0% found this document useful (0 votes)
140 views5 pages

Digital Calipers Overview and Specs

1) The document discusses various types of calipers including vernier, digital, and carbide-tipped digital calipers. 2) The calipers vary in their measurement ranges from 0-150mm to 0-300mm and measurement accuracies from ±0.001mm to ±0.05mm. 3) Newer calipers features include complete titanium coatings and water-resistant designs to improve durability, protection, and longevity.

Uploaded by

teguh_setiono
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views5 pages

Digital Calipers Overview and Specs

1) The document discusses various types of calipers including vernier, digital, and carbide-tipped digital calipers. 2) The calipers vary in their measurement ranges from 0-150mm to 0-300mm and measurement accuracies from ±0.001mm to ±0.05mm. 3) Newer calipers features include complete titanium coatings and water-resistant designs to improve durability, protection, and longevity.

Uploaded by

teguh_setiono
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

CALIPERS

Micron Digital Calipers 0,001mm


– VERNIER, DIAL AND DIGITAL

Vernier Calipers 0,02mm

With Large LCD display for easy reading, this instrument


uses a totally new, high accuracy capacitive sensor, a
latest innovation in electronic measuring, to make its
resolution be up to 0.001mm. Measurement can reach
higher accuracy.
Measurement Measurement
Item No. Measurement Accuracy Item No. Measurement Range Accuracy
Range 110-011 0 – 50mm ±0,005
140-101 0-150mm ±0.02mm 110-012 50 – 100mm ±0,007
140-102 0-200mm ±0.03mm 110-013 100 – 150mm ±0,009
140-103 0-300mm ±0.04mm Resolution 0.001mm ( Micron Digital caliper).
·Special vernier section structure anvoids parallax error for Used for measuring the work piece demanding higher
easy reading and more accurate measuring accuracy.
·Prevents vernier slide loosening to avoid error Excellent for differential measurement (comparison
·Permit repeated repairs & improved longevity measurement) of the OD, ID, groove, steps, depth (with
bridge base), etc. of a work piece.
Digital Calipers 0,02mm Zero-setting at any position.
Inch/mm conversion.
Data output.

High Precision Digital Calipers


0,005mm

Measurement
Item No. Measurement Accuracy
Range
171-251 0-150mm ±0.02mm
171-252 0-200mm ±0.03mm
171-253 0-300mm ±0.04mm Jaw length -051=40mm -052=50mm -53=60mm
·Shockproof Measurement
·Clear and direct reading Item No. Measurement Range Accuracy
·Outside, inside, depth and step measurement 110-051 0 – 150mm ±0,015
·Available with carbide-tipped measuring faces to improve
110-052 0 – 200mm ±0,02
the durability and longevity
110-053 0 – 300mm ±0,025
Digital Calipers 0,0mm Zero-setting at any position.
Inch/mm conversion.
Data Output.
Absolute and relative measurement conversion at any
position.

Carbide-tipped Digital Calipers

Measurement
Item No. Measurement Range Accuracy
171-101 0-150mm ±0.02mm
170-101 0-150mm ±0.02mm
171-102 0-200mm ±0.03mm
170-102 0-200mm ±0.03mm
171-103 0-300mm ±0.04mm Measurement
N.B. Type 170 has 2mm / revolution and type 170 1mm
Item No. Measurement Range Accuracy
·Shockproof 111-251 0 – 150mm ±0,02
·Clear and direct reading 111-252 0 – 200mm ±0,03
·Outside, inside, depth and step measurement
111-253 0 – 300mm ±0,04
·Available with carbide-tipped measuring faces to improve
·Carbide-tipped measuring faces to improve the durability
the durability and longevity.
and longevity
·The internal jaws measurement accuracy accord with
DIN862
·Zero-setting at any position
·Data output
Complete Titanium Coated Digital Calipers
IP54 Damp Proof Digital Calipers

