Security
Level:
SingleRAN BSC6910 Introduction
Author/ Email: huangzhihang 00267344
Version: 09(20130902)
HUAWEI TECHNOLOGIES CO., LTD.
Technology Evolution Drives Network Forward
2005
2013
Future
Smartphone , Facebook, Twitter
Feature Phone, Camera, TV
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Anywhere , Anytime, Anything
Page 2
MBB Challenges Managing Signaling and Traffic Growth
Throughput
Traffic
Signaling
Smartphone
Signaling Storm
MBB will keep increasing
Feature Phone
2009
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Smartphone % +++
Apps +++
2015
100% Smartphone
Everything is connected
Page 3
What are the requirements for MBB Controller?
Broad: Large Capacity
Reliability : Quick Disaster Recovery
Smooth: Compatibility & Future Evolution
Effeciency: High Intergration & Common Hardware
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 44
Page
BSC6910 Highlights
BSC6910
Tbps level switching platform for GSM and
Tbps level switching platform for GSM and
UMTS
UMTS
3x User Plane (PS Traffic Model)
3x User Plane (PS Traffic Model)
5x Control Plane (Smartphone Traffic Model)
5x Control Plane (Smartphone Traffic Model)
1 for All Processing Board
1 for All Processing Board
RNC in Pool, smooth evolution
RNC in Pool, smooth evolution
RNC in Pool Redundancy, 10s disaster recovery
RNC in Pool Redundancy, 10s disaster recovery
BSC Node Redundancy , 15 mins disaster
BSC Node Redundancy , 15 mins disaster
recovery
recovery
[kun]
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 5
BSC6910 Logical Architecture & Hardware Unit
Logical Architecture
O
O
M
M
U
U
C
C
LL
K
K
Common
MPU
MPU
GPU
GPU
I/F
I/F
Switching
Switching
Specific
For 6910 only
for 6900/6910
Add
Switching
your text
board
in here
Click
SCUb
to add Text
Common
AddCP/UP
your text
processing
in here board
Click
EGPUa
to add Text
Clock
Add Generation
your text inboards
here
Click
GCUa,
to add
GCGa
Text
10GE interface
Add your
transmission
text in hereboard
Click
EXOUa
to add Text
IP Add
transmission
your text boards
in here
Click
FG2c,
to add
GOUc
Text
O&M
Add interface
your text board
in here
Click
EOMUa
to add Text
ATM
Add
transmission
your text in
boards
here
Click
UOIc,
to add
AOUc
Text
Nastar
Add your
support
text in
board
here
Click
ESAUa
to add Text
TDM Add
/ IP Transmission
your text in here
board
Click
POUc
to add Text
Network
Add your
intelligence
text in here
board
Click
ENIUa
to add Text
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 66
Page
BSC6910 Ready For Cloud Evolution
BCS6910: X86 Hardware Platform,
Ready for Cloud Platform Evolution
BSC
APP
Common X86 Hardware
Architecture, Soft define NE
Evolve to Cloud smoothly , protect
investment
RNC
APP
X86
X86
BSC
RNC
MBS
C
eCo
MBS
CAPP
eCo
APP
Virtualization
OS
X86
Othe
rAPP
X86
X86
X86
X86
X86
X86
X86
Visualization
X86
X86
X86
X86
X86
X86
X86
X86
X86
X86
X86
X86
X86
X86
SDC Software Platform
Common Hardware Platform
X86
Hardware
X86
X86
X86
X86
Future Controller Cloud Architecture:
Hardware virtualization and
Centralized Hardware Deployment
SDC: Soft Define Controller
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 7
Fewer Boards Less CAPEX and OPEX
Existing
BSC6910
O&M
O&M
Clock
Clock
Interface
Interface
GSM CP
GSM UP
EGPU
Board
Categories
-50%
Spare
Parts
-50%
O&M Job
-30%
Reduc
ed
UMTS CP
UMTS UP
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Low Capex & Opex
Page 8
Minimum 1 EGPU for both CP and UP
GSM Specification
UMTS Specification
Fixed Processing CP&UP in One Board
Configurable Processing Capacity for CP&UP
1x
EGPUa
3.2x
1x
XPUb
CP: Signaling Capacity
>500%
>250%
DPUf
SPUb
EGPUa
TRX : 1000
3
PDCH
x:
3000
BHCA: 896K / 1,668K
BHCA: 2200K
ERL:
6250
depending on traffic model
DPUe
EGPUa
DPUg
Throughput: 2Gbps
PUa: Evolved General Processing Unit REV:a . BHCA base on Huawei Traffic model.
