Stud Range
Stud Range
80 80 SW60
• An Interrupted current is when a switch is used to open and close on load. Frequent switching of load current can result in increased
contact resistance, which therefore may affect the contactor thermal current rating.
• An Uninterrupted current is when a switch has no or limited load switching requirements and maintains a lower contact resistance.
Our stud contactors feature double breaking main contacts with silver alloy contact tips, which are weld resistant, hard wearing and
have excellent conductivity. Furthermore, they are not polarity sensitive and therefore can be used for switching A.C. currents. Electrical
connections follow industry standards, with 4.7mm or 6.3mm spades, plug or screw terminal fitting or flying leads. The series include
type configurations that are suitable for Normally Open, Normally Closed, Single or Double Throw and Motor Reversing applications
as well as full customisation options.
Spare Parts
A full range of spare parts for servicing of existing Albright stud range
contactors are available. These include contacts, top covers and coil
assemblies, and additionally we offer complete spare contact kits.
P type contactors e.g. SW80P, are non-serviceable, as disassembling
the contactor compromises their IP66 seal.
ISO 9001
Registered
Quality
Management
ISO 14001: EMS 54527 Please check web
CERT: 5908 site for UL status
[Link]
Albright International Stud Contactor Range
The options featured are available for our stud contactor series. For full descriptions, please refer to our Product Range catalogue
or web site glossary.
Fuseholder
Armature Cap
Auxiliary Contacts Large & Textured Contact Tips Magnetic Blowouts Amp Tags M5 Terminal Board Flying Leads Plug Connection Protected ‘P’ Type
Our stud contactor range is divided into series and then grouped into types based on thermal current specfication which are Coil voltages ranging from 6 to 240v are available which are wound for D.C. operation. However, the majority of coils can be fitted
comprised of contactor configurations e.g. Single Pole, Single Throw. The part number is completed by a unique identity number with a bridge rectifier for use with A.C. supplies. Coils are wound with pull-in voltages (coils at 20°C) approximately 66% of the
and the specification of the contactor indicated by letter suffixes. The diagram below details the options and associated suffixes rated voltage (Continuous) or 60% (Prolonged, Intermittent Or Very Intermittent), and drop-out voltage nominally greater than 10%
which are relevant to the stud contactor range. For a detailed description of options refer to the Albright Product Range Catalogue. of the rated voltage. Variations from these pull-in and drop-out figures can be engineered to suit particular applications.
V3 Auxiliary Flying Leads Large • 100% duty cycle. Continuous operation. Weakest power • Up to 90% duty cycle, up to 54 minutes continuous
Contacts Fitted Fitted Contact Tips coil dictating that a weaker, when compared to the energisation. Coil is more powerful than continuous,
intermittent equivalent, return spring is used. This does weaker than intermittent equivalent. The return spring is
not give the best switching characteristics for applications stronger than continuous but weaker than intermittent.
switching frequently on load.
SW80 A or C B EE E F N R - 43 L M P T
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire RG28 7BB, UK E-mail: sales@[Link] or technical@[Link]
2 Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562 Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 Web Site: [Link] 3
Albright International Stud Contactor Range
SW60 Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary
Description Blowouts ‘B’ 1
Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts5 Enclosed Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug4
Current Current Cap8 High Housing Brackets6 Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V4) Normal ‘E’ ‘P’ Tips ‘L’ Board ‘F’ Operation
Powered
SW60 Single Pole Single Throw Normally Open 80 Amperes X ○ ○ ○ X ○7 ○ ○ X ○ X X X ○ X X ○ X ○ X
DC66P Monoblock, Single Pole Double Throw for Motor Reversing - IP66 compliant 80 Amperes X X X X X ● ● ○ X ● X X X ○ X X ○ X X X
SW80 Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary
Description Blowouts ‘B’1 Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts5 Enclosed Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug4