Measurement
Item No. Measurement Range Accuracy
111-261 0 – 150mm ±0,02
111-262 0 – 200mm ±0,03
111-263 0 – 300mm ±0,04
·IP54 Level: protection against harmful dust and water
111-101T Golden 111-102T Black
splashes.
Measurement
·Can be used after cleaning the water splashes Item No. Measurement Accuracy
·The internal jaws measurement accuracy accord with Range
DIN862
111-101T 0 – 150mm ±0,02
·Zero-setting at any position
111-102T 0 – 150mm ±0,02
TiAlN or TiN coating to improve durability and working life.
Titanium coating the complete surface of caliper, such
IP67 Water-Resistant Digital Calipers as the front and rear master bar and the jaws gives the
caliper a thorough protection, which significantly increases
the performance of antirust and wear resistance and
prolongs its working life. Therefore a complete titanium
coated electronic caliper is cost-effective.
Slide calipers inside and outside measuring faces are
worn gradually with frequent use. The worn measuring
faces lessen the measurement accuracy. In order to
improve the performance of a slide caliper, tungsten
Measurement carbide is welded on the jaws. Tungsten carbide is so
Item No. Measurement Range Accuracy brittle that the tungsten carbide tipped jaws are easily
111-281 0 – 150mm ±0,02 broken when bumped during use, which hinders its
popularity.
111-282 0 – 200mm ±0,03
Recently in the market the slide caliper coated with
111-283 0 – 300mm ±0,04
titanium on the upside and underside of master bar
·Waterproof, oil-proof, anti-electromagnetic interference,
appeared. However, other important contact surfaces,
protection Level IP67 (CEI 60529)
remained uncoated. These slide caliper still can’t
·One-button design, menu prompt, simple, convenient and
significantly improve the performance of antirust and wear
easy to operate.
resistance for all its surfaces.
·Manual / automatic power switch. automatic shutdown
By using an innovative method, complete titanium
after 5 minutes without being used
coated electronic caliper has its master bar and all its
(Note: Some models will automatically reboot at a 16-hour
measuring faces coated with TiN or TiAlN, increasing the
shutdown when the slider is moved.)
wear resistance significantly.
·Low-voltage alarm, high and low temperature, and other
error alarm.
·Infinite response speed, no speed error.
·ABS / INC mode and metric / inch system conversion. Pocket Digital Calipers 0,01mm

Left-Hand Digital Calipers

Measurement
Item No. Measurement Range Accuracy
111-075 0 – 75mm ±0,02
111-100 0 – 100mm ±0,02
Measurement
Item No. Measurement Range Accuracy
111-221 0 – 150mm ±0,03
111-222 0 – 200mm ±0,03
111-223 0 – 300mm ±0,04
Designed for left-handed use
Digital Calipers without upper jaws (Type D) Digital Welding Gauges 0,01mm
0,01mm

Measurement
Item No. Measurement Range Accuracy Measurement
111-703 0 – 300mm ±0,04 Item No. Measurement Range Accuracy
111-705 0 – 500mm ±0,04 118-201 0 – 12,5mm ±0,03
111-706 0 – 600mm ±0,04 118-202 0 – 20mm ±0,03
111-708 0 – 800mm ±0,05 ·used for measuring welding within industry - auto,
111-710 0 – 1000mm ±0,05 shipping, boiler, etc.
·Measure the height of the welding.
111-711 0 – 1500mm ±0,08
·Testing the angle of the groove (four contrast sample
plate with angles of 60, 70 , 80 and 90 degrees are
provided).

Digital Inside and Outside Snap Gauges

Digital Spline Gauges 0,01mm

Inside from Ø5mm


Measurement
Item No. Measurement Range Accuracy
315-221 0 – 30mm (0,001mm) ±0,003
Measurement
315-211 0 – 30mm (0,005mm) ±0,005 Item No. Measurement Range Accuracy
315-201 0 – 30mm (0,001mm) ±0,009
119-601 0 – 25mm ±0,03
·Light weight, small size, easy to operate with one hand.
119-602 0 – 50mm ±0,03
·Easy to use in narrow space.
Used to measure the depth of spline on workpiece.
·Zero-setting at any position.
Used to measure the height of convex part on a surface.
·Inch/ Metric conversion. mm/inch conversion
Zero-setting at any position.
With data output

Digital Snap Gauges

Gap & Step Gauges 0,01mm

315-111
Measurement
Item No. Measurement Range Accuracy
Measurement
315-121 0 – 30mm (0,01mm) ±0,03 Item No. Measurement Range Accuracy
315-111 0 – 30mm (0,005mm) ±0,02
118-901 0 – 12,7mm ±0,03
315-101 0 – 30mm (0,001mm) ±0,009
·Widely used for checking the surface in the auto industry
·Light weight, small size, easy to operate with one hand.
and other various application measurements.
·Easy to use in narrow space.
·Measure the step height and gap width of two curved
·Zero-setting at any position.
surfaces.
·Inch/ Metric conversion.
·Lightweight and easy to operate.
·Data output.
Digital Depth Gauges (Double Hooks) Digital Calipers with Broad
0,01mm Measuring Faces 0,01mm

