0% found this document useful (0 votes)
54 views15 pages

Product 112

The document provides an overview of OPC (OLE for Process Control), which is an industry standard that enables open connectivity between industrial automation devices and software applications. It allows for plug-and-play compatibility between competing manufacturers' products. The document discusses how OPC addresses problems that arise from multi-layered automation system architectures and heterogeneous computing environments. It also covers topics such as the data formats and sources that OPC supports integration with.

Uploaded by

cementsaim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views15 pages

Product 112

The document provides an overview of OPC (OLE for Process Control), which is an industry standard that enables open connectivity between industrial automation devices and software applications. It allows for plug-and-play compatibility between competing manufacturers' products. The document discusses how OPC addresses problems that arise from multi-layered automation system architectures and heterogeneous computing environments. It also covers topics such as the data formats and sources that OPC supports integration with.

Uploaded by

cementsaim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

IDC Technologies - Books - 1031 Wellington Street Phone: +61 8 9321 1702 - Email:

West Perth [email protected]


WA 6005

OP-E - Practical Fundamentals of OPC

Availability: In Stock

Price: $139.94
Ex Tax: $127.22

Short Description
OPC has come a long way in making the engineers' dream of plug and play
compatibility in automation engineering achievable. OPC is an industry-wide
standard that breaks this proprietary lock by allowing open connectivity based on
the principles adapted from widely accepted and applied 'Microsoft Windows'
integration standards. OPC capabilities have been demonstrated in many
practical applications and it is now a well-established approach for different
competing manufacturers.

Description
OPC has come a long way in making the engineers' dream of plug and play
compatibility in automation engineering achievable. OPC is an industry-wide
standard that breaks this proprietary lock by allowing open connectivity based on
the principles adapted from widely accepted and applied 'Microsoft Windows'
integration standards. OPC capabilities have been demonstrated in many
practical applications and it is now a well-established approach for different
competing manufacturers.

It is now easily considered to be the standard interface in the Windows


environment. If you are serious about reducing your costs of installing and
maintaining your automation systems you need to use OPC. If you have only
briefly heard about OPC and want to get to grips with its tremendous power and
apply this to your plant and application, then this manual will give you the
necessary tools.

You will receive a valuable overview of OPC and understand why it is the
standard of choice for data access in automation systems. You will be exposed to
and understand the essential components of OPC based on typical applications.
You will understand how OPC servers are installed and how they are then
accessed by OPC clients (which could be SCADA systems). The OPC
specification is discussed in great detail and you will be exposed to the
development of OPC servers and clients.

Table of Contents
Download Chapter List

Table of Contents

First Chapter
Overview - Practical Fundamentals of OPC

1 OPC Overview

1.0 What is OPC?

OPC originally stood for ‘OLE (i.e. Object Linking and Embedding) for Process
Control.

Since OLE has been superseded by ‘ActiveX’ this acronym has become
meaningless and consequently ‘OPC’ has become just a name. It is sometimes
said to represent ‘Openness, Productivity and Connectivity’.

OPC is an open, standards-based infrastructure for the exchange of process


control data and specifies a set of software interfaces for several logical
(software) objects, as well as the methods (functions) of those objects. It is a
software standard supported by all major process control hardware vendors and
most OPC products (clients and servers) operate very much in an ‘out-of-the
box, plug-and-play’ fashion. If they so wish, users can develop their own clients
and servers by means of developers’ toolkits. It is even possible to develop
simple HMI systems without any programming knowledge at all.

The scope of OPC is to focus primarily (though not exclusively) on the exchange
of ‘raw’ data, i.e. the efficient reading and writing of data between an application
and a process control device. In other words, OPC is a ‘window’ through which
plant data can be observed. It accomplishes this by specifying the ‘rules’ for the
data exchange in sufficient detail to allow vendors to implement low level (i.e.
software) interfaces to process data.

