions, with 3 conductors or more
available (see table below). Communication and 20 AWG or larger, are suitable for ● NEC Article 725 Class 2 and
wire included on all multi-pair/multi-triad direct burial. Class 3 Circuits
1000 and 3000 series part numbers, 22 AWG ● NEC Type PLTC Listed, which is
(7x30) bare copper, orange PVC insulation. Unshielded
approved for cable tray use in Class 1,
Nylon rip cord included in all PVC/PVC Twisted non-shielded pairs and triads Division 2, hazardous areas and
instrumentation cables. provide a minimal OD allowing greater tray non-hazardous areas, cable trays,
and conduit fill. Non-shielded instrument raceways, conduit and supported
Other Construction Options: pairs may be utilized when recommended by messenger wires.
by the instrument manufacturer and used
● Sunlight-resistant.
UL Listed for PLTC in a metallic conduit.
● Oil-resistant per UL Class 43
Insulation/Jacket Max. Temp Rating Overall Shield
● NEC Type ITC per Article 727.
XLPE/PVC 90°C Recommended for use in instrumentation ITC cables may carry up to 5 amps
XLPE/CPE 90°C applications where signals are transmitted at 150V, which is significantly greater
PVC/PVC 105°C in excess of 100 millivolts except in areas than that allowed for PLTC only cables.
PVC/CPE 105°C
where high voltage and current sources ITC cables may also be installed in
create excessive noise interference. specific applications, per the NEC,
PE/PVC 75°C
The Beldfoil® shield with drain wire in addition to those allowed for PLTC.
FPE/PVC 75°C
provides 100% coverage for maximum
TPE/TPE 105°C ● UL 1685 (UL 1581) Vertical Tray Flame
shield effectiveness.
XLPE/Haloarrest® 90°C Test comparable to IEEE 383-1974
Individually Shielded and (70,000 BTU/hr.) Flame Test.
Overall Shielded ● PVC/PVC constructions are CMG, FT4,
Armoring Capabilities
Individually shielded pairs or triads with IEEE 1202 and IEEE 383-2003 rated,
an overall shield are recommended for and meet ICEA T-29-520 Flame Test.
Belden also has the capability to protect
electronic, instrumentation and control cables use in instrumentation applications where ● Design options — call 1-800-BELDEN-1
with interlocking or continuous armor and optimum noise rejection is required. or 1-800-BELDEN-3.
smooth or corrugated protective metal tapes. Individual pair/triad shields are fully isolated
from each other and contain a separate PLTC-ER
drain wire for grounding, to provide
To Specify Part Number As an option, Belden offers all PVC insulated,
maximum protection from crosstalk and
1 2 3456 common mode interference. Cables with PVC jacketed instrumentation cables, and
Overall Armor Core
an overall shield provide additional several other insulation and jackets, with a
Jacket Type Trade
Type Number
electrostatic noise protection. PLTC-ER (Exposed Run) rating, formerly
referred to as Open Wiring.
Overall Jacket
Per NEC Article 725, a PLTC-ER rated cable
Code Material may be installed in an industrial establish-
1 PVC ment between a cable tray and the utilization
3 CPE equipment or device. A PLTC-ER rated cable
4 TPE must meet the crush and impact require-
5 HDPE ments of UL Type MC cable By eliminating
6 Oil Res II the need for metal conduit and/or armor,
7 Haloarrest® I using a PLTC-ER rated cable results in
Armor
savings in both installation and maintenance.

Code Material
2 Aluminum Interlock
3 Steel Interlock
8 Continuously Corrugated Aluminum
18 • Industrial Cables

Standard lengths may be subject to tolerance. Custom lengths may be available upon
request. Contact the Belden Electronics Division Customer Service Department for
additional information. 1-800-BELDEN-1 or 1-800-BELDEN-3.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.42

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

22 AWG Pairs Stranded (7x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9407 1 E2 U-500 U-152.4 10.0 4.3 .037 .94 .198 5.03 19 84 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 19.0 8.2
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9322 1 E2 U-500 U-152.4 11.0 5.0 .037 .94 .201 5.10 28 124 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 22.0 10.0
IEEE 1202/383
ICEA T-29-520 9512 2 E2 500 152.4 22.0 10.0 .042 1.07 .310 7.82 46 204 3.00 76.20
1000 304.8 42.0 19.1
Drain Wire 9513 3 E2 500 152.4 26.5 11.6 .042 1.07 .324 8.23 63 280 3.25 82.55
1000 304.8 51.0 23.2
9514 4 E2 500 152.4 33.0 14.8 .042 1.07 .356 9.04 80 355 3.50 88.90
1000 304.8 67.0 30.5
9516 6 E2 500 152.4 45.0 20.4 .053 1.35 .418 10.62 118 524 4.25 107.95
1000 304.8 89.0 40.4
9520 9 E2 500 152.4 64.5 29.3 .053 1.35 .482 12.29 172 765 4.75 120.65
Rip Cord
1000 304.8 121.0 55.0
9521 11 E2 500 152.4 73.0 32.7 .053 1.35 .506 12.85 200 889 5.35 135.89
1000 304.8 147.0 66.4
9524 15 E2 500 152.4 89.5 40.7 .053 1.35 .594 15.09 280 1245 6.00 152.40
1000 304.8 178.0 80.9
9526 19 E2 500 152.4 114.5 52.0 .063 1.60 .644 16.36 350 1557 6.33 160.78
1000 304.8 224.0 101.8
9527 27 E2 500 152.4 156.5 71.1 .063 1.60 .763 19.38 500 2224 7.50 190.50
1000 † 304.8 321.0 145.9

22 AWG Pairs Stranded (7x30) Bare Copper Conductors* • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome)
NEC: PLTC, ITC, CMG 3000A** 2 E1 Bulk†† Bulk — — .043 1.09 .310 7.87 46 204 3.00 76.20
CEC: CMG FT4
IEEE 1202/383 3004A** 4 E1 Bulk†† Bulk — — .042 1.07 .357 9.01 80 355 3.50 88.90
ICEA T-29-520
3006A** 8 E1 Bulk†† Bulk — — .053 1.35 .450 11.43 172 765 4.75 120.65
3008A** 12 E1 Bulk†† Bulk — — .053 1.35 .536 13.61 210 934 5.00 127.00
Drain Wire
3010A** 16 E1 Bulk†† Bulk — — .053 1.35 .594 15.09 290 1290 6.00 152.40
3012A** 24 E1 Bulk†† Bulk — — .065 1.65 .749 19.02 440 1957 7.50 190.50
3014A** 50 E1 Bulk†† Bulk — — .075 1.91 1.017 25.80 915 4070 9.50 241.30

Rip Cord

Communication Wire

PVC = Polyvinyl Chloride


*For tinned copper conductors, order with B suffix.
**For Exposed Run rated cable (3000 series only), order with E suffix, e.g. 3000AE.


Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.
E1, E2 = Refer to Industrial Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.43

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

22 AWG Pairs Stranded (7x30) Tinned Copper Conductors • Twisted Pairs


Individually Shielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9328 2 E2 500 152.4 23.5 10.2 .042 1.07 .323 8.20 54 240 3.00 76.20
CEC: CMG FT4 1000 304.8 46.0 20.9
IEEE 1202/383
ICEA T-29-520 9329 3 E2 500 152.4 29.5 13.4 .042 1.07 .341 8.66 54 240 3.50 88.90
1000 304.8 60.0 27.3
9330 4 E2 500 152.4 39.0 17.7 .042 1.07 .372 9.45 110 489 3.50 88.90
1000 304.8 75.0 34.0
9331 6 E2 500 152.4 55.0 24.5 .053 1.35 .457 11.61 101 449 4.33 109.98
1000 304.8 111.0 50.4
Rip Cord 9332 9 E2 500 152.4 75.0 34.1 .053 1.35 .530 13.46 160 711 5.00 127.00
1000 304.8 145.0 65.9
Drain Wires 9333 11 E2 500 152.4 89.0 40.5 .053 1.35 .592 15.04 160 711 5.50 139.70
1000 304.8 177.0 80.5
9335 19 E2 500 152.4 141.5 64.3 .063 1.60 .711 18.06 264 1174 6.50 165.10
1000 304.8 287.0 130.5

22 AWG Pairs Stranded (7x30) Bare Copper Conductors* • Twisted Pairs


Individually Shielded + Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome)

NEC: PLTC, ITC, CMG 3001A 2 E1 Bulk†† Bulk — — .042 1.07 .324 8.23 54 240 3.25 82.55
CEC: CMG FT4 †
IEEE 1202/383 Communication Wire 3005A 4 E1 Bulk†† Bulk — — .043 1.09 .360 9.14 115 511 3.50 88.90
ICEA T-29-520 †
3007A 8 E1 Bulk†† Bulk — — .053 1.35 .497 12.62 250 1112 5.25 133.35

3009A 12 E1 Bulk†† Bulk — — .053 1.35 .570 14.48 300 1334 5.75 146.05

3011A 16 E1 Bulk†† Bulk — — .064 1.63 .674 17.12 350 1557 6.25 158.75

Rip Cord 3013A 24 E1 Bulk†† Bulk — — .065 1.65 .800 20.32 540 2402 8.00 203.20

Drain Wires 3015A 50 E1 Bulk†† Bulk — — .075 1.91 1.050 26.67 1330 5916 10.50 266.70

22 AWG Triads Stranded (7x30) Tinned Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9491 1 E1 U-500 U-152.4 12.5 5.7 .037 .94 .208 5.28 29 129 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 23.0 10.4
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9363 1 E1 U-500 U-152.4 13.5 6.1 .037 .94 .208 5.28 29 129 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 26.0 11.8
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

22 AWG Triads Stranded (7x30) Bare Copper Conductors* • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome)
NEC: PLTC, ITC, CMG 3002A 2 E1 Bulk†† Bulk — — .043 1.09 .330 8.38 62 275 3.50 88.90
CEC: CMG FT4
IEEE 1202/383
ICEA T-29-520

For Exposed Run rated cable, order 3002AE

Rip Cord Communication


Drain Wire Wire
Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket (Black or Chrome)
NEC: PLTC, ITC, CMG 3003A 2 E1 Bulk†† Bulk — — .043 1.09 .330 8.38 82 364 3.25 82.55
18 • Industrial Cables

CEC: CMG FT4


IEEE 1202/383
ICEA T-29-520

For Exposed Run rated cable, order 3003AE

Rip Cord
Communication
Drain Wires Wire
*For tinned copper conductors, order with B suffix. E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request.

For Exposed Run rated 3000 series cables, order with “E” suffix, e.g. 3001AE. Multiple pair or triad cables have each pair/triad numbered for ease of identification.
††
Bulk = Check length available for specific construction.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.44

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

20 AWG Pairs Stranded (19x32) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9408 1 E2 U-500 U-152.4 12.0 5.5 .037 .94 .214 5.44 31 138 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 23.0 10.4
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9320 1 E2 U-500 U-152.4 14.5 6.6 .037 .94 .217 5.51 40 178 2.00 50.80
CEC: CMG FT4 U-1000 U-304.8 28.0 12.7
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

20 AWG Pairs Stranded (7x28) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1033A 1 E1 1000 304.8 30.0 13.6 .037 .94 .213 5.41 42 187 2.25 57.15
CEC: CMG FT4 10000 † 3048.0 270.0 122.5
IEEE 1202/383
ICEA T-29-520 3016A 2 E1 Bulk †† Bulk — — .042 1.07 .332 8.43 92 409 3.75 95.25
1056A 4 E1 10000 † 3048.0 820.0 372.0 .053 1.35 .408 10.36 135 601 4.25 107.95
1057A 8 E1 10000 † 3048.0 1410.0 640.2 .053 1.35 .472 11.99 247 1099 5.00 127.00
1058A 12 E1 7500 † 2286.0 1455.0 660.0 .053 1.35 .564 14.33 359 1597 6.00 152.40
Rip Cord 1059A 16 E1 5000 † 1524.0 1275.0 578.9 .064 1.63 .649 16.48 232 1032 6.50 165.10
Drain Wire
1060A 24 E1 5000 † 1524.0 1735.0 787.7 .064 1.63 .786 19.96 695 3092 8.25 209.55
Communication Wire
1061A 36 E1 2500 † 762.0 1300.0 590.2 .074 1.88 .960 24.38 1031 4587 10.00 254.00
1062A 50 E1 2500 † 762.0 1825.0 827.8 .074 1.88 1.117 28.37 1423 6330 11.50 292.10
Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below)
NEC: PLTC, ITC, CMG 1075A 2 E1 10000 † 3048.0 650.0 294.8 .042 1.07 .337 8.56 97 432 3.75 95.25
CEC: CMG FT4
IEEE 1202/383 1076A 4 E1 7500 † 2286.0 787.5 357.5 .053 1.35 .411 10.44 171 761 4.50 114.30
ICEA T-29-520
1077A 8 E1 7500 † 2286.0 1297.5 588.6 .053 1.35 .514 13.06 320 1424 5.50 139.70
1078A 12 E1 7500 † 2286.0 1942.5 881.1 .064 1.63 .637 16.18 468 2082 6.75 171.45
1079A 16 E1 5000 † 1524.0 1555.0 705.4 .064 1.63 .704 17.88 617 2745 7.50 190.50
1091A 20 E1 Bulk †† Bulk — — .064 1.63 .780 19.81 765 3403 8.25 209.55
Rip Cord 1080A 24 E1 2500 † 762.0 1142.5 518.2 .074 1.88 .863 21.92 914 4066 9.00 228.60
Drain Wires 1081A 36 E1 2000 † 609.6 1436.0 651.9 .074 1.88 1.035 26.29 1359 6046 10.50 266.70
Communication Wire
1082A 50 E1 2000 † 609.6 1858.0 843.5 .074 1.88 1.215 30.86 1878 8355 12.75 323.85
F-R = Flame-retardant

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.
E1, E2 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.45

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Part Color
Description of
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

20 AWG Triads Stranded (19x32) Tinned Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9492 1 E1 U-500 U-152.4 15.5 7.0 .037 .94 .225 5.72 46 205 2.25 57.15
CEC: CMG FT4 U-1000 U-304.8 29.0 13.2
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9364 1 E1 U-500 U-152.4 17.0 7.7 .037 .94 .228 5.79 46 205 2.25 57.15
CEC: CMG FT4 U-1000 U-304.8 32.0 14.5
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

20 AWG Triads Stranded (7x28) Bare Copper Conductors • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1526A 1 E1 10000 † 3048.0 310.0 140.6 .037 .94 .215 5.46 42 187 2.20 55.88
CEC: CMG FT4
IEEE 1202/383 3017A 2 E1 Bulk †† Bulk — — .055 1.40 .360 9.14 97 432 3.60 91.44
ICEA T-29-520
3020A 4 E1 Bulk †† Bulk — — .055 1.40 .470 11.94 174 774 4.75 120.65
3021A 8 E1 Bulk †† Bulk — — .055 1.40 .560 14.22 330 1468 5.00 127.00
3022A 12 E1 Bulk †† Bulk — — .066 1.68 .710 18.03 485 2158 7.00 177.80
Rip Cord 3023A 16 E1 Bulk †† Bulk — — .064 1.63 .821 20.85 600 2669 7.75 196.85

Drain Wire 3024A 24 E1 Bulk †† Bulk — — .074 1.88 1.031 26.19 920 4093 9.25 234.95
Communication Wire

Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below)
NEC: PLTC, ITC, CMG 3018A 2 E1 Bulk †† Bulk — — .055 1.40 .372 9.45 102 454 3.75 95.25
CEC: CMG FT4
IEEE 1202/383 1083A 4 E1 10000 † 3048.0 1410.8 640.9 .053 1.35 .451 11.46 228 1014 4.50 114.30
ICEA T-29-520
1084A 8 E1 7500 † 2286.0 1755.0 796.1 .064 1.63 .575 10.81 432 1922 5.75 146.05
1085A 12 E1 5000 † 1524.0 1735.0 787.0 .064 1.63 .714 18.14 636 2829 7.15 181.61
1092A 16 E1 Bulk †† Bulk — — .064 1.63 .793 20.14 841 3741 7.90 200.66
1086A 24 E1 2500 † 762.0 1602.5 726.9 .074 1.88 .992 25.20 1250 5561 9.90 251.46
Rip Cord
3067A 36 E1 Bulk †† Bulk — — .074 1.88 1.292 32.82 1875 6273 13.00 330.20
Drain Wires
Communication Wire

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.
E1 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.
18 • Industrial Cables

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.46

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

18 AWG Pairs Stranded (19x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9409 1 E2 U-500 U-152.4 15.0 6.8 .037 .94 .230 5.84 49 218 2.25 57.15
CEC: CMG FT4 U-1000 U-304.8 28.0 12.7
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9318 1 E2 U-500 U-152.4 17.5 7.9 .037 .94 .233 5.92 60 267 2.25 57.15
CEC: CMG FT4 U-1000 U-304.8 33.0 15.0
IEEE 1202/383
ICEA T-29-520 9552 2 E2 500 152.4 35.5 16.1 .042 1.07 .368 9.34 65 289 3.70 93.98
1000 304.8 69.0 31.4
Drain Wire
9553 3 E2 500 152.4 49.5 22.0 .053 1.35 .411 10.44 145 645 4.10 104.14
1000 304.8 98.0 49.4
9554 4 E2 500 152.4 57.0 25.8 .053 1.35 .447 11.35 187 832 4.50 114.30
1000 304.8 112.0 50.8
9556 6 E2 500 152.4 78.5 35.7 .053 1.35 .497 12.62 270 1201 5.00 127.00
Rip Cord
1000 304.8 153.0 69.5
9559 9 E2 500 152.4 108.0 49.0 .053 1.35 .579 14.71 395 1757 5.80 147.32
1000 304.8 215.0 97.6
9563 11 E2 500 152.4 133.0 60.4 .063 1.60 .665 16.89 478 2126 6.75 171.45
1000 304.8 270.0 122.5
9565 15 E2 500 152.4 169.0 76.8 .063 1.60 .739 18.77 640 2847 7.50 190.50
1000 304.8 342.0 155.5
Individually Shielded (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9368 2 E2 500 152.4 37.5 17.0 .042 1.07 .378 9.60 125 556 3.75 95.25
CEC: CMG FT4 1000 304.8 73.0 33.2
IEEE 1202/383
ICEA T-29-520 9369 3 E2 500 152.4 55.0 25.0 .053 1.35 .423 10.74 220 979 4.25 107.95
1000 304.8 109.0 49.5
3029A 4 E1 Bulk † Bulk — — .053 1.35 .461 11.71 296 1317 4.50 114.30
9388 4 E2 500 152.4 71.5 32.5 .053 1.35 .461 11.71 296 1317 4.60 116.84
1000 304.8 135.0 61.4
Rip Cord
9389 6 E2 500 152.4 97.0 44.1 .053 1.35 .538 13.67 440 1957 5.25 133.35
Drain Wire 1000 304.8 190.0 86.4
9390 9 E2 500 152.4 137.5 63.0 .064 1.63 .652 16.56 666 2963 6.50 165.10
1000 304.8 270.0 123.6
9391 11 E2 500 152.4 158.5 72.0 .064 1.63 .729 18.52 815 3626 7.25 184.15
1000 304.8 321.0 145.9
9392 15 E2 500 152.4 209.0 95.0 .064 1.63 .808 20.52 1100 4893 8.00 203.20
1000 304.8 428.0 194.5
E1, E2 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.47

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

18 AWG Pairs Stranded (7x26) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1032A 1 E1 1000 304.8 38.0 17.2 .037 .94 .233 5.92 67 298 2.50 63.50
CEC: CMG FT4 10000 † 3048.0 380.0 172.5
IEEE 1202/383
ICEA T-29-520 3025A 2 E1 10000 † 3048.0 760.0 344.7 .042 1.07 .375 9.53 121 538 3.50 88.90
Drain Wire 1529A 3 E1 7500 † 2286.0 735.0 333.4 .053 1.35 .415 10.54 165 734 4.25 107.95
1466A 4 E1 7500 † 2286.0 892.5 404.8 .053 1.35 .452 11.48 211 939 4.50 114.30
1467A 8 E1 7500 † 2286.0 1477.5 670.8 .053 1.35 .523 13.28 390 1735 5.50 139.70
1468A 12 E1 5000 † 1524.0 1375.0 624.3 .064 1.63 .673 17.09 560 2491 6.75 171.45
3034A 16 E1 Bulk †† Bulk — — .066 1.68 .713 18.11 640 2847 7.25 184.15
1471A 24 E1 2500 † 762.0 1292.5 586.3 .074 1.88 .932 23.67 1105 4916 9.25 234.95
Rip Cord
1472A 36 E1 1250 † 381.0 910.0 413.1 .074 1.88 1.062 26.97 1644 7313 10.50 266.70
Communication Wire
3041A 50 E1 Bulk †† Bulk — — .074 1.88 1.240 31.50 2240 10049 12.75 323.85
Individually Shielded + Overall Beldfoil (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below)
NEC: PLTC, ITC, CMG 1474A 2 E1 7500 † 2286.0 720.0 326.9 .053 1.35 .408 10.16 149 663 4.00 101.60
CEC: CMG FT4
IEEE 1202/383 1475A 4 E1 7500 † 2286.0 1065.0 483.1 .053 1.35 .468 11.89 267 1188 4.75 120.65
ICEA T-29-520
1476A 8 E1 5000 † 1524.0 1185.0 538.0 .053 1.35 .594 15.10 501 2229 6.00 152.40
1477A 12 E1 5000 † 1524.0 1740.0 789.3 .064 1.63 .737 18.72 779 3465 7.25 184.15
3035A 16 E1 Bulk †† Bulk — — .064 1.63 .836 21.20 725 3225 8.50 215.90

Rip Cord
1480A 24 E1 2500 † 762.0 1712.5 777.5 .074 1.88 1.019 25.88 1443 6419 10.25 260.35
5000 † 1524.0 3390.0 1539.1
Drain Wires
Communication Wire 1481A 36 E1 Bulk †† Bulk — — .074 1.88 1.163 29.54 2148 9556 11.75 298.45
3042A 50 E1 Bulk †† Bulk — — .084 2.13 1.389 35.28 2935 13057 14.00 355.60
E1 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.

