Philippine Plumbing Code Overview

1. The plumbing works must be executed according to the Philippine Plumbing Code and coordinated with related drawings and specifications. Any discrepancies should be reported immediately. 2. Pipes, cleanouts, and check valves should be concealed where possible. Horizontal branches must maintain a minimum 1% slope unless noted otherwise. 3. Individual branches and fixtures must be provided with air chambers made of capped vertical pipe extensions as shown in the details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
937 views9 pages

Philippine Plumbing Code Overview

1. The plumbing works must be executed according to the Philippine Plumbing Code and coordinated with related drawings and specifications. Any discrepancies should be reported immediately. 2. Pipes, cleanouts, and check valves should be concealed where possible. Horizontal branches must maintain a minimum 1% slope unless noted otherwise. 3. Individual branches and fixtures must be provided with air chambers made of capped vertical pipe extensions as shown in the details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE 12. WATER METER SHOULD BE LOCATED OUTSIDE THE PROPERTY LINE.

EXECUTED IN ACCORDANCE TO THE REQUIREMENTS


OF THE PHILIPPINE PLUMBING CODE. 13. WATER SUPPLY FOR CISTERN AND SUPPLY LINE TO THE BUILDING
MUST BE LOCATED ALONG PERIMETER FENCE 400m. HEIGHT ABOVE
2. COORDINATE THE DRAWING WITH OTHER RELATED DRIVEWAY LEVEL WITH 3 LAYERS OF JUTE SACK AND BLACK COAL TAR.
DRAWINGS AND SPECIFICATIONS. THE ENGINEER SHALL
BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY 14. WATER LINE LAYOUT FOR WASHROOM TO SUPPLY UNITS.
FOUND THEREIN.
15. ALL WATER LINE SUPPLY FOR WASHROOMS SHALL NOT BE EMBEDDED IN
3. THE PLUMBING LAYOUT IS ONLY DIAGRAMMATIC. PIPES SLAB, BLOCKS OUT SHALL BE PROVIDED FOR POSSIBLE DIRECTION OF PIPES. GATE VALVE AREA DRAIN
CLEANOUTS AND CHECK VALVES SHALL BE CONCEALED.
4. ALL SLOPE OF HORIZONTAL BRANCHES (SEWER) 16. ALL FINAL LOCATION OF TOILET FIXTURES SHALL BE BASED ON THE M WATER METER MANHOLE
MAINTAIN 1% A MINIMUM, UNLESS NOTED OTHERWISE. MODULAR SETTING OF TILES.
CHECK VALVE WC WATER CLOSET
5. AIR CHAMBER : ALL INDIVIDUAL BRANCHES TO FIXTURE 17. DOUBLE DRAINS FOR BATH TUBS. CV
OR GROUP OF FIXTURES AND/OR EQUIPMENT SHALL
BE PROVIDED WITH AIR CHAMBER OF CAPPED VERTICAL 18. DOWEL FOR DOWNSPOUTS AND REINFORCEMENT 10mmØ @ 600mm STAGGERED WATER LINE