There are, however, certain implementation issues not addressed by OPC (albeit
deliberately). These include:

Hardware interconnection. The protocol issues (drivers etc) for the I/O
subsystems are not covered by the OPC specifications, and have to be
taken care of by the server vendors
How clients and servers are to be implemented. Apart from specific
guidelines in the OPC specifications, and strict adherence to the interface
definitions, vendors can implement clients and servers in any way they
want. As a result, OPC products differ in terms of speed, reliability and
interoperability

The goals of the original OPC Task Force was to develop a way to facilitate easy
access to process data. The system had to be easy to use, easy to implement
(especially on the server side), had to operate efficiently in terms of the usage of
system resources (such as CPU usage), had to have a reasonably high level of
functionality, and had to be flexible enough to accommodate the needs of
multiple vendors. These goals were met, and the original; ‘OPC Task Force’
(1995), representing Fisher-Rosemount, Intellution, Intuitive Technology,
Opto22, Rockwell Automation, Siemens, and Microsoft has grown into the
present OPC Foundation with several thousands of members.

Figure 1.1

OPC Foundation logo

1.2 The problems addressed by OPC

1.2.1 Process control architectures

Most of the problems addressed by OPC can be traced back to the use of a multi-
layered process control architecture and a heterogeneous computing
environment.
Automation systems provide users with three primary services namely control,
configuration, and data collection. Control involves the exchange of time-critical
data between controlling devices such as PLCs and I/O devices such as
actuators and sensors. Networks that are involved in the transmission of this data
must provide some level of priority setting and/or interrupt capabilities, and
should behave in a fairly deterministic fashion, depending on the specific
application.
The second type of functionality, namely configuration, typically involves a
personal computer or a similar device in order for users to set up and maintain
their systems. This activity is typically performed during commissioning or
maintenance operations, but can also take place during runtime, e.g. recipe
management in batch operations.

The third involves the collection of data for the purposes of display (e.g. in HMI
stations), data analysis, trending, troubleshooting or maintenance.

Figure 1.2

Hierarchy of plant levels

Figure 1.2 shows a generic view of an automation system architecture. At the


device level, information is exchanged primarily between devices and networks
deployed on the plant floor. Fast cycle times are required, networks at this level
are bit-or byte oriented, and data packets are fairly small. Examples are HART,
AS-i, DeviceNet, PROFIBUS DP and Foundation Fieldbus H1. These are mostly
bit-or byte oriented network technologies and are generically referred to as ‘field
buses’.

At the control level data is primarily exchanged between HMIs and PLCs. At this
level speed is less critical and the amount of data exchanged in a packet is,
generally speaking, bigger. These are systems at this level is said to be message
oriented, and examples are ControlNet and Foundation Fieldbus HSE.

At the information level we find larger computers (e.g. mainframes) often


networked via Token Ring or Ethernet, often at up to 10 Gigabit speeds. Here,
determinism is not a factor. However, at this level there could be a large number
of different Operating Systems, such as Windows, UNIX and LINUX.

The current trend is for vendors to re-package their older systems by running
them via a TCP/IP stack over Ethernet, and these systems are used at the device
as well as the control level. An example is the ODVA’s Ethernet/IP, which is
basically DeviceNet running on TCP/IP and Ethernet.

Field buses are deployed on the ‘plant floor’ and should be able to operate in
a harsh environment (temperature, vibrations, EM-disturbances, moisture, etc.).
They should be robust and should be easily installed by skilled people. Other
desirable attributes are a high degree of integrity (i.e. no undetected errors), high
availability, with a redundant topology if required, a deterministic type of
operation, a built-in system supervision and diagnostics, support of fairly large
distances (up to a few kilometers if required), support of non-real-time traffic for
commissioning and diagnostics, and the option of intrinsic safety for some
applications within explosive environments.

1.2.2 Problems arising from the process control architecture.

Various categories of personnel, from operators to the CEO, need to access data
across all three layers at various points in time. This is difficult or almost
impossible due to various factors, relating to the data sources, data formats, data
users, the interconnection between data sources and data users, and Operating
Systems. These will now be discussed in more detail.