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
UP: Data Capacity
Specifications based on Huaweis
traffic models
Page 9
EGPU UMTS Dynamic CP and UP Adjustment
Common Hardware
Resource Auto Adjustment
Traffic Model changes
Board level
UP
Board
Process
level
Load
EGPU
Board
UP UP UP
EGPUa
Board
Single Common hardware & Software
defined for CP or UP
EGPU work as CP (SPUb, XPUb) & UP
(DPUe, DPUg)
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
EGPU
Board
UP 20%
UP 10%
UP 50%
CP CP CP
CP
Board
EGPU
Board
CP 50%
Check
point
Adjustment Time
point
Initial
deployment
CP 80%
CP 90%
Adjustment 1 Adjustment 2
CP/UP Resource Auto Adjustment based on traffic
Model
Increase board efficiency
CP: Control Plane, UP: User Plan
Page 10
10GE board EXOU Simplifies Network Connections
Integration
Telco
capability
Support Allwith
Logical
Interfaces
Evolved 2-port 10GE Optical
interface Unit REV:a
Iub interface
Simplify Physical Network
Connections
Provides two channels over 10 Gbit/s
optical ports
Supports IP over GE
GE port
IuCS interface
IuPS interface
One 10GE port= 10
ports
Iur interface
Iur-g interface
Abis Interface A interface GB Interface
GE Port
10GE port
One interface board for all GU
interfaces
Transmission Pool to simplify
configuration and load
balancing
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Simplify topological network
structure
75% board slots saved!
Page 11
System Reliability Implementation
Board Level Reliability
O
O
O
&
O&
&
&M
M
M
M
C
C
C
C ll
ll oo
oo cc
cc kk
kk
M
M
M
P
MP
P
PU
U
U
U
Active &
Standby
II
N
N
TT
FF
II
N
N
TT
FF
II
N
N
TT
FF
G
G
P
P
U
U
Process Level Reliability
G
G
P
P
U
U
G
G
P
P
U
U
EGPU
C
C
P
P
C
C
P
P
C
C
P
P
Pool
Pool
Backup
Backup
Backup
EGPU
C
C
P
P
C
C
P
P
C
C
P
P
Process level backup
CP Active process
CP
Backup process
Resource Pooling & Process A/S ensures no service impact in case of single board failure.
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 12
Page
12
Automatic CP Resource Allocation
Initial Automatic Resource Allocation (GSM&UMTS)
BSC6910 allocates automatically processing
resources when adding a NodeB, BTS, Cell or
Signaling link such as SCTP.
No manual configuration required.
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Automatic Resource Reallocation (UMTS Only)
When adding more boards to expand capacity or
some NodeB or Cell becoming hot spots, the
system will adjust the distribution of NodeB/Cell in
the EGPUa boards.
Page 13
Transmission Interface Boards Pooling
Interface Boards Pool
Reliability
Of IP
Networking
Rack 0
Load balance
& Efficiency
In the use of
transmission
resources
IP1
NodeB
Rack 1
IP2
IP Network
Rack 2
NodeB
IP3
Serviceabilit
y
Of IP RAN and
RNC
NodeB
BSC
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 14
RNC in Pool, Ready for Cloud Evolution
RNC in POOL Architecture (2013)
RAN
UE
RNC in POOL Architecture (future)
CN
Iu CS
BSC6900
RNC Pool
Iub
NodeB
MSC SERVER
BSC6910
RNC
BSC6900
Iur-p
BSC69
00
NodeB
MGW
RNC
NodeB
Iu PS
SGSN
OSS
BTS
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 15
Page
15
NodeB
MBTS
RNC in Pool solution introduction
RNC in Pool
Iub
RNC
Benefit
NodeB
MSC SERVER
Iur-p
NodeB
New RNC
SGSN
Primary
Standby
RNCs are pooled through Iur-p for node redundancy/load
sharing
Standby links are required
Higher efficiency and
reiliability
Traffic recovery would take
10 Seconds
One key Swapping
Automatic synchronization
of configuration
Redundancy in same or
different place
No KPI lose
Standby RNC software version should be the same or higher
than Primary RNC
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 16
UMTS RNC Hot Backup solution 3*BSC6900+1*BSC6910
3*BSC6900 +1*BSC6910
Iur-p
Iur-p
Specification
Hardware saving by 3+1
Iur-p
RNC 1~3 could be backup by RNC 4
RNC 4
RNC 1
RNC 2
Available for SRAN8.0 or later
Load sharing function can work
together
RNC 3
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 17
UMTS RNC Hot Backup solution 4*BSC6900+2*BSC6910
4*BSC6900+ 2*BSC6910
RNC 1
Specification