PIPE EXTENSION OF DIMENSION AS SHOWN IN THE DETAIL. LAV LAVATORY
19. PVC CEMENT FOR JOINTS WITH EPOXY OUTSIDE BONDING.
6. ALL FLOOR DRAIN SHALL BE VENTED INDIVIDUALLY.
SOIL PIPE
7. ALL CLEANOUTS SHALL BE FLUSH-MOUNTED TO FLOOR. DO 20. RISER SHOULD NOT CROSS MASTER'S BEDROOM OR OTHER MAIN AREAS.
NOT INSTALL FLOOR CLEANOUT EXCEPT AT LINES ON GRADE & FD
21. GI. PIPE SHOULD BE PAINTED WITH RED LEAD OR BLACK COALTAR, STORM DRAIN PIPE FLOOR DRAIN
SERVICE AREAS NOT SUBJECTED TO TRAFFIC.
IT SHOULD NOT BE EMBEDDED ON SLAB. SLEEVING OF PIPE IS REQUIRED
8. ALL BRANCHES OF FIXTURE OR GROUP OF FIXTURES SHALL VENT PIPE FLOAT VALVE
ON BEAM. FOLLOW WATER LINE LAYOUT AS PER PLAN.
BE PROVIDED WITH AIR CHAMBER MADE OF CAPPED VERTICAL
EXTENSION PIPE.
DS DOWNSPOUT
VENT & DOWNSPOUT - 50 TO 150mmØ SHALL BE
9. ALL UNDERGROUND GALVANIZED IRON (G.I.) INDIRECT CONTACT POLYVINYL CHLORIDE (PVC) PIPE. CLEANOUT
CO
WITH SOIL SHALL BE PROVIDED WITH TWO(2) COATS OF TAR DRAINAGE LINE - 50 TO 150mmØ SHALL BE POLYVINYL
COVERING WRAPPED WITH JUTE CLOTH.
CB CATCH BASIN
CHLORIDE (PVC) PIPE.SERIES 1000.
G.I. GALVANIZED IRON
10. ALL PVC PIPE SHALL BE OF APPROVED QUALITY AND POLYPROPYLENE MANUFACTURED ACCORDING TO ASTM 2729
PIPES FOR WATER DISTRIBUTION SHALL BE TYPE 20. HB HOSE BIBBED FAUCET
SEWER LINE - 50 TO 150mmØ SHALL BE BP BOOSTER PUMP
11. ALL PLUMBING WORKS THEREIN, SHALL BE UNDER THE POLYVINYL CHLORIDE (PVC) PIPE. KS KITCHEN SINK
DIRECT SUPERVISION OF A REGISTERED MASTER PLUMBER AND/ SDR-35 MANUFACTURED SD SHOWER DRAIN/STORM DRAIN
OR A DULY LICENSED SANITARY ENGINEER. ACCORDING TO ASTM 3034.
AC AIR CHAMBER
VS VENT STACK
WATER LINE - SHALL BE POLYPROPYLENE (PPR) PIPE.
PIPE DIAMETER - ALL PIPE DIAMETERS INDICATED IN (HOT & COLD) "BOR PLUS", "UNITEC", OR "VESBO" SS SOIL STACK
SP SOIL PIPE
THE DRAWINGS ARE INSIDE DIAMETERS. 1 GENERAL NOTES ST SEPTIC TANK
DP DRAIN PIPE
P 1 CWL COLD WATER LINE
PVC POLYVINYL CHLORIDE
Minimum Dimension of Septic Tank F FAUCET
FIXTURE SCHEDULE WATER SUPPLY FIXTURE UNIT (WSFU) SCHEDULE SIZE OF WATER MAIN LINE DD DECK DRAIN
DESCRIPTION SYMBOL NO. FU/ITEM DFU Vd = L x W x H DESCRIPTION SYMBOL NO. FU/ITEM WSFU 1. Total No. of WSFU = 24 VTR VENT THRU ROOF
FLOOR DRAIN FD 3 2 6 4.54 = 2w x W x 1.80 Hunter's Curve WP WASTE PIPE
LAUNDRY LAUN. 1 2 2
SHOWER DRAIN SD 3 2 6
W = 1.123 100 WT WATER TANK
L = 2(1.123) = 2.246 SHOWER HEAD SHO. 3 2 6 VP VENT PIPE