1.2.3 Data sources

Data sources could include (but are not limited to):

Computers
Databases (e.g. SQL)
Programmable Logic Controllers (PLCs)
Distributed Control Systems (DCSs)
Stand-alone (e.g. PID) controllers
Remote Terminal Units (RTUs)

Each of these would use a different protocol at layer 7 of the OSI model. Even if
they were all interconnected via the same physical network, the interrogating
(client) system would need to be able to converse via several protocols.

1.2.4 Data format

Data format is another problem area. The data source (e.g. server) could, for
example, make its data available in one of the following formats:
Boolean (single bit)
Character (signed 8-bit)
Word (unsigned 16-bit)
Short (signed 16-bit)
Dword (unsigned-32 bit)
Long (signed-32 bit)
BCD (2-byte packed BCD)
LBCD (4-byte packed BCD)
Float (32-bit floating point number)
Double (64-bit floating point number)
String (null terminated ASCII string)

The client software would need to accommodate all of these.

1.2.5 Data users

The plant data obtained from various sources could end up being used by
multiple clients. These could include:

Human-Machine Interfaces or HMIs (a.k.a. MMIs)


Supervisory Control and Data Acquisition (SCADA) systems
Trenders
Archivers
Electronic Resource Planning (ERP) or Manufacturing Resource Planning
(MRP) systems
Spreadsheets
Process Historians
Machine condition monitors

This data might be used for functions such as

Reporting
Operator interfacing
Trending
Alarming
Control strategies

Depending on the application, data could be accessed in groups or per individual


items. It could either be polled by the client at constant intervals or be forwarded
by the server to the client on an exception basis.

1.2.6 Interconnections
Interconnections, especially between Server host and I/O device, could be
varied. Technologies and standards employed could include:

Point-to-point links. Here, options include fiber, RS-232, RS-422, Bell-202


type modem links and 900 Mhz/2.4 GHz microwave links, to name but a
few
Multi-drop buses. Options here include RS-485 and IEC 61158
Options include Modbus, DNP3 and DF-1, to name but a few.
Fully-fledged industrial networks, implementing all (or at least layers 1, 2
and 7) of the OSI model stack include Ethernet/IP, PROFIBUS and
Foundation Fieldbus. There are several dozen contenders (‘field buses’)
at this level

1.2.7 Operating systems

This is another problem area. The various operating systems used server as well
as client hosts could vary between Windows (95/98/NT, 2000, XP, CE, 2003 etc),
UNIX, LINUX and various real-time operating systems for embedded controllers.

1.2.8 Drivers

Historically, the products that go into a process control system (such as field
instrumentation and control components) have been proprietary in nature.
Gradually, several hardware and signal exchange standards evolved in the field
of analog and digital instrumentation to ensure that the components
manufactured by different vendors can communicate with each other, at least at
a low level. For example, most analog field devices such as transmitters
communicate using standard signal values in the range of 4 to 20 mA.

The control system (or indicating instrument for that matter) to which this
transmitter is connected can thus compute the actual flow rate based on this
commonly understood, standard, signal. This means that the control equipment
need not be custom-designed for each transmitter, but can be designed and
manufactured irrespective of the parameter being measured, indicated or
controlled. In effect, a single measuring or control device can be used for flow,
pressure, temperature or any other conceivable parameter of any possible
measurement range.

Another benefit is, of course, the convenience of having a vendor independent


system. A transmitter supplied by a given vendor can thus be used with an
indicating instrument or a PID controller from any other vendor, provided they use
the same 4-20 mA standard. The output devices in the field, such as control
valves, are also based on the same standard. This means that a control system
that requires the control valve regulating the controlled parameter to be kept fully
open will simply send a signal of 20 mA to the valve.