Measurement
Item No. Measurement Range Accuracy
112-801 0 – 150mm ±0,03
Bridge length 100mm -1=150mm 112-802 0 – 200mm ±0,04
Measurement 112-803 0 – 300mm ±0,05
Item No. Measurement Range Accuracy Extra large measuring faces for soft materials (rubber,
123-201 0 – 150mm ±0,03 paper, cardboard etc.) and wire diameters.
Rigid measuring.
123-201-1 0 – 150mm ±0,03
Zero-setting at any position.
123-202 0 – 200mm ±0,03
Measuring face dimension can be customized.
123-202-1 0 – 200mm ±0,03
123-203 0 – 300mm ±0,04
123-203-1 0 – 300mm ±0,04 Tube Thickness Digital Calipers
·Grove depth measurement.
·Hook types can measure groove width and position of a
groove.
·Zero-setting at any position.

Measurement
Pocket Digital Calipers 0,01mm Item No. Measurement Range Accuracy
114-101 0 – 150mm ±0,03
114-102 0 – 200mm ±0,04
114-103 0 – 300mm ±0,05
·Depending on the hardness of workpieces, a long and
short anvil are available
·Long cavity mould anvil for measuring the soft materials,
such as plastic; and short anvil for measuring hard
Measurement tubular tools including metal tubes, porcelain tubes etc.
Item No. Measurement Range Accuracy
111-075 0 – 75mm ±0,02
360O Rotatable Jaw Calipers 0,01mm
111-100 0 – 100mm ±0,02

Digital Calipers without upper jaws (Type D)


0,01mm

Measurement
Item No. Measurement Range Accuracy
111-703 0 – 300mm ±0,04 Digital Type
Measurement
111-705 0 – 500mm ±0,04 Item No. Measurement Range Accuracy
111-706 0 – 600mm ±0,04
115-301 0 – 150mm ±0,04
111-708 0 – 800mm ±0,05
115-302 0 – 200mm ±0,05
111-710 0 – 1000mm ±0,05
115-303 0 – 300mm ±0,06
111-711 0 – 1500mm ±0,08
115-305 0 - 500mm ±0,08
Vernier Type
145-301 0 – 150mm ±0,04
145-302 0 – 200mm ±0,05
145-303 0 – 300mm ±0,06
145-305 0 - 500mm ±0,08
Outside Groove Calipers with Round Points Straight Moving Digital Micron Caliper
0,001mm

The caliper shown is No. 112-102


The jaw length and point length are available in 3 Measurement
standard sizes. Item No. Measurement Range Accuracy
Measurement 119-011 0-25mm ±0,004
Item No. Measurement Accuracy It looks like a micrometer, accords with the Abbe's
Range principle. It is the combination of calipers and
112-101 0 – 150mm ±0,04 micrometers.
112-101-1 0 – 150mm ±0,04 However it does not operate as a micrometers. Simply
112-101-2 0 – 150mm ±0,04 operate it in a caliper form for quick, convenient
accuracy.
112-102 0 – 200mm ±0,05
High processing accuracy due to super precision linear
112-102-1 0 – 200mm ±0,05
motion adapted in vernier slide and beam.
112-102-2 0 – 200mm ±0,08
112-103 0 – 300mm ±0,04
112-103-1 0 – 300mm ±0,04
112-103-2 0 – 300mm ±0,04
Digital Height Gauge with Double
112-105 0 – 500mm ±0,05
Datum Surfaces 0,01mm
112-105-1 0 – 500mm ±0,05
112-105-2 0 – 500mm ±0,08
·Measures the external groove and tube wall thickness
·Zero-setting at any position
·Data output

Internal Spacing Groove Digital Calipers

Measurement
Item No. Measurement Range Accuracy
131-300 0 – 125mm ±0,03
131-301 0 – 150mm ±0,03
131-302 0 – 200mm ±0,03
Measurement 131-303 0 - 300mm ±0,04
Item No. Measurement Range Accuracy Both the upside and the underside of the base are datum
113-401 3 – 150mm ±0,03 surfaces. The slider has jaws on the left and right side.
113-402 3– 200mm ±0,03 The jaw on the slider's left is for the bottom measuring
face. The jaw on the slider's right is for the upside
113-403 4 – 300mm ±0,04
measuring face. (When the base is on the inspection
·Measures the inside spacing groove width and position of
surface plate, the surface of the plate is regarded as the
a groove
extension of bottom measuring face.)
·Zero-setting at any position
If an inspection surface plate is unavailable, the upside of
·Data output
the base can be used as an inspection surface plate and
measurement can still be done with the slider's right jaw.
The range of application can be widened with various
attachments.

[Link]
[Link]