RNC 2
Iur-p
Iur-p
RNC 3
Iur-p
RNC 4
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
RNC 5
RNC 6
Hardware saving by 4+2
RNC 3&4 could be backup by RNC 1
RNC 5&6 could be backup by RNC 2
RNC 1&2 could be backup by each
other
Available for SRAN9.0 or later
Load sharing function can work
together
Page 18
UMTS RNC Hot Backup solution BSC6910 1+1
BSC6910 1+1
RNC 2
RNC 1
Iur-p
Specification
RNC products should be BSC6910
RNC capacities should be the
same
Available for SRAN8.0 or later
Load sharing function can work
together
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 19
UMTS RNC Hot Backup solution BSC6910 3+1
BSC6910 3+1
Iur-p
Iur-p
Specification
Iur-p
RNC 4
RNC 1
RNC 2
Hardware saving by 3+1
RNC 1~3 could be backup by RNC
ID4
Available for SRAN9.0 or later
Load sharing function can work
together
RNC 3
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 20
GSM BSC Hot Backup solution
BSC Node Redundancy
Iub
BSC
Benefit
BTS
BTS
MSC SERVER
Backup BSC
SGSN
Primary
Standby
BSCs are connected for node redundancy
Standby links are required
Traffic recovery would take
15 mins
One key Swapping or
Automatic Swapping
Automatic synchronization of
configuration
Redundancy in same or
different place
No KPI lose
Standby RNC software version should be the as Primary RNC
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 21
GSM BSC Hot Backup solution BSC6910 1+1
BSC6910 1+1
Specification
BSC products should be the same
The transmission should be all IP
Available for SRAN8.0 or later
BSC 1
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
BSC 2
Page 22
GU MBSC Hot Backup solution BSC6910 1+1
BSC6910 1+1
Specification
Software versions should be the
same
Iur-p
Available for SRAN9.0 or later
MBSC 1
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
MBSC 2
It takes 10s for UMTS service
recovery
It takes 15mins for GSM service
recovery
Page 23
BSC6910 Successful Cases
BSC6910
BSC6910 Worldwide
Worldwide Footprints
Footprints
BSC6910 selected by
months
60+
operators within
GA+12
(as of 2014.6)
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 24 24
Page
BSC6910 Commercial Deployment in StarHub 1/2
Traffic
Past
Traffic
Now
RNC RNC RNC RNC
#1 #2 #3 #4
RN
C
#1
Signaling: 30% CAGR
150x in 10 years
NodeBs
NodeBs
Signaling
Smartphone
penetration
Challenge: Signaling Storm of Full configuration for BSC6900
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 25
Page
25
BSC6910 Commercial Deployment in StarHub 1/2
BSC6900
BSC6910
Max Capacity
+200%
Swappin
g
Board Type
-65%
Place
Requirement
-50%
Power
consumption
-40%
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Page 26
Huge Capacity with Redundancy in Operation 1/2
Arnhem
BSC6910
Huge Capacity
Biggest
Biggest Operational
Operational BSC
BSC on
on Network
Network
TRX
More
then
6000
per
TRX More then 6000 per BSC
BSC
BSC6910
Node Redundancy
Higher Level for Reliability to support Huge
Backup BSC link
Den Haag
Rotterdam
Higher Level for Reliability to support Huge
Capacity
Capacity of
of BSC6910
BSC6910 for
for BSC
BSC Node
Node
Redundancy
&RNC
in
pool
Node
Redundancy &RNC in pool Node
Redundancy.
Redundancy.
BSC6910
Higher Reliability
One Cabinet
Less Space than before
BSC6910 in Node Redundancy Mode to provide Reliability
HUAWEI TECHNOLOGIES CO., LTD.
Page
Page 27
27
Huge Capacity with Redundancy in Operation 2/2
Broad
Big Capacity
Big Capacity
Reliability
RNC
RNC in
in POOL
POOL Node
Node Redundancy
Redundancy &
& BSC
BSC Node
Node
Redundancy.
Redundancy.
Active
Active
Active
Active
Active
Active
Active
Active
Redundancy
Redundancy
Redundancy
Redundancy
Redundancy
Redundancy
Redundancy
Redundancy
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
Efficiency
1 EGPUa for GSM&UMTS
Page 28
Page
28
BSC6910 Deployed in VIVA Kuwait 1/2
Before: BSC6900 High CPU usage
60%
50%
40%
CPU usage
30%
20%
10%
0%
CPU 1 CPU 2 CPU 3 CPU 4
Challenge: High traffic lead to high CPU usage of SPU boards when special events like
Celebrations and peak hours
HUAWEI TECHNOLOGIES CO., LTD.