18 • Industrial Cables

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.48

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

18 AWG Triads Stranded (19x30) Tinned Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9493 1 E1 U-500 U-152.4 20.0 9.1 .037 .94 .242 6.15 62 276 2.25 57.15
CEC: CMG FT4 U-1000 U-304.8 38.0 17.2
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9365 1 E1 U-500 U-152.4 22.0 10.0 .037 .94 .245 6.22 74 329 2.50 63.50
CEC: CMG FT4 U-1000 U-304.8 43.0 19.5
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

18 AWG Triads Stranded (7x26) Bare Copper Conductors • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1036A 1 E1 1000 304.8 43.0 19.5 .037 .94 .236 5.99 90 400 2.40 60.96
CEC: CMG FT4 10000 † 3048.0 430.0 195.1
IEEE 1202/383
ICEA T-29-520 3027A 2 E1 Bulk †† Bulk — — .055 1.40 .420 10.67 165 734 4.25 107.95
3030A 4 E1 Bulk †† Bulk — — .055 1.40 .521 13.20 240 1068 4.50 114.30
3032A 8 E1 Bulk †† Bulk — — .064 1.63 .580 14.70 501 2229 5.75 146.05
3036A 16 E1 Bulk †† Bulk — — .077 1.96 .900 22.86 1050 4671 9.00 228.60
Rip Cord
3038A 24 E1 Bulk †† Bulk — — .077 1.96 1.020 25.91 1450 6450 10.25 260.35
Drain Wire
Communication Wire

Individually Shielded + Overall Beldfoil (100% Coverage) • PVC Insulation • Black PVC Jacket (Other options below)
NEC: PLTC, ITC, CMG 3028A 2 E1 Bulk †† Bulk — — .055 1.40 .450 11.43 175 779 4.50 114.30
CEC: CMG FT4
IEEE 1202/383 3031A 4 E1 Bulk †† Bulk — — .053 1.35 .533 13.50 255 1134 5.25 133.35
ICEA T-29-520
3033A 8 E1 Bulk †† Bulk — — .064 1.63 .654 16.50 560 2491 6.50 165.10
3068A 12 E1 Bulk †† Bulk — — .063 1.60 .840 21.30 800 3559 8.50 215.90
3037A 16 E1 Bulk †† Bulk — — .074 1.88 .974 24.70 1320 5872 10.50 266.70
3039A 24 E1 Bulk †† Bulk — — .074 1.88 1.200 30.50 1620 7207 11.25 285.75
Rip Cord
Drain Wires
Communication Wire

E1 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.49

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

16 AWG Pairs Stranded (19x29) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9410 1 E2 U-500 U-152.4 18.5 8.4 .037 .94 .254 6.45 78 347 2.50 63.50
CEC: CMG FT4 U-1000 U-304.8 36.0 16.3
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9316 1 E2 U-500 U-152.4 21.5 9.8 .037 .94 .256 6.50 90 400 2.50 63.50
CEC: CMG FT4 U-1000 U-304.8 41.0 18.6
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

16 AWG Pairs Stranded (7x24) Bare Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Black PVC Jacket (See chart below for other insulation and jacket options)
NEC: PLTC, ITC, CMG 1035A 1 E1 1000 304.8 40.0 18.1 .037 .94 .254 6.45 71 318 2.50 63.50
CEC: CMG FT4 10000 † 3048.0 400.0 181.4
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1030A 1 E1 1000 304.8 46.0 20.9 .037 .94 .257 6.53 94 418 2.50 63.50
CEC: CMG FT4 10000 † 3048.0 480.0 217.7
IEEE 1202/383
ICEA T-29-520 3043A 2 E1 Bulk †† Bulk — — .053 1.35 .437 11.10 83 369 4.50 114.30
Drain Wire 1528A 3 E1 7500 † 2286.0 967.5 438.9 .053 1.35 .457 11.61 250 1112 4.75 120.65
1484A 4 E1 7500 † 2286.0 1200.0 544.8 .053 1.35 .495 12.57 330 1468 5.00 127.00
1485A 8 E1 7500 † 2286.0 2010.0 911.7 .053 1.35 .597 15.16 616 2740 6.00 152.40
1486A 12 E1 5000 † 1524.0 1965.0 892.1 .064 1.63 .741 18.80 892 3968 7.50 190.50
3050A 16 E1 Bulk †† Bulk — — .064 1.63 .831 21.10 661 2940 8.50 215.90
Rip Cord 1489A 24 E1 1250 † 381.0 923.8 419.4 .074 1.88 1.032 26.20 1749 7780 10.50 266.70
1490A 36 E1 1250 † 381.0 1313.8 596.4 .074 1.88 1.178 29.80 2606 11592 11.75 298.45
Communication Wire
3056A 50 E1 Bulk †† Bulk — — .088 2.24 1.550 39.37 3615 16082 15.50 393.70
Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Options below)
NEC: PLTC, ITC, CMG 1492A 2 E1 7500 † 2286.0 885.0 401.8 .053 1.35 .450 11.43 232 1032 4.50 114.30
CEC: CMG FT4
IEEE 1202/383 1493A 4 E1 7500 † 2286.0 1387.5 629.4 .055 1.40 .512 13.11 420 1868 5.00 127.00
ICEA T-29-520
1494A 8 E1 5000 † 1524.0 1640.0 743.9 .066 1.68 .687 17.50 795 3537 7.00 177.80
1495A 12 E1 2500 † 762.0 1202.5 545.5 .066 1.68 .822 20.73 1170 5205 8.25 209.55
3051A 16 E1 Bulk †† Bulk — — .074 1.88 .936 23.77 661 2940 10.00 254.00
1498A 24 E1 5000 † 1524.0 4340.0 1968.6 .074 1.88 1.149 29.18 2296 10214 11.50 292.10
Rip Cord
Drain Wires 1499A 36 E1 Bulk †† Bulk — — .084 2.13 1.334 33.88 3167 14088 13.50 342.90
Communication Wire 3057A 50 E1 Bulk †† Bulk — — .088 2.24 1.600 40.64 2066 9190 16.00 406.40
E1, E2 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
18 • Industrial Cables

Multiple pair or triad cables have each pair/triad numbered for ease of identification. Conductor, Insulation and Jacket Options**

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction. To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.50

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

16 AWG Triads Stranded (19x29) Tinned Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9494 1 E1 U-500 U-152.4 24.5 11.1 .037 .94 .268 6.81 91 405 2.75 69.85
CEC: CMG FT4 U-1000 U-304.8 48.0 21.8
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage)• PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CMG 9366 1 E1 U-500 U-152.4 27.5 12.5 .037 .94 .270 6.86 116 516 2.75 69.85
CEC: CMG FT4 U-1000 U-304.8 54.0 24.5
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

16 AWG Triads Stranded (7x24) Bare Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1034A 1 E1 1000 304.8 51.0 23.2 .037 .94 .268 6.81 107 476 2.75 69.85
CEC: CMG FT4 4000 † 1219.2 208.0 94.4
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CMG 1031A 1 E1 1000 304.8 58.0 26.4 .037 .94 .271 6.88 130 578 2.75 69.85
CEC: CMG FT4 10000 † 3048.0 610.0 276.7
IEEE 1202/383
ICEA T-29-520 3044A 2 E1 Bulk †† Bulk — — .053 1.35 .483 12.27 259 1152 4.75 120.65
3046A 4 E1 Bulk †† Bulk — — .053 1.35 .570 14.40 473 2104 5.75 146.05
3048A 8 E1 Bulk †† Bulk — — .063 1.60 .760 19.30 902 4013 7.50 190.50
3052A 16 E1 Bulk †† Bulk — — .074 1.88 1.032 26.21 1758 7821 11.25 285.75
Rip Cord
3054A 24 E1 Bulk †† Bulk — — .074 1.88 1.180 29.90 2615 11633 11.75 298.45
Drain Wire
Communication Wire

Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (Options below)
NEC: PLTC, ITC, CMG 3045A 2 E1 Bulk †† Bulk — — .053 1.35 .506 12.80 304 1352 5.00 127.00
CEC: CMG FT4
IEEE 1202/383 3047A 4 E1 Bulk †† Bulk — — .053 1.35 .569 14.45 563 2505 6.00 152.40
ICEA T-29-520
3049A 8 E1 Bulk †† Bulk — — .064 1.63 .764 19.41 1081 4809 8.00 203.20
3069A 12 E1 Bulk †† Bulk — — .074 1.88 .998 25.35 1500 6673 10.00 254.00
3053A 16 E1 Bulk †† Bulk — — .074 1.88 1.150 29.20 2117 9418 11.50 292.10
3055A 24 E1 Bulk †† Bulk — — .084 2.13 1.320 33.53 3153 14026 13.25 336.55
Rip Cord
Drain Wires
Communication Wire

E1 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.
Conductor, Insulation and Jacket Options**
To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.51

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

14 AWG Pairs Stranded (42x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9411 1 E2 U-500 U-152.4 28.0 12.7 .042 1.07 .322 8.18 124 552 3.25 82.55
CEC: FT4 1000 304.8 60.0 27.3
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9314 1 E2 U-500 U-152.4 32.5 14.7 .042 1.07 .324 8.23 140 623 3.25 82.55
CEC: FT4 1000 304.8 66.0 29.9
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

14 AWG Triads Stranded (42x30) Tinned Copper Conductors • Twisted Triads


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9495 1 E1 500 152.4 43.5 19.7 .042 1.07 .340 8.64 186 827 3.50 88.90
CEC: FT4 1000 304.8 86.0 39.0
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9367 1 E1 500 152.4 43.5 19.7 .042 1.07 .343 8.71 188 836 3.50 88.90
CEC: FT4 1000 304.8 88.0 40.0
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.52

UL Instrumentation Cable
300V Power-Limited Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

12 AWG Pairs Stranded (65x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9412 1 E2 500 152.4 41.5 18.8 .042 1.07 .370 9.40 197 876 4.25 107.95
CEC: FT4 1000 304.8 83.0 37.7
IEEE 1202/383
ICEA T-29-520

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • Chrome PVC Jacket
NEC: PLTC, ITC, CL3R 9312 1 E2 500 152.4 49.0 22.3 .042 1.07 .373 9.47 225 1001 4.25 107.95
CEC: FT4 1000 304.8 96.0 43.6
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

12 AWG Triads Stranded (7x20) Bare Copper Conductors • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC Insulation • Black PVC Jacket (See chart below for other options)
NEC: PLTC, ITC, CL3R 3102A 1 E1 Bulk † Bulk — — .053 1.35 .432 11.00 315 1401 3.50 88.90
CEC: FT4
IEEE 1202/383
ICEA T-29-520

Rip Cord
Drain Wire

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.

Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating K L TPE/TPE
No. for desired if desired
conductor, Q R XLPE/CPE
insulation & jacket
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53

UL Instrumentation Cable
Thermocouple Extension Cables and Thermocouple Wire — Overview

Construction Thermocouple Application ● NEC Type ITC Listed, which is approved


Extension Cable for cable tray use, raceways hazardous
Unshielded locations according to Articles 501, 502,
Conductor material determined by the 503 and 504; or as aerial on a cable
Parallel non-shielded extension wire may
thermocouple extension wire type. FEP be utilized in low noise environments messenger, and under raised floors in
or PVC insulated with FEP or PVC jacket. when recommended by the instrument control rooms and rack rooms where
Nylon rip cord included in all PVC-jacketed manufacturer. arranged to prevent damage to the cable.
thermocouple extension cables. Communi- Usages are allowed based on qualified
cation wire included on all multi-pair, Overall Shield persons servicing all installations.
PVC constructions — 22 AWG (7x30) bare Recommended, except in areas where high ● PVC/PVC constructions are CMG, FT4,
copper orange PVC insulation. voltage and current sources create excessive IEEE 1202 and IEEE 383-2003 rated,
noise interference. The Beldfoil® shield with and meet ICEA T-29-520 Flame Test.
NOTE: The temperature ranges in Table A drain wire provides 100% coverage for
● UL 1277 TC versions approved for use
are applicable only to the thermocouple maximum shield effectiveness.
conductors and not to the cable. The cable in Class 1 trays available as special.
must never be exposed to temperatures Individually Shielded
higher than the maximum temperature Individually shielded pairs are recommended Shielded Twisted Pair
(FEP insulated, FEP jacketed
ratings shown in Table B. for use in applications where optimum noise
cable specifications)
rejection is required.
● UL Subject 13
Table B: ● NFPA 262 (UL 910 Steiner Tunnel Flame
Other Insulation/Jacket Options PVC Insulated, PVC Jacketed
Test) comparable to FT6 Flame Test
Cable Specifications
● ANSI/MC 96.1–1982
UL Listed for PLTC ● UL Subject 13
● NEC Type CL3P/PLTC Listed, which is
● UL 1685 (UL 1581) Vertical Tray Flame approved for use in ducts, plenums and
Insulation/Jacket Max. Temp Rating
Test comparable to IEEE 383-1974 other space used for environmental air.
XLPE/PVC 90°C (70,000 BTU) Flame Test
● UL 1277 TC versions approved for use
XLPE/CPE 90°C
● ANSI/MC 96.1–1982 in Class 1 trays available as special.
PVC/PVC 105°C
PVC/CPE 105°C ● NEC CMG
Thermocouple Wire
PE/PVC 75°C ● NEC Type PLTC Listed, which is
Conductor material determined by the
FPE/PVC 75°C approved for cable tray use in Class 1,
thermocouple type. FEP insulated and
TPE/TPE 105°C Division 2, hazardous areas and
jacketed flat constructions.
XLPE/Haloarrest® 90°C
non-hazardous areas, cable trays,
raceways, conduit and supported FEP thermocouple wire is impervious to
FEP/FEP 200°C by messenger wires. chemical attack and is flame retardant.

Table A: Thermocouple Identification and Limits of Error — Reference Junction 0°C*

Temperature Insulation Color Code Conductor Identification


ANSI Limits of Error Jacket
Range (°C)
Symbol Standard (°C) Color
(conductor only) Positive ( + ) Negative ( - ) Positive ( + ) Negative ( - )

E 0 to 340 ±1.7°C Brown Purple Red Chromel® Constantan


340 to 540 ±.50% Non-magnetic Silver Color
J 0 to 293 ±2.2°C Brown White Red Iron Constantan
293 to 480 ±.75% Magnetic Non-magnetic
K 0 to 293 ±2.2°C Brown Yellow Red Chromel Alumel®
293 to 980 ±.75% Non-magnetic Magnetic
T 0 to 133 ±1.0°C Brown Blue Red Copper Constantan
133 to 260 ±.75% Copper Color Non-magnetic
EX 0 to 200 ±1.7°C Purple Purple Red Chromel Constantan
JX 0 to 200 ±2.2°C Black White Red Iron Constantan
KX 0 to 200 ±2.2°C Yellow Yellow Red Chromel Alumel
TX 0 to 100 ±1.0°C Blue Blue Red Copper Constantan
Limits of error per ANSI MC96.1-1982. Limits shown do not include system or installation error. Percentages refer to the temperature being measured.
18 • Industrial Cables

*The Temperature Range and Limits of Error are for standard grade thermocouples, Reference ANSI MC96.1-1982 for special grade thermocouples.
The Temperature Ranges for type E, J, K and T thermocouple wires listed above pertain to 20 AWG wire.
Additional constructions available upon request.

Standard lengths may be subject to tolerance. Custom lengths may be available upon
request. Contact the Belden Electronics Division Customer Service Department for
additional information. 1-800-BELDEN-1

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.54

UL Instrumentation Cable
Thermocouple Extension Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Insulation Nominal


Part ANSI No. Lengths Unit Weight Thickness OD
Color Jacket
Description of
No. Type Code Color
Pairs Ft. m Lbs. kg Inch mm Inch mm

20 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Overall Beldfoil® Shield (100% Coverage) • PVC Insulation • PVC Jacket
300V 105°C 3111A JX 1 White, Red Black 5000 † 1524.0 115.0 52.2 .016 .41 .206 5.23
NEC: PLTC, ITC, CMG
CEC: CMG FT4 3112A KX 1 Yellow, Red Yellow 5000 † 1524.0 120.0 54.5 .016 .41 .206 5.23
ICEA T-29-520
IEEE 1202/383 3113A TX 1 Blue, Red Blue 5000 † 1524.0 115.0 52.2 .016 .41 .206 5.23

Rip Cord
Drain Wire

Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket
300V 105°C 3115A JX 2 White, Red Black 5000 † 1524.0 315.0 143.0 .016 .41 .332 8.43
NEC: PLTC, ITC, CMG
CEC: CMG FT4 1006A JX 4 White, Red Black 5000 † 1524.0 480.0 217.9 .016 .41 .383 9.73
ICEA T-29-520
IEEE 1202/383 1012A KX 4 Yellow, Red Yellow 5000 † 1524.0 530.0 240.6 .016 .41 .383 9.73
1013A KX 8 Yellow, Red Yellow 5000 † 1524.0 825.0 374.6 .016 .41 .503 12.78
1014A KX 12 Yellow, Red Yellow 5000 † 1524.0 1195.0 542.5 .016 .41 .603 15.32

Rip Cord
Drain Wires
Communication Wire

16 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Overall Beldfoil Shield (100% Coverage) • PVC Insulation • PVC Jacket
300V 105°C 1101A EX 1 Purple, Red Purple 10000 † 3048.0 450.0 204.3 .017 .43 .248 6.30
NEC: PLTC, ITC, CMG
CEC: CMG FT4 1000A JX 1 White, Red Black 1000 304.8 42.0 19.1 .017 .43 .248 6.30
ICEA T-29-520 10000 † 3048.0 420.0 190.7
IEEE 1202/383
1018A KX 1 Yellow, Red Yellow 1000 304.8 42.0 19.1 .017 .43 .248 6.30
10000 † 3048.0 420.0 190.7
1023A TX 1 Blue, Red Blue 10000 † 3048.0 450.0 204.3 .017 .43 .248 6.30
Rip Cord
Drain Wire

Multiple pair cables have each pair numbered for ease of identification.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.55

UL Instrumentation Cable
High-Temperature Thermocouple Extension Cables and Thermocouple Wire
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Insulation Nominal


Part ANSI of Color Jacket Lengths Unit Weight Thickness OD
Description Pairs/
No. Type Code Color
Cond. Ft. m Lbs. kg Inch mm Inch mm

High-Temp Extension Cable • 20 AWG Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Plenum • Unshielded • FEP Insulation • FEP Jacket
300V 200°C 83932 KX 2/c Yellow, Red Yellow 500 † 152.4 6.5 3.0 .010 .25 .076 1.93
NEC: PLTC, CL3P 1000 † 304.8 12.0 5.4 x x
.128 3.25
83934 TX 2/c Blue, Red Blue 1000 † 304.8 13.0 6.0 .010 .25 .076 1.93
x x
.128 3.25

High-Temp Extension Cable • 20 AWG Stranded (7x28) Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Plenum • Unshielded • FEP Insulation • FEP Jacket
300V 200°C 83930 JX 2/c White, Red Black 500 † 152.4 7.5 3.4 .010 .25 .082 2.08
NEC: PLTC, CL3P 1000 † 304.8 13.0 6.0 x x
.140 3.56

Plenum • Overall Beldfoil® Shield (100% Coverage) • FEP Insulation • FEP Jacket
300V 200°C 83955 EX 1 pr. Purple, Red Purple 500 † 152.4 9.0 4.1 .010 .25 .145 3.68
NEC: PLTC, CL3P 1000 † 304.8 16.0 7.3
83950 JX 1 pr. White, Red Black 500 † 152.4 9.5 4.3 .010 .25 .145 3.68
1000 † 304.8 16.0 7.3
83952 KX 1 pr. Yellow, Red Yellow 500 † 152.4 9.5 4.3 .010 .25 .145 3.68
Drain Wire
1000 † 304.8 16.0 7.3
83954 TX 1 pr. Blue, Red Blue 500 † 152.4 9.0 4.1 .010 .25 .145 3.68
1000 † 304.8 17.0 7.7

High-Temp Extension Cable • 16 AWG Pairs Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Plenum • Overall Beldfoil Shield (100% Coverage) • FEP Insulation • FEP Jacket
300V 200°C 1114A EX 1 Purple, Red Purple 5000 † 1524.0 160.0 72.6 .010 .25 .172 4.37
NEC: PLTC, CL3P 1115A JX 1 White, Red Black 5000 † 1524.0 155.0 70.4 .010 .25 .172 4.37
1116A KX 1 Yellow, Red Yellow 5000 † 1524.0 160.0 72.6 .010 .25 .171 4.34

Drain Wire
1117A TX 1 Blue, Red Blue 5000 † 1524.0 160.0 72.6 .010 .25 .172 4.37

High-Temp Extension Cable • 16 AWG Pairs Stranded (7x24) Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Plenum • Overall Beldfoil Shield (100% Coverage) • FEP Insulation • FEP Jacket
300V 200°C 83951 JX 1 White, Red Black 500 † 152.4 16.0 7.3 .010 .25 .189 4.80
NEC: PLTC, CL3P 1000 † 304.8 35.0 15.9
83953 KX 1 Yellow, Red Yellow 500 † 152.4 16.0 7.3 .010 .25 .187 4.75
1000 † 304.8 32.0 14.5
Drain Wire

High-Temp Thermocouple Wire • 20 AWG Solid Conductors • (See chart on page 18.53 for conductor specifications by ANSI Type)
Plenum • Unshielded • FEP Insulation • FEP Jacket
300V 200°C 83915 E 2/c Purple, Red Brown 500 † 152.4 7.0 3.2 .010 .25 .076 1.93
NEC: PLTC, CL3P 1000 † 304.8 13.0 6.0 x x
.128 3.25
83900 J 2/c White, Red Brown 100 30.5 2.1 1.0 .010 .25 .076 1.93
500 † 152.4 7.0 3.2 x x
1000 † 304.8 13.0 6.0 .128 3.25
18 • Industrial Cables

83905 K 2/c Yellow, Red Brown 100 30.5 2.1 1.0 .010 .25 .076 1.93
500 † 152.4 7.0 3.2 x x
1000 † 304.8 12.0 5.4 .128 3.25
83910 T 2/c Blue, Red Brown 100 30.5 2.1 1.0 .010 .25 .076 1.93
500 † 152.4 7.0 3.2 x x
1000 † 304.8 12.0 5.4 .128 3.25
FEP = Fluorinated Ethylene-propylene Multiple pair cables have each pair numbered for ease of identification.