While the example of a transmitter/controller/control valve typifies a hardware


standard, widespread use of computers for process control has given rise to a
need for standardization of software components as well. We are not talking
about the control software of a particular system component here; that remains
proprietary. In fact, the control software itself is of no relevance to anyone except
the manufacturer of that hardware or to a developer writing applications specific
to that hardware device. (Here too, standardization efforts have been taken up,
such as the standard for PLC Programming as per IEC-61131-3, but such
standardization may not be feasible for all types of devices). What is important is
that, when it comes to exchange of data between systems, a common standard
is absolutely essential.

Figure 1.3 shows a simplified example of a high-speed rotating machine control


system.

Figure 1.3

Control system example

The lower portion of the diagram shows three independent control systems, each
serving as a data source. They are:

A PLC for interlocking operations and for supervision of vital operating


parameters
A vibration instrument that measures machine vibration
A vendor-supplied performance calculation engine

The PLC will be connected to several I/O devices for control of the machine,
using its own standard interfaces and communication protocols. All these are
essentially self-contained devices that may include their own HMI hardware or
other form of output devices such as hardwired indicators, annunciators and so
on. However, they are also required to communicate with other devices provided
for overall control of the process itself, of which this particular machine is a
component.

The upper portion of the diagram shows three such devices:


An HMI used by the process control operator for obtaining the system
status, the alarm conditions when there is an undesirable deviation from
specific threshold values, and often for control of the process
A data archive for storing various measured values, events etc.
A machine condition monitoring system

Assume that all data sources and data users shown in this example are
proprietary systems. We can see right away that there is a need for each of the
data user devices to obtain data from each of the data sources shown here. For
example, the HMI will need status and alarm data from the PLC. It will also
require vibration readings and critical alarms in the event of excessive vibration
values for operator information. It will need interaction with the calculation engine
to display critical calculated parameters to the process operator and use the
results as inputs to say, an expert system application for operator guidance. The
same will be true of the data archive device and the machine monitoring system
also (refer Figure 1.4).

Figure 1.4

Communication between proprietary systems using separate drivers

With all these systems being proprietary in nature, direct communication between
any two devices is not possible without some customized interfacing. The HMI
will need an interface to access the data residing in the PLC. Similarly, it will
need another interface to access the data from the vibration measuring
instrument; and so on. Each interface is a special purpose software application
known as a device driver (simply referred to as a ‘driver’). Each connection
between two devices thus calls for two dedicated custom-developed drivers, one
at each end. These cannot be used with any other device, and even between a
pair of devices the driver may need to be rewritten if the data source or the data-
using device is replaced or upgraded.

There is also another less obvious problem. Each data source device has to
communicate through multiple drivers to the data users. This means that identical
data may be requested by multiple user devices and has to be communicated
separately to each by the data source. With slow serial protocols such as
Modbus Serial, such a requirement puts a severe strain on the communication
infrastructure. Thus:

We need nine device drivers in this scenario


Each will have to be custom-developed
Each may become useless if any of the corresponding devices is
replaced or even upgraded

The result is a lack of interoperability, getting locked-in to specific vendors, and


time consuming software development and on-going management. Such a
situation is neither in the user’s interest, because of the difficulties cited above,
nor in the manufacturers’ interest, because they are the ones expected to supply
the drivers. It is thus obvious that we can arrive at a ‘win-win’ situation by
making all devices talk in a common language. Let us now modify the example in
Figure 1.4 with another, representing communication through such a common
language. This is shown in Figure 1.5.

Figure 1.5

Communication between proprietary systems via OPC

In this scenario, each data source has a software component for making its data
available to other systems (let us call it the ‘server’) and each data user has a
software component to access the server for data (let us call this the ‘client’).
We have therefore created a ‘software bus’. By adopting a common data
interface standard, it is possible for any client to request data from any server in a
format that the server can understand. The server, in turn, makes the requested
data available to the client in a format that the client can understand. As long as
the client and server applications are all based on a common specification, any
client and any server can thus exchange data thereby ensuring interoperability.