Current Current Cap High Housing Brackets6 Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V3) Normal ‘EE’ ‘P’ Tips ‘L’ Board ‘F’5 Operation
Powered
SW80 Single Pole Single Throw Normally Open 100 Amperes 125 Amperes ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW82 Double Pole Single Throw Normally Open 100 Amperes ○ X X X X ○9 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW822 Paired Double Pole Single Throw for Motor Reversing 100 Amperes ○ X X X X ○9 ● ○ X ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW84 125 Amperes N/O
Single Pole Double Throw 100 Amperes
100 Amperes N/C ○ ○ ○ ○ ○ ○ ○ ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW85 Single Pole Single Throw Normally Closed 100 Amperes X ○ ○ ○ ○ ○ ○ X ○ ○ ○ ○ ○ ○ ○ X P ○ ○ ○
SW86 125 Amperes N/O
2 x SW84 100 Amperes
100 Amperes N/C ○ ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
DC88 Monoblock Single Pole Double Throw for Motor Reversing 100 Amperes ○ ○ X ○ ○ ○ 9
● ○ ○ ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW88 2 x SW84 on Common Bracket for Motor Reversing 100 Amperes ○ ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
DC90 125 Amperes N/O
Monoblock, 1 x SW80 & 1 x SW84 100 Amperes
100 Amperes N/C ○ ○ X ○ ○ ○ 9
● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW90 125 Amperes N/O
1 x SW80 & 1 x SW84 on Double Bracket 100 Amperes
100 Amperes N/C ○ ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
DC92 Monoblock, 2 x SW80 100 Amperes 125 Amperes ○ ○ X ○ ○ ○ 9
● ○ X ○ ○ ○ ○ ○ ○ ○ P X ○ ○
SW92 2 x SW80 on Double Bracket 100 Amperes 125 Amperes ○ ○ ○ ○ ○ ○ ● ○ X ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW93 2 x SW85 on Double Double Bracket 100 Amperes X ○ ○ ○ ○ ○ ● X X ○ ○ ○ ○ ○ ○ X P ○ ○ ○
SW95 1 x SW80 + 1 x SW82 100 Amperes ○ ○ 8
○ 8
○ 8
○ 8
○ 9
● ○ X ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SW96 1 x SW80 + 1 x SW85 100 Amperes ○8 ○ ○ ○ ○ ○ ● ○3,8 X ○ ○ ○ ○ ○ ○ ○8 P ○ ○ ○
Key: Optional ○ Standard ● Not Available X Optional for P Type Only P
1
Main contacts may become polarity sensitive, refer to + positive marking on the contactor top cover, 2 Coil connection becomes polarity sensitive, 3 Magnetic Latching not suitable for Normally Closed - please select Normally Open equivalent, 4 Plug to fit Tyco part 282189 (female component). Not compatible with P types, 5 Auxiliaries not available for ‘P’ types,
6
All ‘P’ types fitted with bracket (refer to individual catalogue data sheets for details), 7 Flying Leads cannot be added to ‘P’ type contactors unless soldered to the spades or separate cable assembly applied 8 On SW80 side only, 9 Dust shields on Double Pole and Paired variants,
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire RG28 7BB, UK E-mail: sales@[Link] or technical@[Link]
4 Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562 Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 Web Site: [Link] 5
Albright International Stud Contactor Range
SW120 Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary
Description Blowouts ‘B’ 1
Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts Dust Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug
Current Current Cap High Shields Brackets Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V3) Normal ‘E’ ‘P’ Tips ‘L’ Board ‘F’ Operation
Powered
SW120 Double Pole Single Throw Normally Open 125 Amperes ○ ○ ○ X X ○ ○ ○ X X ○ ○ ○ ○ ○ ○ X ○ X ○
SW121 125 Amperes N/O 125 Amperes N/O
Double Pole Double Throw
100 Amperes N/C 125 Amperes N/C
X ○ ○ X X ○ ○ ○ X X ○ ○ ○ ○ ○ X X ○ X ○
SW122 2 x SW120 on Common Bracket for Motor Reversing 125 Amperes ○ ○ 4
○ 4 X X ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ X ○
SW123 125 Amperes N/O 125 Amperes N/O
2 x SW121 on Common Bracket
100 Amperes N/C 125 Amperes N/C
X ○ ○ X X ○ ● ○ X X ○ ○ ○ ○ ○ X X ○ X ○
SW132 Double Pole Single Throw Normally Closed 100 Amperes ○ ○ ○ X X ○ ○ X 3 X X ○ ○ ○ ○ ○ X X ○ X ○
SW133 2 x SW132 on Common Bracket 125 Amperes ○ ○ ○ X X ○ ● X3 X X ○ ○ ○ ○ ○ X X ○ X ○
Key: Optional ○ Standard ● Not Available X
1
Main contacts may become polarity sensitive, refer to + positive marking on the contactor top cover, 2 Coil connection becomes polarity sensitive, 3 Magnetic Latching not suitable for Normally Closed - please select Normally Open equivalent, 4 Links cannot be fitted when ‘A’ or ‘C’ auxiliary fitted.
