Operating Instructions
Mini Dry Bath Incubator
Contents
Safety Instructions 2
Unpacking 4
Correct Use 5
Operation 5
Temperature Calibration 7
Maintenance and Cleaning 9
Technical Data 9
Warranty 10
1
Safety Instructions
• Read the operating instructions in full before starting up and
follow the safety instructions.
• Keep the operating instructions in a place where they can be
accessed by everyone.
• Ensure that only trained staff work with the appliance.
• Follow the safety instructions, guidelines, occupational health
and safety and accident prevention regulations.
• Socket must be earthed (protective ground contact).
• Before starting the device for the first time, ensure that the
connector cable is suitable for the type of socket used and
that a safe protective earth connection is assured.
• Risk of burns! Exercise caution when touching the housing
parts and the heating plate. The heating plate can reach
temperatures in excess of 100 °C. Pay attention to the residual
heat after switching off. The device may not be transported
unless it is cold!
• Don’t operate the appliance in explosive atmospheres, with
hazardous substances or under water.
• Set up the appliance in a spacious area on an even, stable,
clean, non-slip, dry and fireproof surface.
• The base plate must be clean and intact.
• The voltage stated on the type plate must correspond to the
mains voltage.
• The socket for the mains cord must be easily accessible.
• The power adapter cable must not be allowed to come into
contact with the hot mounting plate.
• Check the appliance and accessories before hand for damage
each time you use them. Do not use damaged components.
• Caution! Only media whose flashpoint lies above the safety
temperature limit of 130 °C may be processed or heated with
this device.
2
• Beware of hazards due to:
- Flammable materials
- Combustible media with a low boiling temperature
- Incorrect container size
- Overfilling of media
- Unsafe condition of container.
• Only process media that will not react dangerously to the extra
energy produced through processing. This also applies to any
extra energy produced in other ways, e.g. through light
irradiation.
• Bear in mind the possibility of contamination that might lead to
undesirable chemical reactions.
• Wear your personal protective equipment in accordance with
the hazard category of the media to be processed.
Otherwise there is a risk from:
- Splashing and evaporation of liquids
- Ejection of parts
- Release of toxic or combustible gases
• Do not heat liquid media except with the block. Never pour
liquid media directly on to the heating plate!
• Accessories must be securely attached to the machine and
can’t come off by themselves.
• Always disconnect the plug before fitting accessories.
• Safe operation is only guaranteed with the accessories
described in the “Accessories” chapter.
• The appliance must only be disconnected from the mains
supply by pulling out the plug-in power supply unit.
To the protection of the equipment.
- The appliance may only be opened by experts.
- Do not cover the device, even partially e.g. with metallic plates
or film. This results in overheating.
- Protect the appliance and accessories from bumps and impacts.
3
- Ensure that the base plate is kept clean.
- Observe the minimum distances between the devices, between
the device and the wall and above the assembly (min. 100 mm)
>100mm
>100mm (Fig. 1) >100mm
Unpacking
Please unpack the device carefully and check it for damage. It
is important that any transport damage is detected when the
device is unpacked. If necessary, any inventory of the damage
should be made immediately (postal service, railway, haulage
company).
package contains:
Item Qty.
Main Unit 1
Power adapter 1
Operating instruction 1
4
Correct Use
• Use
- For heating media in block heaters
• Range of use
- Laboratories, Schools, Pharmacies and universities
Operation
(Fig. 2) Lid
Block
LED Display
“TEMP/TIMER”
knob
Power switch
Power socket
(DC 12V)
5
• Temperature Setting
The temperature setting can only be workable when the
machine is powered on but not when it’s working. Short press
the blue knob; the temperature value on the LED display will
flash, and then set the temperature by horizontal rotation of
the knob.
• Time Setting
The time setting can only be workable when the machine is
powered on but not when it’s working. Short press the blue
knob twice; the time value on the LED display will flash, and
then set the time by horizontal rotation of the knob.
• Create a new program
The system can save 5 sets of programs of the temperature
and time. When the machine is powered on but not when
working, short press the button of “Prog.” to select the 5
default programs from P1 to P5. For example, if select P2,
press and rotate horizontally the blue knob to set the new
temperature and time as the method described as above.
Long press “Prog.” continuously to save the new data as P2..
• Program for quick operation
When the machine is powered on but not when working, short
press “Prog.” to select the required program for quick operation.
The program data can be changed by the blue knob
6
Temperature Calibration
Each single instrument is calibrated before shipment. If there is
deviation between the actual temperature and the displayed
temperature for some reasons, you can do as follow to calibrate
the unit again.
1. Long press the blue knob for more than 3 seconds and the
system will be in the calibration mode. When the machine is
ready for calibration, there’s only temperature on the display
and no time.
2. Press “Prog.” to select the calibration point of 40°C / 60°C /
80°C / 100°C (If they’re not the four calibration points in the
program, set the required temperature by rotating the blue
knob). Or directly rotate the blue knob to the appointed
calibration points instead of pressing “Prog.”
3. Put high boiling point solution (above 100°C, for example:
glycerin) into the block hole and then place a thermometer
into the hole. (Make sure the accuracy of the thermometer
should be within 0.1°C and the thermometer probe should be
absolutely immersed into the solution). And make sure to put
the thermometer into the hole which is in the middle of the
block or closed the middle hole.
4. Press the “Run/Stop” and the system will be in “Heating” mode.
5. After about 20 minutes of the “Holding” mode, read the data
from the thermometer and press “Run/Stop”. Adjust the
temperature of the machine by rotating the blue knob per the
reading of the thermometer.
6. Long press “Prog” to save the reading of the thermometer.
7. Repeat the above processes to do the calibration of other
calibration points. Refer to the below Table.
7
8. Restart the machine after the calibration.
Temperature Calibration
Item Calibration Point Reading of the thermometer
1 40°C
2 60°C
3 80°C
4 100°C
Maintenance and Cleaning
The appliance is subject only to the natural wear and tear of
components and their statistical failure rate. Use only cleansing
agents which have been approved by us to clean our devices.
To remove use:
Dyes isopropyl alcohol
Constructions materials water containing tenside / isopropyl alcohol
Cosmetics water containing tenside / isopropyl alcohol
Foodstuffs water containing tenside
Fuels water containing tenside
For materials which are not listed, please request information
from us. Please disconnect the main plug and do not allow
moisture to get into the appliance when cleaning. Wear the
proper protective gloves during cleaning of the devices.
Electrical devices may not be placed in the cleansing agent for
the purpose of cleaning. Before using another then the
recommended method for cleaning or decontamination, the user
must ascertain with the manufacturer that this method does not
destroy the instrument.
8
Technical Data
Model TC0401005 TC0401006
Temperature Control Range RT + 5°C~100°C RT + 5°C~100°C
Heating Lid No Yes
Timing Range 0~99h59min 0~99h59min
Temp. Control Accuracy ±0.5°C ±0.5°C
Display Accuracy ±0.1°C ±0.1°C
Heating Time (40°C to100°C Temp.) ≤15min ≤15min
Input Power 40W 45W
Dimension (mm) 164 x 116 x 98 164 x 116 x 98
Net Weight 0.9kg 0.9kg
Warranty
You have purchased an original laboratory machine which
meets the highest engineering and quality standards. In
accordance with our warranty conditions, the warranty period is
24 months . For claims under the warranty please contact your
local dealer. You may also send the machine directly to our
works, enclosing the delivery invoice and giving reasons for the
claim. You will be liable for freight costs.