Final put-up length may vary ±10% from length shown.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.56

UL Instrumentation Cable
600V Tray Cables – Overview

Tray Cable Construction Options Specifications


● UL Subject 1277 TC
UL Listed for MC and TC
● UL 1685 (UL1581) Vertical Tray Flame
Max. Temp Rating
Insulation/Jacket Flame Tests Ratings* Test comparable to IEEE 383-1974
Wet Dry
(70,000 BTU/hr.) Flame Test
PVC-Nylon/PVC 75°C 90°C UL 1685 ICEA S-73-532
(THHN or THWN) FT4/IEEE 1202/383 ICEA S-61-402 ● NEC Type TC Listed, which is approved
14 AWG & larger ICEA T-29-520 for cable tray use in Class 1, Division 2
PVC-Nylon/PVC N/A 90°C UL 1685 ICEA S-73-532 areas, per NEC Articles 340, 318 and
(TFN or TFFN) FT4/IEEE 1202/383 ICEA S-61-402 501 and for Class 1 circuits as permitted
16 & 18 AWG ICEA T-29-520
in Article 725
XLPE/PVC or CPE 90°C 90°C UL 1685 ICEA S-73-532
(XHHW–2) FT4/IEEE 1202/383 ICEA S-66-524 ● PVC-nylon/PVC constructions are
14 AWG & larger VW-1 rated singles NEC Type NPLF Listed, which is
ICEA T-29-520
approved for use in Non Power-Limited
XLPE/PVC or CPE 75°C 75°C UL 1685 ICEA S-73-532
(RFH–2) FT4/IEEE 1202/383 ICEA S-66-524
Fire Protective Signaling circuits,
16 & 18 AWG VW-1 rated singles ICEA S-82-552 per NEC Article 760
ICEA T-29-520 ● PVC-Nylon/PVC, XLPE/PVC and
FRPO/PVC — 75°C UL 1685 XLPE/CPE constructed cables meet
18 AWG & larger
IEEE 1202/IEEE 383-2003/FT4
TPE/TPE 75°C 90°C UL 1685
(70,000 BTU) Flame Test
FRPO/PVC 75°C 90°C UL 1685
XLPE/Haloarrest® 90°C 90°C UL 1685 TC-LS ● XLPE/Haloarrest cables are
(XHHW-2) ICEA T-29-520 UL 1277 TC-LS rated
14 AWG & larger FT4/IEEE 1202/383
XLPE/Haloarrest 75°C 75°C UL 1685 TC-LS
(RFH-2) ICEA T-29-520 TC-ER Rated Cables
16 & 18 AWG FT4/IEEE 1202/383
As an option, Belden offers all PVC-nylon/
FEP/PVC 90°C 90°C UL 1685
PVC, XLPE/PVC and XLPE/CPE jacketed
CPE = Chlorinated Polyethylene • FEP = Fluorinated Ethylene-propylene • FRPO = Flame-retardant Polyolefin •
PVC = Polyvinyl Chloride • TPE = Thermoplastic Elastomer • XLPE = Cross-linked Polyethylene tray cables with a TC-ER (Exposed Run)
*Applicable to TC-rated cables only. rating, formerly referred to as Open Wiring.
Per NEC Article 336, a TC-ER rated cable
may be installed in an industrial establishment
Construction The Beldfoil® shield with drain wire between a cable tray and the utilization
provides 100% coverage for maximum equipment or device. A TC-ER rated cable
Soft annealed bare or tinned copper shield effectiveness. Copper tape shield must meet the crush and impact require-
conductors. PVC insulated with a available upon request. ments of UL Type MC cable. By eliminating
nylon overcoat, 90°C PVC Jacket, TFN,
the need for metal conduit and/or armor,
TFFN or THHN style singles. Nylon Individually Shielded using a TC-ER rated cable results in
rip cord included in all PVC-Nylon/PVC and Overall Shielded savings in both installation and maintenance.
instrumentation cables.
Individually shielded pairs or triads with
an overall shield are recommended for MC Cable Ratings Optional
Application
use in instrumentation applications where Customize any 600V TC instrumentation
These cables are suitable for installation optimum noise rejection is required. Individual cable, with armor and a full-sized ground.
in wet or dry locations. Cable jackets are pair/triad shields are fully isolated from See chart below to specify.
resistant to sunlight, moisture and vapor each other and contain a separate drain
penetration. The cables can be used in wire for grounding, to provide maximum To Specify MC Rated Cable
raceways, and (supported by messenger protection from crosstalk and common
mode interference. Cables with an overall 1 2 3456 A
wire), outdoor applications and direct Overall Armor Core Conductor,
burial applications. shield provide additional electrostatic Jacket Type 4-digit Insulation,
Type Part No. Inner Jacket
noise protection. 600V TC Type
Instrumentation
Unshielded
Twisted non-shielded instrument pairs Conductor, Insulation and Jacket Options* Overall Jacket Armor
provide a minimal OD allowing greater tray To Specify: Bare Tinned Insulation/Jacket Code Material Code Material
and conduit fill. Non-shielded instrument A B PVC-Nylon/PVC 1 PVC 2 Aluminum Interlock
pairs may be utilized when recommended 1234 A
Start Add or C D XLPE/PVC 3 CPE 3 Steel Interlock
by the instrument manufacturer and used with replace
Part letter E F FRPO/PVC 4 TPE
in a metallic conduit. No. code
G H XLPE/TPE 5 HDPE
K L TPE/TPE 6 Oil Res II
Overall Shield
M N PVC-Nylon/Oil Res II 7 Haloarrest
Recommended for use in instrumentation Q R XLPE/CPE
applications where signals are transmitted S T XLPE/Haloarrest Standard lengths may be subject to tolerance.
in excess of 100 millivolts except in areas *For 1000 and 3000 Series cables only.
Custom lengths may be available upon request.
Contact the Belden Electronics Division Customer
where high voltage and current sources
Service Department for additional information.
creates excessive noise interference.
1-800-BELDEN-1.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.57

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

18 AWG Pairs Stranded (19x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9486 1 E2 1000 304.8 43.0 19.5 .048 1.22 .275 6.99 50 222 2.75 69.85
ICEA S-73-532, ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9341 1 E2 500 152.4 22.0 10.0 .048 1.22 .276 7.01 63 280 2.75 69.85
ICEA S-73-532, ICEA S-61-402 1000 304.8 43.0 19.5
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

18 AWG Pairs Stranded (7x26) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 1120A 1 E2 10000 † 3048.0 450.0 204.3 .048 1.22 .278 7.06 59 262 2.80 71.12
ICEA S-73-532 Drain Wire
ICEA S-61-402 3088A 1 E1 10000 † 3048.0 510.0 231.3 .048 1.22 .278 7.06 67 298 2.80 71.12
ICEA T-29-520
FT4/IEEE 1202/383 1063A 2 E1 10000 † 3048.0 790.0 358.3 .053 1.35 .407 10.34 112 498 4.10 104.14
1064A 4 E1 7500 † 2286.0 892.5 404.8 .053 1.35 .470 11.94 202 899 4.70 119.38
1065A 8 E1 7500 † 2286.0 1650.0 748.4 .064 1.63 .599 15.21 381 1695 6.00 152.40
1066A 12 E1 5000 † 1524.0 1520.0 689.5 .064 1.63 .717 18.21 560 2491 7.20 182.88
1067A 16 E1 5000 † 1524.0 1905.0 864.1 .064 1.63 .793 20.14 739 3287 8.00 203.20
1068A 24 E1 2500 † 762.0 1487.5 674.7 .084 2.13 1.017 25.83 1098 4884 10.30 261.62
Rip Cord 1087A 36 E1 1250 † 381.0 1005.0 455.9 .084 2.13 1.178 29.97 1635 7273 11.70 297.18
1088A 50 E1 Bulk †† Bulk — — .084 2.13 1.446 36.73 2262 10062 14.50 368.30
Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below)
NEC: TC, NPLF 1048A 2 E1 7500 † 2286.0 622.5 282.4 .048 1.22 .381 9.68 140 623 3.80 96.52
ICEA S-73-532
ICEA S-61-402 1049A 4 E1 7500 † 2286.0 1057.5 479.7 .053 1.35 .489 12.42 258 1148 4.90 124.46
ICEA T-29-520
FT4/IEEE 1202/383 1050A 8 E1 7500 † 2286.0 1965.0 891.3 .064 1.63 .654 16.61 350 1557 6.60 167.64
1051A 12 E1 5000 † 1524.0 1915.0 868.6 .064 1.63 .785 19.94 728 3238 7.90 200.66
1052A 16 E1 2500 † 762.0 1267.5 574.9 .084 2.13 .898 22.81 963 4284 9.00 228.60
1053A 24 E1 2500 † 762.0 1907.5 865.2 .084 2.13 1.115 28.32 1434 6379 11.10 281.94
Rip Cord 1054A 36 E1 1250 † 381.0 1270.0 576.1 .084 2.13 1.299 32.99 2139 9515 13.00 330.20
Drain Wires
1038A 50 E1 Bulk †† Bulk — — .084 2.13 1.527 38.79 2962 13176 15.30 388.62
E1, E2 = Refer to Technical Information section for color code. Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


18 • Industrial Cables

To Specify: Bare Tinned Insulation/Jacket


A B PVC-Nylon/PVC
1234 A E
Start Add or Add for C D XLPE/PVC
with replace Exposed E F FRPO/PVC
Part letter code Run rating
No. for desired if desired G H XLPE/TPE
conductor,
insulation & jacket K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.58

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

18 AWG Pairs Stranded (7x26) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Green Ground)
NEC: TC-ER, NPLF 3088AE 1 E1 1000 3048.0 63.0 28.6 .048 1.22 .340 8.64 80 356 3.40 86.36
ICEA S-73-532 5000 † 1524.0 320.0 145.3
ICEA S-61-402 Ground
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

Overall Beldfoil Shield (100% Coverage) • XLPE Insulation • Black PVC Jacket (Green Ground)
NEC: TC-ER, NPLF 3088CE 1 E1 1000 3048.0 66.0 30.0 .048 1.22 .340 8.64 80 356 3.40 86.36
ICEA S-73-532 5000 † 1524.0 375.0 170.3
ICEA S-66-524 Ground
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

18 AWG Triads Stranded (7x26) Bare Copper Conductors • Twisted Triads


Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 1121A 1 E2 500 † 152.4 27.5 12.5 .048 1.22 .282 7.16 90 400 2.75 69.85
ICEA S-73-532 1000 † 304.8 53.0 24.0
ICEA S-61-402
ICEA T-29-520 10000 † 3048.0 560.0 254.0
FT4/IEEE 1202/383
3089A 1 E1 10000 † 3048.0 590.0 267.6 .048 1.22 .284 7.21 90 400 2.75 69.85

Rip Cord
Drain Wire

Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below)
NEC: TC, NPLF 3064A 2 E1 Bulk †† Bulk — — .048 1.22 .493 12.52 185 823 4.75 120.65
ICEA S-73-532
ICEA S-61-402 1093A 4 E1 7500 † 2286.0 1545.0 700.8 .063 1.60 .577 14.66 347 1544 6.00 152.40
ICEA T-29-520
FT4/IEEE 1202/383 1094A 8 E1 5000 † 1524.0 1755.0 796.1 .063 1.60 .745 18.92 672 2989 7.50 190.50
1095A 12 E1 2500 † 762.0 1320.0 598.8 .084 2.13 .944 23.98 997 4435 9.75 247.65
5000 † 1524.0 2875.0 1304.1
3066A 16 E1 Bulk †† Bulk — — .084 2.13 1.046 26.57 1322 5881 10.50 266.70
1096A 24 E1 Bulk †† Bulk — — .084 2.13 1.284 32.61 1971 8767 13.00 330.20
Rip Cord
Drain Wires

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC-Nylon/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating E F FRPO/PVC
No. for desired if desired
conductor, G H XLPE/TPE
insulation & jacket
K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.59

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Standard Jacket Nominal Maximum Minimum


Part No. Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Color
Description of
No. Code
Pairs Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

16 AWG Pairs Stranded (19x29) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9487 1 E2 500 152.4 25.5 11.6 .048 1.22 .295 7.49 70 311 3.00 76.20
ICEA S-73-532, ICEA S-61-402 1000 304.8 54.0 24.5
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9342 1 E2 500 152.4 27.5 12.7 .048 1.22 .296 7.52 105 467 3.00 76.20
ICEA S-73-532, ICEA S-61-402 1000 304.8 56.0 25.4
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

16 AWG Pairs Stranded (7x24) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 1118A 1 E2 10000 † 3048.0 550.0 249.5 .047 1.19 .294 7.47 105 467 3.00 76.20
ICEA S-73-532
ICEA S-61-402 Drain Wire 3090A 1 E1 2500 † 762.0 150.0 68.0 .047 1.19 .295 7.49 105 467 3.00 76.20
ICEA T-29-520
FT4/IEEE 1202/383 1069A 2 E1 7500 † 2286.0 712.5 323.2 .047 1.19 .456 11.58 179 796 4.60 116.84
1527A 3 E1 7500 † 2286.0 1042.5 472.9 .047 1.19 .482 12.24 241 1072 4.80 121.92
1070A 4 E1 7500 † 2286.0 1357.5 615.8 .063 1.60 .560 14.22 321 1428 5.60 142.24
1071A 8 E1 7500 † 2286.0 2242.5 1017.2 .063 1.60 .676 17.17 607 2700 6.80 172.72
1072A 12 E1 5000 † 1524.0 1047.5 475.2 .063 1.60 .812 20.63 893 3972 8.10 205.74
1073A 16 E1 2500 † 762.0 1442.5 654.3 .085 2.16 .946 24.03 1178 5240 9.30 236.22
1074A 24 E1 1250 † 381.0 2115.0 959.4 .085 2.16 1.158 29.41 1749 7780 11.60 294.64
Rip Cord 1089A 36 E1 1250 † 381.0 1388.7 629.9 .085 2.16 1.321 33.55 2606 11592 13.20 335.28
1090A 50 E1 Bulk †† Bulk — — .085 2.16 1.551 39.40 3606 16040 15.50 393.70
Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below)
NEC: TC, NPLF 1055A 2 E1 7500 † 2286.0 885.0 401.8 .047 1.19 .476 12.09 223 992 4.16 105.66
ICEA S-73-532
ICEA S-61-402 1037A 3 E1 7500 † 2286.0 1072.5 486.5 .047 1.19 .504 12.80 290 1290 5.00 127.0
ICEA T-29-520
FT4/IEEE 1202/383 1039A 4 E1 7500 † 2286.0 1472.5 667.9 .063 1.60 .584 14.83 411 1828 5.80 147.32
1040A 6 E1 5000 † 1524.0 1435.0 650.9 .063 1.60 .682 17.32 428 1904 6.80 172.72
1041A 8 E1 5000 † 1524.0 1805.0 818.8 .063 1.60 .738 18.75 786 3496 7.40 187.96
1042A 12 E1 2500 † 762.0 1327.5 602.2 .085 2.16 .935 23.75 1161 5164 9.40 238.76
Rip Cord 1043A 16 E1 2500 † 762.0 1765.0 800.6 .085 2.16 1.035 26.29 1537 6837 10.40 264.16
Drain Wires 1044A 20 E1 2500 † 762.0 2062.5 935.6 .085 2.16 1.146 29.11 1912 8505 11.50 292.10
1045A 24 E1 1250 † 381.0 1241.3 563.1 .085 2.16 1.272 32.31 2287 10173 12.70 322.58
1046A 36 E1 Bulk †† Bulk — — .085 2.16 1.454 36.93 3413 15182 14.50 368.30
1047A 50 E1 Bulk †† Bulk — — .120 3.05 1.781 45.24 4726 21022 17.80 452.12
E1, E2 = Refer to Technical Information section for color code.
Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction. Conductor, Insulation and Jacket Options**
18 • Industrial Cables

To Specify: Bare Tinned Insulation/Jacket


A B PVC-Nylon/PVC
1234 A E
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating E F FRPO/PVC
No. for desired if desired G H XLPE/TPE
conductor,
insulation & jacket K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.60

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

16 AWG Pairs Stranded (7x24) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Green Ground)
NEC: TC-ER, NPLF 3090AE 1 E1 1000 304.8 65.0 29.5 .048 1.22 .390 9.91 130 578 3.90 99.06
ICEA S-73-532 5000 † 1524.0 340.0 154.4
ICEA S-61-402 Ground
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

Overall Beldfoil Shield (100% Coverage) • XLPE Insulation • Black PVC Jacket (Green Ground)
NEC: TC-ER, NPLF 3090CE 1 E1 1000 3048.0 81.0 39.8 .048 1.22 .390 9.91 130 578 3.90 99.06
ICEA S-73-532 5000 † 1524.0 450.0 204.3
ICEA S-66-524 Ground
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

16 AWG Triads Stranded (7x24) Bare Copper Conductors • Twisted Triads


Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 1119A 1 E2 500 † 152.4 35.0 15.9 .047 1.19 .310 7.87 129 574 3.10 78.74
ICEA S-73-532 1000 † 304.8 68.0 30.9
ICEA S-61-402
ICEA T-29-520 10000 † 3048.0 700.0 317.5
FT4/IEEE 1202/383
3091A 1 E1 10000 † 3048.0 750.0 340.2 .047 1.19 .310 7.87 129 574 3.10 78.74

Rip Cord
Drain Wire

Individually Shielded + Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (Options below)
NEC: TC, NPLF 1097A 4 E1 5000 † 1524.0 1415.0 641.8 .063 1.60 .640 16.26 554 2464 6.40 162.56
ICEA S-73-532
ICEA S-61-402 1098A 8 E1 2500 † 762.0 1350.0 612.4 .085 2.16 .872 22.15 1072 4768 8.70 220.98
ICEA T-29-520
FT4/IEEE 1202/383 1099A 12 E1 2500 † 762.0 1875.0 850.5 .085 2.16 1.047 26.59 1590 7073 10.50 266.70
3118A 16 E1 Bulk †† Bulk — — .084 2.13 1.234 31.34 1771 7878 12.25 311.15
1100A 24 E1 Bulk †† Bulk — — .085 2.16 1.434 36.42 3144 13985 14.30 363.22
3130A 36 E1 Bulk †† Bulk — — .110 2.79 1.773 45.03 3600 16013 18.00 457.20

Rip Cord
Drain Wires

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
Multiple pair or triad cables have each pair/triad numbered for ease of identification.

Final put-up length may vary ±10% from length shown.
††
Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC-Nylon/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating E F FRPO/PVC
No. for desired if desired
conductor, G H XLPE/TPE
insulation & jacket
K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.61

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

14 AWG Pairs Stranded (42x30) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9488 1 E2 1000 304.8 77.0 34.9 .048 1.22 .359 9.12 107 476 3.75 95.25
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9343 1 E2 500 152.4 42.5 19.1 .048 1.22 .358 9.09 160 712 3.75 95.25
ICEA S-73-532 1000 304.8 86.0 39.0
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

14 AWG Pairs Stranded (7x22) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 3080A 1 E1 Bulk* Bulk* — — .048 1.22 .342 8.69 160 712 3.50 88.90
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

14 AWG Triads Stranded (7x22) Bare Copper Conductors • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 3081A 1 E1 Bulk* Bulk* — — .048 1.22 .361 9.17 200 890 3.50 88.90
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
*Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
18 • Industrial Cables

1234 A E A B PVC-Nylon/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating E F FRPO/PVC
No. for desired if desired
conductor, G H XLPE/TPE
insulation & jacket
K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.62

UL Instrumentation Cable
600V Tray Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

No. Standard Standard Jacket Nominal Maximum Minimum


Part of Color Lengths Unit Weight Thickness OD Pull Tension Bend Radius
Description Pairs/
No. Code
Triads Ft. m Lbs. kg Inch mm Inch mm Lbs. N Inch mm

12 AWG Pairs Stranded (37x27) Tinned Copper Conductors • Twisted Pairs


Unshielded • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9489 1 E2 1000 304.8 88.0 39.9 .045 1.14 .380 9.65 170 756 3.75 95.25
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord

Overall Beldfoil® Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket
NEC: TC, NPLF 9344 1 E2 500 152.4 54.0 24.5 .045 1.14 .384 9.75 253 1125 3.75 95.25
ICEA S-73-532 1000 304.8 111.0 50.4
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

12 AWG Pairs Stranded (7x20) Bare Copper Conductors • Twisted Pairs


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 3103A 1 E1 Bulk* Bulk* — — .048 1.22 .380 9.65 253 1125 3.80 96.52
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

12 AWG Triads Stranded (7x20) Bare Copper Conductors • Twisted Triads


Overall Beldfoil Shield (100% Coverage) • PVC/Nylon Insulation • Black PVC Jacket (See chart below for other options)
NEC: TC, NPLF 3104A 1 E1 Bulk* Bulk* — — .048 1.22 .401 10.19 315 1401 4.00 101.60
ICEA S-73-532
ICEA S-61-402
ICEA T-29-520
FT4/IEEE 1202/383

Rip Cord
Drain Wire

E1, E2 = Refer to Technical Information section for color code.


Alternate color coding available upon request.
*Bulk = Check length available for specific construction.

Conductor, Insulation and Jacket Options**


To Specify: Bare Tinned Insulation/Jacket
1234 A E A B PVC-Nylon/PVC
Start Add or Add for C D XLPE/PVC
with replace Exposed
Part letter code Run rating E F FRPO/PVC
No. for desired if desired
conductor, G H XLPE/TPE
insulation & jacket
K L TPE/TPE
M N PVC-Nylon/Oil Res II
Q R XLPE/CPE
S T XLPE/Haloarrest®
**For 1000 and 3000 Series cables only.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.63

UL Control Cable
600V Type TC Cables — Overview

Introduction Tray Cable Construction Options

Belden offers a wide selection of UL-rated UL Listed for MC and TC


600V Tray Cable for a variety of control Max. Temp Rating
applications. Insulation/Jacket Flame Tests Ratings*
Wet Dry
Multi-conductor versions are available as PVC-Nylon/PVC 75°C 90°C UL 1685 ICEA S-73-532
standards from 18 to 1 AWG. 1/0 through (THHN or THWN) FT4/IEEE 1202/383 ICEA S-95-658
14 AWG & larger ICEA T-29-520 ICEA S-61-402
4/0 are also available as custom made
PVC-Nylon/PVC NA 90°C UL 1685 ICEA S-73-532
constructions. These are unshielded and (TFN or TFFN) FT4/IEEE 1202/383 ICEA S-95-658
shielded versions that come with various 16 & 18 AWG ICEA T-29-520 ICEA S-61-402
insulation and jacket combinations. XLPE/PVC or CPE 90°C 90°C UL 1685 ICEA S-73-532
(XHHW–2) FT4/IEEE 1202/383 ICEA S-95-658
These TC cables are installed in cable 14 AWG & larger VW-1 rated singles ICEA S-66-524
trays, ducts and conduit and can be used ICEA T-29-520
in direct burial applications. They are XLPE/PVC or CPE 75°C 75°C UL 1685 ICEA S-73-532
(RFH–2) FT4/IEEE 1202/383 ICEA S-95-658
extensively used in manufacturing facilities, 16 & 18 AWG VW-1 rated singles ICEA S-66-524
especially in the process industries such ICEA T-29-520
as petrochemical, steel, pulp and paper, FRPO/PVC — 75°C UL 1685
18 AWG & larger
cement and mining.
TPE/TPE 75°C 90°C UL 1685
These flexible, space efficient cables FRPO/PVC 75°C 90°C UL 1685
can be substantially more economical XLPE/Haloarrest® 90°C 90°C UL 1685 TC-LS
than traditional wiring methods. (XHHW-2) 14 AWG & larger FT4/IEEE 1202/383
ICEA T-29-520
XLPE/Haloarrest 75°C 75°C UL 1685 TC-LS
(RFH-2) 16 & 18 AWG FT4/IEEE 1202/383
Construction ICEA T-29-520
Soft annealed bare or tinned copper FEP/PVC 90°C 90°C UL 1685
CPE = Chlorinated Polyethylene • FEP = Fluorinated Ethylene-propylene • FRPO = Flame-retardant Polyolefin •
conductors, with various insulation and PVC = Polyvinyl Chloride • TPE = Thermoplastic Elastomer • XLPE = Cross-linked Polyethylene
jacketing options as seen in chart below. *Applicable to TC-rated cables only.

Ground Wire ● Approved for cable tray use in Class 1,


Application
● Non-insulated, bare copper ground Division 2 areas, per NEC Articles 340,
These cables are suitable for installation wires are included for constructions 318 and 501, and for Class 1 circuits
in wet or dry locations. Cable jackets are 8 through 1 AWG. Non-insulated, bare as permitted in Article 725
resistant to sunlight, moisture and vapor copper, full sized ground wires may ● PVC-Nylon/PVC, XLPE/PVC and
penetration. The cables can be used in be requested on other constructions. XLPE/CPE constructed cables meet
raceways (supported by messenger wire), ● IEEE 1202/IEEE 383-2003/FT4
All shielded PVC-Nylon/PVC constructions
outdoor applications and direct burial (70,000 BTU/hr) Flame Test
include full sized ground (drain) wires.
applications.