Note: Two Special versions, SW121E and SW132E are available. These contactors are designed for mains failure changeover duty and are fitted with economy resistors which are intended for continuous energisation with minimum coil power consumption.
SW180 Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary Enclosed
Description Blowouts ‘B’ 1
Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts Housing/ Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug4
Current Current Cap High Dust Brackets Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V3) Normal ‘E’ ‘P’ Tips ‘L’ Board ‘F’ Operation
Powered Shields
SW180 Single Pole Single Throw Normally Open 150 Amperes 200 Amperes ● ○ ○ ○ ○ ○ ○ ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW181 200 Amperes N/O
Single Pole Double Throw 150 Amperes
150 Amperes N/C ● ○ ○ ○ ○ ○ ○ ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
DC182 Monoblock Single Pole Double Throw for Motor Reversing 150 Amperes ● ○ ○ ○ ○ ○ ● ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW182 200 Amperes N/O
2 x SW181 on Common Bracket for Motor Reversing 150 Amperes
150 Amperes N/C ● ○ ○ ○ ○ ○ ● ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
DC184 Monoblock, 2 x SW180 150 Amperes 200 Amperes ● ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW184 2 x SW180 on Common Bracket 150 Amperes 200 Amperes ● ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW185 Single Pole Single Throw Normally Closed 150 Amperes X ○ ○ ○ ○ ○ ○ X3 ○ X ○ ○ ○ ○ ○ X X ○ ○ ○
SW188 200 Amperes N/O
2 x SW181 or 1 x SW181 + 1 x SW180 150 Amperes
150 Amperes N/C ● ○ ○ ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW189 2 x SW185 on Common Bracket 150 Amperes X ○ ○ ○ ○ ○ ● X3 X X ○ ○ ○ ○ ○ X X ○ ○ ○
SW190 Double Pole Single Throw Normally Open 150 Amperes 200 Amperes ● ○ ○ ○ ○ ○ ○ ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW192 2 x SW190 on Common Bracket for Motor Reversing 150 Amperes 200 Amperes ● ○5 ○5 ○ ○ ○ ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SW195 Double Pole Single Throw Normally Closed 150 Amperes X ○ ○ ○ ○ ○ ○ X3 ○ X ○ ○ ○ ○ ○ X X ○ ○ ○
Key: Optional ○ Standard ● Not Available X
1
Main contacts may become polarity sensitive, refer to + positive marking on the contactor top cover, 2 Coil connection becomes polarity sensitive, 3 Magnetic Latching not suitable for Normally Closed - please select Normally Open equivalent, 4 Plug to fit Tyco part 282189 (female component). Not compatible with ‘P’ types, 5 Links cannot be fitted when ‘A’ or ‘C’ auxiliary fitted
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire RG28 7BB, UK E-mail: sales@[Link] or technical@[Link]
6 Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562 Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 Web Site: [Link] 7
Albright International Stud Contactor Range
SW200 Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary Enclosed
Description Blowouts ‘B’1
Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts Housing/ Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug
Current Current Cap High Dust Brackets Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V3) Normal ‘E’ ‘P’ Tips ‘L’ Board ‘F’ Operation
Powered Shields
SW200 Single Pole Single Throw Normally Open 250 Amperes 400 Amperes ● ○ ○ ● ○ ○ ○ ○ ○ X X ○ ○ ○ ○ ○ X ○ X ○
400 Amperes N/O
SW201 Single Pole Double Throw 250 Amperes
250 Amperes N/C ● ○ ○ ● ○ ○ ○ ○ ○ X X ○ ○ ○ ○ ○ X ○ X ○
SW202 2 x SW201 on Common Bracket for Motor Reversing 250 Amperes ● ○ ○ ● ○ ○ ● ○ ○ X X ○ ○ ○ ○ ○ X ○ X ○
SW204 2 x SW200 on Common Bracket 250 Amperes 400 Amperes ● ○ ○ ● ○ ○ ● ○ X X X ○ ○ ○ ○ ○ X ○ X ○
400 Amperes N/O
SW205 2 x SW201 on common Bracket 250 Amperes
250 Amperes N/C ● ○ ○ ● ○ ○ ● ○ X X X ○ ○ ○ ○ ○ X ○ X ○