DEMAND (GPM)
LAVATORY LAV 3 2 6 LAVATORY LAV 3 1 3 80 SHO SHOWER HEAD
WATER CLOSET WC 3 4 12 Digestive Chamber: FLUSH VALVE BT BLADDER TANK
FLUSH TANK FV 3 3 9
2/3 of Vd (4.54) = 3.03 m³ (Minimum Volume) 60
KITCHEN SINK KS 2 2 4
3.03 = L x 1.123 x 1.80 KITCHEN SINK KS 1 2 2 WCO WALL CLEANOUT
FLUSH TANK WH WATER HEATER
TOTAL DFU 34 L = 1.497 = 1.50 m. SLOP SINK SLOP 1 2 2 40
NPSH NATIONAL PIPE PPR POLYPROPYLENE PIPE
1 Fixture Unit = 50 Gallons STRAIGHT HOSE
Leaching 1 20
Sewage Capacity = 34 DFU x 50 Gallons
1/6 of Vd (4.54 m³) = 0.75 m³ TOTAL WSFU 24 (FIRE HOSE) psi POUNDS PER SQUARE INCH
Sewage Capacity = 1700 Gallons / 6435.2 Liters/Day
Total Sewage Flow, over 5677.7 Liters/day WATER DEMAND CONSUMPTION: 0 20 40 60 80 100 120 140 160 180 200 220 240 260
= 6432.2 x 0.75 + 1125 Leaching 2 Q = PCWC x # of Person x Peak Factor
1/6 of Vd (4.54 m³) = 0.75 m³ WATER SUPPLY FIXTURE UNIT (WSFU)
= 5,951.4 Liters/day Q = 0.12 x 8 x 1.2
= 5.95 m³ Q = 1.152 m³ 24 WSFU = 15 GPM
Digestive Size = 5.95 x (2/3) = 3.73 m³ (Maximum Volume) Total Volume of Leaching = 1.50 m³
Minimum Dimension of Water Tank 18 GPM = 1.14 LPS 3
DESIRABLE SIZE OF LIQUID VOLUME 1.152 m³ x 3 days reserve = 3.456 m³ 2. For Fairly Rough Pipe LEGEND & ABBREVIATION
Checking:
Single Family Dwelling Unit for 4 bedroom unit
L (mm) W (mm) H (mm) @ 32.9 Pa/m Friction Loss for 1.14 LPS w/ value of approx. P 1
DIGESTIVE 1500 1150 1800 240 = 25mm. Ø Pipe
= 1200 gallons (4542 Liters or 4.54 m³) SIZE OF WATER TANK = 2 - 1.00m Ø x 2.10m
Design Data: LEACHING 1 800 600 1800 : USE 25mmØ MAIN WATER SUPPLY PIPE
Number of Person - 6 LEACHING 2 800 600 1800
Length is twice the width - (L=2w) 2 LOAD COMPUTATION
Liquid Depth = 1.80m DIGESTIVE CHAMBER = 3.03 m³
Freeboard or Airspace = 0.30m. LEACHING CHAMBER 1 = 0.86 m³ P 1
LEACHING CHAMBER 2 = 0.86 m³
MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-1
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT GENERAL NOTES PROJECT LOCATION ADDRESS
LOAD COMPUTATION STO NINO, CENTRAL BAKAKENG, BAGUIO CITY
Place ALAMINOS CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
B C B C
2500 2500

A 1 A
E E
I ANC IAN
C
VAR VAR

N E
L I
T Y
E R
O P
P R

DS DS
RA IN
4 STO RM D
PVC
Ø100
DS DS

KS
DS CO DS
Ø50 VS
3

3
E
KS Ø100 FD
Ø100

N
SS SS Ø 100 PVC
Ø 75 PVC

I
N

PVC
RAI
1931

1931
Ø 100 PVC
MD

LAV

0
WC WC

Ø10
Ø 50 PVC FD
R

Ø 75 PVC

T
STO

Ø 75 PVC
4231 Meter

4231 Meter
R
CO
VC

Ø100 SS LAV Ø100 SS

E
2

2
0P

Ø50 VS
UP CO

P
Ø10

Ø100 PVC

O
SEWER PIPE

R
SEPTIC
DN

TANK

P
2300

2300
Ø50 PVC VS

WC
Ø 100 PVC
1500
Ø 75 PVC
FD LAV
Ø50 PVC VS
1

1
CO FD
CB

TO CITY STORM TO CITY SEWER


DRAIN

P R O P E R T Y L I N E

3 2
R O A D

SEWER & STORM DRAINAGE LAYOUT SEWER & STORM DRAINAGE LAYOUT
1 2 SECOND FLOOR PLAN
GROUND FLOOR PLAN
P 2 SCALE: 1:75 Mts. P 2 SCALE: 1:75 Mts.