Unshielded Color Code TC-ER Rated Cables

Cabled non-shielded conductors provide Multi-conductor control cables (10 AWG As an option, Belden offers all PVC-nylon/
a minimal O.D. allowing greater tray and to 18 AWG) are printed alpha-numerically PVC, XLPE/PVC and XLPE/CPE jacketed
conduit fill. Non-shielded control cable may in addition to being color coded per ICEA tray cables with a TC-ER (Exposed Run)
be utilized when recommended by the Table E2. rating, formerly referred to as Open Wiring.
equipment manufacturer and used in a Per NEC Article 336, a TC-ER rated cable
8 AWG and larger are black and numbered
metallic conduit. may be installed in an industrial establishment
per ICEA Method 4.
between a cable tray and the utilization
Overall Shield Refer to Technical Information Section equipment or device. A TC-ER rated cable
Recommended for use in control applications for ICEA color code charts. must meet the crush and impact require-
where signals are transmitted in excess of ments of UL Type MC cable. By eliminating
100 millivolts, except in areas where high Specifications the need for metal conduit and/or armor,
voltage and current sources create exces- using a TC-ER rated cable results in
● UL Subject 1277 Type TC savings in both installation and maintenance.
sive noise interference. The Beldfoil® shield
18 • Industrial Cables

with drain wire provides 100% coverage for ● XLPE/Haloarrest jacketed cables Standard lengths may be subject to
maximum shield effectiveness. Copper tape are UL 1277 TC-LS rated tolerance. Custom lengths may be
shield available upon request. available upon request. Contact the Belden
● UL Subject 1424 (per outline for NPLF
Only 2-conductor round constructions requirements dated May 3, 1979) Electronics Division Customer Service
can be shielded. Flat constructions Department for additional information.
● UL 1685 (UL 1581) Vertical Flame Test
cannot be shielded. 1-800-BELDEN-1
comparable to IEEE 383-1974 (70,000
BTU/hr) Flame Test

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.64

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

18 AWG Multi-conductor Stranded (7x26) Bare Copper Conductors


PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27916A† 2 E2 Bulk Bulk 33.0 49.1 .045 1.14 .180 4.57 44 195.8 2.7 68.58
FT4/IEEE 1202/383 x x
ICEA S-73-532
ICEA S-95-658 .266 6.76
ICEA S-61-402
ICEA T-29-520 27325A†† 2 E2 Bulk Bulk 34.0 50.6 .045 1.14 .270 6.86 44 195.8 2.7 68.58
27334A 3 E2 Bulk Bulk 45.0 67.0 .045 1.14 .280 7.11 66 293.7 2.8 71.12
27326A 4 E2 Bulk Bulk 52.0 77.4 .045 1.14 .310 7.87 88 391.6 3.1 78.74
27335A 5 E2 Bulk Bulk 62.0 92.3 .045 1.14 .330 8.38 110 489.5 3.3 83.82
27600A 6 E2 Bulk Bulk 72.0 107.2 .045 1.14 .350 8.89 132 587.4 3.5 88.90
Rip Cord 27327A 7 E2 Bulk Bulk 79.0 117.6 .045 1.14 .350 8.89 154 685.3 3.5 88.90
27601A 8 E2 Bulk Bulk 89.0 132.5 .045 1.14 .390 9.83 176 783.2 3.8 96.52
27336A 9 E2 Bulk Bulk 104.0 154.8 .045 1.14 .410 10.41 198 881.1 4.1 104.14
27328A 10 E2 Bulk Bulk 111.0 165.2 .060 1.52 .450 11.43 220 979.0 4.5 114.30
27602A 11 E2 Bulk Bulk — — .060 1.52 .450 11.43 242 1076.9 4.5 114.30
27329A 12 E2 Bulk Bulk 127.0 189.0 .060 1.52 .450 11.43 264 1174.8 4.5 114.30
27603A 13 E2 Bulk Bulk 142.0 211.3 .060 1.52 .470 11.94 286 1272.7 4.7 119.38
27604A 14 E2 Bulk Bulk — — .060 1.52 .480 12.19 308 1370.6 4.8 121.92
27605A 15 E2 Bulk Bulk 175.0 260.4 .060 1.52 .510 12.95 330 1468.5 5.1 129.54
27606A 16 E2 Bulk Bulk 167.0 248.5 .060 1.52 .500 12.70 352 1566.4 5.0 127.00
27607A 17 E2 Bulk Bulk — — .060 1.52 .570 14.48 374 1664.3 5.7 144.78
27608A 18 E2 Bulk Bulk 196.0 291.7 .060 1.52 .570 14.48 396 1762.2 5.7 144.78
27609A 19 E2 Bulk Bulk 202.0 300.6 .060 1.52 .570 14.48 418 1860.1 5.7 144.78
27610A 20 E2 Bulk Bulk 214.0 318.5 .060 1.52 .600 15.24 440 1958.0 5.9 149.86
27611A 25 E2 Bulk Bulk 258.0 384.0 .060 1.52 .660 16.76 550 2447.5 6.6 167.64
27612A 30 E2 Bulk Bulk 300.0 446.5 .060 1.52 .690 17.53 660 2937.0 6.6 167.64
27613A 37 E2 Bulk Bulk 360.0 535.8 .080 2.03 .740 18.80 814 3622.3 7.4 187.96
27614A 50 E2 Bulk Bulk 511.0 760.5 .080 2.03 .910 23.11 1100 4895.0 9.1 231.14
27632A 60 E2 Bulk Bulk 627.0 933.1 .080 2.03 .960 24.38 1320 5874.0 9.6 243.84

18 AWG Multi-conductor Stranded (7x26) Bare Copper Conductors • Overall Beldfoil® Shield (100% Coverage) with Drain Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27325AS 2 E2 Bulk Bulk 34.0 50.6 .045 1.14 .270 6.86 67 298 2.70 68.58
FT4/IEEE 1202/383
ICEA S-73-532 27334AS 3 E2 Bulk Bulk 45.0 67.0 .045 1.14 .280 7.11 90 400 2.80 71.12
ICEA S-95-658
ICEA S-61-402 27326AS 4 E2 Bulk Bulk 60.0 89.3 .045 1.14 .300 7.62 112 498 3.10 81.28
ICEA T-29-520

Rip Cord
Drain Wire

E2 = Refer to Technical Information section for color code.


† Flat construction; overall shield not available.
†† Twisted Conductors.

Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction.
Conductor, Insulation and Jacket Options
To Specify: Bare Tinned Insulation/Jacket
12345 A S A B PVC-Nylon/PVC
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil
No. type Shield G H XLPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply K L TPE/TPE
replace the second digit of the part number from a 7 to an 8. M N PVC-Nylon/Oil Res II
For example: 27080A with TC-ER rating becomes 28080A. Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.65

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

16 AWG Multi-conductor Stranded (7x24) Bare Copper Conductors


PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27917A† 2 E2 Bulk Bulk 42.0 62.5 .045 1.14 .190 4.83 70 312 2.9 73.66
FT4/IEEE 1202/383 x x
ICEA S-73-532
ICEA S-95-658
.290 7.37
ICEA S-61-402 27337A†† 2 E2 Bulk Bulk 45.0 67.0 .045 1.14 .299 7.60 70 312 2.9 73.66
ICEA T-29-520
27331A 3 E2 Bulk Bulk 55.0 81.9 .045 1.14 .307 7.80 105 467 3.1 78.74
27338A 4 E2 Bulk Bulk 69.0 102.7 .045 1.14 .332 8.18 140 623 3.3 83.82
27339A 5 E2 Bulk Bulk 83.0 123.5 .045 1.14 .360 9.14 175 779 3.6 91.44
27615A 6 E2 Bulk Bulk 96.0 142.9 .045 1.14 .390 9.91 210 935 3.9 99.06
Rip Cord 27323A 7 E2 Bulk Bulk 106.0 157.7 .045 1.14 .390 9.91 245 1090 3.9 99.06
27616A 8 E2 Bulk Bulk 122.0 181.6 .045 1.14 .420 10.67 280 1246 4.2 106.68
27340A 9 E2 Bulk Bulk 138.0 200.4 .045 1.14 .450 11.43 315 1402 4.5 114.30
27617A 10 E2 Bulk Bulk 149.0 221.7 .045 1.14 .490 12.45 350 1558 4.9 124.46
27618A 11 E2 Bulk Bulk 161.0 239.6 .045 1.14 .490 12.45 385 1713 4.9 124.46
27341A 12 E2 Bulk Bulk 174.0 258.9 .045 1.14 .500 12.70 420 1869 5.0 127.00
27619A 13 E2 Bulk Bulk 203.0 302.1 .045 1.14 .570 14.48 455 2025 5.7 144.78
27620A 14 E2 Bulk Bulk 223.0 331.8 .045 1.14 .570 14.48 490 2181 5.7 144.78
27621A 15 E2 Bulk Bulk 229.0 340.8 .060 1.52 .590 14.99 525 2336 5.9 149.86
27330A 16 E2 Bulk Bulk 241.0 358.7 .045 1.14 .600 15.24 560 2492 6.0 152.40
27622A 17 E2 Bulk Bulk 267.0 397.3 .060 1.52 .630 16.00 595 2648 6.3 160.02
27623A 18 E2 Bulk Bulk — — .060 1.52 .630 16.00 630 2804 6.3 160.02
27624A 19 E2 Bulk Bulk 287.0 427.1 .060 1.52 .630 16.00 665 2959 6.3 160.02
27625A 20 E2 Bulk Bulk 304.0 452.4 .060 1.52 .660 16.76 700 3115 6.6 167.64
27324A 25 E2 Bulk Bulk 367.0 546.1 .080 2.03 .730 18.54 875 3894 7.3 185.42
27626A 30 E2 Bulk Bulk 428.0 636.9 .080 2.03 .770 19.56 1050 4673 7.7 195.58
27627A 37 E2 Bulk Bulk 514.0 764.8 .080 2.03 .830 21.08 1295 5763 8.3 210.82
27628A 50 E2 Bulk Bulk 723.0 1075.8 .080 2.03 1.000 25.40 1750 7788 10.0 254.00
27633A 60 E2 Bulk Bulk 844.0 1255.9 .080 2.03 1.100 27.94 2100 9345 11.0 279.40

16 AWG Multi-conductor Stranded (7x24) Bare Copper Conductors • Overall Beldfoil® Shield (100% Coverage) with Drain Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27337AS 2 E2 Bulk Bulk 45.0 67.0 .045 1.14 .302 7.67 94 418 3.00 76.20
FT4/IEEE 1202/383
ICEA S-73-532
27331AS 3 E2 Bulk Bulk 55.0 81.8 .045 1.14 .320 8.13 130 578 3.20 81.28
ICEA S-95-658
ICEA S-61-402
ICEA T-29-520

Rip Cord
Drain Wire

E2 = Refer to Technical Information section for color code.


† Flat construction; overall shield not available.
†† Twisted Conductors.

Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction. Conductor, Insulation and Jacket Options
To Specify: Bare Tinned Insulation/Jacket
18 • Industrial Cables

12345 A S A B PVC-Nylon/PVC
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil
No. type Shield G H XLPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply K L TPE/TPE
replace the second digit of the part number from a 7 to an 8. M N PVC-Nylon/Oil Res II
For example: 27080A with TC-ER rating becomes 28080A. Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.66

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

14 AWG Multi-conductor Stranded (7x22) Bare Copper Conductors


PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27080A† 2 E2 1000 304.8 61.0 27.7 .045 1.14 .210 5.33 108 481 3.5 88.90
FT4/IEEE 1202/383 Bulk Bulk 61.0 27.7 x x
ICEA S-73-532 .320 8.13
ICEA S-95-658
ICEA S-61-402 27636A†† 2 E2 Bulk Bulk 62.0 92.3 .045 1.14 .320 8.13 108 481 3.2 81.28
ICEA T-29-520 27081A 3 E2 1000 304.8 86.0 39.0 .045 1.14 .340 8.64 162 721 3.4 86.36
Bulk Bulk 86.0 39.0
27082A 4 E2 1000 304.8 110.0 49.9 .045 1.14 .360 9.14 216 961 3.6 91.44
Bulk Bulk 110.0 49.9
27083A 5 E2 Bulk Bulk 118.0 175.6 .045 1.14 .400 10.16 270 1202 3.9 99.06
27084A 6 E2 Bulk Bulk 140.0 208.3 .045 1.14 .434 11.02 324 1442 4.3 109.22
Rip Cord
27085A 7 E2 Bulk Bulk 153.0 227.7 .045 1.14 .433 11.00 378 1682 4.3 109.22
27086A 8 E2 Bulk Bulk 173.0 257.5 .045 1.14 .480 12.19 432 1922 4.7 119.38
27087A 9 E2 Bulk Bulk 196.0 291.7 .045 1.14 .510 12.95 486 2163 5.1 129.54
27088A 10 E2 Bulk Bulk 230.0 342.3 .060 1.52 .588 14.94 540 2403 5.7 144.78
27089A 11 E2 Bulk Bulk 251.0 373.6 .060 1.52 .595 15.11 594 2643 5.9 149.86
27090A 12 E2 Bulk Bulk 270.0 401.8 .060 1.52 .595 15.11 648 2884 5.9 149.86
27091A 13 E2 Bulk Bulk — — .060 1.52 .640 16.26 702 3124 6.3 160.02
27092A 14 E2 Bulk Bulk 308.0 458.3 .060 1.52 .640 16.26 756 3364 6.3 160.02
27093A 15 E2 Bulk Bulk 330.0 491.1 .060 1.52 .670 17.02 810 3605 6.7 170.18
27094A 16 E2 Bulk Bulk 343.0 510.5 .060 1.52 .671 17.04 864 3845 6.6 167.64
27095A 17 E2 Bulk Bulk — — .060 1.52 .700 17.78 918 4085 7.0 177.80
27096A 18 E2 Bulk Bulk — — .060 1.52 .700 17.78 972 4325 7.0 177.80
27097A 19 E2 Bulk Bulk 396.0 589.3 .060 1.52 .705 17.91 1026 4566 7.0 177.80
27098A 20 E2 Bulk Bulk 425.0 632.5 .060 1.52 .735 18.67 1080 4806 7.4 187.96
27099A 21 E2 Bulk Bulk 438.0 651.7 .060 1.52 .740 18.80 1134 5046 7.4 187.96
27100A 22 E2 Bulk Bulk — — .060 1.52 .760 19.30 1188 5287 7.6 193.04
27101A 23 E2 Bulk Bulk — — .060 1.52 .760 19.30 1242 5527 7.6 193.04
27102A 24 E2 Bulk Bulk 495.0 736.7 .060 1.52 .810 20.57 1296 5767 8.1 205.74
27103A 25 E2 Bulk Bulk 560.0 833.4 .060 1.52 .810 20.57 1350 6008 8.1 205.74
27104A 26 E2 Bulk Bulk — — .060 1.52 .810 20.57 1404 6248 8.1 205.74
27105A 27 E2 Bulk Bulk 587.0 873.5 .080 2.03 .870 22.10 1458 6488 8.7 220.98
27106A 28 E2 Bulk Bulk — — .080 2.03 .910 23.11 1512 6728 9.1 231.14
27107A 29 E2 Bulk Bulk 680.0 1012.0 .080 2.03 .910 23.11 1566 6969 9.1 231.14
27108A 30 E2 Bulk Bulk 639.0 950.8 .080 2.03 .902 22.91 1620 7209 9.0 228.60
27629A 37 E2 Bulk Bulk 768.0 1142.9 .080 2.03 .975 24.77 1998 8891 9.7 246.38
27912A 50 E2 Bulk Bulk 1080.0 1607.3 .080 2.03 1.138 28.91 2700 12015 11.3 287.02

14 AWG Multi-conductor Stranded (7x22) Bare Copper Conductors • Overall Beldfoil® Shield (100% Coverage) with Drain Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27081AS 3 E2 Bulk Bulk 80.0 119.1 .045 1.14 .340 8.64 99 440 3.4 86.36
FT4/IEEE 1202/383
ICEA S-73-532, ICEA S-95-658 27082AS 4 E2 Bulk Bulk 105.0 156.3 .045 1.14 .391 9.93 273 1214 3.9 99.06
ICEA S-61-402,
ICEA T-29-520

Rip Cord
Drain Wire

E2 = Refer to Technical Information section for color code.


† Flat construction; overall Conductor, Insulation and Jacket Options
shield not available.
†† Twisted Conductors.
To Specify: Bare Tinned Insulation/Jacket
Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction. A B PVC-Nylon/PVC
12345 A S
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil G H XLPE/TPE
No. type Shield
K L TPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply M N PVC-Nylon/Oil Res II
replace the second digit of the part number from a 7 to an 8. Q R XLPE/CPE
For example: 27080A with TC-ER rating becomes 28080A.
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.67

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

12 AWG Multi-conductor Stranded (7x20) Bare Copper Conductors


PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27109A† 2 E2 1000 304.8 74.0 110.0 .045 1.14 .220 5.59 172 765 3.5 88.90
FT4/IEEE 1202/383 Bulk Bulk 74.0 110.0 x x
ICEA S-73-532 .350 8.89
ICEA S-95-658
ICEA S-61-402 27641A†† 2 E2 Bulk Bulk 86.0 128.0 .045 1.14 .360 9.14 172 765 3.6 91.44
ICEA T-29-520
27110A 3 E2 1000 304.8 110.0 163.7 .045 1.14 .374 9.50 258 1148 3.7 93.98
Bulk Bulk 110.0 163.7
27111A 4 E2 1000 304.8 134.0 199.0 .045 1.14 .410 10.41 344 1531 4.1 104.14
Bulk Bulk 134.0 199.0
27112A 5 E2 Bulk Bulk 165.0 245.6 .045 1.14 .450 11.43 430 1914 4.5 114.30
Rip Cord
27113A 6 E2 Bulk Bulk 197.0 293.2 .045 1.14 .480 12.19 516 2296 4.8 121.92
27114A 7 E2 Bulk Bulk 216.0 321.5 .045 1.14 .480 12.19 602 2679 4.8 121.92
27115A 8 E2 Bulk Bulk 263.0 391.4 .060 1.52 .560 14.22 688 3062 5.6 142.24
27116A 9 E2 Bulk Bulk 297.0 442.0 .060 1.52 .600 15.24 774 3444 6.0 152.40
27117A 10 E2 Bulk Bulk 324.0 482.2 .060 1.52 .660 16.76 860 3827 6.6 167.64
27118A 11 E2 Bulk Bulk — — .060 1.52 .670 17.02 946 4210 6.7 170.18
27119A 12 E2 Bulk Bulk 378.0 562.5 .060 1.52 .670 17.02 1032 4592 6.7 170.18
27120A 13 E2 Bulk Bulk — — .060 1.52 .700 17.78 1118 4975 7.0 177.80
27121A 14 E2 Bulk Bulk — — .060 1.52 .700 17.78 1204 5358 7.0 177.80
27122A 15 E2 Bulk Bulk 468.0 696.5 .060 1.52 .740 18.80 1290 5741 7.4 187.96
27123A 16 E2 Bulk Bulk 490.0 729.2 .060 1.52 .750 19.05 1376 6123 7.5 190.50
27124A 17 E2 Bulk Bulk — — .060 1.52 .770 19.56 1462 6506 7.7 195.58
27125A 18 E2 Bulk Bulk — — .060 1.52 .770 19.56 1548 6889 7.7 195.58
27126A 19 E2 Bulk Bulk 568.0 845.3 .060 1.52 .790 20.07 1634 7271 7.9 200.66
27127A 20 E2 Bulk Bulk 640.0 952.4 .080 2.03 .870 22.10 1720 7654 8.7 220.98
27128A 21 E2 Bulk Bulk — — .080 2.03 .870 22.10 1806 8037 8.7 220.98
27129A 22 E2 Bulk Bulk — — .080 2.03 .890 22.61 1892 8419 8.9 226.06
27130A 23 E2 Bulk Bulk — — .080 2.03 .890 22.61 1978 8802 8.9 226.06
27131A 24 E2 Bulk Bulk — — .080 2.03 .940 23.88 2064 9185 9.4 238.76
27132A 25 E2 Bulk Bulk 775.0 1153.4 .080 2.03 .960 24.38 2150 9568 9.6 243.84
27133A 26 E2 Bulk Bulk — — .080 2.03 .960 24.38 2236 9950 9.6 243.84
27134A 27 E2 Bulk Bulk 828.0 1232.2 .080 2.03 .960 24.38 2322 10333 9.6 243.84
27135A 28 E2 Bulk Bulk — — .080 2.03 .990 25.15 2408 10716 9.9 251.46
27136A 29 E2 Bulk Bulk — — .080 2.03 .990 25.15 2494 11098 9.9 251.46
27137A 30 E2 Bulk Bulk 910.0 1354.3 .080 2.03 1.020 25.91 2580 11481 10.2 259.08
27630A 37 E2 Bulk Bulk 1100.0 1637.0 .080 2.03 1.090 27.69 3182 14160 10.9 276.86
27634A 50 E2 Bulk Bulk 1450.0 2157.9 .080 2.03 1.300 33.02 4300 19135 13.0 330.20
E2 = Refer to Technical Information section for color code.
† Flat construction; overall shield not available.
†† Twisted Conductors.

Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction.