SW208 3 x SW200 on Common Bracket 250 Amperes 400 Amperes ● ○ ○ ● ○ ○ ● ○ X X X ○ ○ ○ ○ ○ X ○ X ○
SW210 Single Pole Single Throw Normally Closed 250 Amperes X ○ ○ ● ○ ○ ○ X3 ○ X X ○ ○ ○ ○ X X ○ X ○
SW213 3 x SW210 on Common Bracket 250 Amperes ● ○ ○ ● ○ ○ ● X 3 X X X ○ ○ ○ ○ X X ○ X ○
SW214 2 x SW210 on Common Bracket 250 Amperes X ○ ○ ● ○ ○ ● X3 X X X ○ ○ ○ ○ X X ○ X ○
SW215 Single Pole Double Throw Normally Closed on Stud Contacts 250 Amperes ● ○ ○ ● ○ ○ ○ ○ ○ X X ○ ○ ○ ○ ○ X ○ X ○
Key: Optional ○ Standard ● Not Available X
1
Main contacts may become polarity sensitive, refer to + positive marking on contactor top cover, 2 Coil connection becomes polarity sensitive, 3 Magnetic Latching not suitable for Normally Closed - please select Normally Open equivalent
Note: Normal blowouts fitted as standard for the SW200 series, where not required ‘N’ is utilised in the part numbering e.g. SW200N-1.
SU Series
Maximum Continuous
General Options Contact Options Coil Options
Current Thermal Rating
Contactor Auxiliary Enclosed
Description Blowouts ‘B’1
Steel Protected Large AC Flying Manual
Type Interrupted Uninterrupted Armature Contacts 5 Housing/ Mounting Magnetic Textured Coil M4 Stud M5 Terminal Vacuum
Shroud to IP66 Contact Rectifier Leads Override Plug4
Current Current Cap High Dust Brackets6 Latching ‘M’2 Tips ‘T’ Suppression2 Terminal Board Impregnation
‘A’ ‘C’ (V3) Normal ‘E’ ‘P’ 5 Tips ‘L’ Board ‘F’ Operation
Powered Shields
SU60 Single Pole Single Throw Normally Open 100 Amperes X ○ X ○ X ●7 ○ ○ X ○ ○ ○ X ○ X X ○ X ○ X
SU80 Single Pole Single Throw Normally Open 150 Amperes 200 Amperes ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ P ○ ○ ○
SU190 Double Pole Single Throw Normally Open 250 Amperes 350 Amperes ● X X ○ ○ X ○ ○ ○ X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SU192 2 x SU190 on Common Bracket for Motor Reversing 250 Amperes 350 Amperes ● X X ○ ○ X ● ○ X X ○ ○ ○ ○ ○ ○ X ○ ○ ○
SU280 Single Pole Single Throw Normally Open 250 Amperes 350 Amperes ● ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ X ○ ○ ○
SU284 2 x SU280 250 Amperes 350 Amperes ● ○ ○ ○ ○ ○ ● ○ X ○ ○ ○ ○ ○ ○ ○ X ○ ○ ○
SU285 Single Pole Single Throw Normally Closed 250 Amperes ● ○ ○ ○ ○ ○ ● X3 ○ ○ ○ ○ ○ ○ ○ X X ○ ○ ○
Key: Optional ○ Standard ● Not Available X Optional for P Type Only P
1
Main contacts may become polarity sensitive, refer to + positive marking on contactor top cover, 2 Coil connection becomes polarity sensitive, 3 Magnetic Latching not suitable for Normally Closed - please select Normally Open equivalent, 4 Plug to fit Tyco part 282189 (female component). Not compatible with ‘P’ types,5 Auxiliaries not available for ‘P’ types,
6
All ‘P’ types fitted with bracket (refer to individual catalogue data sheets for details), 7 Enclosed top cover standard when no blowouts fitted
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire RG28 7BB, UK E-mail: sales@[Link] or technical@[Link]
8 Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562 Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 Web Site: [Link] 9
Albright International Stud Contactor Range
Mounting Bracket Options SW80 Series & SU80 Type Bracket Options
Mounting is by means of tapped holes in the switch frame or with a range of mounting brackets (complete with screws and washers). Top Hat Bracket Kit Integral Bracket Din Rail Bracket Kit ‘L’ Shaped Bracket kit
In the event that these would not be suitable Albright can design and manufacture customer specific solutions. Our most popular
mounting bracket options are detailed as follows. Full outline drawings showing contactor part numbers with fitted bracket are
available on request. Further bracket options are available, contact our Technical Department for information.
