100% found this document useful (2 votes)
1K views3 pages

Sewage Treatment Plant Layout Plan

The document contains an architectural floor plan with elevation views. It shows a ground floor and level 99.60 with rooms labeled 1 through 20 and sections cut at A-A, B-B, and C-C. Dimensions are provided for rooms, walls, and openings on the ground floor and level 99.60.

Uploaded by

Sherman Lopez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
1K views3 pages

Sewage Treatment Plant Layout Plan

The document contains an architectural floor plan with elevation views. It shows a ground floor and level 99.60 with rooms labeled 1 through 20 and sections cut at A-A, B-B, and C-C. Dimensions are provided for rooms, walls, and openings on the ground floor and level 99.60.

Uploaded by

Sherman Lopez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

102.80 GROUND FLOOR 100.00 LEVEL

9
6 STP CONTROL ROOM STP CONTROL ROOM

15
99.60 99.60 10 99.60 99.60

98.80 99.00 99.00


1
17
I.L. 98.80 98.50
13
98.20
97.60
200 x 200
200 x 200 OPENING
OPENING 4 I.L. 98.20
12
3
11 5
2 600 x 600 OPENING 96.00

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


600 x 600
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

OPENING 95.60
20
94.8 95.00 95.00 95.00

SECTION AT "A-A" SECTION AT "B-B" SECTION AT "C-C"

3900 3400 7700

200 x 200

2350
OPENING 99.60 LEVEL
600
1700

9
B 600 x 600
4
B B B
OPENING 8
10
200 x 200 OPENING
1000 3000

21 18 5
C C C C

5000
3900

3
1500

12 99.60 LEVEL
7
2

14 15
600 x 600 STP CONTROL ROOM
19
OPENING UNDER
A A
2700

A BAFFLE
2000 11
A
6
600

600

1
23
3300 3100 2700 12200
8350
13 95.00 LEVEL
RAW SEWAGE INLET 22

LEGEND PLAN AT 99.00 LEVEL PLAN AT 100.00 LEVEL

1 SCREEN CHAMBER LEGEND


2 EQUALIZATION TANK
3 MOVABLE BED BIOFILM REACTOR (MBBR) HEAVY DUTY PRECAST RCC
4 SETTLING TANK COVER
5 TERTIARY FEED TANK
6 MULTIGRADE SAND FILTER (MGF) ALL DIMENSIONS ARE IN MM
7 ACTIVATED CARBON FILTER (ACF) & LEVELS ARE IN METER
8 SOFTNER
9 ULTRA FILTRATION PLANT (UF)
10 ULTRAVIOLET DISINFECTION SYSTEM
11 CLEAR WATER TANK
12 SLUDGE HOLDING TANK
13 BAR SCREEN (STAINLESS STEEL)
14 RAW SEWAGE SUBMERSIBLE PUMPS
15 TWIN LOBE AIR BLOWERS
16 AERATED SEWAGE OUTFLOW &
VAIDYA ORGANISATION INDORE
MOVABLE MEDIA ARRESTOR
17 90 DEGREE "V" NOTCH FOR FLOW MEASUREMENT 100 KLD CAPACITY SEWAGE TREATMENT PLANT
FOR NEW INDUSRIAL AREA AT VILL. RANGWASA, DISTRICT: INDORE [M.P]
18 TERTIARY FEED PUMPS (OPEN WELL SUBMERSIBLE)
19 CLEAR WATER REUSE / DISPOSAL PUMPS CLIENT EXECUTIVE ENGINEER , MP AKVN, INDORE
(OPEN WELL SUBMERSIBLE)
20 SLUDGE PUMPS (CENTRIFUGAL END SUCTION)
21
22
23
SLUDGE PUMPS (SUBMERSIBLE)
FILTER PRESS FOR SLUDGE DRYING
ELECTRIC CONTROL PANEL
SEWAGE TREATMENT PLANT GENERAL ARRANGEMENT DRAWINGS NTS