Page 29
BSC6910 Deployed in VIVA Kuwait 2/2
Load Sharing
BSC6910
80.0%
BSC6900
BSC6900 CPU Load
Busy hour
signaling
Tolerancecan do
BSC6910
load sharing for
max 3*BSC6900 by
Iur-P interface for
Signaling(CP) in
busy hour
70.0%
BSC690
0
BSC69
00
60.0%
55.8%
50.0%
- 10%
45.4%
40.0%
30.0%
20.0%
10.0%
0.0%
NodeB
NodeB
NodeB
Master RNC control plane CPU Load
decrease 10%.
No impact on KPI
Benefit: CPU usage low down by using a BSC6910 by RNC in POOL Load Sharing
HUAWEI TECHNOLOGIES CO., LTD.
Page 30
BSC6910 Values Summary
Broad
For 100% Smart
phone scenario
High CP
specification
for signaling storm
Reliability
250
200
100
0
130
120
40
64
14
Industr
y
CP Pool
UP Pool
Transmission Pool
RNC Redundancy
One for All (EGPUa
Processing Board)
CP/UP Dynamically
Sharing in one board
HUAWEI TECHNOLOGIES CO., LTD.
II
N
N
T
T
F
F
II
N
N
T
T
F
F
Pool
Capacity beyond
industry
G
G
P
P
U
U
G
G
P
P
U
U
G
G
P
P
U
U
Pool
Smooth
Efficiency
II
N
N
T
T
F
F
RNC in Pool
P
o
o
l
1
BSC691
0 P
P
o
o
o
o
l
l
2BSC69003
Smooth Evolution:
BSC6900 and BSC 6910
in Pool
Burst Load Sharing to
BSC6910
Smooth Expansion w/o
RNC ID Adjustment
Ready for Cloud
Evolution
Page 31
uawei BSC&RNC is a leader in the marketplace
BSC6910
According to Current Analysis:
Huaweis 3GPP Controller is a leader in the marketplace.
Huaweis proactive innovations make a compelling argument for the potency of Huaweis solutions.
RNC in Pool Load sharing were launched in Italy TI
July, 2014, one BSC6910 + Two BSC6900
RNC in POOL were launched
successfully in Italy TI.
New BSC6910 and RNC in POOL load sharing solution
bring a result of the CPU load down from a high load 58% to 49% , This is a new
solution for RNC expansion without split . Next , TI would make more RNC in
POOL in TI networks, and RNC in POOL Node Redundancy would be used too.
Background Brief: Telecom Italia, TIM, TIM Brasil, Olivetti, Telecom Italia Sparkle
are the main brands of Telecom Italia Group who is the one of biggest operator of
Italy.
New
RNC 1
RNC 2
RNC in POOL were launched in Manx Telecom
July, 2014, two BSC6910 & RNC in POOL were launched successfully in Manx
Telecom, Britain. BSC6910 and RNC in POOL Node Redundancy solution
features10s disaster recovery after a RNC failure, whereas the traditional
solution needs at least 3~5 hours
RNC in POOL solution are recommended global. More than 10 operators
ordered this solution , for example T-Mobile, VDF , China Unicom and other big
operators would used later.
Background Brief: Manx Telecom is the No.1 operators of Isle of Man.
BSC6910
BSC6910
Primary
Standby
BSC6900 & BSC6910 Comparison
Advantage of
BSC6910
BSC6910
BSC6900
FAQ
1. License can not be
transferred from
BSC6900 to BSC6910
Higher efficiency : Dynamic CP & UP
Higher efficiency : Dynamic CP & UP
adjustment.
adjustment.
Larger Capacity : 3~6x CP & UP
Larger Capacity : 3~6x CP & UP
Less board : 1 for All Processing
Less board : 1 for All Processing
EGPUa 10GE
EGPUa 10GE
Smarter: Automatic NodeB rehoming
Smarter: Automatic NodeB rehoming
HUAWEI TECHNOLOGIES CO., LTD.
2. BSC6910s Power
Distributions are
different from
BSC6900s .
3. New NBI depends
on new cooperation
from OSS system.
3
5
Page 35
Larger Capacity leads more Power consumption
RTN1(+)
NEG1(-)
BSC6910
8*Cables
8*Cables
Capacity
RTN1(+)
NEG1(-)
BSC6900
8*Cables
8*Cables
BSC6910 Vs BSC6900
RTN1(+)
NEG1(-)
8*Cables
8*Cables
4000W each
Subrack
VS
5100W each
cabinet
RTN1(+)
NEG1(-)
1.