SW60 Series
Top Hat Bracket Kit Din Rail Bracket Kit Curved Bracket Kit DC64P/DC66P
Top Hat Bracket Kit
‘D’
‘E’
‘D’
‘B’
‘A’
‘A’
‘B’ ‘A’
‘C’ ‘F’
‘D’
‘C’
‘B’
‘C’
‘B’
‘E’
‘A’
‘D’
‘F’
‘E’
‘B’
‘C’
’A‘
SW88/SW92/DC88/DC88P/DC92/DC92P DC88/DC92 Paired ‘L’
Curved Bracket Kit
Integral & Top Hat Bracket Kit
’A‘
SW64/SW66/SW688
Top Hat Bracket Kit
‘D’
‘D’
’A‘
’A‘
’A‘
‘D’
‘F’
‘B’
‘G’
‘C’
‘A’
‘E’
‘E’ ‘C’ ‘D’ ‘F’
‘E’
‘D’
‘C’
‘B’
‘B’
‘D’
‘E’
‘A’
‘C’
‘B’
‘A’
‘B’
‘C’
‘B’
‘C’
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire RG28 7BB, UK E-mail: sales@[Link] or technical@[Link]
10 Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562 Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 Web Site: [Link] 11
Albright International Stud Contactor Range
‘L’ Shaped Bracket Kit Saucepan Paired Bracket Kit Top Hat Bracket Kit
‘F’
‘D’
‘E’
‘D’
‘A’
‘A’
‘B’
‘C’
‘F’
‘D’
‘C’
‘E’
‘B’
‘A’
‘G’
‘E’
‘B’
‘C’
‘E’
‘C’ ‘D’ ‘F’
‘B’
‘D’
‘E’
‘A’
‘A’
‘B’
‘C’
Contactor Series/Type: SW120, SW180 & SU280 Contactor Series/Type: SW200 & SW202
Saucepan SW182/DC182 SW182/DC182 SW202
Top Hat ‘L’ Shaped Top Hat ‘L’ Shaped Saucepan Paired SW202 Top Hat
Paired Integral & Top Hat ‘L’ Shaped ‘L’ Shaped
Bracket Kit Bracket Kit Bracket Kit Bracket Kit Bracket Kit Bracket Kit
Bracket Kit Bracket Kit Bracket Kit Bracket Kit
Part assigned with Part assigned
Part 2159-47 Part 2155-165 Part 2065-167A Part 2155-165 Part 2028-551A Part 2155-165 Part 2065-167A Part 2 x 2155-165
contactor with contactor
mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches
A 34.0 1.34 64 2.52 41.9 1.65 34*/ 35.9† 1.34*/1.41† 35.4 1.39 A 44.2 1.74 72 2.83 52.0 2.05 42.3 1.66 42.2 1.66
B 61.1 2.40 22.5 0.89 45.8 1.80 105.7*/106.2† 4.16*/4.18† 42.4 1.67 B 75.0 2.95 22.5 0.89 59.5 2.34 133.3 5.25 49 1.93
C 80 3.15 38 1.50 66 2.60 125.1*/125.6† 4.93*/4.94† 22.5 0.88 C 102 4.01 38 1.50 80 3.15 159 6.26 22.5 0.89
D 32 1.26 35.4 1.39 25.4 1.00 31.8 1.25 38.1 1.50 D 32 1.26 42.2 1.66 25.4 1.00 31.8 1.25 38.1 1.50
E 6.5 0.26 Ø6.0 Ø0.24 6.3 0.25 7.1 0.28 84 3.30 E 7.1 0.28 Ø6.0 Ø0.24 6.3 0.25 7.1 0.28 95 3.74
F - - 42 1.65 12.8 0.50 39*/ 38.4† 1.54*/1.51† Ø6.0 Ø0.24 F - - 49.2 1.94 12.8 0.50 47 1.85 Ø6.0 Ø0.24
Please Note: All bracket kits include screws and washers. Brackets can be supplied separately or fitted to contactor at point of manufacture. Integral brackets and brackets for P types factory fitted
only. Contactor CAD Data available on request.
Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire, RG28 7BB, UK
Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562, Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043
12 E-mail: sales@[Link] or technical@[Link] Web Site: [Link] v2-06-13
Copyright © 2013 Albright International LTD