Since there is no proprietary component in this data exchange mechanism, it


automatically ensures vendor independence. Scalability, too, is not an issue
since a new data source following the same data exchange specification can
easily be added. Device upgrades pose no problem either, since the data
exchange mechanism will still be based on the same common standard. Server
vendors are also not required to develop drivers to suit various client products,
but simply have to implement the required OPC interfaces.

1.3 The logical object model

It is, strictly speaking, inappropriate to talk about a logical (i.e. software) object
model for OPC as each specification has a different object structure. In other
words, there is a DA object model, an AE object model, etc. This is, in fact,
considered a shortcoming and is being addressed by the new UA standards. We
will clarify the concept be looking at the most poplar specification to date, the DA
(Data Access) specification. Initially this was known simply at the ‘OPC
Specification’.

There can be a one-to-one relationship between Client and Server, or,


alternatively, there can be a one-to-many or many-to-one relationship between
them as shown in the following figure. However, although multiple Client-Server
connections are possible, this is dependent on specific vendor implementations
and hence not always possible.

Figure 1.6

Basic relationship between OPC Clients and Servers (courtesy OPC


Foundation)

OPC Clients and Servers are simply COM objects (in fact, all software programs
on a Windows-based computer exist as COM objects and this can be verified
with ‘OLE Viewer’ software. The connection between client and server is via
well-defined interfaces, specified in Microsoft Interface Definition Language (IDL)
and typically implemented in C++. A typical interface specification looks like this
and only makes sense to a programmer. The example is for the CloneGroup
method of the IOPCGroupStateMgt interface:

IOPCGroupStateMgt::CloneGroup

HRESULT CloneGroup(

[in, string]LPCWSTR szName,

[in]REFIID riid,

[out, iid_is(riid)] LPUNKNOWN * ppUnk

(:

The infrastructure to carry the data between the Client and Server interfaces is
supplied by DCOM, described in the next chapter.

A more complex Client-Server relationship is shown in the following figure.


Here, the Client (A) obtains data from the server (B) via an OPC interface. The
Server, in turn, obtains I/O data from a Device (e.g. a PLC), shown as C. The
channel between the Server and the Device could, for example, be Ethernet or
RS-485, and the Server vendor would develop the Device drivers in consultation
with the Device vendor. In this specific scenario there is also s SCADA system
(D) that obtains its own data via an I/O subsystem (D). If the SCADA system is
OPC compatible, i.e. it has a built-in OPC server, then OPC server B could obtain
data directly from the OPC server on the SCADA system via OPC Bridging
software. Obviously this indirect method of obtaining data would be an issue if
fast access to the plant data is a prerequisite.

Figure 1.7

More complex relationship between OPC Clients and Servers

When ‘looking inside’ an OPC Server such as an OPC DA Server, the internal
structure of the server becomes evident. The structure varies from specification
to specification, but there is always a single Server control object at the top. In
the case of DA this object has the very creative name of OPCServer (note the
absence of a space after OPC). Below this are one or more OPCGroup objects,
and below each of these is one or more OPCItem objects. The Interfaces of the
OPCServer and OPCGroup objects extend to the outside world, but those of the
OPCItems do not, and as a result a Client can only be interrogated the items
indirectly via the OPCGroup interfaces.

Figure 1.8

Internal structure of DA Server

Incidentally, one of the drawbacks of the first generation of OPC specifications


is that they are not built around a coherent data model, i.e. the object hierarchy of
a DA server is different to that of an AE server. This has been addressed by the
new Unified Architecture (AU) - refer to Annexure A.

1.4 OPC Specifications

The OPC Foundation grew out of the OPC Task Force founded in 1995. With the
decision to base OPC on existing Microsoft OLE/DCOM technologies, the OPC
specification version 1.0 was already available by August 1996. This was
possible because the focus was on essentials, and the approach of not ‘re-
inventing the wheel’.

