RTD 0124
RTD 0124
Temperature
Product Description Accuracy Page
ºF ºC
RTDs Accurate, repeatable and -328 to 1200 -200 to 650 DIN Class A 68
interchangeable over a wide ± 0.06% at
operating range. 32°F (0°C)
DIN Class B
±0.12% at
32°F (0°C)
ENVIROSEAL™ HD Suited for heavy-duty applications -40 to 392 -40 to 200 Available with 80
including those in harsh either RTD or
environments. thermistors.
See
information
above.
67
Resistance Temperature Sensors
RTDs
Bends
Standard Bend Minimum “H” Minimum “C” C
Diameter
Radius Dimension Dimension
in.
in. in. in.
0.125 3/8 2 2
0.188 3/8 2 2 10 - 90° Radius
0.250 1/2 2 2
H
Term D
Lead Terminations
Termination Code Length
A —
B —
C —
Standard Male Plug
with Mating Connector
J —
K —
L —
Miniature Male Plug
with Mating Connector
Length T 11/2*
Split Leads
U 11/2*
Length
#8 Spade Lugs
* When style contains jacketed wire.
68
ed Bayonet Fitting
RTDs
Fitting Options
xed Bayonet Fitting
Fixed Fittings
Sheath Size NPT Thread Size Hex Size Length
Fitting Type Material Code
in. in. in. in.
d Fittings
A
303 SS 0.063 to 0.250 1/8 7/16 11/16 A
1
Fixed Single Thread
L ⁄8 NPT
Customer Specified
Compression Fittings
Non-Adjustable Compression Fitting Sheath Size NPT Thread Size Hex Size Length
Fitting Type Material Code
in. in. in. in.
69
Resistance Temperature Sensors
RTDs
Fitting Options (Continued)
Adjustable Spring Loaded
Sheath Size NPT Thread Size Hex Size Length
Fitting Type Material
in. in. in. in. Code
70
Resistance Temperature Sensors
RTDs
Watlow® manufactures a variety of RTD sensors that are
specially designed to ensure precise and repeatable
temperature measurement. Watlow sensors are built to
meet the most demanding industrial applications while
providing a lower total cost of ownership for our
customers.
Performance Capabilities
• Precise and stable within the wide temperature range
of -328 to 1200°F (-200 to 650°C)
Features and Benefits
Strain-free construction
• Provides dependable, accurate readings
• Allows elements from different lots to be substituted
with no recalibration needed
High signal-to-noise output
• Increases accuracy of data transmission
• Permits greater distances between sensor and
measuring equipment
Temperature coefficient (alpha) carefully controlled
while insulation resistance values exceed
DIN-IEC-751 standards
• Ensures sensor sensitivity
• Minimizes self heating Typical Applications
• Allows precise measurement
• Stoves, grills, fryers and other food equipment
• Repeatable
• Textile production
• Plastics processing
• Petrochemical processing
• Air, gas and liquid temperature measurement
• Exhaust gas temperature measurement
• Semiconductor processing
• Bearing and gear boxes
71
Resistance Temperature Sensors
RTDs
Standard Industrial Insulated Leads
Style RB
Lead Wire
L Length
1/ in.
2
Nominal
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮
Lead Lead Sheath Sheath Initial Lead
Sheath Wire Wire Sheath Length Length “L” Element Wire
O.D. (in.) Const. Fittings Term. Const. “L” (in.) (fract. in.) Element Accuracy Length (ft)
RB A 0
③ Sheath O.D. (in.) ⑦ Sheath Construction
G = 0.125 A= 316/316L SS
H = 0.188
⑧ ⑨ Sheath Length “L” (in.)
J = 0.250
Note: 0.125 dia. supplied with 28 gauge wire. 0.188 and 0.250 dia. Available lengths: 02 to 36
supplied with 24 gauge wire.
⑩ Sheath Length “L” (fractional in.)
④ Lead Wire Construction* 0= No fraction, whole inches
Standard Overbraid Flex Armor 4= 1/2 in.
Fiberglass stranded A J* R*
⑪ Element
PFA stranded B L* T*
2-Wire 3-Wire 4-Wire
Certain option combinations must be furnished with a transition between
100Ω single A B C
the sheath and lead wire. Contact the factory if a transition is
unacceptable. 100Ω dual* D E —
*May require a transition. 1000Ω single J K L
* Available in 0.250 inch diameter only.
⑤ Fittings
⑫ Initial Element Accuracy @ 0°C
If required, enter the order code from pages ??. If none enter “0.”