Conductor, Insulation and Jacket Options


To Specify: Bare Tinned Insulation/Jacket
18 • Industrial Cables

12345 A S A B PVC-Nylon/PVC
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil®
No. type Shield G H XLPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply K L TPE/TPE
replace the second digit of the part number from a 7 to an 8. M N PVC-Nylon/Oil Res II
For example: 27080A with TC-ER rating becomes 28080A. Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.68

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

10 AWG Multi-conductor Stranded (7x18) Bare Copper Conductors


PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27138A† 2 E2 Bulk Bulk 83.0 123.5 .045 1.14 .260 6.60 296 1317 4.2 106.68
FT4/IEEE 1202/383 x x
ICEA S-73-532 .420 10.67
ICEA S-95-658
ICEA S-61-402 27643A†† 2 E2 Bulk Bulk 131.0 195.0 .045 1.14 .420 10.67 296 1317 4.2 106.68
ICEA T-29-520
27139A 3 E2 1000 304.8 164.0 244.0 .045 1.14 .450 11.43 444 1976 4.5 114.30
Bulk Bulk 164.0 244.0
27140A 4 E2 1000 304.8 216.0 321.0 .045 1.14 .490 12.45 592 2634 4.9 124.46
Bulk Bulk 216.0 321.0
27141A 5 E2 Bulk Bulk 276.0 410.7 .060 1.52 .570 14.48 740 3293 5.7 144.78
Rip Cord
27142A 6 E2 Bulk Bulk 329.0 489.6 .060 1.52 .620 15.75 888 3952 6.2 157.48
27143A 7 E2 Bulk Bulk 361.0 537.2 .060 1.52 .620 15.75 1036 4610 6.2 157.48
27144A 8 E2 Bulk Bulk 411.0 611.7 .060 1.52 .680 17.27 1184 5269 6.8 172.72
27145A 9 E2 Bulk Bulk 465.0 692.0 .060 1.52 .720 18.29 1332 5927 7.2 182.88
27146A 10 E2 Bulk Bulk 542.0 806.6 .060 1.52 .790 20.07 1480 6586 7.9 200.66
27147A 11 E2 Bulk Bulk 582.0 866.0 .060 1.52 .790 20.07 1628 7245 7.9 200.66
27148A 12 E2 Bulk Bulk 620.0 922.7 .080 2.03 .820 20.83 1776 7903 8.2 208.28

8 AWG Multi-conductor Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27149A 2 ** Bulk Bulk 220.0 327.4 .060 1.52 .560 14.22 384 1709 5.6 142.24
FT4/IEEE 1202/383
ICEA S-73-532 27150A 3 ** 1000 304.8 354.0 527.0 .060 1.52 .590 14.99 576 2563 5.9 149.86
ICEA S-95-658 Bulk Bulk 354.0 527.0
ICEA S-61-402 27151A 4 Bulk Bulk 394.0 327.4 .060 1.52 .650 16.51 768 3418 6.5 165.10
ICEA T-29-520 **

Rip Cord

**ICEA Method 4 Color Code

6 AWG Multi-conductor Stranded (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27152A 2 ** Bulk Bulk 316.0 434.6 .060 1.52 .630 16.00 610 2715 6.3 160.02
FT4/IEEE 1202/383
ICEA S-73-532 27153A 3 ** 1000 304.8 477.0 710.0 .060 1.52 .670 17.02 915 4072 6.7 170.18
ICEA S-95-658 Bulk Bulk 477.0 710.0
ICEA S-61-402 27154A 4 Bulk Bulk 519.0 759.0 .060 1.52 .730 18.54 1220 5429 7.3 185.42
ICEA T-29-520 **

Rip Cord

**ICEA Method 4 Color Code


E2 = Refer to Technical Information section for color code.
† Flat construction; overall shield not available.
†† Twisted Conductors. Conductor, Insulation and Jacket Options
Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction. To Specify: Bare Tinned Insulation/Jacket
12345 A S A B PVC-Nylon/PVC
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil®
No. type Shield G H XLPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply K L TPE/TPE
replace the second digit of the part number from a 7 to an 8. M N PVC-Nylon/Oil Res II
For example: 27080A with TC-ER rating becomes 28080A. Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.69

UL Control Cable
600V Type TC Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Standard Jacket Nominal Maximum Minimum


No. Weight
Part Color Lengths Thickness OD Pull Tension Bend Radius
Description of
No. Code Lbs./
Cond. Ft. m kg/km Inch mm Inch mm Lbs. N Inch mm
1000′

4 AWG Multi-conductor Stranded (7x12) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27155A 2 ** Bulk Bulk 455.0 677.1 .060 1.52 .770 19.56 970 4317 7.7 195.58
FT4/IEEE 1202/383
ICEA S-73-532 27156A 3 ** Bulk Bulk 630.0 937.6 .080 2.03 .820 20.83 1455 6475 8.2 208.28
ICEA S-95-658 27157A 4 Bulk Bulk 850.0 1265.0 .080 2.03 .950 24.13 1940 8633 9.5 241.30
**
ICEA S-61-402
ICEA T-29-520

Rip Cord

**ICEA Method 4 Color Code

2 AWG Multi-conductor Stranded (7x10) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27158A 2 ** Bulk Bulk 716.0 1065.6 .080 2.03 .970 24.64 1544 6871 9.7 246.38
FT4/IEEE 1202/383
ICEA S-73-532 27159A 3 ** Bulk Bulk 960.0 1428.7 .080 2.03 .990 25.15 2316 10306 9.9 251.46
ICEA S-95-658 27160A 4 Bulk Bulk 1213.0 1805.2 .080 2.03 1.090 27.69 3088 13742 10.9 276.86
ICEA S-61-402
**
ICEA T-29-520

Rip Cord

**ICEA Method 4 Color Code

1 AWG Multi-conductor Stranded (19x14) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
PVC/Nylon Insulation and PVC Jacket Constructions (See chart below for other options)
NEC: TC, NPLF 27161A 3 ** Bulk Bulk — — .080 2.03 1.120 28.45 2919 12990 11.2 284.48
FT4/IEEE 1202/383
ICEA S-73-532
ICEA S-95-658
ICEA S-61-402
ICEA T-29-520

Rip Cord

**ICEA Method 4 Color Code


Bulk = 5000 ft. or 10,000 ft. put-up one piece, ±10%. Check length available for specific construction.

Conductor, Insulation and Jacket Options


To Specify: Bare Tinned Insulation/Jacket
18 • Industrial Cables

12345 A S A B PVC-Nylon/PVC
Start add add C D XLPE/PVC
with Conductor, “S” for
core Insulation, optional E F FRPO/PVC
Part Jacket Beldfoil®
No. type Shield G H XLPE/TPE
Note: To specify TC-ER (Exposed Run) rated control cable, simply K L TPE/TPE
replace the second digit of the part number from a 7 to an 8. M N PVC-Nylon/Oil Res II
For example: 27080A with TC-ER rating becomes 28080A. Q R XLPE/CPE
S T XLPE/Haloarrest®

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70

UL Control Cable
600V Type MC Metal Clad and Teck-Style® Cables — Overview

Metal Clad Construction Design Advantages

Class B stranded bare copper conductors, Insulation Properties


cross-linked polyethylene insulation, bare ● High tensile strength
copper ground wire, standard aluminum or
optional galvanized steel interlocking ● Impact- and crush-resistant
armor, PVC outer jacket. ● Heat-resistant
Polyester Wrap ● Thermoset insulation — ● Excellent elongation
Interlocked Armor XHHW-2 conductors
XLPE Insulation ● Moisture-resistant
PVC Outer Jacket ● NEC conductor temperature
90°C dry and 90°C wet ● Good low temperature properties
● 90°C dry and 90°C wet
Teck-Style
Voltage Rating
Electrical Properties
14 AWG — 2 AWG: 600 Volt ● High insulation resistance
● Low dielectric loss
Application ● High dielectric strength

Inner Jacket Type MC Cable is a general-purpose Other Features


cable used in the pulp and paper, mining,
Interlocked Armor petroleum and chemical industries as ● Corrosion-resistant
XLPE Insulation
PVC Outer Jacket well as in commercial buildings. ● Versatile and flexible
MC Cable may be used under the ● Provides cost savings as conduit
following conditions: and ducts are not required
● Exposed or concealed wiring in
Introduction dry or wet conditions
Specifications
Belden® Metal Clad (MC) and Teck-Style ● In ventilated, non-ventilated or
cables are designed to meet demanding ladder-type cable trays in dry or ● UL 44
industrial needs by combining rugged wet conditions
● UL 1569
durability and corrosion resistance with
● On walls or beams
flexibility and easy handling. ● UL 1685 (UL 1581) Vertical Tray
● Directly buried
MC and Teck-Style cables are available Flame Test (70,000 BTU/hr)
in a wide range of constructions to meet ● Class I and II Div. 2 and Class III
the needs of pulp and paper, chemical, Div. 1 and 2 hazardous locations
petroleum and other demanding industrial Tech-Style CSA Specifications
and resource industry environments. They
● CSA C22.2 #131
are ideal for use in wet or dry areas; Minimum Bending Radius
ventilated, non-ventilated or ladder-type ● FT4 Flame Test
cable troughs; ventilated flexible cableways; 12 times the overall cable diameter
● HAZ LOC
and for direct burial. Custom cables are
available to meet exacting requirements. ● CSA C22.2 #0.3
Pulling Tensions Clause 4.31 Low Acid Gas
Belden Type MC Cable is marked
sunlight-resistant for cable tray use The combined use of Kellems grips
in direct burial designations, and cable and pulling eyes is recommended.
constructions are listed to NEC Type MC.
Teck-Style cables are price-competitive,
high-performance, UL and CSA dual-rated
cables with a flame-retardant XHHW
insulated conductor and an inner PVC
jacket for mechanical moisture and
corrosion protection.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.71

UL Control Cable
600V Type MC Metal Clad Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Insulation Outer Jacket Minimum


Part Number No. Armor OD Nominal OD
Thickness Thickness Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Inch mm
Armor Armor

14 AWG Stranded (7x22) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27243 28243 2 .030 .76 .050 1.27 .48 12.19 .58 14.73 7.3 185.42
27244 28244 3 .030 .76 .050 1.27 .50 12.70 .61 15.49 7.6 193.04
27245 28245 4 .030 .76 .050 1.27 .54 13.72 .64 16.26 7.9 200.66
27246 28246 5 .030 .76 .050 1.27 .57 14.48 .68 17.27 8.4 213.36
27247 28247 6 .030 .76 .050 1.27 .62 15.75 .72 18.29 8.9 226.06
27248 28248 7 .030 .76 .050 1.27 .62 15.75 .72 18.29 8.9 226.06
27269 28269 8 .030 .76 .050 1.27 .69 17.53 .80 20.32 9.4 238.76
27535 28535 9 .030 .76 .050 1.27 .70 17.78 .80 20.32 10.0 254.00
27249 28249 10 .030 .76 .050 1.27 .75 19.05 .85 21.59 10.5 266.70
27250 28250 12 .030 .76 .050 1.27 .77 19.56 .87 22.10 10.8 274.32
27251 28251 15 .030 .76 .050 1.27 .87 22.10 .98 24.89 11.6 294.64
27969 28969 19 .030 .76 .050 1.27 1.00 25.40 1.11 28.19 12.1 307.34
27252 28252 20 .030 .76 .050 1.27 1.03 26.16 1.14 28.96 13.3 337.82
27270 28270 25 .030 .76 .050 1.27 1.10 27.94 1.21 30.73 14.4 365.76
27253 28253 30 .030 .76 .050 1.27 1.18 29.97 1.29 32.77 15.1 383.54
27292 28292 37 .030 .76 .050 1.27 1.14 28.96 1.24 31.50 16.1 408.94
27433 28433 40 .030 .76 .050 1.27 1.28 32.51 1.40 35.56 16.7 424.18
27434 28434 50 .030 .76 .050 1.27 1.40 35.56 1.52 38.61 18.4 467.36

12 AWG Stranded (7x20) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27254 28254 2 .030 .76 .050 1.27 .52 13.21 .62 15.75 7.8 198.12
27255 28255 3 .030 .76 .050 1.27 .54 13.72 .64 16.26 8.0 203.20
27256 28256 4 .030 .76 .050 1.27 .58 14.73 .68 17.22 8.5 215.90
27271 28271 5 .030 .76 .050 1.27 .62 15.75 .72 18.29 9.1 231.14
27272 28272 6 .030 .76 .050 1.27 .67 17.02 .77 19.56 9.6 243.84
27273 28273 7 .030 .76 .050 1.27 .67 17.02 .77 19.56 9.6 243.84
27274 28274 8 .030 .76 .050 1.27 .77 19.56 .88 22.35 10.2 259.08
27538 28538 9 .030 .76 .050 1.27 .76 19.30 .86 21.84 10.8 274.32
27275 28275 10 .030 .76 .050 1.27 .80 20.32 .91 23.11 11.5 292.10
27276 28276 12 .030 .76 .050 1.27 .84 21.34 .94 23.88 11.7 297.18
27277 28277 15 .030 .76 .050 1.27 .94 23.88 1.05 26.67 13.4 340.36
27539 28539 19 .030 .76 .055 1.40 1.05 26.67 1.16 29.46 14.0 355.60
27278 28278 20 .030 .76 .055 1.40 1.16 29.46 1.27 32.26 14.6 370.84
27279 28279 25 .030 .76 .055 1.40 1.26 32.00 1.37 34.80 15.8 401.32
27280 28280 30 .030 .76 .055 1.40 1.29 32.77 1.40 35.56 16.8 426.72
27540 28540 37 .030 .76 .055 1.40 1.44 36.58 1.55 39.37 17.8 452.12
27432 28432 40 .030 .76 .055 1.40 1.50 38.10 1.63 41.40 18.4 467.36
Color Code: Use ICEA Table E2 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.
18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.72

UL Control Cable
600V Type MC Metal Clad Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Insulation Outer Jacket Minimum


Part Number No. Armor OD Nominal OD
Thickness Thickness Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Inch mm
Armor Armor

10 AWG Stranded (7x18) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27257 28257 2 .030 .76 .050 1.27 .56 14.22 .67 17.02 8.4 213.36
27258 28258 3 .030 .76 .050 1.27 .58 14.73 .69 17.53 8.6 218.44
27259 28259 4 .030 .76 .050 1.27 .62 15.75 .74 18.80 9.2 233.68
27281 28281 5 .030 .76 .050 1.27 .68 17.27 .79 20.07 12.8 325.12
27282 28282 6 .030 .76 .050 1.27 .74 18.80 .84 21.34 10.4 264.16
27283 28283 7 .030 .76 .050 1.27 .74 18.80 .84 21.34 10.4 264.16
27284 28284 8 .030 .76 .050 1.27 .81 20.57 .92 23.37 11.2 284.48
27541 28541 9 .030 .76 .050 1.27 .87 22.10 .98 24.89 11.8 299.72
27285 28285 10 .030 .76 .050 1.27 .89 22.61 1.03 26.16 13.3 337.82
27286 28286 12 .030 .76 .050 1.27 1.01 25.65 1.12 28.45 13.7 347.98
27287 28287 15 .030 .76 .050 1.27 1.09 27.69 1.22 30.99 14.8 375.92
27288 28288 20 .030 .76 .055 1.40 1.22 30.99 1.35 34.29 16.2 411.48
27289 28289 25 .030 .76 .055 1.40 1.32 33.53 1.47 37.34 17.8 452.12
27290 28290 30 .030 .76 .055 1.40 1.42 36.07 1.55 39.37 18.6 472.44

8 AWG Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27291 28291 2 .045 1.14 .050 1.27 .70 17.78 .81 20.57 9.8 248.92
27260 28260 3 .045 1.14 .050 1.27 .72 18.29 .82 20.83 10.2 259.08
27261 28261 4 .045 1.14 .050 1.27 .78 19.81 .88 22.35 10.9 276.86

6 AWG Stranded (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27293 28293 2 .045 1.14 .050 1.27 .76 19.30 .87 22.10 10.7 271.78
27262 28262 3 .045 1.14 .050 1.27 .80 20.32 .90 22.86 11.2 284.48
27263 28263 4 .045 1.14 .050 1.27 .87 22.10 .97 24.64 12.1 307.34

Color Code: For sizes 14, 12, 10, use ICEA Table E2 with printed numbers.
For sizes 8 and larger, use ICEA Method 4 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.73

UL Control Cable
600V Type MC Metal Clad Cables
Industrial Grade Sunlight- and Oil-Resistant Jackets

Insulation Outer Jacket Minimum


Part Number No. Armor OD Nominal OD
Thickness Thickness Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Inch mm
Armor Armor

4 AWG Stranded (7x12) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27264 28264 3 .045 1.14 .050 1.27 .90 22.86 1.00 25.40 13.1 332.74
27265 28265 4 .045 1.14 .050 1.27 1.97 50.04 1.08 27.43 14.2 360.68

2 AWG Stranded (7x10) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27267 28267 3 .045 1.14 .050 1.27 1.02 25.91 1.13 28.70 14.7 373.38
27268 28268 4 .045 1.14 .050 1.27 1.11 28.19 1.22 30.99 16.0 406.40

Composite 14 AWG (7x22) and 12 AWG (7x20) Stranded Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27428 28428 3c/14 .030 .76 .050 1.27 .70 17.78 .81 20.57 9.7 246.38
3c/12 .030 .76

Composite 14 AWG (7x22) and 10 AWG (7x18) Stranded Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27429 28429 3c/14 .030 .76 .050 1.27 .74 18.80 .85 21.59 10.2 259.08
3c/10 .030 .76

Composite 14 AWG (7x22) and 8 AWG (7x16) Stranded Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27430 28430 3c/14 .030 .76 .050 1.27 .83 21.08 .94 23.88 11.2 284.48
3c/8 .045 1.14

Composite 14 AWG (7x22) and 6 AWG (7x14) Stranded Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Interlocked Armor • Cross-linked Polyethylene Insulation • PVC Jacket
NEC: MC 27431 28431 3c/14 .030 .76 .050 1.27 .89 22.61 1.01 25.65 12.0 304.80
3c/6 .045 1.14
18 • Industrial Cables

Color Code: For sizes 14, 12, 10, use ICEA Table E2 with printed numbers.
For sizes 8 and larger, use ICEA Method 4 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.74

UL Control Cable
600V Teck-Style® Cables
Dual-Rated Type MC/Teck 90

Insulation Inner Jacket Armor Nominal Maximum Minimum


Part Number No. Thickness OD OD OD Pull Tension Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Lbs. N Inch mm
Armor Armor

14 AWG Stranded (7x22) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27840 28840 2 .030 .76 .37 9.40 .56 14.22 .67 17.02 66 294 8.0 203
27841 28841 3 .030 .76 .39 9.91 .58 14.73 .69 17.53 98 436 8.3 211
27842 28842 4 .030 .76 .43 10.92 .62 15.75 .73 18.54 131 583 8.7 221
27843 28843 5 .030 .76 .47 11.94 .66 16.76 .77 19.56 164 730 9.2 234
27844 28844 6 .030 .76 .51 12.95 .70 17.78 .81 20.57 191 850 9.7 246
27845 28845 7 .030 .76 .51 12.95 .70 17.78 .81 20.57 225 1001 9.7 246
27846 28846 8 .030 .76 .58 14.73 .77 19.56 .88 22.35 260 1157 10.5 267
27847 28847 10 .030 .76 .67 17.02 .93 23.62 1.04 26.42 321 1428 12.5 318
27848 28848 12 .030 .76 .69 17.53 .95 24.13 1.06 26.92 388 1726 10.9 277
27849 28849 15 .030 .76 .77 19.56 1.03 26.16 1.14 28.96 481 2140 13.7 348
27850 28850 20 .030 .76 .86 21.84 1.12 28.45 1.23 31.24 649 2887 15.3 389
27851 28851 25 .030 .76 .92 23.37 1.18 29.97 1.30 33.02 810 3603 16.3 414
27852 28852 30 .030 .76 .98 24.89 1.24 31.50 1.36 34.54 975 4337 17.0 432
CSA C22.2 #131
27885 28885 40 .030 .76 1.09 27.69 1.35 34.29 1.47 37.34 1301 5787 18.5 470
FT4 Flame Test, HAZ LOC
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 27886 28886 50 .030 .76 1.19 30.23 1.45 36.83 1.57 39.88 1630 7251 19.8 503

12 AWG Stranded (7x20) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27853 28853 2 .030 .76 .41 10.41 .60 15.24 .71 18.03 104 463 8.5 216
27854 28854 3 .030 .76 .43 10.92 .62 15.75 .73 18.54 156 694 8.8 224
27855 28855 4 .030 .76 .47 11.94 .66 16.76 .77 19.56 207 921 9.2 234
27856 28856 5 .030 .76 .52 13.21 .71 18.03 .82 20.83 260 1157 9.8 249
27857 28857 6 .030 .76 .59 14.99 .78 19.81 .89 22.61 310 1379 10.7 272
27858 28858 7 .030 .76 .59 14.99 .78 19.81 .89 22.61 361 1606 10.7 272
27859 28859 8 .030 .76 .64 16.26 .83 21.08 .94 23.88 415 1846 11.3 287
27860 28860 10 .030 .76 .75 19.05 1.01 25.65 1.12 28.45 520 2313 13.4 340
27861 28861 12 .030 .76 .77 19.56 1.03 26.16 1.14 28.96 619 2753 13.7 348
27862 28862 15 .030 .76 .87 22.10 1.13 28.70 1.25 31.75 718 3194 15.0 381
27863 28863 20 .030 .76 .96 24.38 1.22 30.99 1.33 33.78 1040 4626 15.9 404
27864 28864 25 .030 .76 1.04 26.42 1.30 33.02 1.42 36.07 1301 5787 17.0 432
CSA C22.2 #131
27865 28865 30 .030 .76 1.15 29.21 1.41 35.81 1.53 38.86 1560 6939 18.3 465
FT4 Flame Test, HAZ LOC
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 27887 28887 40 .030 .76 1.20 30.48 1.54 39.12 1.67 42.42 2020 8985 20.0 508
Color Code: Use ICEA Table E2 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.75

UL Control Cable
600V Teck-Style® Cables
Dual-Rated Type MC/Teck 90

Insulation Inner Jacket Armor Nominal Maximum Minimum


Part Number No. Thickness OD OD OD Pull Tension Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Lbs. N Inch mm
Armor Armor

10 AWG Stranded (7x18) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27866 28866 2 .030 .76 .46 11.68 .65 16.51 .74 18.80 166 738 9.1 231
27867 28867 3 .030 .76 .48 12.19 .67 17.02 .77 19.56 249 1108 9.4 239
27868 28868 4 .030 .76 .56 14.22 .75 19.05 .84 21.34 330 1468 10.3 262
27869 28869 5 .030 .76 .67 17.02 .86 21.84 .96 24.38 415 1846 11.6 295
27870 28870 6 .030 .76 .67 17.02 .86 21.84 .96 24.38 491 2184 11.6 295
27877 28877 7 .030 .76 .70 17.78 .90 22.86 1.00 25.40 560 2491 12.1 307
27878 28878 8 .030 .76 .75 19.05 .95 24.13 1.05 26.67 640 2847 12.7 323
27879 28879 10 .030 .76 .78 19.81 1.04 26.42 1.15 29.21 801 3563 13.8 351
27880 28880 12 .030 .76 .89 22.61 1.15 29.21 1.26 32.00 960 4270 15.1 384
27881 28881 15 .030 .76 .93 23.62 1.19 30.23 1.30 33.02 1195 5316 15.6 396
27882 28882 20 .030 .76 1.06 26.92 1.32 33.53 1.44 36.58 1600 7117 17.3 439
CSA C22.2 #131
27883 28883 25 .030 .76 1.12 28.45 1.44 36.58 1.58 40.13 1990 8852 19.0 483
FT4 Flame Test, HAZ LOC
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 27884 28884 30 .030 .76 1.28 32.51 1.54 39.12 1.67 42.42 2355 10476 20.0 508

8 AWG Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27871 28871 2 .045 1.14 .59 14.99 .78 19.81 .89 22.61 264 1174 10.7 272
27872 28872 3 .045 1.14 .62 15.75 .81 20.57 .91 23.11 396 1762 10.9 277
27873 28873 4 .045 1.14 .68 17.27 .94 23.88 1.05 26.67 528 2349 12.6 320

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

6 AWG Stranded (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27874 28874 2 .060 1.52 .71 18.03 .97 24.64 1.08 27.43 420 1868 13.0 330
27875 28875 3 .060 1.52 .76 19.30 1.02 25.91 1.13 28.70 630 2802 13.5 343
27876 28876 4 .060 1.52 .88 22.35 1.14 28.96 1.25 31.75 840 3737 15.0 381

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

4 AWG Stranded (7x12) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27894 28894 3 .060 1.52 .91 23.11 1.17 29.72 1.29 32.77 1002 4457 15.5 394
27895 28895 4 .060 1.52 .99 25.15 1.25 31.75 1.37 34.80 1335 5938 16.4 417

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

3 AWG Stranded (7x11) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27896 28896 3 .060 1.52 .96 24.38 1.22 30.99 1.33 33.78 1263 5618 16.0 406
18 • Industrial Cables

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas
Color Code: For sizes 14, 12, 10, use ICEA Table E2 with printed numbers.
For sizes 8 and larger, use ICEA Method 4 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.76

UL Control Cable
600V Teck-Style® Cables
Dual-Rated Type MC/Teck 90

Insulation Inner Jacket Armor Nominal Maximum Minimum


Part Number No. Thickness OD OD OD Pull Tension Bend Radius
Description of
Aluminum Steel Cond. Inch mm Inch mm Inch mm Inch mm Lbs. N Inch mm
Armor Armor

2 AWG Stranded (7x10) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27888 28888 3 .060 1.52 1.08 27.43 1.28 32.51 1.40 35.56 1593 7086 16.8 427
27889 28889 4 .060 1.52 1.12 28.45 1.38 35.05 1.50 38.10 2124 9448 18.0 457

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG (7x22) and 12 AWG (7x20) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27890 28890 3c/14 .030 .76 .56 14.22 .75 19.05 .86 21.84 202 899 10.3 262
3c/12 .030 .76

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG (7x22) and 10 AWG (7x18) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27891 28891 3c/14 .030 .76 .61 15.49 .80 20.32 .91 23.11 305 1357 10.9 277
3c/10 .030 .76

