100% found this document useful (1 vote)
674 views2 pages

Datasheet For Flow Computer

This document is a datasheet for a flow computer to be used on a gas-condensate well project in Vietnam. It provides specifications for the flow computer including its tag number, service, process conditions it will monitor, calculations it can perform, mounting details, power supply, and manufacturer/model. Dimensions and documentation requirements are also listed.

Uploaded by

Angela Barber
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
674 views2 pages

Datasheet For Flow Computer

This document is a datasheet for a flow computer to be used on a gas-condensate well project in Vietnam. It provides specifications for the flow computer including its tag number, service, process conditions it will monitor, calculations it can perform, mounting details, power supply, and manufacturer/model. Dimensions and documentation requirements are also listed.

Uploaded by

Angela Barber
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Client

DATASHEET
FLOW COMPUTER
Supplier
PROJECT:
GAS-CONDENSATE WELL 10b ON RC-1 PLATFORM
ISO 9001-2008

RC3/RC1

VIETNAM

Requisition No.

Document No.

RC1RC3-I-DS-4009

Sheet No.

1 of 2

Rev.

Item Tag No.

Service

DATA SHEET FOR FLOW COMPUTER

ISSUED FOR BID

NTH

DTT

ISSUED FOR REVIEW

NTH

DTT

TVV

DESCRIPTION

PREPARED

CHECKED

APPROVED

REV

DATE

TVV
CLIENT APPROVED

DATE

Client
DATASHEET
FLOW COMPUTER

Supplier
PROJECT:
GAS-CONDENSATE WELL 10b ON RC-1 PLATFORM

TAG NO.
SERVICE
P & ID NO.
LINE NO.
LINE SIZE / SCHEDULE
DESIGN PRESSURE
DESIGN TEMPERATURE
Hazardous area classification
Flow (Sm3/d)
Pressure (Barg)
Temp. (Deg.C)
Viscosity (cP)
Density (kg/m3)
Specific gravity
Molecular weight
Compressibility

VIETNAM

Document No.

RC1RC3-I-DS-4009

Sheet No.

2 of 2

Rev.

Item Tag No.

AS BELLOW

Service

AS BELLOW

FC-GAS-02
CUSTODY METERING UNIT
RC3-B-3086-1
N/A
N/A
(Barg) N/A
20 deg.C
(oC)
Safety Area
250000 - 600000
15 - 105
45 - 52
0.01216 - 0.01662
15.12 - 110.5
0.015 - 0.110
20.93
0.7640 - 0.9459

Gross flow rate


Net flow rate
Net flow rate corrected
Mass flow rate
Totalized gross flow 6 digit
Totalized net flow 6 digit
Totalized mass flow 6 digit
Density
Line pressure
Calculation method

Yes (unit: m3/day)


Yes (unit: Sm3/day)
Yes (unit: m3/day)
Yes (unit: 0.01ton/day)
Yes (unit: 0.01m3)
Yes (unit: 0.01m3)
Yes (unit: 0.01ton)
Yes (unit: kg/m3)
Yes (unit: kPag)
API / ISO 5167

Mouting
Power Supply
Calculation accuracy
Application Firmware
Licenced configuration software
Display
Operator keypad
Analog Signal
Digital Signal
Interface

Standard Panel Mounting


230 VAC & 24 VDC
0.001%
R27 (*)
Yes
LCD, 4 Lines x 20 Character, 5 x 8 Dot/ Character
Yes
Yes
Type
Analog Input module
Signal type
NA
Type
Digital I/O module
Signal type
2 x RS485 for Client PCS (RS485), Gas Chromatograph
1 x RS232 for Service PC
1 Printer port
Yes

Security
Dimensions
- Panel Cut-out Size
- Front Panel Size
MANUFACTURER
MODEL NUMBER

*
*
OMNI OR EQUAL
6000

OTHERS

EQUIPMENTS SPECIFICATION

CALCULATIONS

PROCESS CONDITION

GENERAL

RC3/RC1

1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54

Requisition No.

1.

- Vendor to confirm / advice

The documentations / certificates will be minimum submitted as following:


- General Arrangement Drawings
- Operating Manual
- Maintenance Manual
- Catalog
- Typical Installation / Mounting
- Wiring connection: Power, Communication with Field input, Client PCS (RS485), Printer, Service PC

4AI x (4 20) mA