A= DIN Class A (±0.06%)
⑥ Lead Wire Termination B= DIN Class B (±0.12%)
A* = Standard male plug 400°F (200°C) ⑬ ⑭ Lead Wire Length (ft)
B* = Standard female jack Whole feet: 01 to 99
C* = Standard plug with mating connector Note: Single wires for 4 feet and under. Duplex wires for over 4 feet.
J* = Male miniature plug
K* = Female miniature jack
L* = Male/female mini set
T = Standard leads
U = Leads with spade lugs
* Requires two-or three-wire, single element only.
72
Resistance Temperature Sensors
RTDs
Plug or Jack Termination
Style RC
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬⑭ ⑮
Sheath Sheath Initial
Sheath Cold End Sheath Length Length “L” Element
O.D. (in.) Term. Fittings Const. “L” (in.) (fract. in.) Element Accuracy
RC 0 A 00 0
③ Sheath O.D. (in.) ⑧ ⑨ Sheath Length “L” (in.)
G = 0.125 Whole inches: 02 to 36
H = 0.188
⑩ Sheath Length “L” (fractional in.)
J = 0.250
0= No fraction, whole inches
Note: 0.125 dia. supplied with 28 gauge wire. 0.188 and 0.250 dia.
4= 1/2 in.
supplied with 24 gauge wire.
73
Resistance Temperature Sensors
RTDs
Metal Transitions
Style RF
L E
Ordering Information
Part Number
①② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬⑭ ⑮
Lead Lead Sheath Sheath Initial Lead
Sheath Wire Wire Sheath Length Length “L” Element Wire
O.D. (in.) Const. Fittings Term. Const. “L” (in.) (fract. in.) Element Accuracy Length (ft)
RF 0
③ Sheath O.D. (in.) ⑦ Sheath Construction
G = 0.125 K= 316/316L SS mineral insulated
H = 0.188
⑧ ⑨ Sheath Length “L” (in.)
J = 0.250
Whole inches: 03 to 99, metric lengths and lengths over
Note: All sheath diameters, MI cable only (high temp) are 24 gauge duplex
lead wire. 99 inches contact factory. Maximum length 165 inches.
PFA stranded B L T
⑪ Element
⑤ Fittings 2-Wire 3-Wire
If required, enter the order code from pages ???. If none enter “0.” 100Ω single A B
74
Resistance Temperature Sensors
RTDs
Connection Head/Optional Transmitter
Style RR
Single Double
Threaded Threaded
Fitting Fitting
L L
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬⑭ ⑮
Head Sheath Sheath Initial
Sheath Con. Mtg. Sheath Length Length “L” Element Tag
O.D. (in.) Head Fittings Const. “L” (in.) (fract. in.) Element Accuracy Style
RR 0 00
③ Sheath O.D. (in.) ⑫ ⑨
⑧ Sheath Length “L” (in.)
G = 0.125 A = Sheath construction requires 2 in. min to 36 in. max. length
H = 0.188 K = Sheath construction requires 3 in. min to 99 in. max. length
J = 0.250
Note: 0.125 dia. supplied with 28 gauge wire. 0.188 and 0.250 dia. ⑩ Sheath Length “L” (fractional in.)
supplied with 24 gauge wire. 0 = No fraction, whole inches
1 = 1/8
④ Connection Head 2 = 1/4
C = Polypropylene 3 = 3/8
D = Cast iron 4 = 1/2
E = Cast aluminum 5 = 5/8
H = Explosion proof 6 = 3/4
U* = E head with 5750 transmitter 7 = 7/8
V* = C head with 5750 transmitter
W* = H head with 5750 transmitter ⑪ Element
* For units with transmitter, the order must specify a range and degree 2-Wire 3-Wire 4-Wire
F or C, as well as a temperature span. 100Ω single A B C
100Ω dual *, ** D E —
⑤ Head Mounting Fittings 1000Ω single ** J K L
O = Single threaded, 303 SS * Available in 0.250 inch diameter only.
F= Double threaded, 303 SS 1/2 in. NPT ** Available with standard industrial construction only.
H* = Spring loaded, double threaded, 316 SS 1/2 in. NPT
⑫ Initial Element Accuracy @ 0°C
* Available in 0.250 inch diameter only.
A= DIN Class A (±0.06%)
⑦ Sheath Construction B= DIN Class B (±0.12%)
-58 to 500°F -328 to 1200°F ⑮
⑫ Tag Style
(-50 to 260°C) (-200 to 650°C)
0= Polymeric
316 SS 316 SS
1= 300 SERIES SST
Standard industrial A —
0.125 - 0.250 in. O.D.)