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG (7x22) and 8 AWG (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27892 28892 3c/14 .045 1.14 .70 17.78 .96 24.38 1.07 27.18 435 1935 12.8 325
3c/8 .030 .76

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG (7x22) and 6 AWG (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum or Steel Armor • Cross-linked Polyethylene Insulation • PVC Inner Jacket • PVC Outer Jacket
NEC: MC 27893 28893 3c/14 .060 1.52 .90 22.86 1.15 29.21 1.26 32.00 655 2914 15.1 384
3c/6 .030 .76

CSA C22.2 #131, FT4 Flame Test, HAZ LOC, CSA C22.2 #0.3 Clause 4.31 Low Acid Gas
Color Code: For sizes 14, 12, 10, use ICEA Table E2 with printed numbers.
For sizes 8 and larger, use ICEA Method 4 with printed numbers.
Non-stocked items. Check length available for specific construction. Minimum order may apply.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.77

CSA Instrumentation & Thermocouple Tray Cable


300V TC/CIC
Paired and Triad Constructions

Cable Specifications Part Numbers


No.
of Solid Solid Solid Solid
● CSA C22.2 #239 Control 7 Strand
Pairs EX Chromel/ JX Iron/ KX Chromel/ TX Copper/
Copper
and Instrumentation Constantan Constantan Alumel Constantan

● CSA C22.2 #230 Type TC 20 AWG


1 22000 21100 21114 21128 21142
● CSA FT4 70,000 BTU Flame Test 2 22001 21101 21115 21129 21143

4 22002 21102 21116 21130 21144
PVC Insulation 90°C Dry & 75°C Wet
6 22003 21103 21117 21131 21145
● XLPE Insulation Optional 90°C 8 22004 21104 21118 21132 21146
Dry and Wet 10 22005 21105 21119 21133 21147
12 22006 21106 21120 21134 21148
● -40°C Cold Bend, -25°C Cold Impact 16 22007 21107 21121 21135 21149
20 22008 21108 21122 21136 21150
● -25°C Installation temp 24 22009 21109 21123 21137 21151
30 22010 21110 21124 21138 21152
● Per CEC Part 1, Suitable for use 36 22011 21111 21125 21139 21153
in hazardous locations: 40 22012 21112 21126 21140 21154
Class 1 – Zone 2 50 22013 21113 21127 21141 21155
Class 2 – Division 2 18 AWG

1 22027 21156 21170 21184 21198
Sun Res/UV resistant
2 22028 21157 21171 21185 21199
● Direct Burial 4 22029 21158 21172 21186 21200
6 22030 21159 21173 21187 21201
8 22031 21160 21174 21188 21202
10 22032 21161 21175 21189 21203
To Create a Part Number 12 22033 21162 21176 21190 21204
16 22034 21163 21177 21191 21205
Add suffixes for Conductor, Insulation and 20 22035 21164 21178 21192 21206
Jacket Type and Shielding as shown below: 24 22036 21165 21179 21193 21207
30 22037 21166 21180 21194 21208
A = Bare Copper Conductor or Thermocouple
alloy, PVC insulation, PVC Jacket 36 22038 21167 21181 21195 21209
40 22039 21168 21182 21196 21210
B = Tinned Copper Conductor, 50 22040 21169 21183 21197 21211
PVC Insulation, PVC Jacket
16 AWG
C = Bare Copper Conductor or Thermocouple 1 22054 21212 21226 21240 21254
alloy, XLPE Insulation, PVC Jacket
2 22055 21213 21227 21241 21255
D = Tinned Copper Conductor, 4 22056 21214 21228 21242 21256
XLPE Insulation, PVC Jacket 6 22057 21215 21229 21243 21257
8 22058 21216 21230 21244 21258
1 = Overall Foil Shield + Drain Wire 10 22059 21217 21231 21245 21259
2 = Individual and Overall Foil Shield + Drain Wire 12 22060 21218 21232 21246 21260
16 22061 21219 21233 21247 21261
20 22062 21220 21234 21248 21262
Sample Part Number: 24 22063 21221 21235 21249 21263
22001B2 = 300V, 2-Pair 20 AWG Tinned Copper 30 22064 21222 21236 21250 21264
Conductor cable with PVC Insulation, 36 22065 21223 21237 21251 21265
PVC Jacket, with Individual and 40 22066 21224 21238 21252 21266
Overall Foil Shields plus Drain Wire 50 22067 21225 21239 21253 21267

Thermocouple Color Codes Triad Constructions, Copper Conductor


ANSI Jacket Insulation Color Code Part Numbers
No.
Symbol Color Positive ( + ) Negative ( - ) of
20 AWG 18 AWG 16 AWG
Triads (7 Strand) (7 Strand) (7 Strand)
EX Purple Purple Red
JX Black White Red 1 22014 22041 22068
KX Yellow Yellow Red 2 22015 22042 22069
TX Blue Blue Red 4 22016 22043 22070
18 • Industrial Cables

6 22017 22044 22071


Copper Color Codes 8 22018 22045 22072
10 22019 22046 22073
Pairs/Triads Color Combination 12 22020 22047 22074
Pairs Black & White 16 22021 22048 22075
Triads Black, White & Red 20 22022 22049 22076
24 22023 22050 22077
30 22024 22051 22078
36 22025 22052 22079

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.78

CSA Instrumentation Cable


300V CIC

Belden offers a complete line of high performance and high quality Contact Belden Customer Service for other options:
CSA certified instrumentation cables (300V/600V and CIC/ACIC). ● 150V
These cables are designed to minimize noise and signal interference ● XLPE insulation (add D suffix to part number)
to deliver clean signals in harsh petrochemical, pulp and paper ● Thermocouple alloy conductors
and process industry environments, as well as for use in general ● Overall foil shield only
manufacturing operations. ● Other pair and triad counts

No. Cable Weight Jacket Thickness Nominal OD


Part of
Description Pairs
Number
or Triads Lbs./1000 Ft. kg/km Inch mm Inch mm

20 AWG Pairs Stranded (7x28) TC Conductors • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black and White with Numbers)
CSA C22.2#239, Type CIC 22671* 1 71 106 .045 1.14 .260 6.60
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22638 2 143 213 .045 1.14 .400 10.16
FT4 Flame Test
22639 4 217 323 .045 1.14 .460 11.68
22640 6 320 476 .045 1.14 .570 14.48
22641 8 405 603 .060 1.52 .610 15.49
22676 12 573 853 .060 1.52 .730 18.54
Rip Cord
Drain Wires
22643 16 722 1076 .060 1.52 .810 20.57
22647 24 1103 1641 .080 2.03 1.040 26.42
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet) 22670 36 1548 2304 .080 2.03 1.190 30.23

20 AWG Triads Stranded (7x28) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black, White and Red with Numbers)
CSA C22.2#239, Type CIC 22660* 1 89 132 .045 1.14 .270 6.86
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22662 2 177 263 .045 1.14 .420 10.67
FT4 Flame Test
22663 4 277 412 .045 1.14 .490 12.45
22672 8 521 775 .060 1.52 .650 16.51
22673 16 1000 1488 .080 2.03 .910 23.11
22674 24 1414 2104 .080 2.03 1.110 28.19
Rip Cord
Drain Wires

-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

18 AWG Pairs Stranded (7x26) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black and White with Numbers)
CSA C22.2#239, Type CIC 22645* 1 97 144 .045 1.14 .300 7.62
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22633 2 196 292 .045 1.14 .480 12.19
FT4 Flame Test
22648 4 338 503 .045 1.14 .580 14.73
22634 6 473 704 .060 1.52 .670 17.02
22635 8 570 848 .060 1.52 .730 18.54
22636 12 869 1293 .060 1.52 .920 23.37
Rip Cord
Drain Wires
22654 16 1095 1630 .080 2.03 1.020 25.91
22637 24 1552 2310 .080 2.03 1.260 32.00
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

18 AWG Triads Stranded (7x26) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black, White and Red with Numbers)
CSA C22.2#239, Type CIC 22677* 1 121 180 .045 1.14 .303 7.70
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22678 2 256 381 .045 1.14 .480 12.19
FT4 Flame Test
22679 4 427 636 .060 1.52 .620 15.75
22680 8 597 888 .060 1.52 .710 18.03
22681 16 740 1101 .060 1.52 .770 19.56
22682 24 1130 1682 .080 2.03 .980 24.89
Rip Cord
22683 16 1436 2137 .080 2.03 1.090 27.69
Drain Wires
22684 24 2049 3049 .080 2.03 1.340 34.04
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)
*One pair/triad cables have one shield and drain wire TC = Tinned Copper

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.79

CSA Instrumentation Cable


300V CIC

No. Cable Weight Jacket Thickness Nominal OD


Part of
Description Pairs
Number
or Triads Lbs./1000 Ft. kg/km Inch mm Inch mm

16 AWG Pairs Stranded (7x24) TC Conductors • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black and White with Numbers)
CSA C22.2#239, Type CIC 22646* 1 122 182 .045 1.14 .320 8.13
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22628 2 262 390 .045 1.14 .520 13.21
FT4 Flame Test
22629 4 438 652 .060 1.52 .628 15.95
22630 6 603 897 .060 1.52 .740 18.80
22631 8 752 1119 .060 1.52 .800 20.32
22632 12 1148 1708 .080 2.03 1.010 25.65
Rip Cord 22685 16 1461 2174 .080 2.03 1.120 28.45
Drain Wires
22686 24 2091 3112 .080 2.03 1.380 35.05
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)

16 AWG Triads Stranded (7x24) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black, White and Red with Numbers)
CSA C22.2#239, Type CIC 22603* 1 152 226 .045 1.14 .329 8.36
CSA C22.2 #0.3 Clause 4.31 Low Acid Gas 22687 2 344 512 .045 1.14 .580 14.73
FT4 Flame Test
22675 4 564 839 .060 1.52 .670 17.02
22688 6 819 1219 .060 1.52 .780 19.81
22689 8 1063 1582 .080 2.03 .940 23.88
22690 12 1524 2268 .080 2.03 1.080 27.43
Rip Cord
Drain Wires

-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)
TC = Tinned Copper
*One pair/triad cables have one shield and drain wire

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.80

CSA Instrumentation Cable


300V ACIC Armored Cables

No. Cable Weight Cable Weight Insulation Nominal OD Nominal OD


Part No.
of Aluminum Armor Steel Armor Thickness Inner Jacket Outer Jacket
Description Pairs/ Lbs./
Aluminum Steel Lbs./
Armor Armor Triads 1000 Ft. kg/km 1000 Ft. kg/km Inch mm Inch mm Inch mm

20 AWG Pairs Stranded (7x28) TC Cond. • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage) • Drain Wires
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23543** 26530** 1 140 208 230 342 .020 .51 .26 6.6 .56 14.2
CSA C22.2#174, HLABCD 23534 26531 2 206 307 325 484 .020 .51 .40 10.2 .70 17.8
CSA C22.2#0.3, Clause 4.31
Low Acid Gas 23514 26532 4 255 379 390 580 .020 .51 .46 11.7 .76 19.3
FT4 Flame Test 23513 26533 6 297 442 494 735 .020 .51 .57 14.5 .88 22.4
23503 26534 8 361 537 563 840 .020 .51 .63 16.0 .92 23.4
23521 26535 12 480 714 694 1033 .020 .51 .75 19.1 1.06 26.9
23532 26536 16 600 893 900 1339 .020 .51 .79 20.1 1.16 29.5
23506 26537 24 800 1191 1175 1749 .020 .51 1.05 26.7 1.42 36.1
Rip Cord
Drain Wires 23544 26538 36 1050 1563 1500 2232 .020 .51 1.14 29.0 1.57 39.9
-25°C Installed 23575 26546 50 1468 2185 2010 2991 .020 .51 1.37 34.8 1.75 44.5
-40°C to +105°C (Dry) (75°C Wet)

20 AWG Triads Stranded (7x28) TC Cond. • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage) • Drain Wires
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23545** 26539** 1 139 207 235 350 .020 .51 .27 6.9 .57 14.5
CSA C22.2#174, HLBCD 23546 26540 2 210 313 345 513 .020 .51 .43 10.9 .73 18.5
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 23547 26541 4 270 402 425 632 .020 .51 .50 12.7 .80 20.3
23548 26542 8 444 661 650 967 .020 .51 .69 17.5 1.00 25.4
23571 26553 12 632 941 970 1444 .020 .51 .82 20.8 1.24 31.5
23549 26543 16 740 1101 1090 1622 .020 .51 .91 23.1 1.28 32.5
23550 26544 24 990 1473 1360 2024 .020 .51 1.11 28.2 1.48 37.6

Rip Cord
Drain Wires
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

18 AWG Pairs Stranded (7x26) TC Cond. • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage) • Drain Wires
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23533** 26514** 1 160 238 258 384 .025 .64 .30 7.6 .60 15.2
CSA C22.2#174, HLABCD 23511 26515 2 247 368 384 572 .025 .64 .48 12.2 .78 19.8
CSA C22.2#0.3, Clause 4.31
Low Acid Gas 23530 26516 4 340 506 500 744 .025 .64 .58 14.7 .88 22.4
FT4 Flame Test 23528 26517 6 420 625 644 958 .025 .64 .67 17.0 .98 24.9
23531 26518 8 543 808 827 1230 .025 .64 .73 18.5 1.03 26.2
23524 26519 12 725 1079 1045 1555 .025 .64 .90 22.9 1.28 32.5
23519 26520 16 850 1265 1210 1801 .025 .64 .99 25.1 1.37 34.8
23542 26521 24 1100 1637 1510 2247 .025 .64 1.24 31.5 1.63 41.4
Rip Cord
23554 26555 36 1465 2180 1960 2917 .025 .64 1.41 35.8 1.80 45.7
Drain Wires
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

18 AWG Triads Stranded (7x26) TC Cond. • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage) • Drain Wires
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23505** 26522** 1 175 260 275 409 .025 .64 .33 8.4 .61 15.5
CSA C22.2#174, HLBCD 23516 26523 2 275 409 417 621 .025 .64 .51 13.0 .81 20.6
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 23515 26524 4 385 573 555 826 .025 .64 .62 15.7 .93 23.6
23508 26525 6 535 796 780 1161 .025 .64 .75 19.1 1.11 28.2
23523 26526 8 680 1012 995 1481 .025 .64 .81 20.6 1.18 30.0
23512 26527 12 916 1363 1215 1808 .025 .64 1.03 26.2 1.40 35.6
23537 26528 16 1020 1518 1400 2083 .025 .64 1.13 28.7 1.50 38.1
23536 26529 24 1335 1987 1775 2642 .025 .64 1.37 34.8 1.80 45.7
Rip Cord
Drain Wires

-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)


Color Code: Pairs — Black and White with Numbers. TC = Tinned Copper *Note: Add D suffix for XLPE insulation. Example: 23543D.
Triads — Black, White and Red with Numbers. **One pair/triad cables have one foil shield and drain wire

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.81

CSA Instrumentation Cable


300V ACIC Armored Cables

No. Cable Weight Cable Weight Insulation Nominal OD Nominal OD


Part No.
of Aluminum Armor Steel Armor Thickness Inner Jacket Outer Jacket
Description Pairs/ Lbs./
Aluminum Steel Lbs./
Armor Armor Triads 1000 Ft. kg/km 1000 Ft. kg/km Inch mm Inch mm Inch mm

16 AWG Pairs Stranded (7x24) TC Conductors • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23501** 26500** 1 175 260 280 417 .025 .64 .33 8.4 .62 15.8
CSA C22.2#174, HLABCD 23527 26501 2 280 417 425 635 .025 .64 .52 13.2 .81 20.6
CSA C22.2#0.3, Clause 4.31
Low Acid Gas 23509 26503 4 395 588 570 848 .025 .64 .63 16.0 .93 23.6
FT4 Flame Test 23500 26504 6 510 759 715 1064 .025 .64 .73 18.5 1.03 26.2
23510 26505 8 625 930 910 1354 .025 .64 .79 20.1 1.16 29.5
23525 26506 12 875 1302 1230 1831 .025 .64 1.00 25.4 1.37 34.8
23539 26507 16 1054 1569 1445 2151 .025 .64 1.12 28.2 1.48 37.6
23538 26508 24 1397 2079 1840 2738 .025 .64 1.36 34.5 1.75 44.5
Rip Cord 23568 26551 36 1920 2857 2460 3661 .025 .64 1.60 40.6 1.97 50.0
Drain Wires
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

16 AWG Triads Stranded (7x24) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 23507** 26502** 1 190 282 295 439 .025 .64 .35 8.9 .63 16.0
CSA C22.2#174, HLBCD 23522 26509 2 342 508 500 744 .025 .64 .58 14.7 .90 22.9
CSA C22.2#0.3, Clause 4.31
Low Acid Gas 23520 26510 4 450 670 640 953 .025 .64 .68 17.3 .95 24.1
FT4 Flame Test 23529 26511 6 650 967 928 1381 .025 .64 .78 19.8 1.19 30.2
23526 26512 8 825 1228 1130 1682 .025 .64 .93 23.6 1.30 33.0
23541 26513 12 1082 1610 1511 2249 .025 .64 1.13 28.7 1.50 38.1
23567 26545 16 1285 1912 1705 2537 .025 .64 1.25 31.8 1.64 41.7
23578 26547 24 1725 2567 2200 3274 .025 .64 1.58 40.1 1.95 49.5

Rip Cord
Drain Wires
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)
TC = Tinned Copper
*Note: Add D suffix for XLPE insulation. Example: 23501D.
**One pair/triad cables have one foil shield and drain wire
Color Code: Pairs — Black and White with Numbers.
Triads — Black, White and Red with Numbers.

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.82

CSA Instrumentation Cable


600V CIC

No. Jacket Nominal


Cable Weight
Part of Thickness OD
Description Pairs
Number Lbs./
or Triads kg/km Inch mm Inch mm
1000 Ft.

18 AWG Pairs Stranded (7x26) TC Conductors • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black and White with Numbers)
CSA C22.2#239, Type CIC 22417* 1 109 162 .045 1.14 .32 8.13
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22405 2 229 341 .045 1.14 .51 12.95
FT4 Flame Test
22404 4 374 557 .060 1.52 .63 16.00
22418 8 632 941 .060 1.52 .79 20.07
22421 12 970 1444 .080 2.03 1.00 25.40
22419 24 1741 2591 .080 2.03 1.36 34.54
Rip Cord
Drain Wires

-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)

18 AWG Triads Stranded (7x26) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black, White and Red with Numbers)
CSA C22.2#239, Type CIC 22442* 1 131 195 .045 1.14 .34 8.64
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22443 2 299 445 .060 1.52 .58 14.73
FT4 Flame Test
22444 4 476 708 .060 1.52 .68 17.27
22445 8 893 1329 .080 2.03 .88 22.35

Rip Cord
Drain Wires
-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)

16 AWG Pairs Stranded (7x24) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black and White with Numbers)
CSA C22.2#239, Type CIC 22416* 1 129 192 .045 1.14 .34 8.64
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22409 2 229 341 .045 1.14 .59 14.99
FT4 Flame Test
22410 4 469 698 .060 1.52 .68 17.27
22446 6 667 993 .060 1.52 .79 20.07
22411 8 841 1252 .080 2.03 .90 22.86
22412 12 1235 1838 .080 2.03 1.09 27.69
Rip Cord 22447 24 2250 3349 .080 2.03 1.49 37.85
Drain Wires

-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)

16 AWG Triads Stranded (7x24) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
PVC Insulation • Black PVC Jacket (Color Code: Black, White and Red with Numbers)
CSA C22.2#239, Type CIC 22413* 1 167 249 .045 1.14 .36 9.14
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22448 2 372 554 .045 1.14 .62 15.88
FT4 Flame Test
22414 4 606 902 .060 1.52 .72 18.29
22415 8 1144 1703 .080 2.03 .96 24.38

Rip Cord
Drain Wires

-25°C Installed
-40°C to +105°C (Dry) (75°C Wet)
TC = Tinned Copper
*One pair/triad cables have one foil shield and drain wire

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.83

CSA Instrumentation Cable


600V ACIC Armored Cables

No. Cable Weight Cable Weight Insulation Nominal OD Nominal OD


Part No.
of Aluminum Armor Steel Armor Thickness Inner Jacket Outer Jacket
Description Pairs/ Lbs./
Aluminum Steel Lbs./
Armor Armor Triads 1000 Ft. kg/km 1000 Ft. kg/km Inch mm Inch mm Inch mm

18 AWG Pairs Stranded (7x26) TC Cond. • Individual Beldfoil® + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 24511** 25506** 1 154 229 257 382 .030 .76 .32 8.13 .61 15.49
CSA C22.2#174, HLABCD 24512 25514 2 238 354 387 575 .030 .76 .51 12.95 .82 20.83
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 24513 25503 4 335 499 504 750 .030 .76 .63 16.00 .93 23.62
24514 25505 8 536 798 829 1233 .030 .76 .79 20.27 1.15 29.21
24515 25501 12 739 1100 1092 1624 .030 .76 1.00 25.40 1.36 34.54
24520 25517 24 1169 1740 1674 2490 .030 .76 1.36 34.54 1.75 44.45

Rip Cord
Drain Wires
-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

18 AWG Triads Stranded (7x26) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 24516** 25500** 1 166 247 276 411 .030 .76 .34 8.64 .63 16.00
CSA C22.2#174, HLBCD 24517 25522 2 293 436 455 677 .030 .76 .58 14.73 .89 22.61
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 24518 25520 4 391 582 572 851 .030 .76 .66 16.76 .99 25.15
24519 25523 8 673 1002 988 1470 .030 .76 .88 22.35 1.29 32.77

Rip Cord
Drain Wires

-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

16 AWG Pairs Stranded (7x24) TC Cond. • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 24500** 25504** 1 171 254 279 415 .030 .76 .34 8.64 .64 16.26
CSA C22.2#174, HLABCD 24505 25510 2 299 445 455 677 .030 .76 .59 14.99 .89 22.61
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 24502 25511 4 450 670 583 868 .030 .76 .68 17.27 .98 24.89
24506 25512 6 576 857 880 1310 .030 .76 .79 20.07 1.16 29.46
24503 25513 8 679 1010 1005 1496 .030 .76 .90 22.86 1.27 32.26
24504 25518 12 908 1351 1280 1905 .030 .76 1.09 27.69 1.46 37.08
24510 25519 24 1502 2235 2030 3021 .030 .76 1.49 37.85 1.88 47.75

Rip Cord
Drain Wires

-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)

16 AWG Triads Stranded (7x24) TC Conductors • Individual Beldfoil + Polyester Isolation Tape • Overall Beldfoil Shield (100% Coverage)
Interlocked Armor • PVC Insulation* • PVC Inner Jacket • Chrome PVC Outer Jacket
CSA C22.2#239, Type ACIC 24501** 25502** 1 195 290 309 460 .030 .76 .36 9.14 .66 16.76
CSA C22.2#174, HLBCD 24507 25507 2 339 505 465 692 .030 .76 .62 15.75 .94 23.88
CSA C22.2#0.3, Clause 4.31
Low Acid Gas, FT4 Flame Test 24508 25509 4 464 691 793 1180 .030 .76 .72 18.29 1.05 26.67
24509 25508 8 807 1201 1250 1860 .030 .76 .96 24.38 1.33 33.78
18 • Industrial Cables

Rip Cord
Drain Wires

-25°C Installed • -40°C to +105°C (Dry) (75°C Wet)


Color Code: Pairs — Black and White with Numbers. TC = Tinned Copper *Note: Add D suffix for XLPE insulation. Example: 24511D.
Triads — Black, White and Red with Numbers. **One pair/triad cables have one foil shield and drain wire