0 0.5 1 2 3 4 5 6 MTS. 0 0.5 1 2 3 4 5 6 MTS.

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-2
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING LAYOUT PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
B C D B C
2500 925
2500

A IAN
CE A 1
VAR IAN
C E
VAR

N E
L I
T Y
E R
O P

Ø75 PVC
P R

DS

PVC
4 Ø25 GV
BP

Ø75
2 - WATER
DS

PPR
TANK

Ø25
Ø25 LL
Ø25 GV F HB
VC

Ø25 TT
P

Ø25 LL
Ø75

DS PPR
Ø20

3
3

E
F

N
Ø25 PPR

I
PIPE UR

L
1931
1931

Y
PR

T
P
4231 Meter
4231 Meter

R
Ø25

E
2
2

UP

P
O
R
P
2300
2300

Ø20 LL
FV

MV LAV Ø20 LL
Ø20 PPR Ø20 PPR

1
1

HB Ø20 TT Ø20 TT

CV
Ø25 x Ø20 LR

WM
GV
P R O P E R T Y L I N E

3 2
FROM WATER R O A D
SOURCE TO
BWD
SEWER & STORM DRAINAGE LAYOUT WATERLINE LAYOUT
1 ROOF PLAN 2 GROUND FLOOR PLAN
P 3 SCALE: 1:75 Mts. P 3 SCALE: 1:75 Mts.

0 0.5 1 2 3 4 5 6 MTS. 0 0.5 1 2 3 4 5 6 MTS.

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-3
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING LAYOUT PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
B C B C D
2500 925
2500

A A IAN
CE
IANC
E VAR
V AR

NOTE: NO WATER LINE


WITHIN THIS ZONE

Ø20 PPR
PPR
Ø20
3

3
Ø20 TT Ø20 TT Ø20 LL
Ø25 PPR MV
PIPE UR Ø20 PPR
1931

Ø20 LL

1931
PPR

Ø20 TT LAV
FV MV
Ø20

FV
Ø20 TT
4231 Meter

4231 Meter
LAV
2

2
Ø20 LL

DN
2300

2300
1

1
WATERLINE LAYOUT WATERLINE LAYOUT
1 SECOND FLOOR PLAN 2 ROOF PLAN
P 4 SCALE: 1:75 Mts. P 4 SCALE: 1:75 Mts.

0 0.5 1 2 3 4 5 6 MTS. 0 0.5 1 2 3 4 5 6 MTS.

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-4
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING LAYOUT PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
DS

DS

TW
VS

EPIP CVP .mm57 Ø


DS
SH
O.