Mineral insulated — K
(0.125 - 0.250 in. O.D.)
75
Resistance Temperature Sensors
RTDs
For Use With Thermowells
Style RT
Type 1 Type 3 Type 4
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮
Sheath Sheath Initial
Sheath Conn. Cold End Sheath Length Length “L” Element Spring- Tag
O.D. (in.) Head Config. Const. “L” (in.) (fract. in.) Element Accuracy Loading Style
RT 0 0
③ Sheath O.D. (in.) ⑧ ⑨ Sheath Length “L” (in.) - See Drawings Above
J = 0.250 *When ordering a complete assembly with thermowell, specify “AR” as
Note: Supplied with 24 gauge wire. required and reference pages 103 to 107 for “U” dimension; otherwise,
specify the “L” dimension in whole inches.
④ Connection Head *Note, maximum sheath length is 36 inches for sheath construction A.
C = Polypropylene
D = Cast iron ⑩ Sheath Length “L” (fractional in.)
E = Cast aluminum 0 = No fraction, whole inches
H = Explosion proof 1 = 1/8
U* = E head with 5750 transmitter 2 = 1/4
V* = C head with 5750 transmitter 3 = 3/8
W* = H head with 5750 transmitter 4 = 1/2
* For units with transmitter, the order must specify a range and degree 5 = 5/8
F or C, as well as a temperature span. 6 = 3/4
7 = 7/8
⑤ Cold End Configuration
⑪ Element
1= Type 1
2-Wire 3-Wire 4-Wire
3= Type 3
100Ω single A B C
4= Type 4
100Ω dual* D E —
⑦ Sheath Construction 1000Ω single* J K L
-58 to 500°F -328 to 1200°F * Available with standard industrial construction only.
(-50 to 260°C) (-200 to 650°C)
⑫ Initial Element Accuracy @ 0°C
316 SS 316 SS
A= DIN Class A (±0.06%)
Standard industrial A —
(0.125 - 0.250 in. O.D.) B= DIN Class B (±0.12%)
(Max. length 36 in.) ⑭ Spring -Loading
Mineral insulated — K Y= Yes
(0.125 - 0.250 in. O.D.)
N= No
(Max. length 165 in.)
⑮ Tag Style
0= Polymeric
1= 300 SERIES SST
76
Resistance Temperature Sensors
RTDs
For Use With Thermowells
Style RW
11/2 in.
E (38 mm)
Stud
Size
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧⑨⑩ ⑪ ⑫ ⑬⑭ ⑮
Lead Stud Size Lead Wire
Sheath Wire Lead Wire - Hole Dia. Temp. Length “E” Special
O.D. (in.) Const. Term. (inch) Element Coefficient (foot) Reqmts.
RW G 0 000 0
③ Sheath O.D. (in.) ⑪ Element
G= 0.125 2-Wire 3-Wire
100Ω single A B
④ Lead Wire Construction
⑫ Temperature Coefficient
A = 900°F (500°C) Fiberglass stranded
DIN 0.00385
B = 400°F (200°C) Teflon® stranded
Class A A
⑥ Lead Wire Termination Class B B
A= Standard male plug
⑬⑭ Lead Wire Length “E” (foot)
B= Standard female plug
Whole feet: 01-99
C= Standard plug with mating connector
T= Standard leads ⑮ Special Requirements
U= Leads with spade lugs If none, enter “0.” If required, contact factory.
⑦ Stud Size - Hole Diameter (inch)
A = No. 6 - 0.144
B = No. 8 - 0.169
C = No. 10 - 0.196
D = 1/4 - 0.266
E = 3/8 - 0.390
77
Resistance Temperature Sensors
RTDs
Specialty Construction Styles
Adjustable Spring Style Open Air
Part Number 10 = 6 in. Part Number 50
Part Number 11 = 12 in.
E L E
0.3125 in. Spring
(7.9 mm) Length
L 0.187 in.
(Spring O.D. = 0.250 in. (6.4 mm)) (4.7 mm)
0.625 in.
0.265 in. (15.9 mm)
(6.7 mm) 0.187 in.
O.D. (4.7 mm) L E
0.3125 in. E
(7.9 mm)
Stainless Flange
L Steel Sheath 0.648 in.
and Flange (16.5 mm)
0.324 in.
(8.2 mm)
Surface Mount
Flange Part Number 80
Stainless 0.648 in.