The first update was issued in September 1997. Now it was no longer called
the ‘OPC Specification’, but rather the Data Access (DA) specification 1.0A.
However, the need for acquiring data from a process goes beyond routine
operating data to more specific varieties of data such as events, alarm conditions
and historical data. Additional industry requirements and further developments in
Microsoft DCOM technology led to the next version called Data Access
specification 2.0.

Meanwhile, separate working groups were formed to cover the requirements of


exchanging information on events and alarms and the acquisition of historical
data. The OPC Alarms and Events (AE) specification was published in January
1999 (Version 1.01) and the OPC Historical Data Access (HDA) specification in
September 2000. A separate OPC Security specification was published in
September 2000 covering the security policies to be used by OPC components.
The specific data exchange needs of batch process control applications were
covered in a separate document called the OPC Batch specification.

As the number of OPC specifications increased, it was obvious that there are
elements common to all the specifications. This led to the issue of two additional
specifications. The first is known as the OPC Overview and contains only the
explanatory aspects, while the second was called the OPC Common Definitions
and Interface Specification and contains normative definitions. Other
functionalities for extending the scope of the Data Access specification include
the use of XML technology for enabling the use of OPC components for
accessing data over the Internet and in operating systems that do not support
DCOM. A separate working group called OPC DX deals with communication
between servers without involving a client.

OPC is a relatively new technology and is changing and expanding rapidly. The
‘first generation’ OPC standards shown below are all based on Microsoft DCOM
technology and (at October 2006) comprise the following specifications. All
specifications relate to the ‘Custom Interface’ (i.e. for use with C++) unless
indicated as ‘Auto’ for VB/VBA.

OPC XMLDA (XML Data Access) 1.01


OPC Commands 1.00 Specification 0.29
OPC HDA (Historical Data access) 1.20
OPC Complex Data 1.00
OPC DX (Data exchange)1.00
OPC DA (Data Access) 3.00
OPC AE (Alarms & Events) 1.10
OPC Common 1.10
OPC DA 2.05a
OPC Batch 2.00
OPC Batch Auto 1.00
OPC HDA Auto 1.00
OPC Security 1.00

DCOM, although a Microsoft invention, is not a proprietary solution that ‘locks


in’ users to Microsoft as it has been implemented by several other vendors and
is available for UNIX and LINUX as well. It is very efficient, as any object
accessing another object can do so with a single Remote Procedure Call (RPC)
to the other object, irrespective of the location of the other object. Provided that
there is the required network connectivity, there is hardly any difference in Client-
Server communication whether they are located on the same computer, or on
opposite sides of the world.

DCOM does, however, have shortcomings and, in particular, is not entirely


firewall-friendly and as a result it runs very well on a LAN, but not across on the
Internet. DCOM operation is subject to the security mechanism on a computer,
and recent security measures as implemented on Windows XP Service Pack 2
plays havoc with DCOM. It is also prone to time-outs, a situation that is
undesirable in process control applications. As a result, the OPC foundation
decided to migrate OPC to the Microsoft .NET (’dot-NET’) technology. A recent
decision was also to combine all the OPC functionalities in the so-called Unified
Architecture or ‘UA’ specifications.

UA is a very new concept and at this time (October 2006) only the UA
Concepts document has been released to the public. The other UA specifications
are still only available to OPC Foundation members, and some are still in draft
form. AU will therefore only be addressed in detail in the next revision of this
manual, but as an interim measure an overview is given in Annexure A.

The current UA specifications (October 2006) are:

OPC Test Lab RC1.00


OPC UA Part 1 Concepts 1.00
OPC UA Part 2 Security Model 1.00
OPC UA Part 3 Address Space Model 1.00
OPC UA Part 4 Services 1.00
OPC UA Part 5 Information Model 1.00
OPC UA Part 6 Mappings RC0.93
OPC UA Part 7 Profiles Draft 0.23
OPC UA Part 8 Data Access RC1.31
OPC UA Part 9 Alarms Draft 0.62
OPC UA Part 10 Commands draft 0.62
OPC UA Part 11 Historical Data Access Draft 0.991