EPIP CVP .mm57 Ø


MV

CA

CA
EPIP CVP .mm57 Ø

TW LA
V V
VS 75
PV
C SH
O. LA
FV
Ø SS R
00 VS
FD Ø1Ø50 0 PP R
WC R Ø2 OO
O PR L
LO 0P DF
DF Ø2 2N
2N
CO MV R
PP

CA
20
Ø

CA
SS CVP .mm001 Ø
V
FD V LA
0V
S LA
Ø5 FV
00
Ø1 SS WC PPR 1
PVC 0 1 Ø20
CO
Ø10

C C
FD
SS CVP .mm001 Ø

DEEFPU RPP 52Ø


B

)RU( RESIR
E
N
DAISN
E I
N L
I
DR L Y
T
RM SH
Y R
T
O O
E

E
ST
R
E N . P
E

O
C P

I
N

PV
R

L
O
I R P
0
L

10 Y
P
Ø S

T
0S
Y

VS R
0
T

R VC Ø1 E
DS 0P

P
E Ø5 OR
VS LC O
P

VC 1 LO

R
O
R 0P LC P F

CA
P
KS Ø5 2 ND
W F OU
KS MV
ST C E
R
V PV PIP F G
00 R BP
Ø1EWE HB LA
V 2

CA
S 2 5G
V
A

ER Ø2
EW
PR
CO
P
YS
Ø25
V R D
CO CIT
D 5G PP
Ø2
4 VC
TO 4 Ø
20
FV PR N
E
WC 100 PPVC LAV
E I
CODS I
N
MV Ø2
0P L
A
Ø Ø 75 L Y
00 RAIN VS A PPR T
Ø1 SS STO
RM D VC
0P
FD T
Y Ø25
E
R
PVC R
Ø100 Ø5
VS E PR P
0P
O
VC CO O
P
Ø2 B
R
O
0P R 3 CV P
3 Ø5 P O H R WM
GV
PP
M
CB
Ø25
OR
ST R
I TYRAIN R 2 R
TE O
C D
2 TO WA E T
M RC D
3 3 O U
FR SO BW

1 1

SEWER & STORM DRAINAGE LAYOUT WATERLINE LAYOUT


1 PLUMBING ISOMETRY 2 PLUMBING ISOMETRY
P 5 SCALE: 1:100 Mts. P 5 SCALE: 1:100 Mts.

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-5
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING ISOMETRY PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
LEGEND:
PPR - POLYPROPYLENE PIPE
PVC - POLYVINYL CHLORIDE PIPE
LL - ELBOW EQUAL CONNECTOR
LR - ELBOW REDUCER CONNECTOR
TT - TEE EQUAL CONNECTOR
TR - TEE REDUCER CONNECTOR
SR - STRAIGHT REDUCER CONNECTOR
GV - GATE VALVE
MV - MIXING VALVE
FV - FLUSHOMETER VALVE
LAV - LAVATORY
WC - WATER CLOSET
KS - KITCHEN SINK
LS - LAUNDRY SINK
FD - FLOOR DRAIN
SD - SHOWER DRAIN VSTR
SHO. - SHOWER
DS - DOWNSPOUT Ø50 PVC VENT Ø50 PVC VENT
ROOF LINE
AC - AIR CHAMBER VSTW
DIRECTION OF FLOW CAP SHOWER CAP SHOWER
AC AC
GAS OR AIR FLOW SHO. SHO.
COMMON T&B

Ø100 PVC VENT STACK

Ø100 PVC VENT STACK


BP - BOOSTER PUMP

Ø50 PVC VENT


Ø50 PVC VENT
MASTER T&B

Ø75 PVC VENT

Ø75 PVC VENT


FITTING SYMBOL: LAV LAV
MV MV
FAUCET FAUCET
TEE PROPOSED /SPIGOT /SPIGOT

Ø20 PPR

Ø20 PPR
WATER WC WC

Ø20 PPR

Ø20 PPR
GATE VALVE TANK

Ø20 PPR

Ø20 PPR
(1.0 m Ø x 2.1 m) FV FV
Ø20 TT Ø20 TT
CHECK VALVE Ø20 PPR Ø20 PPR
Ø20 LL Ø20 PPR Ø20 PPR SD 2ND FLOOR LINE
P-TRAP FD FD CO

Ø20 PPR PIPE UPFEED RISER (UR)


CO Ø100 PVC WASTE PIPE @ 2% SLOPE Ø50 PVC VENT VSTW
CAP Ø50 PVC VENT
WYE CAP SHO.

