0% found this document useful (0 votes)
37 views2 pages

Encoder Syemen

The document provides original instructions for the GP46 Pressure Gauge with Switch, detailing safety instructions, specifications, installation procedures, and settings for the limit gauge indicator. It emphasizes the importance of proper handling, installation, and maintenance to prevent malfunctions and ensure accurate pressure readings. Additionally, it includes warnings about environmental conditions and disposal guidelines for the product.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

Encoder Syemen

The document provides original instructions for the GP46 Pressure Gauge with Switch, detailing safety instructions, specifications, installation procedures, and settings for the limit gauge indicator. It emphasizes the importance of proper handling, installation, and maintenance to prevent malfunctions and ensure accurate pressure readings. Additionally, it includes warnings about environmental conditions and disposal guidelines for the product.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

GP46-SMY13EN

2 Specification - continued 3 Installation - continued 4 Settings


ORIGINAL INSTRUCTIONS
Note 1) When mounting a pressure gauge, use caution not to tighten 3.5 Piping 4..1 Procedure for Setting the Limit Gauge Indicator
excessively. Excessive tightening will cause product to be damaged. Use 4.1.1. Before setting the (green) limit indicator, turn the cover counter
Caution
Refer to Declaration of a pipe tape for sealing.
clockwise (approximately 6 to 7 mm) until it stops. Then, remove by
Note 2) Water is not an acceptable fluid. When using the other fluids, • Before connecting piping make sure to clean up chips, cutting oil, dust
Conformity for relevant pulling it towards you.
Instruction Manual etc.
Directives please consult with SMC for compatibility information concerning
• When installing piping or fittings, ensure sealant material does not
[option] corrosion.
enter inside the port. When using seal tape, leave 1.5 - 2 threads
GP46 Note 3) Set value of pressure switch is indicated by pointer (green). This exposed on the end of the pipe/fitting.
Pressure Gauge with Switch indicates the position from ON to OFF when the pressure drops in the • Tighten fittings to the specified tightening torque below.
connection between N.O. (white line) and COM (black line). To set the Connection thread size Tightening torque (N・m)
value, turn needle in clockwise position to the correct value. When
setting; if desired set position has been passed, turn needle in a counter- R1/8 7-9
clockwise direction back again beyond the desired value and then once
again return needle in a clockwise direction stopping at the desired value. R1/4 12-14
Value must be set while needle is traveling in a clockwise direction.
Note 4) Make sure to provide a minimum difference of 0.1 MPa between
the set pressure and the operating pressure (including the pressure 4.1.2. Use a flat head screwdriver (with a 2.9 mm blade width) to set the
drop). If the difference is smaller, it could lead to improper operation. 3.6 Lubrication
The intended use of this product is to indicate the pressure in the (green) limit indicator. Be careful not to bend the other needle or damage
The working pressure should be the pressure that adds the set needle Caution the dial plate.
pneumatic system.
error (0.03MPa), hysteresis (0.07MPa), and display accuracy of the set • SMC products have been lubricated for life at manufacture, and do not
1 Safety Instructions pressure value (±0.05MPa). If accuracy is not taken into consideration,
require lubrication in service.
the connection between N.O. (white) and COM (black) may not turn on
These safety instructions are intended to prevent hazardous situations
when the pressure rises. • If a lubricant is used in the system, refer to catalogue for details.
and/or equipment damage. These instructions indicate the level of 3.7 Circuit Diagram
potential hazard with the labels of “Caution,” “Warning” or “Danger.” Note 5) Maximum error value: Add the pressure gauge indicator error of
0.03 MPa to the setting needle error. Without indicator light
They are all important notes for safety and must be followed in addition
to International Standards (ISO/IEC) *1), and other safety regulations. Note 6) Avoid freezing as this may cause a malfunction.
*1)
ISO 4414: Pneumatic fluid power - General rules relating to systems. Note 7) The guaranteed temperature range for accuracy is 23°C ±5°C.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of machines.
(Part 1: General requirements) Warning
ISO 10218-1: Manipulating industrial robots -Safety. etc.
Special products might have specifications different from those shown in 4.1.3. After completing the setting, replace the cover. Fit the cover by
• Refer to product catalogue, Operation Manual and Handling this section. Contact SMC for specific drawings. aligning the cut out in the cover to the groove on the top of the black case.
Precautions for SMC Products for additional information.
Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make
• Keep this manual in a safe place for future reference.
3 Installation sure that the matching mark on the cover is aligned with the groove on
3.1 Installation the top of the case.
With indicator light
Warning
• Do not install the product unless the safety instructions have been read

Caution indicates a hazard with a low level of risk which, if and understood.
Caution
not avoided, could result in minor or moderate injury. • Do not apply pressure over the max. value of the scale as it will lead
to operation failure.
Warning indicates a hazard with a medium level of risk • The maximum frequency of use is 6 times/minute.
Warning
which, if not avoided, could result in death or serious injury. If there is a pulsation of pressure, it will break in a short period of time.
Danger indicates a hazard with a high level of risk which, if
Danger 3.2 Selection
not avoided, will result in death or serious injury.
Caution
Warning
• Always ensure compliance with relevant safety laws and • Make sure that no direct impact or vibrations are applied to the body. 4.2 Procedure for Setting the Limit Gauge Indicator (Color Zone
standards. • Do not apply high load voltage (current) or surge current as this can Type)
• All work must be carried out in a safe manner by a qualified person in cause the switch to malfunction. 4.2.1. Before setting the color zone (red), turn the cover counter
compliance with applicable national regulations. 3.3 Mounting clockwise (approximately 6 to 7 mm) until it stops. Then remove by pulling
Caution it towards you.
2 Specifications • During transport and installation, do not apply shock to the product,
such as by dropping doing so will affect its precision.
Model GP46
• Regarding the installation posture, place it perpendicular to the ground,
Type Back side thread
Ambient and fluid temp. -5 to 60°C (No freezing) with the zero point on the reading of a pressure gauge facing down.
Indicated pressure range 0-1.0 MPa • Do not install it in an area that is exposed to high temperature or
Gauge