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

OVERHEAD TANK
TO FLUSHING
9
15 23 6 7 8 10 TO HORTICULTURE /
FLOOR WASHING /
DISPOSAL INTO
MUNICIPAL SEWER

16 17
RAW SEWAGE
INLET
1 13

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

4 5 11

3
14 19
18

20

FROM 15

LEGEND LEGEND
1 SCREEN CHAMBER SEWAGE PIPE LINE 22
2 EQUALIZATION TANK
3 MOVABLE BED BIOFILM REACTOR (MBBR) AIR PIPE LINE
4 SETTLING TANK
5 TERTIARY FEED TANK SLUDGE PIPE LINE
6 MULTIGRADE SAND FILTER (MGF)
7 ACTIVATED CARBON FILTER (ACF) MGF BACKWASH, ACF REGENERATION,
8 SOFTNER UF WASTEWATER PIPE LINES TO MUNICIPAL 12
9 ULTRA FILTRATION PLANT (UF) SEWER & SLUDGE FILTRATE PIPE LINE
10 ULTRAVIOLET DISINFECTION SYSTEM TO EQUALIZATION TANK
11 CLEAR WATER TANK
12 SLUDGE HOLDING TANK AIR DIFFUSERS (PLATE / TUBE TYPE)
13 BAR SCREEN (STAINLESS STEEL)
14 RAW SEWAGE SUBMERSIBLE PUMPS BALL VALVE / GATE VALVE
15 TWIN LOBE AIR BLOWERS 21
16 AERATED SEWAGE OUTFLOW & NON RETURN VALVE
MOVABLE MEDIA ARRESTOR
17 90 DEGREE "V" NOTCH FOR FLOW MEASUREMENT MOVABLE BIO FILM MEDIA
18 TERTIARY FEED PUMPS (OPEN WELL SUBMERSIBLE)
19 CLEAR WATER REUSE / DISPOSAL PUMPS MULTI PORT VALVE
(OPEN WELL SUBMERSIBLE)
20 SLUDGE PUMPS (CENTRIFUGAL END SUCTION)
21 SLUDGE PUMPS (SUBMERSIBLE)
22 FILTER PRESS FOR SLUDGE DRYING
23 ELECTRIC CONTROL PANEL

SEWAGE TREATMENT PROCESS & INSTRUMENTATION DRAWING NTS

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

CONTR
AKVN LEGEND
13 LEGEND
15
1 SCREEN CHAMBER EFFLUENT PIPE LINE
2 OIL & GREASE SKIMMING TANK
CONTR
AKVN

1 2 3 3 EQUALIZATION TANK AIR PIPE LINE


7 16 4 SEQUENTIAL BATCH REACTOR (SBR) - 1
14
5 SEQUENTIAL BATCH REACTOR (SBR) - 2 SLUDGE PIPE LINE
6 TREATED WATER TANK
7 OIL PIT SLUDGE FILTRATE PIPE LINE
8 OIL DECANTER
9 SLUDGE TANK CHEMICAL SOLUTIONS PIPE LINE
a b SKIMMED OIL
10 NUTRIENT TANK - 1
FROM UNIT 7 FRESH WATER PIPE LINE
10 11 11 NUTRIENT TANK - 2
12 DISINFECTANT (HYPO) SOLUTION TANK
AIR DIFFUSERS (PLATE / TUBE TYPE)
23 8 13 BAR SCREEN WITH MECHANICAL
18 CLEANING ARRANGEMENT BUTTERFLY / GATE VALVE
14 "T" SIPHONS
15 SURFACE OIL SKIMMER NON RETURN VALVE

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


16 EFFLUENT PUMPS (SUBMERSIBLE,
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

1 WORKING + 1 STANDBY) NOZZLE FOR CONNECTING FLEXIBLE PIPE


17 TREATED EFFLUENT DECANTING EQUIPMENT
18 TWIN LOBE AIR BLOWERS a FLEXIBLE HOSE PIPE FOR AERATION
(1 WORKING + 1 STANDBY)
19 b

CONTR
19 "V" NOTCH FOR FLOW MEASUREMENT FLEXIBLE HOSE PIPE FOR FRESH WATER

AKVN
20 TREATED EFFLUENT REUSE PUMP
12 21 SLUDGE PUMPS (SUBMERSIBLE,
4 5 17
1 WORKING + 1 STANDBY)
22 FILTER PRESS FOR SLUDGE DRYING
23 ELECTRIC CONTROL PANEL

CONTR
AKVN
6

20
TO UNIT 3

22

9
21

PROCESS & INSTRUMENTATION DRAWING

NTS

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

2350
PLAN AT 100.00  LEVEL
600
2000
3900
3400
3900
1700
3300
3100
2700
1500
2700
600
600
1
2
3
4
5
11
12
RAW SEWAG
14
NTS
1
13
SEWAGE TREATMENT PROCESS & INSTRUMENTATION DRAWING
6
7
8
16
18
19
22
23
15
2
3
4
5
11
12
9
10
17
21
20
FROM 15
1
2
14
3
8
7
5
19
6
9
22
10
11
12
18
23
15
a
b
SKIMMED OIL
FROM UNIT 7
16
CONTR
AKVN
CONTR
AKVN
AIR DIFFUSERS (PLATE / TUBE TYP

You might also like