Ø100 PVC SOIL STACK


AC
Ø25 PPR PIPE

Ø50 PVC VENT


Ø50 PVC VENT
45° ELBOW POWDER ROOM

Ø75 PVC VENT STACK


KITCHEN SINK

Ø75 PVC VENT


PROPOSED
90° ELBOW WATER KS MV LAV
TANK KITCHEN
FAUCET
(1.0 m Ø x 2.1 m) /SPIGOT
Ø25 LL WM Ø25 LL
BP KS WC

Ø20 PPR
Ø75 PVC

Ø20 PPR
GV CV

Ø20 PPR
Ø20 LL Ø20 LL
FV
GV GV
Ø20 PPR FD
Ø20 PPR GROUND FLOOR LINE
FROM WATER Ø20 LL Ø20 LL
Ø25 LL Ø25 LL Ø25 TT Ø25 GI PIPE
CV OPE
SOURCE TO Ø25 GI PIPE
Ø75 PVC @ 2% SL CO
BWD BYPASS Ø25 PPR
E PIPE
C WAST
SEPTIC TANK Ø75 PV

Ø100 PVC SOIL STACK


TO CITY CO
SEWER
PE
Ø100 PVC SEWER PIPE @ 2% SLO

LC 1 LC 1 DC
TO CITY
SEWER

SEWER & WATER LINE


1 SINGLE LINE RISER DIAGRAM
P 6 SCALE: NTC

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-6
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT RISER DIAGRAM PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
2750

8
NOTE: SEE REVISED NATIONAL PLUMBING CODE OF THE

B
P
150 1500 150 800 150
PHILIPPINES (Appendix B - B.5 SEPTIC TANK
CONSTRUCTION)
5" CHB EXTERIOR WALL w/ 1 SEPTIC TANK DETAIL
150

150
1 21 " THICK PLASTER @ BOTH SURFACE AREA

P 7 SCALE: 1:75 Mts.

LINE OF WALL FOOTING


LEACHING
500 CHAMBER 1
CAPACITY: A

500
1.00cu.m
P 8
MANHOLE
1450

1150

500

150
100Ø INLET MANHOLE

LEACHING
CHAMBER 2
CAPACITY:

500
DIGESTIVE CHAMBER 1.00cu.m
MANHOLE
CAPACITY: 3.73 cu.m
100Ø OUTLET

5" CHB EXTERIOR WALL w/


150

150
1 21 " THICK PLASTER @ BOTH SURFACE AREA
300 SOIL FILL

2750 1450
150 1500 150 800 150 150 500 150 500 150
NATURAL GRADE LINE NATURAL GRADE LINE
(UNPAVED SURFACE AREA) 16mm. Ø REBAR HANDLE (UNPAVED SURFACE AREA) 16mm. Ø REBAR HANDLE
100mmØ PVC
VENT PORT
co
Verify 2% Slope

200

200
MANHOLE MANHOLE MANHOLE MANHOLE
50 Min.

co
AIR SPACE
325

325
101.6 Min.
101.6 Min

100Ø INLET WATER SURFACE


304.8 Min

SCUM

1" THICK PLASTER @ BOTH SURFACE AREA


1" THICK PLASTER @ BOTH SURFACE AREA

101.6

TO CITY SEWER

5" CHB EXTERIOR WALL w/


1" THICK PLASTER @ BOTH SURFACE AREA
5" CHB EXTERIOR WALL w/

1" THICK PLASTER @ BOTH SURFACE AREA

1" THICK PLASTER @ BOTH SURFACE AREA


100Ø OUTLET

EFFLUENT
4" CHB BUFFER WALL w/
2525

2525
5" CHB EXTERIOR WALL w/

5" CHB EXTERIOR WALL w/


DIGESTIVE CHAMBER
1800

1800
CAPACITY: 3.73 cu.m LEACHING LEACHING LEACHING
CHAMBER 1 CHAMBER 2 CHAMBER 1
CAPACITY: 1.00cu.m CAPACITY: 1.00cu.m CAPACITY: 1.00cu.m

SLUDGE
200

200
SECTION @ A SECTION @ B

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-7
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT SEPTIC TANK DETAIL PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
100Ø VENT PIPE
CAPPED
800 800
2ND FLOOR
100 600 100