Port size (1) R1/8, R1/4 (Option M: with M5 humidity, because doing so will lead to improper operation.
female thread) • To screw in the pressure gauge, make sure to turn the gauge by The arrow in the diagram indicates the direction of the pressure increase.
Fluid (2) (6) Air placing a wrench over the square wrench flats. The light turns OFF when the pressure becomes higher than the set
Indicated precision (7) +- 0.03 MPa If the pressure gauge is screwed in by holding it on some other area, pressure and turns ON when the pressure becomes lower than the set
Setting Range (3) (4) 0.1 to 0.8 MPa air leakage or damage may result. 4.2.2. Use a pen tip to set the color zone (red). Be careful not to bend the
pressure.
Hysteresis 0.07 MPa 3.4 Environment other needle or damage the dial plate.
Pressure Switch

Pointer error (5) +-0.05 MPa (5-40°C) Warning


+-0.08 MPa (-5 to 60°C)
Contact With light: 1a (Normally open) • Do not use in an environment where corrosive gases, chemicals, salt
Without light: 1ab (Normally water or steam are present.
open/ Normally closed) • Do not install in an environment of high humidity.
Wiring Lead wire (Length: 300 mm) • Do not use in an explosive atmosphere.
Indicator AC Neon Light • Do not expose to direct sunlight. Use a suitable protective cover.
light DC Light emitting diode (LED) • Do not install in a location subject to vibration or impact in excess of
Clear cover Part no: G46-00-00-3
the product’s specifications.
• Do not mount in a location exposed to radiant heat that would result in
Attachment: C Part no: 1305104-4A
temperatures in excess of the product’s specifications.
With cover ring assembly C2 Part no: 1305104-10A
Weight (Kg) 0.12
Page 1 of 2
GP46-SMY13EN

4 Settings – continued 4 Settings – continued


4.2.3. After completing the setting, replace the cover. Fit the cover by 4.4 Procedure for Assembling the Cover Ring Assembly
aligning the cut out in the cover to the groove on the top of the black case. • Pressure gauge for general purpose
Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make
sure that the matching mark on the cover is aligned with the groove on
the top of the case.

• Pressure gauge with switch

4.3 Procedure for Setting the Limit Gauge Indicator and the Setting
Needle
4.3.1. Before setting the limit indicator and the (green) setting needle,
turn the cover counterclockwise (approximately 6 to 7 mm) until it stops.
Then, remove by pulling it towards you.
1. Remove the small screw (1 position) from the pressure gauge.
2. Place the cover ring on the pressure gauge.
3. Using the small screw that is provided with the cover ring, install the
cover ring. The installation torque is 0.6 to 0.7 N ・ m. However, when
reassembling, it shall be 0.5 to 0.6 N・m.

5 How to Order
Refer to drawings or catalogue for ‘How to Order’.
6 Outline Dimensions (mm)
4.3.2. Use a flat head screwdriver (with a 2.9 mm blade width) to set the
(green) limit indicator. Be careful not to bend the other needle or damage Refer to drawings or catalogue for outline dimensions.
the dial plate. 7 Maintenance
7.1 General Maintenance

Caution
• Not following proper maintenance procedures could cause the product
to malfunction and lead to equipment damage.
• If handled improperly, compressed air can be dangerous.
• Maintenance of pneumatic systems should be performed only by
qualified personnel.
• Before performing maintenance, turn off the power supply and be sure
4.3.3. Before setting the setting needle, use a flat head screwdriver (with to cut off the supply pressure. Confirm that the air is released to
a 2.9 mm blade width) to turn the setting screw and set the setting needle atmosphere.
to the set pressure. • After installation and maintenance, apply operating pressure and
power to the equipment and perform appropriate functional and
leakage tests to make sure the equipment is installed correctly.
• If any electrical connections are disturbed during maintenance, ensure
they are reconnected correctly, and safety checks are carried out as
required to ensure continued compliance with applicable national
regulations.
• Do not make any modification to the product.
• Do not disassemble the product, unless required by installation or
maintenance instructions.
8 Limitations of Use
8.1 Limited warranty and Disclaimer/Compliance Requirements
4.3.4. After completing the setting, replace the cover. Fit the cover by Refer to Handling Precautions for SMC Products.
aligning the cut out in the cover to the groove on the top of the black case.
9 Product disposal 10 Contacts
Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make
sure that the matching mark on the cover is aligned with the groove on This product should not be disposed of as municipal waste. Check your Refer to [Link] or [Link] for contacts.
the top of the case. local regulations and guidelines to dispose this product correctly, in order
to reduce the impact on human health and the environment.

URL : http// [Link] (Global) http// [Link] (Europe)


'SMC Corporation, Akihabara UDX15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101
0021
Specifications are subject to change without prior notice from the manufacturer.
© 2020 SMC Corporation All Rights Reserved.
Template DKP50047-F-085J

Page 2 of 2