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.84

CSA Control and Power Cable


600V and 1000V TC/CIC Multi-conductor Cables

Cable Specifications Part Numbers


No. of
14 AWG (7 Strand) 12 AWG (7 Strand) 10 AWG (7 Strand)
● CSA C22.2 #230 Type TC Conductors
600V 1000V 600V 1000V 600V 1000V
● CSA C22.2 #239 Control
2 21500 21300 21550 21350 21600 21400
and Instrumentation (600V only)
3 21501 21301 21551 21351 21601 21401
● CSA C22.2 #38 Type TC (1000V only) 4 21502 21302 21552 21352 21602 21402
5 21503 21303 21553 21353 21603 21403
● CSA FT4 70,000 BTU Flame Test 6 21504 21304 21554 21354 21604 21404
7 21505 21305 21555 21355 21605 21405
● 90°C Dry & Wet 8 21506 21306 21556 21356 21606 21406
9 21507 21307 21557 21357 21607 21407
● -40°C Cold Bend, -25°C Cold Impact 10 21508 21308 21558 21358 21608 21408
11 21509 21309 21559 21359 21609 21409
● -25°C Installation temp 12 21510 21310 21560 21360 21610 21410
13 21511 21311 21561 21361 21611 21411
● Per CEC Part 1, Suitable for use 14 21512 21312 21562 21362 21612 21412
in hazardous locations: 15 21513 21313 21563 21363 21613 21413
Class 1 — Zone 2 16 21514 21314 21564 21364 21614 21414
Class 2 — Division 2 17 21515 21315 21565 21365 21615 21415
18 21516 21316 21566 21366 21616 21416
● Sunlight Resistant/UV Resistant 19 21517 21317 21567 21367 21617 21417
20 21518 21318 21568 21368 21618 21418
● Direct Burial 21 21519 21319 21569 21369 21619 21419
22 21520 21320 21570 21370 21620 21420
23 21521 21321 21571 21371 21621 21421
24 21522 21322 21572 21372 21622 21422
To Create a Part Number 25 21523 21323 21573 21373 21623 21423
26 21524 21324 21574 21374 21624 21424
Add suffix “S” for Overall Foil Shielding 27 21525 21325 21575 21375 21625 21425
28 21526 21326 21576 21376 21626 21426
29 21527 21327 21577 21377 21627 21427
Sample Part Number:
30 21528 21328 21578 21378 21628 21428
21500S = 600V CSA Tray Control Cable 31 21529 21329 21579 21379 21629 21429
2-conductor, 14 AWG Bare Copper 32 21530 21330 21580 21380 21630 21430
Conductor with XLPE Insulation, 33 21531 21331 21581 21381 21631 21431
PVC Jacket, and Overall Foil Shield 34 21532 21332 21582 21382 21632 21432
35 21533 21333 21583 21383 21633 21433
36 21534 21334 21584 21384 21634 21434
Color Codes 37 21535 21335 21585 21385 21635 21435
38 21536 21336 21586 21386 21636 21436
No. of Conductors Color Combination
39 21537 21337 21587 21387 21637 21437
2 Black & White 40 21538 21338 21588 21388 21638 21438
3 Black, Red & Blue 41 21539 21339 21589 21389 21639 21439
4 Black, Red, Blue & White 42 21540 21340 21590 21390 21640 21440
5 or more Black & Number Coded 43 21541 21341 21591 21391 21641 21441
44 21542 21342 21592 21392 21642 21442
45 21543 21343 21593 21393 21643 21443
46 21544 21344 21594 21394 21644 21444
47 21545 21345 21595 21395 21645 21445
48 21546 21346 21596 21396 21646 21446
49 21547 21347 21597 21397 21647 21447
50 21548 21348 21598 21398 21648 21448

Part Numbers
No.
8 AWG 6 AWG 4 AWG 3 AWG 2 AWG
of (7 Strand) (7 Strand) (7 Strand) (7 Strand) (7 Strand)
Cond.
600V 1000V 600V 1000V 600V 1000V 600V 1000V 600V 1000V

2 21650 21450 21653 21453 21656 21456 21659 21459 21662 21462
3 21651 21451 21654 21454 21657 21457 21660 21460 21663 21463
4 21652 21452 21655 21455 21658 21458 21661 21461 21664 21464

Part Numbers
No.
1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG
of (19 Strand) (19 Strand) (19 Strand) (19 Strand) (19 Strand)
Cond.
600V 1000V 600V 1000V 600V 1000V 600V 1000V 600V 1000V

2 21665 21465 21668 21468 21671 21471 21674 21474 21677 21477
3 21666 21466 21669 21469 21672 21472 21675 21475 21678 21478
4 21667 21467 21670 21470 21673 21473 21676 21476 21679 21479

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.85

CSA Control Cable


600V CIC Multi-conductor Cables

No. Cable Weight Insulation Thickness Jacket Thickness Nominal OD


Part
Description of
Number Lbs./
Cond. kg/km Inch mm Inch mm Inch mm
1000 Ft.

14 AWG Stranded (7x22) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22100 2 62 92 .030 .76 .045 1.14 .367 9.32
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22101 3 81 121 .030 .76 .045 1.14 .388 9.86
FT4 Flame Test
22102 4 101 150 .030 .76 .045 1.14 .423 10.74
22103 5 122 182 .030 .76 .045 1.14 .462 11.74
22104 6 143 213 .030 .76 .045 1.14 .504 12.80
22105 7 160 238 .030 .76 .045 1.14 .504 12.80
Rip Cord 22106 8 197 293 .030 .76 .060 1.52 .576 14.63
22107 9 220 327 .030 .76 .060 1.52 .618 15.70
22108 10 226 336 .030 .76 .060 1.52 .669 17.00
22110 12 279 415 .030 .76 .060 1.52 .689 17.50
22114 16 357 531 .030 .76 .060 1.52 .764 19.41
-25°C Installed
-40°C to +90°C (Dry) (75°C Wet) 22118 20 467 695 .030 .76 .080 2.03 .886 22.50

12 AWG Stranded (7x20) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22120 2 82 122 .030 .76 .045 1.14 .405 10.29
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22121 3 109 162 .030 .76 .045 1.14 .429 10.90
FT4 Flame Test
22122 4 140 208 .030 .76 .045 1.14 .469 11.91
22123 5 170 253 .030 .76 .045 1.14 .515 13.08
22124 6 214 319 .030 .76 .060 1.52 .591 15.01
22125 7 240 357 .030 .76 .060 1.52 .591 15.01
Rip Cord 22126 8 270 402 .030 .76 .060 1.52 .639 16.23
22127 9 302 449 .030 .76 .060 1.52 .687 17.45
22128 10 336 500 .030 .76 .060 1.52 .745 18.92
22130 12 390 580 .030 .76 .060 1.52 .768 19.51
22134 16 584 869 .030 .76 .080 2.03 .893 22.68
-25°C Installed
-40°C to +90°C (Dry) (75°C Wet) 22138 20 655 975 .030 .76 .080 2.03 .992 25.20

10 AWG Stranded (7x18) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22140 2 148 220 .030 .76 .045 1.14 .736 18.69
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22141 3 189 281 .030 .76 .045 1.14 .763 19.38
FT4 Flame Test
22142 4 248 369 .030 .76 .060 1.52 .839 21.31
22143 5 293 436 .030 .76 .060 1.52 .891 22.63
22144 6 338 503 .030 .76 .060 1.52 .944 23.98
22145 7 378 563 .030 .76 .060 1.52 .944 23.98
Rip Cord 22146 8 424 631 .030 .76 .060 1.52 .999 25.38
22147 9 469 698 .030 .76 .060 1.52 1.074 27.28
22148 10 548 816 .030 .76 .080 2.03 1.182 30.02
22150 12 631 939 .030 .76 .080 2.03 1.209 30.71
22152 14 717 1067 .030 .76 .080 2.03 1.255 31.88
-25°C Installed
-40°C to +90°C (Dry) (75°C Wet) 22154 16 805 1198 .030 .76 .080 2.03 1.307 33.20
18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.86

CSA Control Cable


600V CIC Multi-conductor Cables

No. Cable Weight Insulation Thickness Jacket Thickness Nominal OD


Part
Description of
Number Cond. Lbs./ kg/km Inch mm Inch mm Inch mm
1000 Ft.

8 AWG Stranded (7x16) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22160 2 240 357 .045 1.14 .060 1.52 .863 21.92
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22161 3 308 458 .045 1.14 .060 1.52 .898 22.81
FT4 Flame Test
22162 4 379 564 .045 1.14 .060 1.52 .957 24.31

Rip Cord

-25°C Installed
-40°C to +90°C (Dry) (75°C Wet)

6 AWG Stranded (7x14) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22170 2 279 415 .060 1.52 .060 1.52 .711 18.06
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22171 3 383 570 .060 1.52 .060 1.52 .756 19.20
FT4 Flame Test

Rip Cord

-25°C Installed
-40°C to +90°C (Dry) (75°C Wet)

4 AWG Stranded (7x12) Bare Copper Conductors


Cross-linked Polyethylene Insulation • Black PVC Jacket (Color Code: Black and Numbered)
CSA C22.2#131, Type CIC 22180 2 390 580 .060 1.52 .060 1.52 .800 20.32
CSA C22.2#0.3, Clause 4.31 Low Acid Gas 22181 3 580 863 .060 1.52 .080 2.03 .891 22.63
FT4 Flame Test

Rip Cord

-25°C Installed
-40°C to +90°C (Dry) (75°C Wet)

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.87

CSA Control Cable


600V ACIC and Teck90 Cables — Overview

Construction Pulling Tensions

Class B stranded bare copper conductors, The combined use of Kellems grips
cross-link polyethylene insulation, bare and pulling eyes is recommended.
copper ground wire, PVC inner jacket,
aluminum steel interlocking armor, PVC
Rip Cord outer jacket. Design Advantages
PVC Inner Jacket ● Galvanized steel interlocking armor
available as an option. Insulation Properties
Interlocked Armor
PVC Outer Jacket XLPE Insulation ● High tensile strength
● Impact- and crush-resistant
Voltage Rating
● Heat-resistant
Introduction 18 to 16 AWG — 600V ACIC
● Excellent elongation
14 to 8 AWG — 600 Volts
Belden® Teck90 and ACIC cables are
● Moisture-resistant
designed to meet demanding industrial 14 to 4/0 AWG — 1000 Volts
needs by combining rugged durability and ● Good low temperature properties
corrosion resistance with flexibility and
easy handling. Temperature Rating Electrical Properties
Teck90 and ACIC Cables are available in ● High insulation resistance
-40°C to 90°C (Dry/Wet)
a wide range of in-stock and custom
● Low dielectric loss
constructions to meet the needs of pulp -25°C installed
and paper, chemical, petroleum and other ● High dielectric strength
demanding industrial and resource industry
environments. They are ideal for use in Application Other Features
wet or dry areas; ventilated, non-ventilated
Teck90 and ACIC are general-purpose ● Corrosion-resistant
or ladder-type cable troughs; ventilated
flexible cableways; and for direct burial. cables used in the pulp and paper, mining, ● Versatile and flexible
petroleum and chemical industries as well
Belden Teck90 Cable is marked with “FT4,” as in commercial buildings. ● Provides cost savings as conduit
“HL” designations, and cable constructions and ducts are not required
are certified to CSA Standard C22.2#131 Teck90 and ACIC may be used under
the following conditions: ● ACIC has a blue jacket
and C22.2#174 for use in a wide range of
hazardous locations. Both inner and outer ● Exposed or concealed wiring ● Rip cord for inner jacket
jackets meet the acid gas evolution in dry or wet conditions
requirement of 14% maximum required by
● In ventilated, non-ventilated or
CSA Standard C22.2#0.3 Clause 4.31. Specifications
ladder-type cable trays in dry
Custom cables are available upon request. or wet conditions ● CSA Standard C22.2#131
● On walls or beams ● CSA Standard C22.2#174
● Directly buried “Cables and Cable Glands for Use
in Hazardous Locations”
● CEC Class I, Division I locations
● CSA Standard C22.2#0.3 Clause 4.31
“Low Acid Gas”
Minimum Bending Radius ● CSA Standard C22.2#0.3 Clause 4.11.4
“Cables with FT4 Marking”
12 times the overall cable diameter 18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.88

CSA Control Cable


600V ACIC Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

18 AWG Stranded (7x26) Bare Copper Conductors • 18 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .030″ (.76mm) XLPE Insulation • PVC Inner Jacket • Blue PVC Outer Jacket
CSA C22.2#239 29030 2 163 243 .32 8.13 .52 13.21 .62 15.75 44 196 7.4 187.96
FT4 Flame Test 29031 3 177 263 .34 8.64 .54 13.72 .64 16.26 66 294 7.6 193.04
29032 4 195 290 .37 9.40 .57 14.48 .67 17.02 88 392 8.0 203.20
29033 5 219 326 .41 10.41 .61 15.49 .71 18.03 110 490 8.5 215.90
29034 6 239 356 .45 11.43 .65 16.51 .75 19.05 132 587 9.0 228.60
29035 7 245 365 .45 11.43 .65 16.51 .75 19.05 154 685 9.0 228.60
Rip Cord 29036 8 266 396 .48 12.19 .68 17.27 .78 19.81 176 783 9.3 236.22
29038 10 331 493 .56 14.22 .76 19.30 .87 22.10 220 979 10.6 269.24
29040 12 353 525 .62 15.75 .82 20.83 .93 23.62 264 1175 11.1 281.94
29043 15 401 597 .65 16.51 .85 21.59 .96 24.38 330 1469 11.5 292.10
29048 20 466 694 .73 18.54 .93 23.62 1.04 26.42 440 1958 12.4 314.96
29053 25 589 877 .79 20.07 1.05 26.67 1.16 29.46 550 2448 13.9 353.06
29058 30 698 1039 .88 22.35 1.14 28.96 1.25 31.75 660 2937 15.0 381.00
29068 40 827 1231 .97 24.64 1.23 31.24 1.35 34.29 880 3916 16.2 411.48
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas 29078 50 965 1436 1.09 27.69 1.35 34.29 1.47 37.34 1100 4895 17.6 447.04

16 AWG Stranded (7x24) Bare Copper Conductors • 16 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .030″ (.76mm) XLPE Insulation • PVC Inner Jacket • Blue PVC Outer Jacket
CSA C22.2#239 29017 2 202 301 .34 8.64 .54 13.72 .65 16.51 70 312 7.7 195.58
FT4 Flame Test 29004 3 221 329 .36 9.14 .56 14.22 .66 16.76 105 467 7.9 200.66
29018 4 242 360 .39 9.91 .59 14.99 .70 17.78 140 623 8.3 210.82
29019 5 264 393 .42 10.67 .62 15.75 .73 18.54 175 779 8.6 218.44
29005 6 292 435 .46 11.68 .66 16.76 .77 19.56 210 935 9.1 231.14
29020 7 314 467 .47 11.94 .67 17.02 .77 19.56 245 1090 9.2 233.68
Rip Cord 29021 8 364 542 .50 12.70 .70 17.78 .80 20.32 280 1246 9.6 243.84
29022 10 412 613 .61 15.49 .81 20.57 .92 23.37 350 1558 10.9 276.86
29006 12 441 656 .63 16.00 .83 21.08 .94 23.88 420 1869 11.2 284.48
29023 15 502 748 .68 17.27 .88 22.35 1.00 25.40 525 2336 11.9 302.26
29007 20 636 947 .77 19.56 1.03 26.16 1.13 28.70 700 3115 13.7 347.98
29024 25 845 1258 .89 22.61 1.15 29.21 1.26 32.00 875 3894 15.1 383.54
29008 30 922 1372 .94 23.88 1.20 30.48 1.30 33.02 1050 4673 15.8 401.32
29009 40 1109 1650 1.06 26.92 1.32 33.53 1.41 35.81 1400 6230 17.3 439.42
29016 50 1306 1944 1.19 30.23 1.45 36.83 1.54 39.12 1750 7788 18.8 477.52
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas 29025 60 1390 2070 1.27 32.26 1.53 38.86 1.66 42.16 2100 9345 19.9 505.46
XLPE = Cross-linked Polyethylene
Color Code: #1 conductor is white; remaining conductors are black with number coding. Other color codes available upon request.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.89

CSA Control Cable


600V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

14 AWG Stranded (7x22) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .030″ (.76mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5500 2 198 296 .36 9.14 .56 14.22 .66 16.76 108 481 7.8 198.12
FT4 Flame Test C5501 3 222 331 .39 9.91 .58 14.73 .66 16.76 162 721 8.2 208.28
C5502 4 251 375 .42 10.67 .62 15.75 .71 18.03 216 961 8.5 215.90
C5503 5 284 424 .47 11.94 .66 16.76 .74 18.80 270 1202 9.0 228.60
C5504 6 317 473 .51 12.95 .70 17.78 .78 19.81 324 1442 9.5 241.30
C5505 7 331 494 .51 12.95 .70 17.78 .78 19.81 378 1682 9.5 241.30
Rip Cord C5506 8 414 618 .58 14.73 .77 19.56 .86 21.84 432 1922 10.4 264.16
C5508 10 510 761 .67 17.02 .93 23.62 .95 24.13 540 2403 12.3 312.42
C5510 12 551 822 .69 17.53 .95 24.13 .97 24.64 648 2884 12.6 320.04
C5513 15 636 949 .77 19.56 1.03 26.16 1.11 28.19 810 3605 14.1 358.14
C5518 20 810 1209 .90 22.86 1.16 29.46 1.24 31.50 1080 4806 15.1 383.54
C5523 25 948 1415 .90 22.86 1.24 31.50 1.33 33.78 1350 6008 16.1 408.94
C5528 30 1047 1563 1.05 26.67 1.30 33.02 1.40 35.56 1620 7209 16.8 426.72
C5529 40 1310 1955 1.20 30.48 1.42 36.07 1.51 38.35 2160 9612 18.3 464.82
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas C6064 50 1620 2418 1.35 34.29 1.60 40.64 1.66 42.16 2700 12015 20.5 520.70

12 AWG Stranded (7x20) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .030″ (.76mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5530 2 225 336 .41 10.41 .60 15.24 .69 17.53 172 765 8.3 210.82
FT4 Flame Test C5531 3 261 390 .43 10.92 .62 15.75 .70 17.78 258 1148 8.6 218.44
C5532 4 301 449 .47 11.94 .66 16.76 .73 18.54 344 1531 9.1 231.14
C5533 5 348 519 .52 13.21 .71 18.03 .78 19.81 430 1914 9.1 231.14
C5534 6 435 649 .59 14.99 .78 19.81 .86 21.84 516 2296 10.5 266.70
C5535 7 450 672 .59 14.99 .78 19.81 .86 21.84 602 2679 10.5 266.70
Rip Cord C5536 8 506 755 .64 16.26 .83 21.08 .92 23.37 688 3062 11.1 281.94
C5538 10 633 945 .75 19.05 1.01 25.65 1.02 25.91 860 3827 13.3 337.82
C5540 12 696 1039 .77 19.56 1.03 26.16 1.12 28.45 1032 4592 13.5 342.90
C5543 15 823 1228 .90 22.86 1.16 29.46 1.24 31.50 1290 5741 15.1 383.54
C5548 20 1035 1545 .99 25.15 1.25 31.75 1.34 34.04 1720 7654 16.5 419.10
C5553 25 1230 1836 1.10 27.94 1.36 34.54 1.45 36.83 2150 9568 17.6 447.04
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas C5558 30 1390 2075 1.20 30.48 1.46 37.08 1.51 38.35 2580 11481 17.6 447.04
XLPE = Cross-linked Polyethylene
Color Code: 2 conductors — Black, White (If required, a Red conductor can be used in place of White.)
3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
4 conductors — Black, Red, Blue, White
5 or more conductors — Black and numbered

18 • Industrial Cables

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.90

CSA Control Cable


600V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

10 AWG Stranded (7x18) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .030″ (.76mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5560 2 278 415 .48 12.19 .66 16.76 .72 18.29 296 1317 8.9 226.06
FT4 Flame Test C5561 3 327 488 .50 12.70 .70 17.78 .75 19.05 444 1976 9.2 233.68
C5562 4 405 604 .57 14.48 .77 19.56 .79 20.07 592 2634 10.1 256.64
C5563 5 487 727 .63 16.00 .83 21.08 .93 23.62 740 3293 11.5 292.10
C5564 6 556 830 .68 17.27 .88 22.35 .93 23.62 888 3952 11.5 292.10
C5565 7 627 936 .69 17.53 .89 22.61 .99 25.15 1036 4610 11.8 299.72
Rip Cord C5566 8 739 1103 .74 18.80 .94 23.88 1.00 25.40 1184 5269 12.4 314.96
C5568 10 964 1439 .84 21.34 1.10 27.94 1.24 31.50 1480 6586 14.4 365.76
C5570 12 1067 1593 .93 23.62 1.19 30.23 1.26 32.00 1776 7903 15.6 396.24
C5573 15 1297 1936 .99 25.15 1.25 31.75 1.37 34.80 2220 9879 16.3 414.02
C5578 20 1546 2307 1.13 28.70 1.39 35.31 1.47 37.34 2960 13172 16.9 429.26
C5579 25 1802 2690 1.26 32.00 1.52 38.61 1.60 40.64 3700 16465 19.7 500.38
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas C5580 30 2142 3197 1.34 34.04 1.60 40.64 1.66 42.16 4440 19758 20.6 523.24

8 AWG Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .045″ (1.14mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5583 2 407 607 .59 14.99 .78 19.81 .86 21.84 384 1709 10.6 269.24
FT4 Flame Test C5581 3 471 703 .63 16.00 .83 21.08 .90 22.86 576 2563 10.8 274.32
C5582 4 606 904 .69 17.53 .89 22.61 .97 24.64 768 3418 12.5 317.50

Rip Cord

Dual Rated 600V, 1000V


HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas
XLPE = Cross-linked Polyethylene
Color Code: 2 conductors — Black, White (If required, a Red conductor can be used in place of White.)
3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
4 conductors — Black, Red, Blue, White
5 or more conductors — Black and numbered

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.91

CSA Control Cable


600V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

Composite 14 AWG Stranded (7x22) and 12 AWG Stranded (7x20) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .031″ (.79mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6054 3c/14 369 549 .560 14.22 .75 19.05 .89 22.61 424 1886 8.4 213.36
FT4 Flame Test 3c/12

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG Stranded (7x22) and 10 AWG Stranded (7x18) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .031″ (.79mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6051 3c/14 432 643 .600 15.24 .82 20.83 .92 23.37 608 2705 9.0 228.60
FT4 Flame Test 3c/10

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG Stranded (7x22) and 8 AWG Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .046″ (1.17mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6059 3c/14 608 905 .700 17.78 .89 22.51 .98 24.92 1160 5160 9.8 248.92
FT4 Flame Test 3c/8

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

Composite 14 AWG Stranded (7x22) and 6 AWG Stranded (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .061″ (1.55mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6060 3c/14 849 1264 .810 20.57 1.06 27.00 1.16 29.41 1700 7562 11.6 294.64
FT4 Flame Test 3c/6

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas
XLPE = Cross-linked Polyethylene
Color Code: 2 conductors — Black, White (If required, a Red conductor can be used in place of White.)
3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
18 • Industrial Cables

