FL500-H2 UV/IR
FLAME DETECTOR
Rugged stainless Self-check feature
steel enclosure
IR detector
UV detector
Three LED status indicators
Custom ID tag
for alarm, fault, and normal
attachment
operating conditions
UV/IR TECHNOLOGY SAFETY INTEGRITY SELF-CHECK
A UV/IR flame detector combines an ultraviolet (UV) sensor Every two minutes, a built in self-check known as Continuous
for quick response and an infrared (IR) sensor that monitors Optical Path Monitoring (COPM) performs an optical and electrical
radiation emitted by a hydrogen flame. This combination offers check to ensure the optical path is clear and the electronic circuitry
increased immunity, operates at faster speeds and is suited for is operational.
both indoor and outdoor use.
IMPROVED DESIGN RELIABLE TESTING ANYTIME, ANYWHERE
Stainless steel housing, three LED status indicators, reduced The FL500 can be tested with our exclusive TL105 Test Lamp,
footprint, and simplified wiring make the FL500 easy to install which simulates the flickering of a fire. This allows the detector
and maintain. to be tested under simulated fire conditions without the associated
risk of an open flame.
FL500-H2 UV/IR FLAME DETECTOR
SYSTEM SPECIFICATIONS ELECTRICAL SPECIFICATIONS
Wave Lengths 185 to 260 nm (UV) Input Power 20-36 VDC
2.95 microns (IR) 200 mA max. current
Field of View Up to 130° max. conical (3 W max. power consumption)
Fuel Distance (ft.) Response Time (s) Typical Current 80 to 150 mA
Hydrogen 60 < 3.0 Analog Output Source or Sink
Accessories test lamp Analog Signal 0-20 mA
Classification Class I, Div 1, Groups B, C, D; Fault Mode 0-0.2 mA*
Class II, Div 1, Groups E, F, G; COPM Self-Check Fault 2 mA, ± 0.2 mA**
Class III, Type 6P
Ready Signal 4 mA, ± 0.2 mA
Ex db IIC T5 Gb;
Ex tb IIIC T100°C Db IR Signal 8 mA, ± 0.2 mA
II 2 G D UV Signal 12 mA, ± 0.2 mA
IP66/IP67
Alarm Low 16 mA, ± 0.2 mA
Warranty Two Years
Alarm High 20 mA, ± 0.2 mA
Approvals CSA, ATEX, IECEx, CE Marking
Relay Contact Rating 5 A 250 VAC,
HART 7 registered
5 A @ 30 VDC resistive (North America),
5 A @ 30 V RMS/42.4 V peak,
5 A @30 VDC resistive (Europe)
ENVIRONMENTAL SPECIFICATIONS
Dip Switch Selectable Options
Operating Temperature Range -67°F to +185°F Sensitivity High, Medium, Low
(-55°C to +85°C) Time Delay Alarm High 2, 4, 8, or 10 seconds
Storage Temperature Range -40°F to +185°F Alarm Low & Alarm High Relays Latching/Non-Latching
(-40°C to +85°C) Energized/De-Energized
Operating Humidity Range 0% to 95% RH, non-condensing RS-485 Output Modbus RTU, suitable for linking up to 128
units or up to 247 units with repeaters.
BAUD Rate 2400, 4800, 9600, or 19200 BPS
MECHANICAL SPECIFICATIONS HART Fully HART 7 FieldComm compliant
Housing 316 Stainless Steel, powder coated EMC Complies with EN 50130-4, EN 61000-6-4
Diameter 4.5” (114 mm) Cable Requirements Screened or screened and armored to
BS5308 Part 2, Type 2, or equivalent.
Length 5.5” (140 mm)
Status Indicator 3 LEDs with status, fault,
Weight 9 lb. (4.0 kg) and alarm conditions
Mounting Stainless steel mounting bracket Faults Monitored Memory checksum, reset line shorted,
Cable Entry 2 x 3/4” NPT or 2 x 25 mm optics blockage, internal voltages,
Standard Configuration FL500-3-5-1-2-1-2-1-1 and low supply voltage
3.5 mA HART, source current, relays,
Modbus, high sensitivity, 4 sec. delay, * Under HART, current values can be either 3.5 mA or 1.25 mA, depending on user selection
** Under HART, current values can be either 3.5 mA or 2.0 mA, depending on user selection
Hydrogen, 3/4” NPT, mounting bracket
Note: This Bulletin contains only a general description of the products shown. While product uses and performance capabilities MSA operates in over 40 countries
are generally described, the products shall not, under any circumstances, be used by untrained or unqualified individuals. The
products shall not be used until the product instructions/user manual, which contains detailed information concerning the proper worldwide. To find an MSA office near you,
use and care of the products, including any warnings or cautions, have been thoroughly read and understood. Specifications are
subject to change without prior notice.
please visit [Link]/offices.