CONSTELL
CONSULTANTS PVT. LTD.
PRESSUREMETER TEST RESULTS (pressure Calibration/ Air Calibration)
Project: Geotechnical investigation works from Khidirpur to Esplanade of Joka-Esplanade Metro Corridor
Location : N 2492919.2m , E 636551.0m Ground elevation : + 5.4 m
Test No.: PMT-4/3A Static water level : 1.10 m b.g.l
Probe used : NX
Test depth: 18.00m Temp : 34 ° C Date: 14.06.2021 Time: 14:30 hrs.
Observed volume,
Observed volume,
Applied pressure
Volumetric
vm30 (cc)
vm60 (cc) 1000
vm60 - vm30
reading
(Bar)
(cc)
(cc) 900
800
Injected Volume, Vm60 (cc)
15 sec. 30 sec. 60 sec. 30 sec. 60 sec.
0.0 0.0 0.0 0.0 0.0 0.0 0.0 700
0.1 10.0 20.0 25.0 20.0 25.0 5.0 600
0.2 30.0 35.0 45.0 35.0 45.0 10.0
0.3 50.0 60.0 70.0 60.0 70.0 10.0 500
0.4 90.0 95.0 100.0 95.0 100.0 5.0 400
0.5 115.0 125.0 135.0 125.0 135.0 10.0
0.6 150.0 165.0 185.0 165.0 185.0 20.0 300
0.7 200.0 215.0 230.0 215.0 230.0 15.0 200
0.8 245.0 260.0 270.0 260.0 270.0 10.0
0.9 285.0 300.0 320.0 300.0 320.0 20.0 100
1.0 330.0 350.0 365.0 350.0 365.0 15.0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Pressure (Bar)
Pressure Calibration Curve
PRESSUREMETER TEST RESULTS (Volume Calibration/ Pipe calibration)
Applied pressure
Observed
Observed
Volumetric
vm30 (cc)
vm60 (cc)
volume,
volume,
400.0
vm60 - vm30
reading
(Bar)
(cc)
(cc)
350.0
15 sec. 30 sec. 60 sec. 30 sec. 60 sec.
300.0
Calibration Vol. (cc)
0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.3 60.0 80.0 105.0 80.0 105.0 25.0
0.5 150.0 175.0 210.0 175.0 210.0 35.0 250.0
0.8 240.0 260.0 260.0 260.0 260.0 0.0
1.0 280.0 280.0 285.0 280.0 285.0 5.0
200.0
1.3 305.0 310.0 310.0 310.0 310.0 0.0
1.5 310.0 310.0 315.0 310.0 315.0 5.0
1.8 325.0 330.0 330.0 330.0 330.0 0.0 150.0
2.0 330.0 330.0 335.0 330.0 335.0 5.0
2.3 340.0 340.0 345.0 340.0 345.0 5.0 100.0
2.5 345.0 345.0 350.0 345.0 350.0 5.0
3.0 350.0 350.0 350.0 350.0 350.0 0.0
3.5 350.0 350.0 350.0 350.0 350.0 0.0 50.0
4.0 350.0 350.0 350.0 350.0 350.0 0.0
4.5 350.0 350.0 350.0 350.0 350.0 0.0 0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0
Calibration Pressure (Bar)
-52-