2.
4 Control Unit
2.4 Control Unit
XH10P-W-5P
L=1.5/10/20/30 m
Left Button
Wheel
Right Button
Power Switch
Trackball
Fig. 2.4.1 Standard Control Unit (RCU-014J) Japanese version
Fig. 2.4.2 Standard Control Unit (RCU-014E) English version
2-37
2.4 Control Unit
J505 (For PROGRAM update port, J502 (REMOTE) for RCU-016
Factory use)
Cable Clamp
J501 (PROCESSOR) for PRU-013
J506 (EMRI) for EMRI Trackpilot
J507 (SYSTEM FAIL)
CR10 (Option of CPU,
U8, Blinks every second)
U8(CPU) Buzzer Board (03P9362)
PNL Board (03P9343)
Trackball J504 (TB) S36 (DIP SW)
S36 Function
SYSTEM FAIL ALARM
JP1 #1
(ON: Output from J507)
Open (Write Program) RELAY STATUS
Short (Ordinary) #2
(ON: Reversed polarity of the above signal)
#3 Not used
#4 Not used
Fig. 2.4.3 Standard Control Unit (RCU-014) with Cover Removed
2-38
2.4 Control Unit
Power Switch
RCU-015: Provided
RCU-016: Not provided
XH10P-W-5P-A
L=1.5/10/20/30 m
Fig. 2.4.4 Trackball /Remote Control Unit, RCU-015/016
J521 (PROCESS0R)
- RCU-013 Connector CR11(U5 CPU RUN)
- RCU-016 connects with RCU-015 Blinks every second.
(Remote Panel.)
トラックボール部
JP1
Open (Write Program)
Short (Default)
J527 (SYSTEM FAIL)
J524 (TB)
J522 (REMOTE)
- RCU-015 connects with RCU-016
(PROCESSOR.) ■ PNL 基板 (03P9344)
J525 (PROGRAM, Factory use)
S6 (DIP SW)
S6 Function
SYSTEM FAIL ALARM ON/OFF
#1
(ON: Output from J507)
RELAY STATUS
#2
(ON: Reversed polarity of the above signal)
Fig. 2.4.5 Trackball/Remote Control Unit (RCU-015/016) with Cover Removed
2-39
2.5 Optional Unit
2.5 Optional Unit
LAN Port
(100BASE-T)
Mini Card Slot (x2) for
C-MAP, NAVIONICS,
and FURUNO chart card. Power Supply
(12 VDC)
Port A Port B
Fig. 2.5.1 Card Interface Unit, CU-200
S1 (DIP SW)
#1: INIT #3: IP1
#2: IP2 #4: IP0
CR2 (U12 CPU RUN,
When two CU-200s are installed, on Blinks every second.)
S1-#4 2nd units is set to ON.
NET-100 Board
(03P9332)
CARD CPU Board
(03P9333)
Fig. 2.5.2 CU-200 with Cover Removed
2-40