Steel Sheath (16.5 mm)
and Flange 0.250 in. 1.375 in.
(6.3 mm) (34.9 mm)
0.324 in. E
(8.2 mm) 0.250 in.
0.187 in. (6.3 mm) 0.875 in.
(4.7 mm) (22.2 mm)
0.156 in.
(4 mm) Dia. 0.373 in.
(3) Holes (9.5 mm)
0.531 in.
(13.5 mm) 0.101 in.
0.343 in. Aluminum (2.6 mm) Dia.
(8.7 mm) Body (4) Holes
78
Resistance Temperature Sensors
RTDs
Specialty RTDs
Ordering Information
Part Number
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
Sheath Lead Wire
Const. Diameter Element Lead Length Length
Styles (in.) Type Type “L” (in.) “E” (ft) Term.
S
② ③ Construction Styles ⑧ Sheath Length “L” (in.)
10 = 6 inch adjustable spring style A= Not applicable K = 5.0 in. T= 9.0 in.
11 = 12 inch adjustable spring style C* = 1.5 in. L = 5.5 in. U= 9.5 in.
12 = Adjustable armor style D= 2.0 in. M = 6.0 in. W= 10 in.
25 = Cartridge with flange E= 2.5 in. N = 6.5 in. Y= 11 in.
50 = Open air F= 3.0 in. P = 7.0 in. Z= 12 in.
55 = Open air with flange G= 3.5 in. Q = 7.5 in.
80 = Surface mount H= 4.0 in. R = 8.0 in.
Note: See previous page for construction style drawings. J= 4.5 in. S = 8.5 in.
* 1.5 required for VAT construction: No. 10, 11, 12)
④ Diameter (in.)
D= 0.188 ⑨⑩ ⑪ Lead Wire Length “E” (ft)
A= Not applicable: surface mount 012 = 1 ft 084 = 7 ft
024 = 2 ft 096 = 8 ft
⑤ Element Type
036 = 3 ft 108 = 9 ft
C = RTD 2-wire, 100Ω DIN 0.00385
048 = 4 ft 120 = 10 ft
D = RTD 3-wire, 100Ω DIN 0.00385
060 = 5 ft 180 = 15 ft
⑥ ⑦ Lead Type 072 = 6 ft
L4 = Fiberglass and SS armor ⑫ Terminations
M4= Fiberglass
A = 1.5 inch stripped split leads, no terminals
N4 = Fiberglass and SS overbraid
B = No. 8 spade terminals
T2 = PFA
H = 0.25 in. female quick connect terminals
Specifications
• Two- or three-wire
• Resistance: 100Ω at 0°C
• Alpha curve: 0.00385Ω/Ω/°C
• Tolerance at 0°C: ±0.12%
• Range: -58 to 500°F (-50 to 260°C)
79
ed
end ity
E xt il
b
Resistance Temperature Sensors Ca
pa
ENVIROSEAL™ HD Sensors
Watlow’s ENVIROSEAL™-HD temperature sensor
keeps out moisture, oil and contaminants in all heavy-
duty applications including those outside applications
exposed to harsh weather, oils and other extreme moisture
environments. The ENVIROSEAL-HD sensor is designed
to provide accurate, dependable measurements in high-
vibration environments.
Features and Benefits
Submersible and 1200psi pressure wash rated seal
(not including connector area)
• Protects the sensor from washdown or other extreme Typical Applications
moisture environments • Engine coolant or oil
Oil resistant materials • Refrigeration or condensation units
• Sensors maintain a long life even when exposed to oil, • Industrial equipment
gasoline or diesel fuel • Heat exchangers
Vibration resistant design, 25 lb pull out force rating • Gear boxes
• Tough, rugged design to hold up to the roughest
• Hydraulic fluid
applications
• Marine
-40 to 392°F (-40 to 200°C) sensor temperature rating
• Offers superior application flexibility
Time response of two seconds
• Fast response measures 63.2% (first order) of the
temperature change in two seconds or less
250psi threaded fitting pressure rating
• Suitable for most rugged applications
80
ed
end ity
Ext il
b
Resistance Temperature Sensors Ca
pa
ENVIROSEAL HD Sensors
Sensor Types:
• RTD
• Sheath length: 0.75 to 3 inches
• Fitting: 1/4 inch NPT or 1/8 inch NPT male thread either
brass or 316 stainless steel
• Lead length: Up to 24 inches
• Lead wire: 18 gauge stranded with Tefzel® insulation
• Lead wire terminations: Stripped leads or Deutsch
2 pin connector or similar automotive style connector
81