4 conductors — Black, Red, Blue, White


5 or more conductors — Black and numbered

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.92

CSA Control Cable


1000V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

14 AWG Stranded (7x22) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .045″ (1.14mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5701 3 251 374 .47 11.94 .67 17.02 .73 18.54 162 721 9.2 233.68
FT4 Flame Test C5702 4 301 448 .51 12.95 .71 18.03 .81 20.57 216 961 9.7 246.38

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

12 AWG Stranded (7x20) Bare Copper Conductors • 14 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .045″ (1.14mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5730 2 253 377 .48 12.19 .68 17.27 .74 18.80 172 765 9.3 236.22
FT4 Flame Test C5731 3 291 433 .51 12.95 .71 18.03 .76 19.30 258 1148 9.7 246.38
C5732 4 368 548 .59 14.99 .75 19.05 .85 21.59 344 1531 10.8 274.32

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

10 AWG Stranded (7x18) Bare Copper Conductors • 12 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .045″ (1.14mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5760 2 285 424 .56 14.22 .79 19.99 .70 17.71 296 1317 10.3 261.62
FT4 Flame Test C5761 3 389 581 .59 14.99 .79 20.07 .85 21.59 444 1976 10.3 261.62
C5762 4 460 687 .65 16.51 .85 21.59 .90 22.86 592 2634 11.5 292.10

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

8 AWG Stranded (7x16) Bare Copper Conductors • 10 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .045″ (1.14mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5583 2 407 607 .59 14.99 .78 19.81 .86 21.84 384 1709 10.6 269.24
FT4 Flame Test C5581 3 471 703 .63 16.00 .83 21.08 .90 22.86 576 2563 10.8 274.32
C5582 4 606 905 .69 17.53 .89 22.61 .97 24.64 768 3418 12.5 317.50

Rip Cord

Dual Rated 600V, 1000V


HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas
XLPE = Cross-linked Polyethylene
Color Code: 2 conductors — Black, White (If required, a Red conductor can be used in place of White.)
3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
4 conductors — Black, Red, Blue, White
5 or more conductors — Black and numbered

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.93

CSA Control Cable


1000V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

6 AWG Stranded (7x14) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .060″ (1.53mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5590 2 567 844 .73 18.54 .99 25.15 1.10 27.94 610 2713 12.8 325.12
FT4 Flame Test C5591 3 685 1019 .78 19.81 1.04 26.42 1.15 29.21 915 4072 13.4 340.36
C5592 4 927 1380 .89 22.61 1.15 29.21 1.24 31.50 1220 5429 14.9 378.46

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

4 AWG Stranded (7x12) Bare Copper Conductors • 8 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .060″ (1.53mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5601 3 961 1430 .91 23.11 1.17 29.72 1.23 31.24 1455 6475 15.2 386.08
FT4 Flame Test C5602 4 1202 1794 .91 23.11 1.25 31.75 1.33 33.78 1940 8633 16.2 411.48

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

3 AWG Stranded (7x11) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .060″ (1.53mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5611 3 1126 1681 .97 24.64 1.23 31.24 1.30 33.02 1836 8170 15.8 401.32
FT4 Flame Test

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

2 AWG Stranded (7x10) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .060″ (1.53mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5621 3 1291 1927 1.02 25.91 1.28 32.51 1.37 34.80 2316 10302 16.5 419.10
FT4 Flame Test C5622 4 1691 2524 1.12 28.45 1.38 35.05 1.48 37.59 3088 13736 17.7 449.58

Rip Cord

HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas
XLPE = Cross-linked Polyethylene
18 • Industrial Cables

Color Code: 2 conductors — Black, White (If required, a Red conductor can be used in place of White.)
3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
4 conductors — Black, Red, Blue, White

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.94

CSA Control Cable


1000V Teck90 Cables

Maximum Minimum
No. Cable Weight Inner Jacket OD Armor OD Outer Jacket
Part Pull Tension Bend Radius
Description of
No. Cond. Lbs./ kg/km Inch mm Inch mm Inch mm Lbs. N Inch mm
1000 Ft.

1 AWG Stranded (19x14) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .080″ (2.03mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5625 3 1620 2411 1.25 31.75 1.51 38.35 1.59 40.39 1980 8807 19.1 485.14
FT4 Flame Test C5626 4 2173 3234 1.34 34.04 1.57 39.88 1.68 42.67 2680 11921 20.2 513.08

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

1/0 AWG Stranded (19x12) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .080″ (2.03mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5627 3 1912 2854 1.34 34.04 1.60 40.64 1.67 42.42 3582 15940 20.0 508.0
FT4 Flame Test 6164 4 2514 3742 1.44 36.58 1.67 42.42 1.78 45.21 4700 20906 21.4 543.56

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

2/0 AWG Stranded (19x11) Bare Copper Conductors • 6 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .080″ (2.03mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 C5635 3 2300 3423 1.40 35.56 1.63 41.40 1.74 44.20 4200 12010 20.9 530.86
FT4 Flame Test 6157 4 3039 4523 1.55 39.37 1.84 46.74 1.95 49.53 5500 24465 23.4 594.36

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

3/0 AWG Stranded (19x10) Bare Copper Conductors • 4 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .080″ (2.03mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6163 3 2905 4324 1.51 38.10 1.80 45.72 1.91 48.26 5020 11121 22.9 579.12
FT4 Flame Test 6179 4 3700 5506 1.67 42.42 1.96 49.78 2.07 52.58 6500 28913 24.8 629.92

Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas

4/0 AWG Stranded (19x9.5) Bare Copper Conductors • 4 AWG Bare Copper Ground Wire
Aluminum Interlocked Armor • .080″ (2.03mm) XLPE Insulation • PVC Inner Jacket • Black PVC Outer Jacket
CSA C22.2#131 6193 3 3450 5134 1.63 41.40 1.92 48.77 2.03 51.56 6650 29580 24.4 619.76
FT4 Flame Test

\
Rip Cord
HAZ LOC
CSA C22.2#0.3 Clause 4.31 Low Acid Gas
XLPE = Cross-linked Polyethylene
Color Code: 3 conductors — Black, Red, Blue (If required, a White conductor can be used in place of Blue.)
4 conductors — Black, Red, Blue, White

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.95

CSA Control Cable


1000V Variable Frequency Drive Cable

Cable Specifications
Part
Description AWG Stranding Shield
● CSA C22.2 #38 Type TC Number

● CSA C22.2 #230 Type TC


14 to 2 AWG (3) Stranded Bare Copper Circuit Conductors + (1) Full-sized PVC Insulated
● CSA FT4 70,000 BTU Flame Test Ground • Overall Beldfoil® (100% Coverage) + TC Braid Shield (85% Coverage) • Full Size
TC Drain Wire (ICEA Method 4 Color Code: Black and Numbered, Green/Yellow Ground)
● 90°C Dry and Wet
XLPE Insulation • Black Sunlight- and Oil-resistant PVC Jacket
● -40°C Cold Bend, -25°C Cold Impact 1000V CSA TC 29550 14 7 Beldfoil

FT4 29551 12 7 (100% Coverage)
-25°C Installation temp
RW90 Circuit Conductors + TC Braid
29552 10 7
● Per CEC Part 1, Suitable for Use (85% Coverage)
29553 8 7
in Hazardous Locations:
Class 1 — Zone 2 29554 6 7
Class 2 — Division 2 Drain Wire 29555 4 7

29556 2 7
Sunlight Resistant/UV Resistant
● Direct Burial 1 to 4/0 AWG (3) Stranded Bare Copper Circuit Conductors +
(3) Symmetrical Bare Copper Grounds • (2) Spiral Copper Tape Shields
XLPE Insulation • Black Sunlight- and Oil-resistant PVC Jacket
14 to 2 AWG with Foil/Braid Shield
1000V CSA TC 29557 1 19 (2) Spiral
Belden’s classic line of VFD cables, with FT4 Copper Tapes
29558 1/0 19
foil/braid shield, is offered in 14 to 2 AWG, XHHW-2 Circuit Conductors
and continues to be the highest-performing 29559 2/0 19
solution in the market. The oversized XLPE 29560 3/0 19
insulation provides the lowest capacitance 29561 4/0 19
available in a VFD cable. Its highly effective
dual shielding provides the lowest resistance Products listed are subject to minimum order quantities.
to ground path, which improves common
mode current containment. Included are a
full-size, insulated green ground wire with
a yellow stripe, as well as a drain wire for
ease of installation and termination. The
85% braid coverage offers optimum EMI
low frequency noise protection, while the
100% aluminum/Mylar tape offers RFI high
frequency noise protection. Cables are
round and smooth for proper sealing of
glands and molding applications.

Large AWG (1 to 4/0) with Copper


Tape Shield, Symmetrical Design
Belden’s symmetrical design combines the
benefits of our classic line of VFD cables,
with additional features for use on larger,
more powerful AC motor drives. Its highly
effective shielding provides a low resistance
ground path, which improves common mode
current containment. The spirally applied
dual copper tapes provide improved flexibility
and EMI/RFI noise protection. Three
symmetrical bare ground wires provide a
balanced ground system. This reduces the
likelihood of premature motor bearing or
18 • Industrial Cables

motor insulation failure.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.96

Technical Information
Gland Information for Armored Cables

Thomas and Betts Hawke


Standard Seal 1348 Alternative Seal 1498
Range Over Jacket Hawke
Part Hub Size Diameter Diameter NPT
Size
No. NPT Minimum Maximum Minimum Maximum Minimum Maximum Size
Ref.
Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
ST050-462 1/2 .525 13.34 .650 16.51 711-A .590 14.99 .820 20.83 .470 11.94 .610 15.49 1/2
ST050-464 1/2 .600 15.24 .760 19.30 711-B .790 20.07 .060 26.92 .630 16.00 .840 21.34 3/4
ST050-465 1/2 .725 18.42 .885 22.48 711-C .930 23.62 1.310 33.27 .830 21.08 1.090 27.69 1
ST050-466 1/2 .825 20.96 .985 25.02 711-C2 1.260 32.00 1.690 42.93 1.100 27.94 1.340 34.04 1-1/4
ST075-467 3/4 .880 22.35 1.065 27.05 711-D 1.690 42.93 2.060 52.32 1.300 33.02 1.610 40.89 2
ST075-468 3/4 1.025 26.04 1.205 30.61 711-E 2.050 52.07 2.560 65.02 1.810 45.97 2.160 54.86 2-1/2
ST100-469 1 1.187 30.15 1.375 34.93 711-F 2.560 65.02 3.070 77.98 2.240 56.90 2.640 67.06 3
ST125-470 1-1/4 1.350 34.29 1.625 41.28 711-H 2.990 75.95 3.520 89.41 Special Order 3-1/2
ST125-550 1-1/4 1.500 38.10 1.625 41.28 711-J 3.500 88.90 4.110 104.39 Special Order 4
ST125-471 1-1/4 1.600 40.64 1.875 47.63
ST150-472 1-1/2 1.700 43.18 1.965 49.91 Adalet — PLM
ST150-473 1-1/2 1.900 48.26 2.187 55.55
ST200-551 2 1.900 48.26 2.187 55.55 Diameter Over Jacket
Part Conduit
ST200-474 2 2.100 53.34 2.375 60.33 Minimum Maximum
No.** Size
ST200-475 2 2.300 58.42 2.565 65.15 Inch mm Inch mm
ST200-476 2 2.500 63.50 2.750 69.85 PS/PSX 45-05 .350 8.89 .450 11.43 1/2
ST250-477 2-1/2 2.380 60.45 2.640 67.06 PS/PSX 55-05 .450 11.43 .550 13.97 1/2
ST250-478 2-1/2 2.580 65.53 2.840 72.14 PS/PSX 65-05 .550 13.97 .650 16.51 1/2
ST300-479 3 2.790 70.87 3.060 77.72 PS/PSX 75-05 .650 16.51 .750 19.05 1/2
ST300-480 3 3.000 76.20 3.270 83.06 PS/PSX 85-05 .750 19.05 .850 21.59 1/2
ST300-481 3 3.210 81.53 3.480 88.39 PS/PSX 95-05 .850 21.59 .950 24.13 1/2
ST350-482 3-1/2 3.420 86.67 3.690 93.73 PS/PSX 99-07 .850 21.59 .990 25.15 3/4
ST350-483 3-1/2 3.610 91.69 3.870 98.30 PS/PSX 107-07 .920 23.37 1.070 27.18 3/4
ST400-484 4 3.810 96.77 4.030 102.36 PS/PSX 113-07 .980 24.89 1.130 28.70 3/4
ST400-485 4 3.965 100.71 4.185 106.30 PS/PSX 121-07 1.070 27.18 1.210 30.73 3/4
ST400-486 4 4.120 104.65 4.340 110.24 PS/PSX 112-10 1.000 25.40 1.120 28.45 1
PS/PSX 125-10 1.120 28.45 1.250 31.25 1
PS/PSX 138-10 1.220 30.99 1.380 35.05 1
Crouse Hinds PS/PSX 138-12 1.280 32.51 1.380 35.05 1-1/4
PS/PSX 156-12 1.380 35.05 1.560 39.62 1-1/4
NPT Armor PS/PSX 174-12 1.560 39.62 1.740 44.20 1-1/4
Non-Hazardous Hazardous
Thread OD Range PS/PSX 188-12 1.740 44.20 1.880 47.75 1-1/4
Part No. Part No.
Size (Inch)
PS/PSX 174-15 1.600 40.64 1.740 44.20 1-1/2
1/2 .440 to .650 TMC165 TMCX165* PS/PSX 188-15 1.740 44.20 1.880 47.75 1-1/2
3/4 .600 to .850 TMC285 TMCX285* PS/PSX 200-15 1.880 47.75 2.000 50.80 1-1/2
1 .800 to 1.120 TMC3112 TMCX3112* PS/PSX 218-15 2.000 50.80 2.180 55.37 1-1/2
1-1/4 1.100 to 1.400 TMC4140 TMCX4140* PS/PSX 219-20 2.050 52.07 2.190 55.63 2
1-1/2 1.330 to 1.610 TMC5161 TMCX5161* PS/PSX 236-20 2.190 55.63 2.360 59.94 2
2 1.570 to 2.060 TMC6206 TMCX6206* PS/PSX 247-20 2.350 59.69 2.470 62.74 2
2-1/2 1.930 to 2.470 TMC7247 TMCX7247* PS/PSX 261-20 2.470 62.74 2.610 66.29 2
3 2.450 to 3.020 TMC8302 TMCX8302 PS/PSX 263-25 2.460 62.48 2.630 66.80 2-1/2
3-1/2 2.950 to 3.520 TMC9352 TMCX9352 PS/PSX 280-25 2.620 66.55 2.800 71.12 2-1/2
4 3.500 to 4.020 TMC10402 TMCX10402 PS/PSX 296-25 2.800 71.12 2.960 75.18 2-1/2
*TMCX Catalog numbers listed are suitable for use with Type TC tray cable in hazardous locations PS/PSX 297-30 2.800 71.12 2.970 75.44 3
when installed in accordance with NEC Articles 501-5(e) and 502-5. TMCX series is not suitable PS/PSX 311-30 2.950 74.93 3.110 78.99 3
for use in Class III locations when used with tray cable.
PS/PSX 327-30 3.100 78.74 3.270 83.06 3
PS/PSX 343-30 3.260 82.80 3.430 87.12 3
PS/PSX 359-30 3.420 86.87 3.590 91.19 3
PS/PSX 375-35 3.520 89.41 3.750 95.25 3-1/2
PS/PSX 392-35 3.750 95.25 3.920 99.57 3-1/2
PS/PSX 412-35 3.900 99.06 4.120 104.65 3-1/2
PS/PSX 423-40 4.050 102.87 4.230 107.44 4
PS/PSX 437-40 4.200 106.68 4.370 111.00 4
PS/PSX 451-40 4.340 110.24 4.510 114.55 4
PS/PSX 462-40 4.430 112.52 4.620 117.35 4
**Use PS for non-hazardous locations and PSX for hazardous locations.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.97

Technical Information
LSZH Jacketed Cables and Hazardous Locations Reference

Approvals and Standards/Performance Data Low-Smoke, Zero-Halogen


for Low-Smoke, Zero-Halogen Jacketed Cable Jacketed Cable Specifications

600V, 90°C TC-LS


XLPE Insulation Haloarrest® Jacket
NEC 340/UL 1277 & 1685
Physical: (per UL-44) Physical
Tensile (min) 1500 psi Tensile (min) 1500 psi Instrumentation
● 18 to 12 AWG, BC or TC
Elongation (min) 150% Elongation (min) 100%
● 90°C XLPE insulation
Deformation (max) 3.35 Tear resistance 74 lbs/inch
LOI 27 ● UL 44 XHHW-2 — 90°C dry/wet
LOI 38
Halogen Content ● Shielded or unshielded

IEC 754-1 0% ● Haloarrest jacket

BS6425 0% Control or Power


MIL-C-24643 <0.2% ● 14 to 4/0 AWG, BC or TC
NBS Smoke Chamber (.100″ wall) ● 90°C XLPE insulation
Flaming Mode 141 Dm corrected typical ● UL 44 XHHW-2 — 90°C dry/wet
Smoldering Mode 311 Dm corrected typical ● Shielded or unshielded
Acid Gas ● Haloarrest jacket
IEC 754-2 4.3 pH, 28 µS/cm
VDE 0472 Part 813 4.3 pH, 27 µS/cm
Toxicity Index
NES 713 1

Hazardous Locations Cable Reference

Article 500 Class II Division 1 Article 504


Class I Division 1 Hazards ● Locations where combustible dusts Intrinsically Safe

exist under normal conditions. ●
Locations where flammable gases Equipment and wiring that are incapable
or vapors may exist under normal ● Use conduit or MI with approved of releasing sufficient electrical energy
operating conditions, under frequent termination fittings. under normal or abnormal conditions to
repair or maintenance operations, cause ignition of a specific hazardous
or where breakdown or faulty Class II Division 2 atmospheric mixture in its most easily
operation of process equipment ignited concentration.
● Locations where combustible dusts
might also cause simultaneous failure ●
exist under abnormal conditions. Use CL3, CL2, PLTC, TC or CM cable,
of electrical equipment.
colored light blue, with approved sealing
● Use conduit or PLTC, ITC, TC, MC
● Use conduit or MI cable with and separation.
with ventilated channel cable trays.
approved termination fittings.
● Use conduit or MC, MI with
Class I Division 2 Hazards approved termination fittings. Hazardous Location Cable
Reference per Canadian Electrical
● Locations where flammable gases, Code CEC Section 18
Class III Division 1
vapors or volatile liquids are handled
either in a closed system, or confined ● Locations where easily ignitible All Armored cables printed “HL” per
within suitable enclosures, or where fibers and flyings exist under CSA C22.2 #174 are rated for all
hazardous concentrations are normally normal conditions. Hazardous Location Classes and Divisions
prevented by positive mechanical (ie. Class 1, Div. 1).
● Use conduit or MC, MI with
ventilation. Areas adjacent to Division 1
approved termination fittings.
areas belong in Division 2. All Tray Cables printed “TC” per per

CSA C22.2 #230 are rated for all
Use PLTC, ITC, TC, MC, MV, MI Class III Division 2
18 • Industrial Cables

Hazardous Location Classes and Division 2


with approved termination fittings.
● Locations where easily ignitible or lower. (ie. Class 1, Div. 2 or lower).
fibers and flyings exist under
abnormal conditions.
● Use conduit or MC, MI with
approved termination fittings.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.98

Technical Information

UL Approved Insulation/Jacketing Options

UL Listed for MC and TC UL Listed for PLTC


Max. Temp Rating
Insulation/Jacket Flame Tests Insulation/Jacket Max. Temp Rating
Wet Dry
PVC-Nylon/PVC 75°C 90°C UL 1685 XLPE/PVC 90°C
(THHN or THWN) FT4/
14 AWG & larger IEEE 1202/383 XLPE/CPE 90°C
ICEA T-29-520 PVC/PVC 105°C
PVC-Nylon/PVC NA 90°C UL 1685 PVC/CPE 105°C
(TFN or TFFN) FT4/
16 & 18 AWG IEEE 1202/383 PE/PVC 75°C
ICEA T-29-520 FPE/PVC 75°C
XLPE/PVC or CPE 90°C 90°C UL 1685 TPE/TPE 105°C
(XHHW–2) FT4/
14 AWG & larger IEEE 1202/383 XLPE/Haloarrest® 90°C
VW-1 rated singles FEP/FEP 200°C
ICEA T-29-520
XLPE/PVC or CPE 75°C 75°C UL 1685
(RFH–2) FT4/
16 & 18 AWG IEEE 1202/383
VW-1 rated singles
ICEA T-29-520 Abbreviations Key
FRPO/PVC — 75°C UL 1685 CPE Chlorinated Polyethylene
18 AWG & larger
FEP Fluorinated Ethylene-propylene
TPE/TPE 75°C 90°C UL 1685
FRPO/PVC 75°C 90°C UL 1685 FPE Foam Polyethylene

XLPE/Haloarrest 90°C 90°C UL 1685 FRPO Flame-Retardant Polyolefin


(XHHW-2) FT4/IEEE 1202/383 PE Polyethylene
14 AWG & larger ICEA T-29-520
PVC Polyvinyl Chloride
XLPE/Haloarrest 75°C 75°C UL 1685
Nylon insulated singles are type THHN or THWN for conductors 14 AWG or larg-
(RFH-2) FT4/IEEE 1202/383
16 & 18 AWG ICEA T-29-520 er. Conductor sizes 16 and 18 AWG are Type TFN or TFFN singles.

FEP/PVC 90°C 90°C UL 1685 TPE Thermoplastic Elastomer


XLPE Cross-Linked Polyethylene
Cross-Linked Polyethylene (XLPE) insulated singles are type XHHW-2
for conductors 14 AWG or larger. Conductor sizes 16 and 18 AWG are RFH-2.

Vertical Tray Flame Test Comparison

FT4/IEEE 1202/
Test UL-1685 (UL-1581) IEEE 383-1974 IEC 323-3 ICEA T-29-520
IEEE 383-2003
Flame Test Chamber Vertical Tray Vertical Tray Vertical Tray Vertical Tray Vertical Tray
Burner Type Ribbon gas burner Ribbon gas burner Ribbon gas burner Ribbon gas burner Ribbon gas burner
Theoretical Heat Input 70,000 BTU/hr 70,000 BTU/hr 70,000 BTU/hr 70,000 BTU/hr 210,000 BTU/hr
Burner Positioning horizontal 3″ 20° up from horizontal 3″ horizontal horizontal 8-1/4″
from samples horizontal 2.95″ from samples 2.95″ from from cable surface
from cable surface 18″ above cable surface 12-1/4″ above
18″ from tray base 11.8" above floor tray bottom 23.6″ above floor tray base
Tray Dimensions 8′ length 9.84′ length 8′ length 11.5′ length 8′ length
12″ width 11.81″ width 12″ width 19.7″ width 12″ width
3″ side flanges 2.85″ side flanges 3″ side flanges none 3″ side flanges
Sample Spacing 1/2 cable diameter 1/2 cable diameter 1/2 cable diameter lesser of 1/2 cable 1/2 cable diameter
diameter and .78″
Duration of 20 minutes 20 minutes 20 minutes 20 minutes 20 minutes
Flame Application
Mode of Failure Cable blistering or Cable char has Cable blistering or Cable charring has Cable blistering or
charring has reached exceeded a length charring has reached reached a height of charring has reached
the top of the sample of 4.92′. the top of the sample 98.4″ above the the top of the sample
after the cable has after the cable has bottom of the burner. after the cable has
self-extinguished. self-extinguished. self-extinguished.

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m