3X Power Cables
2.
4000W each
Subrack
VS
1700W each subrack
8*Cables
8*Cables
3. 7100W each cabinet
VS
5100W each Cabinet
HUAWEI TECHNOLOGIES CO., LTD.
Page 36
New Platform leads NBI Change
NBI NorthBound Interface
Performance
difference
Alarm difference
BSC6910
BSC6900
New Platform : New generation boards EGPUa &
New Platform : New generation boards EGPUa &
Parameter
difference
Hardware &
Capacity
difference
Changed Parameters
number 20%
EXPUa.
EXPUa.
New Features : CP&UP dynamic sharing & RNC in
New Features : CP&UP dynamic sharing & RNC in
POOL
POOL
O&M Optimization : Automatic NodeB rehoming &
O&M Optimization : Automatic NodeB rehoming &
IP POOL
IP POOL
Larger
Capacity
: 3~6X
HUAWEI
TECHNOLOGIES
CO., LTD.
Capacity enhancement
Unchanged Parameters
number 80%
Page 37
Page 37
Thank you
Thank you
[Link]
Intelligent Unit in MBSC
P2P Download Control : Avoid Overcapacity
HSDPA carrier throughput w/o P2P throttling
P2P
NIU
Board
Non-P2P
Time
HSDPA carrier throughput w P2P throttling
Non-P2P traffic increase
in loaded cell
P2P
Service Identification MBSC
Board
Network Intelligence Unit Service
Engine in RAN
HTTP Acceleration (Web browsing)
P2P download control (Bit Torrent,
Non-P2P
Time
Web Acceleration Benefit
50
40%
30
thunder, eDonkey, GNUTELLA)
IM/Email Efficiency Improvement
4
5.8
1.2
Streaming Media Service Resource
Balancing
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
1.1
30%
Page 39
10%
BSC6910 with Superior Performance, Reliability &
Scalability
250
RNC in Pool
200
130
120
Industry
64
100
20
Huawei
BSC6910
14
0
Throughput(G)
BHCA(kk)
Superior Performance
Built-on Proven BSC6900s Experience
First-in-class Terabit-switching
Platform
Best-in-class 120 Gbps Iub & 64M
BHCA
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
NodeB
Erlang(k)
High Reliability & Scalability
Board/Port Resource Pool for Optimal
System Reliability & Hardware
Efficiency
RNC in Pool for NE-level Reliability ,
Scalable to 240G in 2013 & 480G in
future
Page 40
Huawei Controller Evolution, Meet MBB Fast Growth
Cloud and Convergence
BSC6900
Single Platform For GU
BSC6900
Board Pooling
Optimization
BSC6910
New Platform For MBB
G&U
Future
UMTS
GSM
Before
24 Gbps
3720K BHCA
Service awareness
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
2013Q2
2012Q2
40 Gbps
5300K BHCA
Interface board
pooling
Control plane load
sharing
120 Gbps (PS Traffic
Model)
64M BHCA
(Smartphone Traffic
Model)
EGPU, 1 board for all
CP/UP dynamic sharing
RNC in Pool expand
BSC6900 with BSC6910
Page 41
Tbps level capacity
with
software upgrade
Cloud Architecture,
sharing resources
anywhere
Difference I : Power Distribution of BSC6910&6900
RTN1(+)
NEG1(-)
BSC6910
8*Cables
8*Cables
RTN1(+)
NEG1(-)
BSC6900
8*Cables
8*Cables
BSC6910 Vs BSC6900
1.
RTN1(+)
NEG1(-)
8*Cables
8*Cables
RTN1(+)
NEG1(-)
8*Cables
8*Cables
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
3X Power Cables
2. 4000W each Subrack
VS
1700W each subrack
3. 7100W each cabinet
VS
5100W each Cabinet
Page 42
Difference II : NBI Main Change Summary of BSC6910&6900
NBI NorthBound Interface
Performance
difference
Alarm difference
BSC6910
BSC6900
UMTS:
40 Gbps
5,300K BHCA
3060 NodeB/5100 Cell
GSM:
8,192TRX/45,000Erl
11,000K BHCA
2048 BTS/2048 Cell
HUAWEI TECHNOLOGIES
CO., LTD.
HISILICON
SEMICONDUCTOR
UMTS:
120 Gbps
64,000K BHCA
10,000 NodeB/20,000 Cell
GSM:
24,000TRX/150,000Erl
52,000K BHCA
8,000 BTS/8,000 Cell
Page 43
Page
43
Parameter
difference
Hardware &
Capacity
difference