D
100 Ø OUTLET
100 Ø OUTLET

B B
150 mm. THICK WALL P 6 P 6 PIPE SIZE D
4" CHB @ 1" THICK
TO FIXTURE 15 mmØ 300mm
PLASTER ON
BOTH SURFACE SIDE 20 mmØ 450mm
REBAR @ 10mm. Ø 25 mmØ 500mm
100

PIPE SIZE mmØ


800
600

800
100 Ø OUTLET 100 Ø INLET 100 Ø OUTLET 100 Ø INLET
A A FROM SUPPLY
P 6 P 6
100

3 AIR CHAMBER DETAIL


P 8 SCALE: NTS
100Ø SOIL STACK

PLAN CATCH BASIN COVER PLAN

800 800
150 500 150 150 500 150
100 Ø OUTLET
100Ø SOIL STACK 75Ø VENT STACK
100

100

AIR SPACE
100Ø CAP/PLUG
1000

1000
800

800

WATER SURFACE
150 Ø OUTLET 150 Ø INLET
100
100

100

GROUND FLOOR

SECTION @ A SECTION @ B

1 CATCH BASIN DETAIL 2 SOIL & VENT STACK CONNECTION DETAIL


P 8 SCALE: NTS P 8 SCALE: NTS

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-8
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING DETAIL PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600
FLOOR SLAB FLOOR SLAB

SLOTTED DRAIN COVER SLOTTED DRAIN COVER


SEEPAGE PAN SEEPAGE PAN
COMPACTED COMPACTED
GRAVEL BASE COARSE GRAVEL BASE COARSE
PITCH OR SLOPE OF PIPE LINE: USUALLY, THE WASTE PIPE IS

50mm Ø PVC PIPE 50mm Ø PVC PIPE INSTALLED AT 2% OR 20mm SLOPE PER METER RUN.

300mm.(MAX.)

300mm.(MAX.)

2%
50mm Ø 50mm Ø
PVC P-TRAP PVC P-TRAP

@ GROUND FLOOR @ SUSPENDED SLAB


1 FLOOR DRAIN DETAIL 2 FLOOR DRAIN DETAIL 3 PITCH OF SLOPE DETAIL
P 9 SCALE: NTS P 9 SCALE: NTS P 9

POLISHED BRASS COVER


(M-349-24) (134)
CL RAISE HEAD PLUG CL POLISHED BRASS COVER (M-349-24)

25
PVC PIPE

FIN.FLR.LINE FIN.FLR.LINE
COMPACTED PVC PIPE

100
GRAVEL BASE
COARSE

200 (MIN.)
RAISE HEAD PLUG
200 (MIN.)

FLOW 1/8 BEND PVC PIPE

100mm Ø PVC PIPE FLOW

1/8 BEND PVC PIPE


FLOW
PVC PIPE
100mm Ø LONG
SWEEP BEND
100mm Ø PVC PIPE

4 GROUND FLOOR CLEANOUT DETAIL 5 SUSPENDED FLOOR CLEANOUT DETAIL 6 OUTDOOR CLEANOUT DETAIL
P 9 SCALE: NTS P 9 SCALE: NTS P 9 SCALE: NTS

MASTER PLUMBER DRAWN PRP PROJECT TITLE PROJECT OWNER SHEET NO.
This document is owned and
CHECK PRP
solely property of Villa Preciosa
RICARDO D. LANTAJO JR. PROPOSED TWO
Realty, Inc.(VPRI). Any alteration DATE 10/26/2022 SPS. GEOVANI LAZO PIZA &
STOREY RESIDENCE
and tampering of this document
without the consent of VPRI and
PRC 11691 Validity 6 - 02 -2024 REMARKS HILDA ARELLANO PIZA P-9
it's architect is not valid. PTR 734347 Issued 1 - 05 -2022 CONTENT PLUMBING DETAIL PROJECT LOCATION ADDRESS
Place ALAMINOS CITY STO NINO, CENTRAL BAKAKENG, BAGUIO CITY NO. 25-D RIMANDO ROAD, BAGUIO CITY, 2600

You might also like