0% found this document useful (0 votes)
2K views2 pages

Volume Correction Factor Calculation Guide

1. The document contains density, temperature, and flow rate data for 3 samples. 2. The user is instructed to choose the column related to density, enter it in yellow cells, and the VCF (volume correction factor) will then be automatically calculated in the green cell. 3. Additional calculations are shown for the weight correction factor (WCF) and actual flow in terms of m3/hr and tonnes per day (TPD).

Uploaded by

rvkumar61
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

Volume Correction Factor Calculation Guide

1. The document contains density, temperature, and flow rate data for 3 samples. 2. The user is instructed to choose the column related to density, enter it in yellow cells, and the VCF (volume correction factor) will then be automatically calculated in the green cell. 3. Additional calculations are shown for the weight correction factor (WCF) and actual flow in terms of m3/hr and tonnes per day (TPD).

Uploaded by

rvkumar61
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
  • Technical Data Analysis: This section provides detailed calculations and analysis of technical data, organized in tables displaying parameters such as density, temperature, and flow rates.
  • Continued Data Analysis: Continues the data analysis with additional numerical data, focusing on variable calculations based on previous datasets.

Density @ 15 C Kg/liter >= 839 >= 778 & < 839 >= 770 & < 778

Actual Den. @ 15 C Kg/liter 1045 815 775


K0 186.9696 594.5418 -0.0033612
K1 0.48618 0 2680.32
Alpha 0.00063646 0.000895091 0.0011013515
Actual Temp DegC 160 148.9 148.9
Del T 145 133.9 133.9
-0.0990998 -0.1313444131 -0.1648691159
VCF 0.90565 0.87692 0.84800

1. Choose column related to density


2. Enter in yellow cells
3. VCF (green cell) is calculated

WCF 1.0439 0.8139 0.7739

Actual Flow m3/hr 36.5 36.5 36.5


TPD 828.18 625.22 574.89
< = 770
750
346.42278
0.43884
0.0012009827
148.9
133.9
-0.1814998792
0.83402

0.7489

36.5
547.15